• Title/Summary/Keyword: injection temperature

Search Result 1,929, Processing Time 0.03 seconds

Removal of Chlorinated Organic Compounds in Flue Gas by Activated Carbon Injection in a Semi-Drying Reactor (반건식 반응기에서의 활성탄 혼합주입에 의한 소각로 배가스중의 유기 염소계 화합물의 제거 공정 연구)

  • Choo, Changupp;Whang, Jaedong;Lee, Joyoung;Cho, Chulhoon;Shin, Byungchul
    • Clean Technology
    • /
    • v.6 no.2
    • /
    • pp.121-127
    • /
    • 2000
  • There are several kinds of hazardous materials in incinerator flue gas, such as particulate matter, acid gas, heavy metal, dioxin, etc. The activated carbon adsorption is considered as one of the methods removing dioxin from flue gas. Without any additional equipment and facilities, the activated carbon was mixed with lime and sprayed in the semi-drying reactor of an incinerator and filtered in the bag filter, and its efficiency of removing hazardous organic material was investigated. 1,2-dichlorobenzene (o-DCB) was used as a precursor material of dioxin and the effects of the activated carbon amount, the operating temperature of the reactor, and the atomizer r.p.m were measured and analyzed. Experimental results showed that the optimum outlet temperature of the reactor was $145^{\circ}C$ considering the performance of the bag filter, and the adsorption performance improved with the increase of the atomizer r.p.m. Also the performance of removing o-DCB in the bag filter is higher than of the semi-drying reactor.

  • PDF

A Study on the Activated Carbon Injection and Filtration Process for Removal of Chlorinated Organic Compound in the Incinerator Flue Gas (활성탄의 분무 여과에 의한 소각로 배가스 중의 유기 염소계 화합물의 제거 공정 연구)

  • Choo, Changupp;Whang, Jaedong;Lee, Joyoung;Cho, Chulhoon;Shin, Byungchul
    • Clean Technology
    • /
    • v.6 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Due to the toxicity of dioxin in the incinerator flue gas, it becomes a severe social problem. Activated carbon adsorption process is one of the methods for removing dioxin in the flue gas and was investigated its performance for removing hazardous organic compounds. Since dioxin is very hazardous material, 1,2-dichlorobenzene(o-DCB), one of the precursor material of dioxin, was used as adsorbate. The effects of air flow rate, pressure drop in the bag filter, operation temperature of bag filter, and kinds of adsorbents on the removal of o-DCB were measured and analysed. Experimental results showed that the operating temperature was recommended within the range of $140{\sim}170^{\circ}C$ considering the operating condition of incinerator. Also it was necessary to maintain the pressure drop of bag filter $120mmH_2O$ for enhancing the adsorption at the surface layer of activated carbon formed on the bag filter. The use of mixture of same amount of activated carbon and diatomite showed more than 90% removal of o-DCB and also reduced the consumption of activated carbon.

  • PDF

A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type (하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

Effects of Prunellae Spica Extract on LT4-induced Hyperthyroidism in Rats through the Regulation of Heat and Cold Imbalance (하고초추출물의 갑상선기능항진증 랫트모델에서의 한열조절작용에 의한 개선효능 연구)

  • Kang, An Na;Kang, Seok Yong;Meng, Xianglong;Ma, Junnan;Park, Jong Hun;Park, Yong-Ki
    • The Korea Journal of Herbology
    • /
    • v.33 no.4
    • /
    • pp.77-85
    • /
    • 2018
  • Objective : This study was intended to examine the effects of water extract of Prunellae Spica (PS), which is a herb with 'cold' nature based on hot and cold theory of traditional Korean medicine. Methods : Hyperthyroidism was induced in SD rats by LT4 (0.5 mg/kg, i.p.) daily for four weeks. After 2 weeks of LT4 injection, rats were divided randomly into four groups; normal, LT4-induced hyperthyroid control, PS extract (500 mg/kg, p.o.)-treated group, and propylthiouracil (PTU, 10 mg/kg, s.c.)-treated positive group. After 2 weeks of drug treatment, all rats were sacrificed and harvested blood samples and thyroid tissues. The changes of body weight, food and water intake, and body temperature were measured weekly. Serological markers were analyzed in sera using an enzyme-based assay, and thyroid tissues were stained with Hematoxylin & Eosin (H&E). Brain and dorsal root ganglion (DRG) tissues were isolated and analyzed the expression of transient receptor potential (TRP) channels by Western blot. Results : PS extract administration attenuated the loss of body weight and the increase of body temperature in LT4-induced hyperthyroidism rats. PS extract increased the level of thyroid stimulating hormone (TSH) and decreased tiiodothyronine (T3) and tetraiodothyronine (T4). In action mechanism, PS extract regulated the expression of transient receptor potential channel subfamily V member 1 (TRPV1) and transient Receptor Potential channel subfamily M member 8 (TRPM8), the thermoregulators. Conclusion : To conclude, PS extract can improve the symptoms of hyperthyroidism through regulation of the thyroid hormones imbalance and thermoregulation via TRP channels.

Determination of VOC in aqueous samples by the combination of headspace (HS) and solid-phase microextraction (SPME) (HS-SPME 방식에 기초한 물 중 VOC 성분의 분석기법에 대한 연구: 3가지 실험 조건의 변화와 분석감도의 관계)

  • Park, Shin-Young;Kim, Ki-Hyun;Yang, H.S.;Ha, Joo-Young;Lee, Ki-Han;Ahn, Ji-Won
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.93-101
    • /
    • 2008
  • The application of solid phase microextraction (SPME) is generally conducted by directly immersing the fiber into the liquid sample or by exposing the fiber in the head space (HS). The extraction temperature, the time of incubation, and application of stirring are often designated to be the most important parameters for achieving the best extraction efficiencies of HS-SPME analysis. In this study, relative importance of these three analytical parameters involved in the HS-SPME method is evaluated using a polydimethylsiloxane/carboxen (PDMS/CAR) fiber. To optimize its operation conditions the competing relationships between different parameters were investigated by comparing the extraction efficiency based on the combination of three parameters and two contracting conditions: (1) heating the sample at 30 vs. 50 C, (2) exposing samples at two durations of 10 vs. 30 min, and (3) application of stirring vs. no stirring. According to our analysis among 8 combination types of HS-SPME method, an extraction condition termed as S50-30 condition ((1) 1200 rpm stirring, (2) $50^{\circ}C$ exposure temp, and (3) 30 min exposure duration) showed maximum recovery rate of 45.5~68.5% relative to an arbitrary reference of direct GC injection. According to this study, the employment of stirring is the most crucial factor to improve extraction efficiency in the application of HS-SPME.

Evaluation of Cryptosporidiurn Disinfection by Ozone and Ultraviolet Irradiation Using Viability and Infectivity Assays (크립토스포리디움의 활성/감염성 판별법을 이용한 오존 및 자외선 소독능 평가)

  • Park Sang-Jung;Cho Min;Yoon Je-Yong;Jun Yong-Sung;Rim Yeon-Taek;Jin Ing-Nyol;Chung Hyen-Mi
    • Journal of Life Science
    • /
    • v.16 no.3 s.76
    • /
    • pp.534-539
    • /
    • 2006
  • In the ozone disinfection unit process of a piston type batch reactor with continuous ozone analysis using a flow injection analysis (FIA) system, the CT values for 1 log inactivation of Cryptosporidium parvum by viability assays of DAPI/PI and excystation were $1.8{\sim}2.2\;mg/L{\cdot}min$ at $25^{\circ}C$ and $9.1mg/L{\cdot}min$ at $5^{\circ}C$, respectively. At the low temperature, ozone requirement rises $4{\sim}5$ times higher in order to achieve the same level of disinfection at room temperature. In a 40 L scale pilot plant with continuous flow and constant 5 minutes retention time, disinfection effects were evaluated using excystation, DAPI/PI, and cell infection method at the same time. About 0.2 log inactivation of Cryptosporidium by DAPI/PI and excystation assay, and 1.2 log inactivation by cell infectivity assay were estimated, respectively, at the CT value of about $8mg/L{\cdot}min$. The difference between DAPI/PI and excystation assay was not significant in evaluating CT values of Cryptosporidium by ozone in both experiment of the piston and the pilot reactors. However, there was significant difference between viability assay based on the intact cell wall structure and function and infectivity assay based on the developing oocysts to sporozoites and merozoites in the pilot study. The stage of development should be more sensitive to ozone oxidation than cell wall intactness of oocysts. The difference of CT values estimated by viability assay between two studies may partly come from underestimation of the residual ozone concentration due to the manual monitoring in the pilot study, or the difference of the reactor scale (50 mL vs 40 L) and types (batch vs continuous). Adequate If value to disinfect 1 and 2 log scale of Cryptosporidium in UV irradiation process was 25 $mWs/cm^2$ and 50 $mWs/cm^2$, respectively, at $25^{\circ}C$ by DAPI/PI. At $5^{\circ}C$, 40 $mWs/cm^2$ was required for disinfecting 1 log Cryptosporidium, and 80 $mWs/cm^2$ for disinfecting 2 log Cryptosporidium. It was thought that about 60% increase of If value requirement to compensate for the $20^{\circ}C$ decrease in temperature was due to the low voltage low output lamp letting weaker UV rays occur at lower temperatures.

Ecological Study of Narrow-mouthed Toad (Kaloula borealis) Population at Myeongji District in Busan Metropolitan City (부산시 명지지구에 서식하는 맹꽁이 개체군 생태연구)

  • Hong, Sung-Gu;An, Chi-Kyung;Kim, Hyun-jung;Oh, Ki Cheol;Park, Sun Young;Na, Sumi;Yi, Hoonbok
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.172-179
    • /
    • 2017
  • The purpose of this study is to analyze the current original habitat and to conserve the narrow-mouthed toad populations. For this study, we used 240 pitfall traps (30 cm height ${\times}$ 20 cm width) to catch the narrow-mouthed toads that inhabit in Myeongji-dong, Gangseo-gu, in Busan metropolitan city from August 2, 2013 to November 7, 2013. We measured the environmental characteristics (soil composition factors, soil moisture, Humidity, soil temperature) for the seven habitat patterns of narrow-mouthed toads based on vegetation types. Main habitats of narrow mouthed toads were flat grassland where grass and false acacia grew and there was wetland all over the place. When analyzing habitats that main habitats of narrow-mouthed toads prefer after selecting representative seven vegetation, it was found that the most narrow-mouthed toads were caught in amur silver grass colony while the least narrow-mouthed toads were caught in bare land. Totally, we caught 846 narrow-mouthed toads over 68 times, and released them into the newly constructed habitat after injection VIE-tag. It seems that the reason for which the least narrow mouthed toads were caught in bare land is that bare land is not suitable for narrow mouthed toads to protect themselves from strong sunlight and to hide themselves from natural enemy. We found that temperature had the greatest influence on activities of narrow mouthed toads and at temperature of less than $15.6^{\circ}C$. We also found that the activities of narrow mouthed toads were remarkably low and then temperature was below $15.6^{\circ}C$. It meant that narrow mouthed toads seemed to go into hibernation. From this research, we could find the prefer habitat after analyzing habitats for the narrow-mouthed toads and could suggest for construction for the better habitat of narrow-mouthed toads.

Effects of Temperature and Saturation on the Crystal Morphology of Aragonite (CaCO3) and the Distribution Coefficient of Strontium: Study on the Properties of Strontium Incorporation into Aragonite with respect to the Crystal Growth Rate (온도와 포화도가 아라고나이트(CaCO3)의 결정형상과 스트론튬(Sr)의 분배계수에 미치는 영향: 결정성장속도에 따른 아라고나이트 내 스트론튬 병합 특성 고찰)

  • Lee, Seon Yong;Chang, Bongsu;Kang, Sue A;Seo, Jieun;Lee, Young Jae
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.2
    • /
    • pp.133-146
    • /
    • 2021
  • Aragonite is one of common polymorphs of calcium carbonate (CaCO3) and formed via biological or physical processes through precipitation in many different environments including marine ecosystems. It is noted that aragonite formation and growth as well as the substitution of trace elements such as strontium (Sr) in the aragonite structure would be dependant on several key parameters such as concentrations of chemical species and temperature. In this study, properties of the incorporation of Sr into aragonite were investigated over a wide range of various saturation conditions and temperatures similar to the marine ecosystem. All pure aragonite samples were inorganically synthesized through a constant-addition method with varying concentrations of the reactive species ([Ca]=[CO3] 0.01-1 M), injection rates of the reaction solution (0.085-17 mL/min), and solution temperatures (5-40 ℃). Pure aragonite was also formed even under the Sr incorporation conditions (0.02-0.5 M, 15-40 ℃). When temperature and saturation index (SI) with respect to aragonite increased, the crystallinity and the crystal size of aragonite increased indicating the growth of aragonite crystal. However, it was difficult to interpret the crystal growth rate because the crystal growth rate calculated using BET-specific surface area was significantly influenced by the crystal morphology. The distribution coefficient of Sr (KSr) into aragonite decreased from 2.37 to 1.57 with increasing concentrations of species (Ca2+ and CO32-) at a range of 0.02-0.5 M. Similarly, it was also found that KSr decreased 1.90 to 1.54 at a range of 15-40 ℃. All KSr values are greater than 1, and the inverse correlation between the KSr and the crystal growth rate indicate that Sr incorporation into aragonite is in a compatible relationship.

ON THE CHARACTERISTICS OF EGGS AND LARVA OF MYLIO MACROCEPHALUS (BASILEWSKY) (감성돔 Mylio macrocehalus (Basilewsky)의 난 및 부화자어의 특성에 대하여)

  • Kim Yong Uk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.3 no.4
    • /
    • pp.233-250
    • /
    • 1970
  • The present paper deals with the results of the observations on the characteristics of the eggs being ripen by injection of synahorin and the larvae of the black porgy. Mylio macrocehalus (Basilewsky). The adult fish used in the experiments, during May 11th to June 5th, 1970, were obtained from a fish-farm of the Atsumi Fish Culture Company in Aichi Prefecture, Japan, The results obtained are as follows: 1. The egg is colorless and buoyant, spherical in shape, measuring from $0.81\~0.96\;mm$ in dia-meter with a single oil globule, measuring $0.20\~0.23\;mm$. 2. Hatching took place within about 35 hours and 50 minutes after insemination of eggs at the water temperature $19.6\~22.5^{\circ}C$ (Mean, $20.6^{\circ}$). 3. The newly hatched larvae were 1.57 mm in total length, with the oil globule situated at the posterior part of the elongated oval-shaped yolk sac. Melanophores and xanthophores were distributed on the middle of the caudal region, and were scattered on the surface of the oil globule, but none on the yolk sac. 4. The diameter of the eggs ill each adult is distinguished into two types, large and small. The former is in the range of $0.811\~0.873\;mm$, the latter is $0.874\~0.963\;mm$. 3. The hatching rate of black porgy was in the range of $78.63\~95.19\%$ in large and $68.84\~74.80\%$ in small eggs. The mean hatching rate of total eggs was $79.80\%$. 6. The optimum temperature of hatching black porgy is in the range of $20\~26^{\circ}C$. The highest temperature limit of hatching the black porgy is from $26.71\~28.56^{\circ}C$. 7. The total length of hatched larvae is not maintained pararell to diameter of eggs and total length of the large larvae is from $1.976\~2.225mm$, and that of small larvae is $1.526\~1.90mm$. 8. The diameter of yolk sac of black porgy is in the range of $0.878\~0.979\;mm$ 9. The initial survived larva of the black porgy was $13.71\%$ in minimum, and $79\%$ in maximam. And the mean initial survived rate was $48.3\%$. 10. In conclusion, the biological characteristics of hatched larva of black porgy is seemed to be possible for large scale production of artificial seedlings. But experimental results make initial food the prime object believed to be supplemented.

  • PDF

Development of a Vertical Multi-stage Ammonia Stripping Reactor for Recovering Ammonia from wastewater with High Nitrogen Concentrations(I) (고농도 질소폐수로부터 암모니아 회수를 위한 다단수직형 암모니아스트리핑조 개발(I))

  • Lee, Jae Myung;Choi, Hong-bok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.2
    • /
    • pp.41-48
    • /
    • 2017
  • A vertical multi-stage ammonia stripping reactor using E-PFR, which has been proved to be superior in anaerobic and aerobic treatment, was developed and a lab scale experiment was conducted. According to the change of stage number condition, the removal rate of the ammonia nitrogen in the reactor with 0-stage was about 52.5% after 8 hours (pH 10, temperature $35^{\circ}C$, and the air/liquid ratio $3min^{-1}$) However, in the reactor with 5-stage, the removal efficiency was about 62.6%. According to the change of pH condition, the removal rate of ammonia nitrogen was about 42.6% at pH 9 after 8 hours, and was about 74.4% at pH 11 (5-stage reactor, temperature $35^{\circ}C$, and the air/liquid ratio $3min^{-1}$). According to the change of temperature condition, the removal rate of the ammonia nitrogen was about 51% at $25^{\circ}C$ after 8 hours (5-stage reactor, pH 10, and the air/liquid ratio $3min^{-1}$), and was about 87.2% at $45^{\circ}C$. According to the change of air injection volume condition, the removal rate of the ammonia nitrogen was about 45.8% at $2min^{-1}$ after 8 hours (5-stage reactor, pH 10, and at $35^{\circ}C$). and was about 75% at $4min^{-1}$. Based on these results, we will follow up the applicability of the actual plant in the future through continuous operation evaluation.