A Study on Design and Implementation Processes of a Smart Factory for Aircraft Parts (항공기 부품 스마트 공장 구축 프로세스 연구)

  • Kim, Byung-Joo;Kim, Deok Hyun;Lee, In Su;Jun, Cha-Soo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.43 no.3
    • /
    • pp.229-237
    • /
    • 2017
  • Presented in this paper is a case study of constructing a smart factory for aircraft parts. The construction procedure involves four phases. First of all, its management goals are set, and layout design and simulation are carried out in the conceptual design phase. In the detail design phase, operating scenarios for each module are written out, and probable risks are analyzed by expert groups, and then requirements for developing equipments and subsystems are determined with consideration for element technologies and their integration schemes into the smart factory. In the fabrication and installation phase, system development, equipment fabrication and installation are proceeded in a separate manner, and then integrated together subsequently. In the operation and improvement phase, the factory is stabilized, sophisticated and improved constantly during real operation.

Measurement of Time-Varying Failure Rate for Power Distribution System Equipment Considering Weather Factor (기후인자를 고려한 배전계통 설비의 시변 고장률 추정)

  • Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.14-20
    • /
    • 2009
  • In this paper, the time-varying failure rate to consider climate effect was extracted. Even if the same kind of equipments is estimated for extracting the time-varying failure rate, the failure rates could be different depending on external effect such as climate. With the consequence, the failure rate extracted to consider the climate effect is necessary for using the failure rate on the optimal investment plan or asset management, To consider the characteristic of climate effects(Classified into 5 categories, heavy rain, thunderbolt, strong wind, tidal waves, no character), the survey of officers charging the operation of equipment in KEPCO branch office was done. With this consequence, this paper suggest the failure rate extraction method to consider the climate effect analyzed by the survey.

Development of Guard Lamp Remote Inspecion System Using Resistive Leakage Current Detecting (저항성 누설전류 검출방식을 이용한 보안등 전기설비 원격점검 시스템 개발)

  • Choi, Myeong-Il;Yoo, Jae-Geun;Jeon, Jeong-Chay;Bae, Suk-Myeong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.81-89
    • /
    • 2009
  • Recently, Guard lamp was divided from electric facilities for general use as dangerous zone of safety management. This paper presents a remote inspection system of guard lamp that can monitor electrical safety factor. Especially, the developed system adopts the measurement algorithm for detecting resistive leakage current($I_{gr}$) flowing based on the phase difference checkable for sensing at a monitor. Also, It was fabricated the repeater for data transmission and the MMI program At this system, we made experiment on stability of resistive leakage current to verify phase comparison detecting algorism.

An Improvement Scheme of Direct Load Control Program for Electric Power Demand Management (합리적 전력수요관리를 위한 직접부하제어 사업의 개선 방안)

  • Kim, Kyu-Ho;Choi, Seung-Kil;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.81-86
    • /
    • 2007
  • This paper proposes the scheme to improve the current direct load control(DLC) program by inspecting the problems of the DLC program. In order to increase the number of the customers participating DLC program, a reduction of the base incentive and an increase of the direct load control incentive are suggested based on the interruption cost of electric power considering the characteristics of load types and the introduction of demand side bidding is recommended. Secondly, the standards of power system operations is required to control DLC program efficiently for the penalty, interruption times, the number of interrupting loads, notice time for the load interruption and the periods of the DLC program contract.

A New Market Transformation Policy for the Mid-Night Demand Discount Program (시장전환 정책을 통한 심야전력제도 개선방안에 대한 연구)

  • Kim, Chang-Sub;Kim, Jin-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.19-25
    • /
    • 2008
  • In this paper, we have proposed a new market transformation policy to improve the existing rate discount program for the mid-night demand. The rate discount program for the mid-night demand is designed to relieve day-time demand and grow night-time demand since 1985. From this program, customer can save their electricity bills and at the same time electric utilities increase the load factor and utilization rate for the base-load generators such as nuclear and coal. Since this program has been introduced however, many economic problem has been brought out. This paper, therefore, has suggested new market transformations to resolve this problem, whereby economic loss can be shrink while all the interested party can minimize their individual benefits.

The Accident Hazard and Properties of the Leakage Current on the Electrical Insulation by Pollution (전기 절연물의 오염에 따른 누설전류 특성 및 사고위험성 연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Jung, Jin-Su;Jung, Jong-Wook;Kim, Sun-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.463-467
    • /
    • 2007
  • It is necessary to study the prevention and the management of electrical facilities because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. The leakage current brings out electrical fault after all. Also, it is need to variation of material and shape to repress a leakage current on electrical material. In this paper, we measured a leakage current on electrical material of facilities by dust, and in experiments the prevention to electrical fault was studied.

  • PDF

An feeder Automation System Using Active Database (능동 데이터베이스 이용한 배전선로 운전자동화)

  • 최상열
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.94-102
    • /
    • 2003
  • This paper presents active management of feeder automation systems using active database. DAS(Distribution Automation System) has been managed for feeder automation in passive manner. Therefore, feeder automation system has to be managed by operator when feeder overloadings is detected. It may be possible for propagating the feeder overloadings area by operator's mistake. To overcome this defect, the author proposed the feeder automation technique with active manner to obtain feasible feeder reconfiguration. Active database can manage feeder automation system by data driven monitoring of events and by corresponding actions without operator's intervening. To manage feeder automation system with active manner, production rule, active rule manager are designed. And active database system architecture for feeder automation system is proposed. Test results on the KEPCO's 108 bus distribution system show that the performance is efficient and robust.

Development of Intelligent Demand Controller (지능형 최대수요전력관리장치의 개발)

  • 김병진;정을기;한운동;전희종
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.50-55
    • /
    • 2000
  • In this paper, the intelligent demand control system was introduced. This system was composed of Intelligent demand controller, RTU(Remote Terminal Unit) and HMI(Human Machine Interface) program.The main features of developed system meter recommended by KEPCO. Secondly, the developed demand controller had a measurement function, so system could be simplified. Thirdly, network function was implemented to control a distanced loads. With program, the users who was not trained could operate system. Additionally, management based Web was considered to monitor and manage the system remotely. The system performance was proved in a several experiments.

  • PDF

Survey Analysis of the Management of Fire Fighting Equipment (소방시설의 관리실태 조사 분석)

  • Mun, Suck-Jin;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.98-103
    • /
    • 2011
  • Currently, domestic architecture has applied the building fire-fighting equipments to most buildings except conventional houses, villas and facilities, and so on. However, the use of fire-fighting equipments what are not working properly result in a human life and property damages consistently like a fire of Icheon warehouse facilities, Korea cold storage, the tragic incident of subway in Daegu and the recent issue of a fire in the high-rise efficiency apartment, etc. In this study, I'm trying to seek solutions by taking research on the actual condition of fire alarming system, fire escaping equipment, Indoor Fire Hydrant Installation.

State of Charge Estimation of Li-Ion Battery Based on CIM and OCV Using Extended Kalman Filter (전류적산법과 OCV 방법을 결합한 Li-Ion 배터리의 충전상태 추정)

  • Park, Joung-Ho;Cha, Wang-Cheol;Cho, Uk-Rae;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.77-83
    • /
    • 2014
  • The Estimation of State of Charge(SOC) for batteries is an important aspect of a Battery Management System(BMS). A method for estimating the SOC is proposed in order to overcome the individual disadvantages of the current integral and Open Circuit Voltage(OCV) estimation methods by combining them using Extended Kalman filter(EKF). The non-linear characteristics of the Li-Ion RC battery model used in this study is also solved through EKF. The proposed method is simulated in a Matlab environment with a Li-Ion Kokam battery (3.7V, 1,500mAh). Results showed that there is an improvement in the estimation error when using the proposed model compared to the conventional current integral method.