• Title/Summary/Keyword: inside temperature

Search Result 2,378, Processing Time 0.033 seconds

The Relationship between Clothing Microclimate and Physiological Responses at $15^{\circ}C$ Environment ($15^{\circ}C$ 환경에서 의복기후와 인체생리반응과의 관련성)

  • Park, Joon-Hee;Choi, Jeong-Wha
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.4
    • /
    • pp.97-105
    • /
    • 2008
  • The objective of this study is to investigate the relationship between clothing microclimate and physiological responses, including subjective sensations, when, in a $15^{\circ}C$ environment, a range of temperatures inside clothing is broadly produced from using various combinations of upper and lower garments. Six male subjects participated in the investigation and the results were as follows. For all types of inside garments, the temperature of the clothing was lower than the skin temperature for the whole body in each case. The mean temperature for inside clothing ($\bar{T}_{cl}$) significantly showed the highest correlation with mean weighted skin temperature (r = 0.816) and was less positively correlated with the temperature of the inside clothing at the chest (r = 0.326) (p < .01). Values for both the energy expenditure and the heart rate were less positively correlated with the clothing microclimate (p < .01). The change of body heat content showed a negative correlation with the surface temperature of the innermost clothing (r = -0.519) and there was a difference between the innermost surface temperature and the outermost surface temperature of the clothing at the chest (r = -0.577). As td increased, the increase of body heat content declined (p < .01). There was a negative correlation between body fat and some of the temperatures inside the clothing (p < .01) and body fat had no significant correlation with the humidity inside the clothing. Subjective sensations were more highly correlated with $\bar{T}_{cl}$ than with the temperature of the inside clothing at the chest and had not significantly correlation with the humidity of the inside clothing. In conclusion, through these results, it can be seen that the temperature inside the clothing was related to various physiological responses and subjective sensations, and that the mean temperature of the inside clothing ($\bar{T}_{cl}$) showed a higher relationship with the temperature of the inside clothing at the abdomen than that at the chest.

Development of an equipment preventing overheated in a car using the solar cell

  • Han, Jong-Soo;Seo, Chang-Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.938-941
    • /
    • 2003
  • In this paper we develop an equipment which prevents vehicles from overheating their inside due to exposure to direct sunlight in summer. Overheating of inside vehicle may give rise to accidents, for instances, dying from suffocation, the deformation of its internal equipment and the explosion from the cracks of its internal parts etc.. The equipment is operated under no starting engine. We adjust the overheating of the inside vehicle by operating the equipment. This equipment checks the temperature of the inside vehicle using temperature sensor. If the temperature increases more than reference temperature(a condition which can be given by the driver), the equipment will operate until the temperature of the inside decreases to the given temperature. Its power is obtained from solar cell. So the equipment keeps away overheating accidents as well as provides the drivers with optimized condition. And also it increases the ability of original car battery through solar cell.

  • PDF

Behavior and Performance Evaluation of a Concrete Pavement Considering the Temperature Condition in a Tunnel (터널내 온도조건을 고려한 콘크리트 포장의 거동 및 성능 평가)

  • Ryu, Sung Woo;Park, JunYoung;Kim, HyungBae;Lee, Jaehoon;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.18 no.2
    • /
    • pp.11-18
    • /
    • 2016
  • PURPOSES: This paper investigates behavior and performance of concrete pavement in tunnel based on temperature data from field. METHODS : In this study, there are 4 contents to evaluate concrete pavement in tunnel, First, Comparison for distress was conducted at outside, transition, and inside part of tunnel. Secondly, temperature data was collected in air and inside concrete pavement in outside and inside tunnel. Thirdly, FEM analysis was performed to evaluate stress condition, based on temperature data from field. Finally, performance prediction was done with KPRP program. RESULTS: From the distress evaluation, failure of inside tunnel was much less than it of outside tunnel, Temperature change in tunnel was less than out side, and also it was more stable. According to result of FEM analysis, both curling stress status of inside tunnel was lower than it of outside tunnel. Based on KPRP program analysis, performance of inside tunnel was longer than outside. CONCLUSIONS : Through all study about behavior and performance of concrete pavement in tunnel, condition in tunnel has more advantages from environmental and distress point of view. Therefore, performance of inside tunnel was better than outside.

A Time Dependent Analysis of Thermal Environment in Beehouse

  • Lee, Suk-Gun;Li, Zhenhai;Choi, Kwang-Soo
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1997.11a
    • /
    • pp.20-26
    • /
    • 1997
  • The design or analysis of beehouse inside temperature environment based on steady heat transfer theory causes much deviation and theoretically it is impossible to control the inside temperature lower than the outside temperature under the condition that the bee produces heat and no cooling equipment is installed. But in practical use of beehouse, the inside temperature is somehow lower than the outside temperature because of the heat inertia of concrete floor. (omitted)

  • PDF

Analysis of Environment Control Capability Wintering Beehouse in Young Area (용인지역 저온양봉사의 환경조절성능 분석(농업시설))

  • 이석건;김란숙;이현우;이종원
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.302-307
    • /
    • 2000
  • The wintering honey bee chambers were constructed and inside environment factors were analyzed to provide high technology for efficient wintering of honeybee colonies. As a result of this study, inside air temperature of yongin chamber under the wide range of outside temperature condition was found to be appropriated for wintering of bee, and inside temperature of beehive was about 2$^{\circ}C$ higher than the air temperature in the chamber. The fan operation schedule did not control the high temperature down properly in the chamber, It was necessary to find a new fan operation schedule to be able to provide the optimum temperature for wintering honey bee colonies. inside humidity variation of Yongin chamber was very much depended on outside humidity.

  • PDF

Experimental Study on Bio-signal Characteristics of Stuckyi during Heating (스투키의 가열에 의한 생체 신호 변화 특성에 대한 실험 연구)

  • Nam, Dahyun;Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.6 no.1
    • /
    • pp.7-11
    • /
    • 2016
  • An experiment was performed to show the bio-signal characteristics of the Stuckyi when was heated. To measure the bio-signal of the plant, this study used the electrode with copper(+) and constantan(-). The electrode was directly inserted into the Stuckyi stems. And used T-type thermocouple to measure the inside temperature of the Stuckyi. During the experiments, room temperature also measured with T-type thermocouple. Heating was made with hair dryer periodically that 3 times turned on for heating 5 min and off for non-heating 25 min. Under the situation, the responses of the Stuckyi including voltage potential and inside temperature were measured using data logger(HP-34970A) according to the distances(15cm, 30cm, 45cm) between hair dryer and the plant. Through the experiments, We knew that the inside temperature has similar level and behavior with the room temperature at normal state. And during heating period, the inside temperature and the potential were also simultaneously increased sharply. From the experiments, we revealed that the measuring system of bio-signal of the plant being proposed in this study can be useful to show the Characteristics of the plants.

Thermal Environment Transition of Response Climate Change and Heat Wave Application Evaporative Cooling System (기후변화 및 폭염대응 증발냉각시스템 적용에 따른 내·외부 열환경 변화 연구)

  • Kim, Jeong-Ho;Kim, Hak-Gi;Yoon, Yong-Han;Kwon, Ki-Uk
    • Journal of Environmental Science International
    • /
    • v.25 no.9
    • /
    • pp.1269-1281
    • /
    • 2016
  • This study evaporative cooling system a heat wave climate change and reduction of the inside and outside thermal environment change research. Measurement items included micro meteorological phenomena and measured comfort indices. A micro meteorograph of temperature, relative humidity, surface temperature, and the comfort indices of WBGT, UTCI, and PMV were measured. The difference in inside and outside temperatures were compared for different land types, with the largest difference found in Type A ($4.81^{\circ}C$), followed by Type B ($4.40^{\circ}C$) and Type C ($3.12^{\circ}C$). Relative humidity was about 10.43% higher inside due to water injection by the evaporative cooling system. Surface temperature was inside about $6.60^{\circ}C$ higher than the outside all types. WBGT were Type A ($3.50^{\circ}C$) > Type B ($2.71^{\circ}C$) > Type C ($1.88^{\circ}C$). UTCI was low heat stress inside than outside all types. PMV was analysed Type C for inside predicted percentage of dissatisfied 75%, other types was percentage of dissatisfied 100% by inside and outside. Correlation analysis between land cover type and temperature, surface temperature, pmv, utci. T-test analysed inside and outside temperature difference was significant in all types of land.

Evaluation of Thermal Physiological Responses and Comfort in Dox Fabric (한지닥 섬유제품의 인체 생리 반응 및 쾌적성 평가)

  • Im, Soon
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.5
    • /
    • pp.102-114
    • /
    • 2013
  • This study performed the evaluation of skin temperature, heart rate, humidity and temperature inside clothing, and subjective sensation to estimate the physiological responses of the human body and its feeling of comfort for developing value-added dox fabric. Experiments were performed on five healthy adult women whose average age was 21, at climate chamber in which temperature, relative humidity and air current were set up below $28{\pm}5^{\circ}C$, $50{\pm}10%$, 0.2m/s, respectively. Two kinds of clothes were used for the experiments: 100% cotton and dox clothes. The clothes were identical in size and form, and the attire consisted of long-sleeved shirts, long trousers, and socks. The experiment was performed for 30 minutes using ergometer. The results are as follows. 1) It showed low skin temperature of forearm, breast, back, forehead and lower leg in exercise, but high skin temperature of them in recovery. However skin temperature of thigh and foot increased from rest to recovery. 2) It showed significant difference (p<0.001, p<0.01) in average skin temperature between cotton and dox clothes. Cotton clothes had a higher average skin temperature compared to dox. Not only was there a significant difference in temperature inside clothing (p<0.001), this was also the case with humidity inside the clothing (p<0.001).

Study of Mold Internal Temperature Measurement Using PTCR for 3-D Glass Heat Forming (PTCR을 이용한 3-D Glass 열성형 금형의 내부 온도 측정에 관한 연구)

  • Lee, Ho-Soon;Ahn, Hae-Won;Kim, Si-Gyun;Kim, Gi-Man;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.6
    • /
    • pp.146-152
    • /
    • 2017
  • In order to make 3-D glass from 2-D glass for mobile device windows, a mold is used for heat forming. In this process, the temperature of the glass is very important. However, measuring the temperature of the glass inside the mold is very difficult owing to the mold structure and the high temperature. The purpose of this study is to measure the temperature inside the mold by using Process Temperature Control Rings (PTCR) and to compensate for temperature differences in the heat forming machine and inside the mold. The measuring method uses the ceramic material's shrinkage characteristics, which makes it possible to measure the temperature inside the mold at various locations.

Prediction Model for the Change of Temperature and R.H. inside Reinforced Concrete (철근콘크리트 내부 온습도 경시변화 추정 모델 구축)

  • Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.83-84
    • /
    • 2016
  • Surplus water inside a concrete other than moisture that is used for hydration of the cement affects the physical properties of the concrete (modulus of elasticity, compressive strength, drying shrinkage, and creep) by drying. Changes in temperature and humidity inside a concrete has correlation with the movement speed and reaction rate of deterioration factors such as carbon dioxide and chloride ions. In this study, comparison was performed between temperature and relative humidity inside the concrete and meteorological data for exposure environment through measurement at the site for two years. Surface temperature of the concrete (depth 1cm) was measured higher by 6℃ during the summers, while it was measured lower by 2℃ during the winters due to solar radiation, wind, and radiation cooling. As for relative humidity, change was large in the depth of 1cm, while more than 85% was maintained in the depth of 10cm.

  • PDF