• 제목/요약/키워드: inspection.calibration

검색결과 146건 처리시간 0.027초

DEEP-South: Performance of Moving Object Detection Program in Different Observation Modes

  • Oh, Young-Seok;Bae, Yeong-Ho;Kim, Myung-Jin;Roh, Dong-Goo;Jin, Ho;Moon, Hong-Kyu;Park, Jintae;Lee, Hee-Jae;Yim, Hong-Suh;Choi, Young-Jun
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.48.3-49
    • /
    • 2016
  • We have five different types of observation modes with regard to the Deep Ecliptic Patrol of the Southern Sky (DEEP-South); Opposition Census (OC) for targeted photometry, Sweet Spot Survey (S1) for discovery and orbit characterization of Atens and Atiras, Ecliptic Survey (S2) for asteroid family studies and comet census, NEOWISE follow-up (NW) for near simultaneous albedo measurements in the visible bands, and Target of Opportunity (TO) observation for follow-up either for unpredictable events or targets of special interests. Different exposures with such different modes result in a wide range of background noise level, the number of background stars and the mover's projected speed in each image. The Moving Object Detection Program (MODP) utilizes multiple mosaic images being taken for the same target fields at different epochs at the three KMTNet sites. MODP employs existing software packages such as SExtractor (Source-Extractor) and SCAMP (Software for Calibrating Astrometry and Photometry); SExtractor generates object catalogs, while SCAMP conducts precision astrometric calibration, then MODP determines if a point source is moving. This package creates animated stamp images for visual inspection with MPC reports, the latter for checking whether an object is known or unknown. We evaluate the astrometric accuracy and efficiency of MODP using the year one dataset obtained from DEEP-South operations.

  • PDF

동해안 군사시설보호구역 주변 향호 연안역을 대상으로 무인항공사진측량에 관한 예비 연구 (A Preliminary Study on UAV Photogrammetry for the Hyanho Coast Near the Military Reservation Zone, Eastern Coast of Korea)

  • 김백운;윤공현;장태수;박장준;김성필
    • Ocean and Polar Research
    • /
    • 제39권2호
    • /
    • pp.159-168
    • /
    • 2017
  • To evaluate the accuracy of UAV photogrammetry for Hyangho coast, eastern coast of Korea, we conducted a field experiment wherein UAV photogrammetry test was repeated three times. Since the Haygho coast is located within a military reservation zone, it was necessary to obtain permission to gain access to the beach and to have sensitive aerial photographs showing military facilities inspected and cropped. The standard deviation of the UAV shooting position between the three tests was less than 1 m, but repeatability of footprint on the ground was low due to wind-driven variability of the UAV pose. Self-calibrating bundle adjustment(SCBA) of implementing non-metric camera calibration was failed in one test. In two tests, the vertical error was twice as large as the pixel size except for those areas that were subject to security inspection and cropping. Given the problems that can arise with regard to the repeatability of the shooting area as well as the possibility of failure with regard to SCBA, we strongly recommend that UAV photogrammetry in coastal areas needs to be repeated at least twice.

비규격 초음파 탐상용 표준시험편의 사용안전성 평가 (Evaluation of Suitability of Non-Standardized Test Block for Ultrasonic Testing)

  • 권호영;임종호;강세선
    • 비파괴검사학회지
    • /
    • 제20권5호
    • /
    • pp.431-437
    • /
    • 2000
  • 표준시험편이란 재질, 형상, 치수 및 성능이 권위 있는 기관에 위해 검정된 국제적인 시험편을 말하며 이것은 탐상기의 특성시험 또는 감도조정, 시간축의 측정범위 조정에 사용된다. 그런데 이 표준시험편은 초음파탐상 결과에 아주 크게 영향을 미치는 하나의 변수로 ASTM 이나 JIS에서는 이들 표준시험편의 규격, 재질 및 성분 등을 엄격하게 규격화하고 있다. 그 이유는 이들 성질들이 감도와 분해능 및 재현성에 아주 큰 영향을 미치기 때문이다. 따라서 결함의 크기 및 치수를 정량화하고 재현성 있는 결과를 얻기 위해서는 엄격한 품질의 표준시험편이 요구되고 있다. 그러나 ASTM 또는 JIS등의 규격품들은 상당히 고가이며 시중에는 품질이 검증되지 않은 표준시험편들이 일부 사용되고 있는 실정에 있고 이들 시험편의 품질 및 사용 적합성을 재고하기 위하여 각종 규격에 비추어 보고, 규격품들과 비규격품의 각종 성질들을 비교하여 그 사용 안정성을 고찰하고자 하였다. 그 결과 비규격품들은 치수 및 성분에서 많은 문제점을 안고있으며 비규격품들을 검증없이 사용할 경우 피검물내의 결함의 위치나 크기 측정에 오차를 유발할 가능성을 확인하였다.

  • PDF

공작기계용 접촉식 측정 프로브의 프로빙 오차 보상에 관한 연구 (Touch-Trigger Probe Error Compensation in a Machining Center)

  • 이찬호;이응석
    • 대한기계학회논문집A
    • /
    • 제35권6호
    • /
    • pp.661-667
    • /
    • 2011
  • 접촉식 측정 프로브는 3 차원 좌표 측정기 및 CNC 공작기계 등에서 제품 검사에 많이 활용되고 있고, 최근 품질 향상을 위한 가공 및 검사장비의 고정도화에 따라 측정의 정확도도 또한 매우 중요시 되고 있다. 이에 따라 스트레인 게이지 등을 이용한 고정도의 측정 프로브가 사용되고 있기는 하지만, 본 연구에서는 경제적인 측면을 고려하여 산업현장에서 공작기계에 많이 활용되는 일반 접촉식 측정 프로브의 메커니즘을 이해하고, 측정 시 발생할 수 있는 프로빙 오차에 대한 분석 및 보정을 통하여 그 활용성을 높이고자 하였다. 이를 위하여 스타일러스 반경 및 중심 정렬오차가 규명되었고, 3 차원 공간상의 측정 좌표에서 프로빙 오차에 대한 해석이 이루어졌다. 이러한 오차들을 보정하기 위한 알고리즘이 개발되었으며, 실제 CNC 공작기계 상에서 기준구 측정을 통한 검증이 이루어졌다.

원자로냉각재계통 3" 분기관 용접부 위상배열초음파탐상검사(PAUT)기법 개발 (Development of the Phased Array Ultrasonic Test Technique for the Weld Inspection of Reactor Coolant System 3" Branch Connection Lines in Nuclear Power Plants)

  • 이승표;문용식;정남두;조용배;김창수
    • 한국압력기기공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.40-45
    • /
    • 2008
  • There exist many types of pipe and component fatigue through vibrations, thermal fatigues or shifting. In some cases of thermal stratification/thermal fatigue, pipes & components are receiving thermal stress by means of material expansion and shrinkage by continuous thermal repetitive variation. Small cracks initially occur on the inside surface by thermal stress. These cracks grow in depth the pipe wall and finally come to a rupture. Pipe parts of susceptibility to thermal stratification and thermal fatigue are now being examined by conventional UT(ultrasonic test) as volumetric examination. It is difficult to fully satisfy the code & standards requirements because 3" weldolet weldments of RCS 16" pipe to 3" branch connection lines have complex structural shape. To solve the problems of conventional UT examination, we made a realistic mock-up and UT calibration block. We performed a simulation of phased array UT utilizing CIVA as NDE(Non-Destructive Examination) simulation software. Also we designed phased array UT transducer and wedge, optimal frequency by using simulation data. We performed phased array UT experiment through mock-up including artificial flaws(notch). The phased array UT technique is finally developed to improve the reliability of ultrasonic test at RCS 16" pipe to 3" branch connection weld.

  • PDF

국내 석면조사기관의 품질관리 수준에 대한 평가 (Evaluation of Quality Management of Domestic Asbestos Survey and Monitoring Service Providers)

  • 권지운
    • 한국산업보건학회지
    • /
    • 제29권2호
    • /
    • pp.217-225
    • /
    • 2019
  • Objectives: The aim of this study is to evaluate the quality management systems of domestic asbestos survey and monitoring service providers and the relationships with the number of licenses or designations and sales performances. Methods: Data on quality management systems were collected by assessors who were assigned by the Korea Occupational Safety and Health Agency(KOSHA) during a pilot evaluation program for designated asbestos survey and monitoring service providers in 2016 using evaluation criteria developed by KOSHA. Basic characteristics, evaluated scores, and sales performance were gathered and statistically analyzed. Results: The median and arithmetic mean of the total scores were 0.64 and 0.66. Evaluation fields that scored highly with the highest percentages were sales performance, installation and availability of equipment, compliance with the mandatory minimum number of airborne samples, laboratory independence, and results of proficiency analytical testing, in that order. Evaluation fields that received low marks with the highest percentages were the training of personnel, blank field samples, calibration of flow rates, preliminary check and visual inspection of the work area prior to the clearance test, and review and approval of final reports, in that order. Comparison of normalized scores between service providers registered for asbestos and other tasks and those designated for only asbestos showed significant differences in their evaluated scores. Sales performance did not show a positive correlation with evaluated scores. Conclusions: The quality management systems of domestic asbestos survey and monitoring service providers were poor. High scores were recorded mostly in evaluation fields related to regulatory requirements. Low scores were recorded mostly in evaluation fields related to documentation and recordkeeping. Considering the low influence of quality on sales performance, the government needs to evaluate the quality management of asbestos survey and monitoring service providers and provide the results to public in order to address their low levels of quality management.

아마추어 골프 선수를 위한 코치-선수 관계 척도의 타당화: Rasch 평정척도 모형 적용 (Validation of the coach-athlete relationship scale of amateur golf players: Rasch rating scale model)

  • 김세형;최재일;이준우
    • Journal of the Korean Data and Information Science Society
    • /
    • 제24권6호
    • /
    • pp.1319-1329
    • /
    • 2013
  • 이 연구는 Rasch 모형을 적용하여 아마추어 골프 선수들에게 적합한 코치-선수와의 관계 척도를 개발하고 타당화시키는데 목적이 있다. 코치-선수 관계 척도는 Kim과 Park (2008)이 개발한 한국판 척도를 검사내용에 기초한 증거를 토대로 수정 (11문항, 7척도)하여 아마추어 골프 선수 217명 (중학교, 고등학교, 대학교)에게 조사하였다. 그리고 WINSTEPS 프로그램을 이용하여 Rasch 모형의 기본가정인 일차원성을 검증 (주성분 분석)하였으며, 응답범주에 적절성은 단계조정값 (step calibration)을 통해 규명하였다. 이때 적합도 지수 (infit, outfit)를 통해 문항별 적합도를 검증하였으며, 골프경력 (10년미만, 10년이상)에 따라 차별기능문항을 추정하였다. 문항별로 추정되는 적합지수가 1.30 이상을 부적합하게 판단하였고, 분석에 모든 유의수준을.05로 설정하였다. 분석결과, Rasch 측정모형에 의해 설명되는 관찰분산이 20% 이상 (33.7%)으로 나타나 11문항의 일차원성 가정은 만족하였다. 그리고 응답범주 (7척도)를 단계조정값으로 분석한 결과에서 부적합하게 나타나 5점 척도로 재점수화하여 재분석한 결과에서 적합하게 나타났다. 특히 체계화된 응답범주 (5척도)를 이용하여 문항의 적합도를 추정한 결과, 상보성 요인에서 문항 10 (나는 최선을 다할 준비가 되어 있다)과 문항 11 (나는 호의적인 자세를 취한다)이 부적합 문항으로 나타났고 골프경력에 따라 차별기능문항 추정결과에서는 상보성 요인인 문항 11이 경력에 따라 비균일적으로 차별화되는 것으로 나타났다. 따라서 부적합하고 차별되는 두 문항을 제거하여 아마추어 골프 선수에게 적합한 코치-선수 관계 척도는 9문항에 5점 척도가 타당한 것으로 규명되었다.

LSTM Networks 딥러닝 기법과 SWAT을 이용한 유량지속곡선 도출 및 평가 (A study on the derivation and evaluation of flow duration curve (FDC) using deep learning with a long short-term memory (LSTM) networks and soil water assessment tool (SWAT))

  • 최정렬;안성욱;최진영;김병식
    • 한국수자원학회논문집
    • /
    • 제54권spc1호
    • /
    • pp.1107-1118
    • /
    • 2021
  • 지구온난화로 인해 발생한 기후변화는 한반도의 홍수, 가뭄 등의 발생빈도를 증가시켰으며, 이로 인해 인적, 물적 피해가 증가한 것으로 나타났다. 수재해 대비 및 대응을 위해서는 국가 차원의 수자원 관리 계획 수립이 필요하며, 유역 단위 수자원 관리를 위해서는 장기간 관측된 유량 자료를 이용하여 도출된 유량지속곡선이 필요하다. 전통적으로 수자원 분야에서 유량지속곡선을 도출하기 위하여 물리적 기반의 강우-유출 모형이 많이 사용되고 있으며, 최근에는 데이터 기반의 딥러닝 기법을 이용한 유출량 예측 기법에 관한 연구가 진행된 바 있다. 물리적 기반의 모형은 수문학적으로 신뢰도 높은 결과를 도출할 수 있으나, 사용자의 높은 이해도가 요구되며, 모형 구동 시간이 오래 걸릴 수 있는 단점이 있다. 데이터 기반의 딥러닝 기법의 경우 입력 자료가 간단하며, 모형 구동 시간이 비교적 짧으나 입력 및 출력자료 간의 관계가 블랙박스로 처리되어 수리·수문학적 특성을 반영할 수 없는 단점이 있다. 본 연구에서는 물리적 기반 모형으로 국내외에서 적용성이 검증된 Soil Water Assessment Tool (SWAT)의 매개변수 보정(Calibration)을 통해 장기간의 결측치 없는 데이터를 산출하고, 이를 데이터 기반 딥러닝 기법인 Long Short-term Memory (LSTM)의 훈련(Training) 데이터로 활용하였다. 시계열 데이터 분석 결과 검·보정 전체 기간('07-'18) 동안 Nash-Sutcliffe Efficiency (NSE)와 적합도 비교를 위한 결정계수는 각각 0.04, 0.03 높게 도출되어 모형에서 도출된 SWAT의 결과가 LSTM보다 전반적으로 우수한 것으로 나타났다. 또한, 모형에서 도출된 연도별 시계열 자료를 내림차순하여 산정된 유량지속곡선과 관측유량 기반의 유량지속곡선과 비교한 결과 NSE는 SWAT과 LSTM 각각 0.95, 0.91로 나타났으며, 결정계수는 0.96, 0.92로 두 모형 모두 우수한 성능을 보였다. LSTM 모형의 경우 저유량 부분 모의의 정확도 개선이 필요하나, 방대한 입력 자료로 인해 모형 구축 및 구동 시간이 오래 걸리는 대유역과 입력 자료가 부족한 미계측 유역의 유량지속곡선 산정 등에 활용성이 높을 것으로 판단된다.

골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로- (A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry)

  • 동경래;김호성;정운관
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권1호
    • /
    • pp.17-23
    • /
    • 2008
  • 목적 : 골밀도검사의 중요한 부분을 차지하고 있는 검사장비 및 검사자의 정밀도와 정확도는 환경에 따라 차이가 있기 때문에 질 관리가 체계적으로 이루어져야 한다. 골밀도 검사장비의 노화 및 잦은 고장에 의하여 장비의 교체 및 추가 구입으로 인하여, 추적검사를 하는 환자들의 호환성에 문제가 있다. 따라서 장비 교체 및 증설 후 동일한 장비처럼 호환하여 시용해도 환자의 임상적인 골밀도 변화를 정확하고 정밀하게 반영할수 있는지 알아보고자 한다. 재료 및 방법 : 장비 정밀도는 GE Lunar Prodigy Advance 2 대의 장비 (P1, P2)와 HOLOGIC Spine Phantom(HSP)을 이용하여 각 장비에서 20 번씩 스캔하여 팬텀을 이용한 정밀도 데이터를 획득하였고 (Group 1), 여성 120명 (평균나이 48.78, $20{\sim}60$세)을 대상으로 각 장비에서 15명씩, 같은 환자가 두 번 촬영을 하여 각 검사자의 정밀도를 측정했다(Group 2), 또한 검사자의 정밀도는 팬텀(ASP)을 이용하여 매일 아침마다 질 관리 시행후 얻은은 데이터를 기준으로, 각각의 장비에서 HSP를 이용하여 각 장비에서 20번씩 스캔 후 데�歷� 획득하여 검사자정밀도 및교차 보정 데이터를 산출하였고(Group 3), 여성 120명(평균나이 48.78, $20{\sim}60$세)의 동일 환자를 대상으로 한 장비에서 한 번씩 교차로 측정하여 검사자 정밀도 및 교차보정 데이터를 산추라였다(Group 4). 결과 : Daily Q.C Data는 $0.996\;g/cm^2$, 변동계수(%CV) 0.08로 안정된 장비로서 Group 1에서 Mean${\pm}$SD 및 %CV값은 ALP(P1: $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2: $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). Group 2에서 Mean${\pm}$SD 및 %CV값은 P1: $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2: $1.198{\pm}0.002\;g/cm^2$, %CV=0.163, Group 3에서의 Mean${\pm}$2SD 및 %CV는 P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48), Group 4에서 Mean${\pm}$2SD 및 %CV는, r값은 spine: $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998이였다. 결론 : HOLOGIC Spine Phantom과 LUNAR ASP %CV는 ISCD에서 규정한 정상오차 범위인 ${\pm}2%$안에 모두 포함되었고 BMD가 비교적 일정한 값을 유지하면 측정되어 뛰어난 재현성을 보였다. 하지만 Phantom은 환자의 체중이나 체지방 조성의 변화 등 임상적인 부분을 반영하는 데는 한계성을 갖고 있어 mis-calibration을 check하는데 유용할 것으로 판단된다. Group 3과 Group 4의 결과에서 환자를 하나의 장비로 두 번 측정한 값을 보았을 때와 두 대의 장비를 교차하여 측정한 값 모두 2SD값 이내에 포함되었고 선형회귀분석(Regression Analysis) r값이 0.99 이상으로 높은 정밀도와 상관도를 나타냄으로써 두 장비를 호환하여 추적검사를 시행하여도 영향이 없었다. 신뢰있는 BMD 산출을 위해서는 정기적으로 장비 및 검사자의 기능테스트와 이에 대한 적절한 교정행위가 이루어져야 할 것이다.

  • PDF

동적 다엽콜리메이터의 Leaf gap이 전산화 치료계획에 미치는 영향 (The dosimetric impact on treatment planning of the Dynamic MLC leaf gap)

  • 김정미;윤인하;홍동기;백금문
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.233-238
    • /
    • 2014
  • 목 적 : 최근 사용이 급증하고 있는 미국 베리안사의 이클립스 치료계획 시스템은 치료기에 설치되어 있는 다엽콜리메이터의 충돌 보호를 위해 존재하는 하드웨어적 제한성을 립 갭이라는 설정을 통하여 소프트웨어적으로 극복함으로써 정확한 치료계획을 구현 할 수 있도록 한다. 본 연구에서는 이클립스 치료계획 시스템에 설정되어 있는 립 갭이 치료계획에 미치는 영향을 분석하고 정확한 임상적용에 이용할 수 있도록 하고자 한다. 대상 및 방법 : 연구에 사용되어진 이클립스 치료계획 시스템의 버전은 11.0이다. 시스템에 설정되어 있는 립 갭은 각 치료기와 광자 에너지별로 측정되었다. 일반적으로 0.05~0.30 mm의 값을 가지고 있고, 다엽콜리메이터의 교정상태에 따라 다르므로 일괄되게 적용하지 않고 측정를 통하여 적용한다. 본 연구에서는 세기변조와 용적변조 치료계획을 측정된 각각의 립 갭을 적용하고, 립 갭이 달라질 때마다 치료계획의 영향을 Dmax, CI 등을 이용하여 평가하였다. 결 과 : 동일한 치료계획을 각각의 치료기에서 립 갭을 변화하며 평가하였을 때, 립 갭이 0.05 mm ~ 0.50 mm로 증가할수록 Dmax, CI 의 값이 2~5% 이상 증가하였다. 세기변조방사선치료계획과 용적변조방사선치료계획 모두 동일한 경향을 나타내었고 각 치료계획 간의 유의성은 찾아 볼 수 없었다. 결 론 : 치료기의 다엽콜리메이터의 립 갭 설정은 일반적으로 고유한 측정값을 가지고 있다. 하지만, 다엽콜리메이터의 노후, 교정, 수리 및 점검 후에 립 갭은 변할 수 있고, 이러한 값은 결국 치료계획에 영향을 미치기 때문에 반드시 확인 후 치료에 적용해야 한다. 경우에 따라선 립 갭을 초기 설정값을 유지하는 할 수 있는데, 이는 치료계획에 미치는 영향을 무시할 수 있기 때문에 바람직하지 않다.