• Title/Summary/Keyword: installation/management

Search Result 1,166, Processing Time 0.027 seconds

Management Changes of Hazardous Air Pollutants Sources and Its Proposed Improvement in Korea (유해대기오염물질 배출원 관리의 변천과 개선방향)

  • Kim, Jong-Ho;Lee, Jeong Joo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.536-544
    • /
    • 2013
  • Even a small amount of hazardous air pollutants could have a harmful influence upon human beings, animals and plants. Hazardous air pollutants have the properties of toxicity, canceration and organism accumulation. They include heavy metals, volatile organic compounds, polycyclic aromatic hydrocarbons, dioxin, etc. The Clean Air Conservation Act has defined specific hazardous air pollutants and designated 35 pollutants, distinguishing them from common air pollutants for special control. This study investigates the history of the controls of specific hazardous air pollutants with reference to some relevant laws and regulations in Korea. It investigates the regulations at the permission stage, such as the restrictions on installation of emission facilities, the permission and reporting of installation of emission facilities, and the regulations at the operation stage, such as maintaining permissible emission levels, installation of measuring devices, dues for emission, self-measurement and securing environmental engineers. The current regulatory management is not so satisfactory in regards to the serious effects of specific hazardous air pollutants upon the human body. An advanced new concept, like the maximum available control technology in US, the facilities management standards, which will soon take effect, will be able to lessen the emissions of fugitive hazardous air pollutants. In addition, this study discusses some possible stricter controls on the emission facilities of specific hazardous air pollutants and proposes some measures to maintain and supplement the current systems.

Developing the Installation Guideline of Building Monitoring Systems for Hazardous Symptom Measurements with Visual Perception (시지각적 요소를 갖춘 건축물 위험징후 측정 모니터링 시스템 설치 가이드라인 개발연구)

  • Kim, Heejae;Kim, Geunyoung;Shin, Jungjae
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.374-382
    • /
    • 2020
  • Purpose: Recently, structural defects in old safety management facilities have led to the collapse of buildings and facilities. The purpose of this study is to develop guidelines for the installation of regular monitoring systems that determine the optimal sensor location for monitoring exhibition space building sensors equipped with visual elements in order to analyze the risk signs of exhibition space buildings and develop measurement technology. Method: The components, installation locations, alarm criteria, and management measures of the instrument are presented. Result: A measure was proposed to determine the location of sensors, secure signal processing technology for analysis by having unified visual perception, and configure optimal 'risk sign detection' based on sensor monitoring through test-bed operation. Conclusion: The results of this study can be prepared against the disasters that may arise from the collapse of exhibition buildings, and contribute to strengthening safety management capabilities.

A Study on Application of LID Technology for Improvement of Drainage Capacity of Sewer Network in Urban Watershed (도시 유역의 우수관망 통수능 개선을 위한 LID 기술 적용 연구)

  • Baek, Jongseok;Kim, Baekjoong;Lee, Sangjin;Kim, Hyungsan
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.617-625
    • /
    • 2017
  • Both domestic and overseas urban drainage systems have been actively researched to solve the problems of urban flash floods and the flood damage that is caused by local downpours. Recent urban planning has been designed to better manage the floods of decentralized rainfall-management systems, and the installation of green infrastructure and low-impact development (LID) facilities at national ministries has been recommended. In this study, we use the EPA SWMM model to construct a decentralized rainfall-management network for each small watershed, and we analyze the effect of the drainage-capacity improvement from the installation of the LID technologies in vulnerable areas that replaces the network-expansion process. In the design of the existing urban piping systems, it is common to increase the pipe size due to the increment of the impervious area, the steep terrain, and the sensitive entrance-ramp junction; however, the installation of green infrastructure and LID facilities will be sufficient for the construction of a safe urban drainage system. The applications of LID facilities and green infrastructure in urban areas can positively affect the recovery of the corresponding water cycles to a healthy standard, and it is expected that further research will occur in the future.

The Loading Mock-up test for Construction Management of Cable net Facade (케이블넷 파사드의 시공관리를 위한 하중재하 Mock-up실험)

  • Moon, Sang-Deok;Ock, Jong-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.28-29
    • /
    • 2014
  • Cable net system openness and flexibility is good high and the large deflection caused no damage to the structure itself. However, cable installation, install complex systems and technologies are needed. In this study, for the basic materials of cable net construction management, cable net expert's advice and mock-up test results are summarized.

  • PDF

Assessment for Characteristics of Flow According to Installing Hydraulic Structures by 2-D Numerical Model (2차원 수치모형을 이용한 수공구조물 설치에 따른 수리학적 흐름 영향 평가)

  • Choi, Seung Yong;Nam, Ki Young;Han, Kun Yeun
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.797-813
    • /
    • 2011
  • Frequently occurring flood and drought due to abnormal climate and global warming have increased the necessity of an effective water resources control and management of river flows. The various hydraulic structures are constructed in river as part of an effective water resources management. It is very important to analyse characteristics of flow according to installing hydraulic structures in this situations. The objective of this study is to investigate the hydraulic behaviors of flow considering affections of hydraulic structures using 2-D numerical model. To do this, both RMA-2 model and developed RAM2 model are used to analyse flow phenomena before and after installation of hydraulic structures in Nakdong river. As a result of, the water surface elevation at upstream regions increased about 22cm~66cm and the velocity around the structures sharply increased after installation of structures. The measures for the rise of water surface at upstream and local scour due to high velocity around the structures must be established when the structures is constructed.

A Study on the Illuminance Recommendations for a Museum Storage Area (수장공간의 조도기준에 대한 연구)

  • 김홍범
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.1-6
    • /
    • 2002
  • Museum storage area is one of the most important places because collections are central to museums. However it is often misunderstood and treated as the storage areas of general office buildings md factories. In this paper, lighting design factors for museum storage areas are reviewed, and illuminance values for the various storage areas of the KS and the other countries'are compared and discussed in consideration of collections' management and conservation. And paying our due regard to collections management it is found that the standard illuminance value for museum storage area of the KS is lower than those of the other storage places. Therefore it is raised to 200[㏓]and supplementary lighting which can be controlled separatedly should be provided to increase the illuminance of task lighting.

Development of the voltage management recorder using o dual-slope A/D converter for power distribution lines (Dual-slope A/D 변환을 이용한 배전선 전압관리용 계측기 개발)

  • 손수국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.38-44
    • /
    • 2002
  • This paper describes the development of a new voltage recorder for the voltage management of power distribution lines. The voltage characteristics and measurement problems for the power distribution lines are analyzed and the functions required for the recorder are discussed. Applying a dual-slope A/D converter with low noise characteristics the voltage measurement algorithm, design and implementation for the recorder are discussed. Finally, the voltage variations of long-duration over-voltages or under-voltages, and short-duration temporary interruption based on IEEE 1159 are analyzed. It is verified with the experiment.

A Study on Economic Evaluation of FPL 45[W] Lamp and Ballast to Demand Side Management (FPL45[W]램프, 안정키의 전력수요관리를 위한 경제성 평가 연구)

  • Im, Song-Kug;Cho, Hyun-Kyung;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.101-107
    • /
    • 2009
  • The energy efficiency of existing lighting appliances has continuously been improving due to the government aid such as rebate programs and information of energy saving, etc. However, the usage pattern of lighting appliance at this moment has more been increasing higher illumination and indirect lighting method according that the taste of customers has changed variously. This paper estimates the economic evaluation and simulation for FPL45[W] lamp & ballast instead of FPL55 lamp & ballast in order to study the governmental support to demand side management.

A Study on the Safety Checking and Testing method of the underground power transmission line (OF Cable) (지중송전선로 안전관리 방안 (OF케이블))

  • Choi, Jong-Soo;Park, Kang-Seo;Jeon, Jun-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.429-434
    • /
    • 2009
  • In this paper it was written about the safety management plan for underground power transmission cable, and it guarantees the reliable electric power supply and facility management to prevent an electric disasters according to that. Recently fires which happens on OF Cable lead to a breakdown of power system and cause a power outage of wide area and serious social problems. So it needs an improvement of inspection ability on OF cable as well as a strict inspection system to prevent that problems in advance and it will bring us the development of electric safety management and the reliable electric power supply.

  • PDF

Database Construction to Compute Representative Model of Load Power Factor in Bulk Power System (대규모 전력계통의 부하역률 대표모델 산정을 위한 데이터베이스 구축)

  • Cho, Jong-Man;Lee, Hyo-Sang;Lee, Jung-He;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.83-89
    • /
    • 2004
  • The importance of the Load Power Factor(LPF) management is newly noticed from the voltage management and operation of the power system due to the rapidly increasing reactive power consumed. Therefore, this paper proposes the regional, seasonal and hourly Representative Model of Load Power Factor(RMLPF) considering load characteristics of all 154/22.9[kV] substations. The RMLPF is used to present a precision improvement of power system analysis and security. Computation of representative model of load utilizes the average flow method based on moving average method. The Energy Management System(EMS) data are used as the source to assess the load power factor.