• Title/Summary/Keyword: inlet

Search Result 4,358, Processing Time 0.035 seconds

A Study on CFD Analysis to Investigate the Effects of Different Feed Rate into the High Temperature H2SO4 Transferring Pump at Fixed Frequency

  • Choi, Jung-Sik;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.3
    • /
    • pp.304-311
    • /
    • 2014
  • In this study, to apply hydrogen energy to ship engine and to generate effective hydrogen production, we investigated the effects of high temperature $H_2SO_4$ feed rate and cooling water rate to pump parts with fixed frequency needed to reciprocate motion and a simulation was conducted at each condition. In the fixed frequency and cooling water inlet flow rate of 0.5 Hz and 3.9 kg/s, we changed the high temperature $H_2SO_4$ flow rate to 47.46 kg/s (it is 105 % of 45.2 kg/s), 49.72 kg/s (110 %), and 51.98 kg/s (115 %). Also, at 0.5 Hz and 45.2 kg/s of frequency and high temperature $H_2SO_4$ flow, the thermal hydraulic analysis was performed at the condition of 95 % (3.705 kg/s), 90 % (3.51 kg/s), and 85 % (3.315 kg/s). In overall simulation cases, the physical properties of materials are more influential to the temperature increase in the pump part rather than the changes on the feed rate of high temperature $H_2SO_4$ and cooling water. A continuous operation of pump was also capable even if the excess feed of high temperature $H_2SO_4$ of about 15 % or the less feed of cooling water of about 15 % were performed, respectively. When the increasing feed of high temperature $H_2SO_4$ of up to 5 %, 10 %, and 15 % were compared with base flow (45.2 kg/s), the deviation of time period rose to a certain temperature and ranged from 0 to 4.5 s in the same position (same material). In case of cooling water, the deviation of time period rose to a certain temperature and ranged from 0 to 5.9 s according to the decreasing feed changes of cooling water at 5 %, 10 %, and 15 % compared to a base flow (3.9 kg/s). Finally, the additional researches related to the two different materials (Teflon and STS for Pitch and End-plate), which are concerned about the effects of temperature changes to the parts contacting different materials, are needed, and we have a plan to conduct a follow-up study.

Performance Characteristics of Organic Rankine Cycles Using Medium Temperature District Heating Water as Heat Source (지역난방용 중온수 열원 유기랭킨사이클 성능 특성)

  • Park, Woo-Jin;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2016
  • It is becoming increasingly important to make use of alternative energy source. because It is not able to rely on only fossil fuel for the recent increasing demand of energy consumption. With this situation, lots of studies for utilizing low grade energy such as industrial waste heat, solar energy, and geothermal energy have been conducted. The aim of this study is to predict the operation characteristics of working fluid by using performance analysis program (ThermoFlex) through the system analysis which is not mixing district return water but using ORC(Organic Rankine Cycle, hereinafter ORC) as a downstream cycle when accumulating district heating (hereinafter DH). In this study, We conducted the performance analysis for the case which has the district heating water temperature($120^{\circ}C$) and Flow rate of $163m^3/h$ (including District Heating return water flow), and examined several working fluid which is proper to this temperature. The case using R245fa (which is the best-case) showed 269.2kW power output, 6.37% efficiency. Additionally, Cut down on fuel was expected because of the boiler inlet temperature increase by being Formed $57.3{\sim}85^{\circ}C$ in a temperature of district heating return water, depending on a pressure change of a condenser in ORC system.

  • PDF

Optimal design of impeller in fan motor unit of cordless vacuum cleaner for improving flow performance and reducing aerodynamic noise (무선진공청소기 팬 모터 단품의 유량성능 향상과 공력소음 저감을 위한 임펠라 최적설계)

  • Kim, KunWoo;Ryu, Seo-Yoon;Cheong, Cheolung;Seo, Seongjin;Jang, Cheolmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.5
    • /
    • pp.379-389
    • /
    • 2020
  • In this study, the flow and noise performances of high-speed fan motor unit for cordless vacuum cleaner is improved by optimizing the impeller which drives the suction air through flow passage of the cordless vacuum cleaner. Firstly, the unsteady incompressible Reynolds averaged Navier-Stokes (RANS) equations are solved to investigate the flow through the fan motor unit using the computational fluid dynamics techniques. Based on flow field results, the Ffowcs-Williams and Hawkings (FW-H) integral equation is used to predict flow noise radiated from the impeller. Predicted results are compared to the measured ones, which confirms the validity of the numerical method used. It is found that the strong vortex is formed around the mid-chord region of the main blades where the blade curvature change rapidly. Given that vortex acts as a loss for flow and a noise source for noise, impeller blade is redesigned to suppress the identified vortex. The response surface method using two factors is employed to determine the optimum inlet and outlet sweep angles for maximum flow rate and minimum noise. Further analysis of finally selected design confirms the improved flow and noise performance.

Microencapsulation of Aster scaber and Aster glehni by Spyay Drying (분무건조법을 이용한 참취 및 섬쑥부쟁이 추출물의 미세캡슐화)

  • 강윤창;최경구;김공환;김현구
    • Food Science and Preservation
    • /
    • v.9 no.2
    • /
    • pp.212-220
    • /
    • 2002
  • Spray drying was used a means for microencapsulation of Aster scaber and Aster glehni. The optimum conditions of spray drying were found to be 210$^{\circ}C$ for the inlet temperature and 5 $m\ell$/min for the feeding rate. The color difference decreased by 12∼25 % far the herb extracts depending on storage temperatures. With an increase in storage temperature, color of the control changed considerably compared to microencapsulated powders. This is due to the fact that wall materials minimized effect of oxygen on the herb extracts. Microencapsulated powders in the amounts of 50 ppm and 250 ppm added to hydrogenated soybean oils led to lower acid values and conjugated diene values during 6 day storage. Compared to the control, the herb extracts displayed 16∼48% increase in antioxidation effect, while the microencapsulated powders exhibited 46∼88% increase. Extracts also showed lower conjugated dienoic acid contents than those of the control. Although antioxidation effect of the microencapsulated powders did not prevail on the significant level in the early stage of storage of oils tested, it became predominant after one week of storage as wall materials were gradually degraded under the high temperature thereby releasing core material from the microcapsule.

A Study on Shape Optimization and Hemolysis Evaluation of Axial Flow Blood Pump by Using Computational Fluid Dynamics Analysis (CFD해석을 이용한 축류형 혈액펌프의 용혈평가 및 형상개량에 관한 기초연구)

  • 김동욱;임상필
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.57-64
    • /
    • 2004
  • The non pulsation blood pump is divided into axial flow and centrifugal style according to the direction of inlet and outlet flow. An axial flow blood pump can be made smaller than a centrifugal blood pump because centrifugal pump's rpm is fewer than axial flow pump. Hemolysis is an important factor for the development of an axial flow blood pump. It is difficult to identify the areas where hemolysis occurs. Evaluation of hemolysis both in in-vitro and in-vivo test requires a long-time and more expensive. Computational fluid dynamics(CFD) analysis enables the engineer to predict hemolysis on a computer which just can get not only amount of htmolysis but also location of hemolysis. It takes shorter time and less expensive than in-vitro test. The purpose of this study is to git Computational fluid dynamics in axial flow pump and to verify the accuracy of prediction by the possibility of design comparing CFD results with in-vitro experimental results. Also, wish to figure out the correction method that can bring improvement in shape of axial flow blood pump using CFD analysis.

VOC/HAPs Emission Characteristics & Adsorption Evaluation for Paint Products in Busan Area (부산지역 페인트제조시설의 VOC/HAPs 배출특성 및 흡착능 평가)

  • Song, Bok-Joo;Lee, Seung-Min;Cho, Gab-Je;Cho, Jeong-Gu;You, Pyung-Jong;Kim, Gi-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2012
  • In this study, we suggested adequate control technology by analyzing emission process and main chemical of VOC/HAPs generated from four paint factories in Busan area. And we estimated whether Kapok fiber, which is a natural material, can be commercially used for an absorbent by testing adsorption ability. As a result of this sturdy, above 60% of VOC/HAPs was volatilized and dispersed inside the working place without conducting control system of facilities during manufacturing paints. Concentration profile of VOC/HAPs, which is volatile naturally outside the factories, is surveyed above 70% at Toluene, Ethylbenzene, and Xylene. And a result of evaluation of odor attribution level about the component whose Odor Threshold is known, it is estimated that major cause material of A, B, C factories is Toluene and that of D factory is m/p-Xylene. And that result presented design arguments such as facilities specifications, activated carbon filling volume, and replace cycle of activated carbon as control technology. Also, that result presented emission process improvement such as adsorption of central-controlled ventilation device, installation of inlet flenge, and potable cleaning process. The rate of pollutant adsorption of Kapok fiber, which is natural material, is indicated about 91.9%, 66.7%. That result validated the possibility as replacement of activated carbon.

Effect of fluoride concentration in pH 4.3 and pH 7.0 supersaturated solutions on the crystal growth of hydroxyapatite (pH 4.3과 pH 7.0의 과포화용액에서 불소의 농도가 합성 수산화인회석의 결정 성장에 미치는 영향)

  • Shin, Han-Eol;Park, Sung-Ho;Park, Jeong-Won;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.1
    • /
    • pp.16-23
    • /
    • 2012
  • Objectives: Present study was undertaken to investigate the crystal growth onto synthetic hydroxyapatite (HA) seeds in pH 4.3 and pH 7.0 supersaturated solutions with different fluoride concentrations. Materials and Methods: 8 groups of pH 4.3 and 7.0 calcium phosphate supersaturated solutions were prepared with different fluoride concentrations (0, 1, 2 and 4 ppm). Calcium phosphate precipitates yield crystal growth onto the HA seed surface while solutions flow. For evaluation of crystallizing process, the changes of $Ca^{2+}$, $PO{_4}^{3-}$, $F^-$ concentrations of the inlet and outlet solutions were determined. The recovered solid samples were weighed to assess the amount of minerals precipitated, and finally determined their composition to deduce characteristics of crystals. Results: During the seeded crystal growth, there were significantly more consumption of $Ca^{2+}$, $PO{_4}^{3-}$, $F^-$ in pH 4.3 solutions than pH 7.0 (p < 0.05). As fluoride concentration increased in pH 4.3 solution, $Ca^{2+}$, $PO{_4}^{3-}$, $F^-$ consumption in experimental solutions, weight increment of HA seed, and fluoride ratio in crystallized samples were increased. There were significant differences among the groups (p < 0.05). But in pH 7.0 solution, these phenomena were not significant. In pH 7.0 solutions, analyses of crystallized samples showed higher Ca/P ratio in higher fluoride concentration. There were significant differences among the groups (p < 0.05). But in pH 4.3 solution, there were not significant differences in Ca/P ratio. Conclusions: Crystal growth in pH 4.3 solutions was superior to that in pH 7.0 solutions. In pH 4.3 solutions, crystal growth increased with showed in higher fluoride concentration up to 4 ppm.

Identification of Cultivate Sites for Job's-tears (Coix lachrymajobi var. mayuen) using Capillary Electrophoresis (Capillary electrophoresis를 이용한 율무의 원산지 판별)

  • Rhyu, Mee-Ra;Kim, Eun-Young;Kim, Sang-Sook
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.787-791
    • /
    • 2002
  • Optimal extraction, separation, and capillary rinsing conditions for capillary electrophoresis (CE) were established to identify the cultivation site (domestic vs. foreign) of Job's-tears (Coix lachrymajobi var. mayuen) using 240 samples (domestic sample n = 121, foreign sample n = 119). Job's-tears was extracted with 30% ethanol and separated on a $50-{\mu}m-I.D.$ untreated fused-silica capillary. Optimal analytic conditions were: temperature, $45^{\circ}C$; voltage, 15 kV; detector rise time, 0.1 sec; and pressure injection, 20 sec. Separation of peak investigated using 0.1 M phosphate buffer (pH 2.5) containing 0.05% hydroxypropylmethylcellulose (P buffer) revealed the optimal separation buffer was P buffer containing 26 mM hexane sulfonic acid with 30% methanol. Under the optimal conditions established for CE, the average correct identification percentage of domestic or foreign Job's-tears was 82%.

Studies on the Combustion of Anthracite (I). Combustion of Carbon Monoxide and the Furface (無燃炭 燃燒에 關한 硏究 (第 1 報). 一酸化炭素 燃燒反應 및 燃燒裝置)

  • Shin Byoung Sik;Shin Sei Kun
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.3
    • /
    • pp.186-192
    • /
    • 1975
  • In the course of anthracite briquet combustion, air draft is usually controlled to continue burning of definite amount of briquet in the conventional hollow clay cylinder with air inlet hole open for given time, so that a large amount of CO tends to be produced. Therefore, it is necessary to establish an improved combustion process to depress the yielding rate of CO and for this purpose, we performed a basic experiment in which combustion rate of CO was measured in the mixture of $N_2, O_2 $and CO gas with or without the presence charcoal at the various temperature. The observed results showed that the burning temperature of CO is about 680${\sim}700^{\circ}C$, further burning rate of it was increased with increasing the amount of draft. From these facts, longer combustion time and low CO generation are thus contradictory to each other and it has been long desired to make those two compatible somehow. The purpose of the present investigation lies in designing an effective new briquet stove to meet the above requirements. The essential feature of the new briquet stove consisted in the use of two hollow iron cylinders with different inside diameter. A cylindrical air jacket thus formed served as a path through which small amount of secondary air run from the bottom of the stove to the upper vent holes. Heat exchange occurred between the upgoing secondary air and the burning briquet, which lowered the combustion temperature of the briquet. The results observed were selfevident as anticipated. It was confirmed that the combustion time was increased tolerably due to the heat loss from the combustion zone and that CO in the flue gas was reoxidized at the upper portion of the stove by the upgoing hot secondary air. By this reoxidation reaction the concentration of CO in the flue gas was found to be about 1/20 of that in case the conventional clay cylinder was used as briquet jacket.

  • PDF

Diagnosis of Performance Degradation of Direct Methanol Fuel Cell Stack after Long-Term Operation (장기운전에 의한 직접메탄올 연료전지 스택의 성능 열화 분석)

  • Kim, Sang-Kyung;Hyun, Min-Soo;Lee, Byung-Rok;Jung, Doo-Hwan;Peck, Dong-Hyun;Lim, Seong-Yop
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.775-780
    • /
    • 2011
  • 5-cell DMFC stack was fabricated and operated with the load of 4 A for 4000 hrs. After 4000 hrs operation peak power density of the stack reduced by 27.3%. Two of the five cells did now show performance degradation, the performance of other two was reduced by 40% and the performance of the other decreased by 60%. The amount of performance degradation of each cell by long-term operation did not correlate with the position in the stack. Platinum particle size in the anode catalyst layer of the MEA with the strongest degradation increased and the increase was severer on the position of methanol inlet than on the position of methanol outlet. However, platinum particle size in the cathode catalyst layers did not changed for all the MEA'. Ruthenium crossover from the anode catalyst layer to the cathode catalyst layer through the membrane was observed after 4,000 hrs operation by SEM-EDX and it occurred for all MEA' regardless of the degree of performance degradation. Atomic ratio of ruthenium to platinum in the cathode catalyst layer was the highest in the MEA with the strongest performance degradation.