• Title/Summary/Keyword: initial line current

Search Result 83, Processing Time 0.025 seconds

A Study on the Analysis of Multi-let Spread Mooring Systems (다점지지 계류시스템의 정적해석에 대한 연구)

  • Sin, Hyeon-Gyeong;Kim, Deok-Su
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.53-60
    • /
    • 1995
  • A multi-leg spread mooring system for floating offshore structures is important, but the multi-leg static analysis is complicated due to the nonlinear behavior of each line and the effect of current which affects each line differently. The pretensioned position of the multi-leg mooring system obtained from the static equilibrium condition changes into a different position due to external loads and current. In this paper, the new position and the static tension at each line are caculated. The relation between the initial static equilibrium position and the new position due to the external loads is expressed in terms of the Taylor's series expansion. The Runge-Kutta $4^{th}$ method is employed in analyzing the 3-dimensional static cable nonlinear equations.

  • PDF

Initial Firing Angle Control of Parallel Multi-Pulse Thyristor Dual Converter for Urban Railway Power Substations

  • Kim, Sung-An;Han, Sung-Wo;Cho, Yun-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.674-682
    • /
    • 2017
  • This paper presents an optimal initial firing angle control based on the energy consumption and regenerative energy of a parallel multi-pulse thyristor dual converter for urban railway power substations. To prevent short circuiting the thyristor dual converter, a hysteresis band for maintaining a zero-current discontinuous section (ZCDS) is essential during mode changes. During conversion from the ZCDS to forward or reverse mode, the DC trolley voltage can be stabilized by selecting the optimal initial firing angle without an overshoot and slow response. However, the optimal initial firing angle is different depending on the line impedance of each converter. Therefore, the control algorithm for tracking the optimal initial firing angle is proposed to eliminate the overshoot and slow response of DC trolley voltage. Simulations and experiments show that the proposed algorithm yields the fastest DC voltage control performance in the transient state by tracking the optimal firing angle.

The Design of Cryogenic System for KSTAR TOKAMAK (KSTAR TOKAMAK을 위한 저온시스템의 설계)

  • 김동락;오영국;정영수;이정민;최창호;임기학;허남일;김양수;박영민
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.48-49
    • /
    • 2001
  • Cryogenic technology is one of the key technologies for fusion reactor equipped with superconducting coil for plasma confinement. The KSTAR(Korea Superconducting Tokamak Advanced Research)Project is in progress since 1996. Major parameters of the KSTAR tokamak are : major radius 1.8m, minor radius 0.5m, toroidal field 3.5 Tesla and plasma current 2MA with a strongly shaped plasma cross-section and double -null diverter. Considering practical engineering constraints, the KSTAR device is designed for a pulse length of 300 sec in up-graded operation mode but in the initial configuration would provide a pulse length of 20 sec provided by the poloidal coil system in base-line operation mode. The cryogenic system is composed as follows : cold box, helium compressor system, distribution box, helium gas buffer tank, helium gas purifying system, gas recovery system, liquid helium storage dewar, current lead box, current bus line and liquid nitrogen storage tank.

  • PDF

Surface Aging Properties of Silicon Rubber Insulator by salt-fog (Silicon rubber 애자의 salt-fog 표면열화 특성)

  • 이종찬;이운용;조한구;박대희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.255-257
    • /
    • 2001
  • In this paper, the silicon rubber insulator for transmission line was experimented for 1,000 hours aging test in salt-fog condition. To evaluate and examine the aging properties of silicon rubber insulator for test, the leakage current of surface was measured. Also hydrophobicity and scanning electron microscopy were compared with initial and aged sample respectively Above results, we can confirm that the surface properties of silicon rubber insulator easily aged by salt-fog condition.

  • PDF

A Study of Seam Tracking by Arc Sensor Using Current Area Difference Method (전류 면적차를 이용한 아크 센서의 용접선 추적에 관한 연구)

  • 김용재;이세헌;엄기원
    • Journal of Welding and Joining
    • /
    • v.14 no.6
    • /
    • pp.131-139
    • /
    • 1996
  • The response of the arc sensor using the welding current and/or welding voltage as its outputs has been obtained by the analysis and/or experiments of the static characteristics of arc sensor. But in order to improve the reliability of arc sensor, it is necessary to know its dynamic characteristics. So in this paper, it is presented the dynamic model of arc sensor including the power source, arc voltage, electrode burnoff rate, and wire feed rate. A numerical simulation of the dynamic model of arc sensor was implemented, computing the welding current with input of CTWD. The results of computer simulations and experiments of $CO_2$arc welding showed that a linear relationship between weaving center - weld line distance and current area difference was established. Additionally, a real-time weld seam tracking system interfaced with industrial welding robot was constructed, the result of the weld seam tracking experiment for weld line with an initial offset error of 5$^{\circ}$was good.

  • PDF

A Study on Power Line Carrier System Using Spread Spectrum Technique. (확산대역 통신 방식을 이용한 전력선 반송 시스템에 관한 연구)

  • Huh, Young;Choi, Hyun-Ho;Oh, Sang-Ki;Kim, Kawn-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.841-845
    • /
    • 1991
  • There are Carrier Current Communication or Power line Carrier (PLC) Communication conducted data exchange using power line Which is installed existing indoor. Power line is possible to construct data link economically, on the other hand, have an inferior transmission environment such as irregular noise and severe level variation. The purpose of this paper is to present transmission possibility for PLC using spread spectrum technique. In the initial synchronization, established computer simulation for the S/N in relation to PN code generator. By using this result, construct the prototype SS system and then experiment the transmission characteristics.

  • PDF

Intonational Pattern Frequency of Seoul Korean and Its Implication to Word Segmentation

  • Kim, Sa-Hyang
    • Speech Sciences
    • /
    • v.15 no.2
    • /
    • pp.21-30
    • /
    • 2008
  • The current study investigated distributional properties of the Korean Accentual Phrase and their implication to word segmentation. The properties examined were the frequency of various AP tonal patterns, the types of tonal patterns that are imposed upon content words, and the average number and temporal location of content words within the AP. A total of 414 sentences from the Read speech corpus and the Radio corpus were used for the data analysis. The results showed that the 84% of the APs contained one content word, and that almost 90% of the content words are located in AP-initial position. When the AP-initial onset was not an aspirated or tense consonant, the most common AP patterns were LH, LHH, and LHLH (78%), and 88% of the multisyllabic content words start with a rising tone in AP-initial position. When the AP-initial onset was an aspirated or tense consonant, the most common AP patterns were HH, HHLH, and HHL (72%), and 74% of the multisyllabic content words start with a level H tone in AP-initial position. The data further showed that 84.1% of APs end with the final H tone. The findings provide valuable information about the prosodic pattern and structure of Korean APs, and account for the results of a previous study which showed that Korean listeners are sensitive to AP-initial rising and AP-final high tones (Kim, 2007). This is in line with other cross-linguistic research which has revealed the correlation between prosodic probability and speech processing strategy.

  • PDF

Behaviour of transmission line conductors under tornado wind

  • Hamada, Ahmed;El Damatty, Ashraf A.
    • Wind and Structures
    • /
    • v.22 no.3
    • /
    • pp.369-391
    • /
    • 2016
  • Electricity is transmitted by transmission lines from the source of production to the distribution system and then to the end users. Failure of a transmission line can lead to devastating economic losses and to negative social consequences resulting from the interruption of electricity. A comprehensive in-house numerical model that combines the data of computational fluid dynamic simulations of tornado wind fields with three dimensional nonlinear structural analysis modelling of the transmission lines (conductors and ground-wire) is used in the current study. Many codes of practice recommend neglecting the tornado forces acting on the conductors and ground-wires because of the complexity in predicting the conductors' response to such loads. As such, real transmission line systems are numerically simulated and then analyzed with and without the inclusion of the lines to assess the effect of tornado loads acting on conductors on the overall response of transmission towers. In addition, the behaviour of the conductors under the most critical tornado configuration is described. The sensitivity of the lines' behaviour to the magnitude of tornado loading, the level of initial sag, the insulator's length, and lines self-weight is investigated. Based on the current study results, a recommendation is made to consider conductors and ground-wires in the analysis and design of transmission towers under the effect of tornado wind loads.

A Study on Degradation Pattern of GIS Using Clustering Methode (군집화 기법을 이용한 GIS 열화 패턴 연구)

  • Lee, Deok Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.4
    • /
    • pp.255-260
    • /
    • 2018
  • In recent years, increasing electricity use has led to considerable interest in green energy. In order to effectively supply, cut off, and operate an electric power system, many electric power facilities such as gas insulation switch (GIS), cable, and large substation facilities with higher densities are being developed to meet demand. However, because of the increased use of aging electric power facilities, safety problems are emerging. Electromagnetic wave and leakage current detection are mainly used as sensing methods to detect live-line partial discharges. Although electromagnetic sensors are excellent at providing an initial diagnosis and very reliable, it is difficult to precisely determine the fault point, while leakage current sensors require a connection to the ground line and are very vulnerable to line noise. The partial discharge characteristic in particular is accompanied by statistical irregularity, and it has been reported that proper statistical processing of data is very important. Therefore, in this paper, we present the results of analyzing ${\Phi}-q-n$ cluster distributions of partial discharge characteristics by using K-means clustering to develop an expert partial discharge diagnosis system generated in a GIS facility.

Optical Design of an Image-space Telecentric Two-mirror System for Wide-field Line Imaging

  • Lee, Jong-Ung;Kim, Youngsoo;Kim, Seo Hyun;Kim, Yeonsoo;Kim, Hyunsook
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.344-350
    • /
    • 2017
  • We present a new design approach and an example design for an image-space telecentric two-mirror system that has a fast f-number and a wide-field line image. The initial design of the telecentric mirror system is a conventional axially symmetric system, consisting of a flat primary mirror with fourth-order aspheric deformation and an oblate ellipsoidal secondary mirror to correct spherical aberration, coma, and field curvature. Even though in the optimized design the primary mirror is tilted, to avoid ray obstruction by the secondary mirror, the image-space telecentric two-mirror system shows quite good imaging performance, for a line imager.