• 제목/요약/키워드: injection pressure P

검색결과 205건 처리시간 0.022초

개에서 초자체내 겐타마이신 주사의 영향 (Effects of Intravitreal Centamicin Injection on the Clinically Normal Canine Eye)

  • 강선미;이충호;김완희;우흥명;권오경
    • 한국임상수의학회지
    • /
    • 제19권3호
    • /
    • pp.333-336
    • /
    • 2002
  • This experiment was carried out to investigate the optimal dose of intravitreal gentamicin that decreases intraocular pressure effectively and minimizes complications in dog. After inhalation anesthesia, gentamicin was injected intravitreally into the left eyes at doses of 10, 15 and 20 mg with 1 mg dexamethasone, respectively. Sterilized isotonic saline and dexamethasone mixture into the right eyes for control. Six dogs were used in each group. Intraocular pressures were measured using applanation tonometer(Mentore, Tono-Pen) until 5 months after injection of gentamicin. Ocular examinations were performed using direct ophthalmoscopy. The ocular volumes of both eyes were measured. Intraocular pressures of eyes injected with 10. 15 and 20 mg of gentamicin were decreased significantly compared with control eyes. Severe corneal opacity and neovascularization occurred in 20 mg treated group. Intraocular hemorrhage was observed in 3 dogs of 20 mg treated group. Ocular volume was significantly decreased(p <0.05) in 20 mg treated group, compared with 10 and 15 mg treated group. It is considered that intravitreal gentamicin injection at dose of 10 mg or 15 mg decrease intraocular pressure effectively and minimize complications such as corneal opacity, hyphema and phthisis bulbus.

그라우팅자동관리시스템을 이용한 액상화 방지 그라우팅의 적용 (Application of Grouting for Liquefaction Resistance Using Automatic Grouting System)

  • 공진영;강준오;조현수;김진춘;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제12권9호
    • /
    • pp.79-87
    • /
    • 2011
  • 기존의 액상화 방지를 위한 그라우팅은 부정확한 계측장비를 사용하고 시공 품질관리를 경험에 의존하는 단점이 있다. 본 연구는 ${\bigcirc}{\bigcirc}{\bigcirc}$ 고속도로 건설현장 내 말뚝기초 주변의 지반을 그라우팅으로 보강한 사례를 분석하여 액상화 대책공법으로서 그라우팅 보강효과에 대한 연구를 실시하였다. p-q-t 도표 유형분석을 통해서 결정된 주입압, 주입속도 및 주입대상지반의 입도특성, 주입재의 점도특성으로부터 도출한 결과를 그라우팅 자동관리시스템에 적용하여 그라우팅의 주입효과를 높였다. 주입 후 SPT 시험을 실시한 결과 N값이 5-20까지 증가하여 액상화에 대하여 안전한 것으로 나타났다.

인공신경망을 활용한 최적 사출성형조건 예측에 관한 연구 (A Study on the Prediction of Optimized Injection Molding Condition using Artificial Neural Network (ANN))

  • 양동철;이준한;윤경환;김종선
    • 소성∙가공
    • /
    • 제29권4호
    • /
    • pp.218-228
    • /
    • 2020
  • The prediction of final mass and optimized process conditions of injection molded products using Artificial Neural Network (ANN) were demonstrated. The ANN was modeled with 10 input parameters and one output parameter (mass). The input parameters, i.e.; melt temperature, mold temperature, injection speed, packing pressure, packing time, cooling time, back pressure, plastification speed, V/P switchover, and suck back were selected. To generate training data for the ANN model, 77 experiments based on the combination of orthogonal sampling and random sampling were performed. The collected training data were normalized to eliminate scale differences between factors to improve the prediction performance of the ANN model. Grid search and random search method were used to find the optimized hyper-parameter of the ANN model. After the training of ANN model, optimized process conditions that satisfied the target mass of 41.14 g were predicted. The predicted process conditions were verified through actual injection molding experiments. Through the verification, it was found that the average deviation in the optimized conditions was 0.15±0.07 g. This value confirms that our proposed procedure can successfully predict the optimized process conditions for the target mass of injection molded products.

사출성형 CAE를 이용한 세탁기용 Base 성형용 금형의 유동 시스템 최적화 (Optimization of feed system of base mold for washing machine using CAE)

  • 유민지;김경아;한성렬
    • Design & Manufacturing
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2021
  • The position of the gate is one of the important factors for optimal injection molding. This is because inappropriate gate positions cannot fill the cavity uniformly, which can lead to defects such as contraction. In this study, CAE was performed on hot runner injection molding of the washing machine base and plasticity was compared by changing gate position from existing gate position. A total of two alternatives have been applied to compare the plasticity of the washing machine base according to its optimal gate position. The gate position of the improved molds and the gate position of the current mold is analyzed by injection molding analysis. The results of the fill time, the pressure at V/P switchover, clamping force, and deflection were compared. In washing machine base injection molding, the deflection was reduced by about 3.76% in the improved mold 2. In improved mold 1, the fill time during injection molding was reduced by 3.32% to enable uniform charging, and the clamping force was reduced by 31.24%. We have confirmed that the position of the gate can change the charging pressure and the clamping force and affect the quality and cost savings of the molded product.

Yohimbine과 Atipamezole이 Xylazine-Ketamine 병용 마취견의 뇌파에 미치는 영향 (Effects of Yohimbine and Atipamezole in Dogs Anesthetized with Xylazine-Ketamine Combination on EEG)

  • 장환수;장광호;이만기;장인호
    • 한국임상수의학회지
    • /
    • 제19권2호
    • /
    • pp.174-185
    • /
    • 2002
  • We investigated the effects of yohimbine and atipamezole in dogs anesthetized with xylazine-ketamine combination on electroencephalography (EEG) . Experiment groups were divided into three according to antagonists . Saline (1 ml) was used as an antagonist in group C, yohimbine (0.1 mg/kg) in group Y and atipamezole (50 ug/kg) in group A. Each group consisted of 5 dogs. Glycopyrrolate was injected 15 minutes prior to xylazine injection. Xylazine (1.1 mg/kg, IM) and ketamime (10 mg/kg, IV) were injected with the interval of 10 minutes. After 15 minutes, antagonists were administered intravenously. For EEG measurements, a recording electrode was positioned at Cz, which was applied to International 10-20 system. Heart rates, body temperature, respiratory rates, arterial blood pressure, $PaO_2$$PaCO_2$$PaCO_2$ at S4 in group Y was significantly decreased(p<0.05). Changes of electrolytes were not significant, except value of $Cl^-$ at S3 in group A. Mean head-up time (the time dogs showing head-up movement after antagonist injection, minutes) was $38.23^{\circ}$ae6.46 in group C, 2.54 $\pm$ 0.93 in group Y and 2.12$\pm$ 1.32 in group A. Mean sternal recumbent time (the time dogs showing sternal recumbency after antagonist injection, minutes) was 45.93$\pm$ 10.27 in group C, 11.91 $\pm$ 7.19 in group Y and 9.88$\pm$ 3.38 in group A. Mean walking time (minutes) was 53.49$\pm$ 9.21 in group C, 22.10$\pm$ 11.10 in group Y and 18.48$\pm$ 4.39 in group A. In group Y all dogs showed excitation and muscle rigidity in emergence. In group A, two dogs were also showed excitation and muscle rigidity, but were weaker than those of group Y.

저압 SCR을 위한 디젤발전기 배기가스 온도 변화 (Temperature Variation of Exhaust Gas in Diesel Generator for Low Pressure SCR)

  • 홍철현;이창민;이상득
    • 해양환경안전학회지
    • /
    • 제27권2호
    • /
    • pp.355-362
    • /
    • 2021
  • L.P SCR의 촉매 반응을 위해 선박의 발전기용 4행정 디젤엔진의 배기가스 온도를 높게 설계 할 수밖에 없었다. 본 연구의 목적은 밸브개폐시기와 연료분사시기를 조정을 통한 배기가스의 온도 감소가 L.P SCR의 운전조건을 만족시키고 고온으로 인한 발전기 엔진의 사고를 예방하기 위함이었다. 배기가스 온도를 하강시키기 위해 캠샤프트의 각도를 조정하고 연료분사펌프의 Shim을 추가하였다. 그 결과 최대폭발압력은 12.8 bar 증가하였고 터보차저 출구온도 평균값은 13.3 ℃ 하강하였다. 터보차저 출구에서 SCR 입구까지의 열손실을 감안하더라도 L.P SCR 운전조건인 SCR 챔버 입구 온도인 290 ℃를 만족하였다. 배기가스 온도 하강을 통해 디젤발전기의 안전운전이 가능하게 한 연구였다.

Hemodynamic changes and pain perception-related anxiety after experiencing an impacted-tooth removal: clinical practice outcome

  • Raocharernporn, Somchart;Boonsiriseth, Kiatanant;Khanijou, Manop;Wongsirichat, Natthamet
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제17권2호
    • /
    • pp.105-111
    • /
    • 2017
  • Background: Dental fear is usually associated with hemodynamic changes. Fear of pain during the surgical removal of a lower impacted third molar might cause patients anxiety, thereby leading to avoidance of any future dental therapy. This study aimed to determine the effect of experiencing a surgical impacted-tooth removal on the pain perception-related anxiety and hemodynamic status. Method: Twenty-seven healthy patients aged 15-30 years (mean age, 24 years), for whom surgical removal of bilateral lower third molars was advised, were included. This prospective, randomized, controlled, split-mouth study involved operations on both sides of the mandibular arch, with a 1-month washout period in between. Blood pressure and heart rate were measured before the surgical procedure, during and after the injection, preoperatively, and postoperatively. Pain perception was evaluated using a 100-mm visual analog scale during the injection, preoperatively, and postoperatively after the numbness disappeared. Differences in the blood pressure, heart rate, and pain perception between the two appointments were analyzed using the paired t-test. For all statistical analyses, SPSS version 11.5 was used. Results: The mean pain perception values during the injection and preoperatively showed no significant differences between the two appointments (P > 0.05); however, significant differences in the blood pressure and heart rate were noted before the surgical procedure; preoperatively, the blood pressure alone showed a significant difference (P < 0.05). Conclusion: There was a significant decrease in the blood pressure and heart rate preoperatively; hence, experiencing a surgical impacted-tooth removal can reduce the subsequent preoperative anxiety in healthy patients.

The Study of Emission Characteristics of Biodiesel Fuel in Diesel Engines

  • Yeom, Jeong-Kuk
    • 동력기계공학회지
    • /
    • 제19권1호
    • /
    • pp.56-63
    • /
    • 2015
  • In this study, the exhaust characteristics of the diesel engine for the change of the mixing ratio of biodiesel fuel were quantitatively analyzed by using the numerical analysis method. As the fuel used in the experiment, the diesel and biodiesel(waste oil, soybean oil), the mixed fuel BD2(Diesel only), BD3, BD5, BD20, BD50 and BD100 were used. The injection pressure($p_{inj}$) was set to 400bar, 600bar, 800bar, 1000bar and 1200bar as the experimental variable. Also the concept of the standard deviation, Pearson's correlation coefficient and Spearman rank-order correlation coefficient based on the statistics was introduced in order to analyze the exhaust characteristics of the quantitative NOx and Soot according to the injection pressure and the mixing ratio variation of biodiesel blending fuel. It is considered that as a result of studies, for the waste oil, NOx and Soot can be simultaneously reduced through control of the mixing ratio at the regions of $p_{inj}=400bar$ and $p_{inj}=600bar$, and the Soot can be reduced without affecting on the emission of NOx at more than $p_{inj}=800bar$. For the soybean oil, NOx and Soot can be simultaneously reduced at $p_{inj}=400bar$ and the Soot can be reduced without affecting on the emission of NOx at $p_{inj}=600bar$.

Effects of Remote Ischemic Pre-Conditioning to Prevent Contrast-Induced Nephropathy after Intravenous Contrast Medium Injection: A Randomized Controlled Trial

  • Dihia Belabbas;Caroline Koch;Segolene Chaudru;Mathieu Lederlin;Bruno Laviolle;Estelle Le Pabic;Dominique Boulmier;Jean-Francois Heautot;Guillaume Mahe
    • Korean Journal of Radiology
    • /
    • 제21권11호
    • /
    • pp.1230-1238
    • /
    • 2020
  • Objective: We aimed to assess the effects of remote ischemic pre-conditioning (RIPC) on the incidence of contrast-induced nephropathy (CIN) after an intravenous (IV) or intra-arterial injection of contrast medium (CM) in patient and control groups. Materials and Methods: This prospective, randomized, single-blinded, controlled trial included 26 patients who were hospitalized for the evaluation of the feasibility of transcatheter aortic valve implantation and underwent investigations including contrast-enhanced computed tomography (CT), with Mehran risk scores greater than or equal to six. All the patients underwent four cycles of five minute-blood pressure cuff inflation followed by five minutes of total deflation. In the RIPC group (n = 13), the cuff was inflated to 50 mm Hg above the patient's systolic blood pressure (SBP); in the control group (n = 13), it was inflated to 10 mm Hg below the patient's SBP. The primary endpoint was the occurrence of CIN. Additionally, variation in the serum levels of cystatin C was assessed. Results: One case of CIN was observed in the control group, whereas no cases were detected in the RIPC group (p = 0.48, analysis of 25 patients). Mean creatinine values at the baseline, 24 hours after injection of CM, and 48 hours after injection of CM were 88 ± 32 μmol/L, 91 ± 28 μmol/L and 82 ± 29 μmol/L, respectively (p = 0.73) in the RIPC group, whereas in the control group, they were 100 ± 36 μmol/L, 110 ± 36 μmol/L, and 105 ± 34 μmol/L, respectively (p = 0.78). Cystatin C values (median [Q1, Q3]) at the baseline, 24 hours after injection of CM, and 48 hours after injection of CM were 1.10 [1.08, 1.18] mg/L, 1.17 [0.97, 1.35] mg/L, and 1.12 [0.99, 1.24] mg/L, respectively (p = 0.88) in the RIPC group, whereas they were 1.11 [0.97, 1.28] mg/L, 1.13 [1.08, 1.25] mg/L, and 1.16 [1.03, 1.31] mg/L, respectively (p = 0.93), in the control group. Conclusion: The risk of CIN after an IV injection of CM is very low in patients with Mehran risk score greater than or equal to six and even in the patients who are unable to receive preventive hyperhydration. Hence, the Mehran risk score may not be an appropriate method for the estimation of the risk of CIN after IV CM injection.

금형 급속 가열-냉각이 적용된 이색사출성형의 플래쉬 발생 예측 (Prediction of Flash Generation in Two-Color Injection Molding using The Rapid Heat Cycle Molding Technology)

  • 박형필;차백순;이병옥
    • 소성∙가공
    • /
    • 제19권3호
    • /
    • pp.145-151
    • /
    • 2010
  • In case of thin-wall two-color injection molding, flashing often occurs when molten polymer flows into small gap at the parting line in mold with high pressure or under the unbalanced clamping force condition. In this study, flashing was examined in the production of thin-wall notebook case with large area when the rapid heat cycle molding (RHCM) technology was applied to the two-color injection molding. The effects of the RHCM technology on the part properties and weld-lines were compared with conventional injection molding. The flashing caused by the clamping device of the two-color injection molding machine was examined and compared by experiments and CAE analyses.