• 제목/요약/키워드: initial burst

검색결과 119건 처리시간 0.022초

Somatodendritic organization of pacemaker activity in midbrain dopamine neurons

  • Jinyoung Jang;Shin Hye Kim;Ki Bum Um;Hyun Jin Kim;Myoung Kyu Park
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제28권2호
    • /
    • pp.165-181
    • /
    • 2024
  • The slow and regular pacemaking activity of midbrain dopamine (DA) neurons requires proper spatial organization of the excitable elements between the soma and dendritic compartments, but the somatodendritic organization is not clear. Here, we show that the dynamic interaction between the soma and multiple proximal dendritic compartments (PDCs) generates the slow pacemaking activity in DA neurons. In multipolar DA neurons, spontaneous action potentials (sAPs) consistently originate from the axon-bearing dendrite. However, when the axon initial segment was disabled, sAPs emerge randomly from various primary PDCs, indicating that multiple PDCs drive pacemaking. Ca2+ measurements and local stimulation/perturbation experiments suggest that the soma serves as a stably-oscillating inertial compartment, while multiple PDCs exhibit stochastic fluctuations and high excitability. Despite the stochastic and excitable nature of PDCs, their activities are balanced by the large centrally-connected inertial soma, resulting in the slow synchronized pacemaking rhythm. Furthermore, our electrophysiological experiments indicate that the soma and PDCs, with distinct characteristics, play different roles in glutamate-induced burst-pause firing patterns. Excitable PDCs mediate excitatory burst responses to glutamate, while the large inertial soma determines inhibitory pause responses to glutamate. Therefore, we could conclude that this somatodendritic organization serves as a common foundation for both pacemaker activity and evoked firing patterns in midbrain DA neurons.

집중치료실에서 치료한 중첩성 경련 환자의 신경생리학적 결과 분석 (The Analysis of Neuro-Physiological Outcome of Patients with Status Epilepticus in an Intensive Care Unit)

  • 김대식;김천식
    • 대한임상검사과학회지
    • /
    • 제37권2호
    • /
    • pp.96-101
    • /
    • 2005
  • Status epilepticus is a medical emergency, so that rapid and vigorous treatment is required to prevent neuronal damage and systemic complication. Status epilepticus is generally defined as a continuous or intermittent seizure or an unconscious condition after the onset of seizure, lasting for 30 minutes or more. We report here the outcome of status epilepticus. We retrospectively reviewed medical record of 15 patients who were diagnosed with status epilepticus at the Asan Medical Center from January 2003 to February 2004. This outcome was evaluated considering various factors such as age of patients, history of seizures, neurologic impairment, etiology, mortality, return to baseline and initial electroencephalogram (EEG) findings. The range of age was between 1 to 79 years old and the longest duration of treatment was 118 days. Most patients were treated by using pentobarbital, midazolam, phenobarbital and other antiepileptic drugs. The overall mortality was 5 (33%) out of 15 patients. The mortality was related to etiology, underlying other medical conditions and initial EEG findings. 5 (55%) out of the 9 patients with acute etiology, 5 (71%) out of the 7 patients with a multifocal or burst-suppression EEG activity, and 3 (60%) out of the 5 patients with other medical disease were related to mortality. This data demonstrate high mortality due to status epilepticus. Mortality is related to etiology, other medical conditions and abnormalities on the initial EEG.

  • PDF

하천유역의 유사량의 비교연구 (Comparison of Sediment Yield by IUSG and Tank Model in River Basin)

  • 이영화
    • 한국환경과학회지
    • /
    • 제18권1호
    • /
    • pp.1-7
    • /
    • 2009
  • In this study a sediment yield is compared by IUSG, IUSG with Kalman filter, tank model and tank model with Kalman filter separately. The IUSG is the distribution of sediment from an instantaneous burst of rainfall producing one unit of runoff. The IUSG, defined as a product of the sediment concentration distribution (SCD) and the instantaneous unit hydrograph (IUH), is known to depend on the characteristics of the effective rainfall. In the IUSG with Kalman filter, the state vector of the watershed sediment yield system is constituted by the IUSG. The initial values of the state vector are assumed as the average of the IUSG values and the initial sediment yield estimated from the average IUSG. A tank model consisting of three tanks was developed for prediction of sediment yield. The sediment yield of each tank was computed by multiplying the total sediment yield by the sediment yield coefficients; the yield was obtained by the product of the runoff of each tank and the sediment concentration in the tank. A tank model with Kalman filter is developed for prediction of sediment yield. The state vector of the system model represents the parameters of the tank model. The initial values of the state vector were estimated by trial and error.

Evaluation of In Vitro Release Profiles of Fentanyl-Loaded PLGA Oligomer Microspheres

  • Gilson Khang;Seo, Sun-Ah;Park, Hak-Soo;John M. Rhee;Lee, Hai-Bang
    • Macromolecular Research
    • /
    • 제10권5호
    • /
    • pp.246-252
    • /
    • 2002
  • In order to the development of the delivery device of long-acting local anesthetics for postoperative analgesia and control of chronic pain of cancer patient, fentnyl-loaded poly (L-lactide-co-glycolido) (PLGA, molecular weight, 5,000 g/mole; 50 : 50 mole ratio by lactide to glycolide) microspheres (FMS) were studied. FMS were prepared by an emulsion solvent-evaporation method. The influence of several preparation parameters such as initial drug loading, PLGA concentration, emulsifier concentration, oil phase volume, and fabrication temperature has been investigated on the fentanyl release profiles. Generally, the drug showed the biphasic release patterns, with an initial diffusion followed by a lag period before the onset of the degradation phase, but there was no lag time in our system. Fentanyl was slowly released from FMS over 10 days in vitro with a quasi-zero order property. The release rate increased with increasing drug loading as well as decreasing polymer concentration with relatively small initial burst effect. From the results, FMS may be a good formulation to deliver the anesthetic for the treatment of chronic pain.

Controlled Release of Gentamicin Sulfate from Poly(3-hydroxybu-tyrate-co-3-hydroxyvalerate) Wafers for the Treatment of Osteomyelitis

  • Gilson Khang;Park, Hak-Soo;John M. Rhee;Yoon, Sung-Chul;Cho, Jin-Cheol;Lee, Hai-Bang
    • Macromolecular Research
    • /
    • 제8권6호
    • /
    • pp.253-260
    • /
    • 2000
  • Biodegradable wafers were prepared with poly (hydroxybutyrate-co-hydroxyvalerate) (PHBV;5, 10, and 15 mole% for 3-hydroxyvalerate) by simple heat pressing method for the sustained release of antibiotic agent, gentamicin sulfate (GS) to investigate the possibility of the treatment for osteomyelitis. The effects of hydroxyvalerate (HV) content, thickness of wafers, various types of additives such as sodium dodecyl sulfate (SDS), microcrystalline cellulose, polyvinylpyrrolidone, and hydroxypropylcellulose (HPC), and different initial drug loading ratio on the release profile have been investigated. In vitro release studies showed that different release patterns and rates could be achieved by simply modifying factors in the preparation conditions. PHBV wafers with 3 mm thickness, 10% of GS initial loading, 15% of HV content and addition of 5% of SDS and HPC were free from initial burst and a near-zero-order sustained release was observed for over 30 days. It might be suggested that the mechanisms of G5 release may be more predominant simple dissolution and diffusion of GS than erosion of PHBV in our system.

  • PDF

약물지연방출을 위한 스테레오컴플렉스 PLA 원반형 마이크로입자 (Stereocomplex Poly(lactic acid) Discoidal Microparticles for Sustained Drug Release)

  • 박채원;박상효;김우철;기재홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권1호
    • /
    • pp.62-66
    • /
    • 2020
  • Controlled drug release is important for effective treatment of cancer. Poly(DL-lactide-co-glycolide) acid (PLGA) is a Food and Drug Administration (FDA) approved polymer and have been extensively studied as drug delivery carriers with biodegradable and biocompatible properties. However, PLGA drug delivery carriers are limited due to the initial burst release of drug. Certain drugs require an early rapid release, but in many cases the initial rapid release can be inefficient, reducing therapeutic effects and also increasing side effects. Therefore, sustained release is important for effective treatment. Poly Lactic Acid stereo complex (PLA SC) is resistant to hydrolysis and has high stability in aqueous solutions. Therefore, in this work, PLGA based discoidal polymeric particles are modified by Poly Lactic Acid stereocomplex (PLAsc DPPs). PLAsc DPPs are 3 ㎛ in diameter, also showing a relatively sustained release profile. Fluorescein 5(6)-isothiocyanate (FITC) released from PLAsc DPPs was continuously observed until 38 days, which showed the initial release of FITC from PLAsc DPPs was about 3.9-fold reduced as compared to PLGA based DPPs at 1 hour.

Preparation and Characterization of Poly(lactide-co-glycolide) Micro-spheres for the Sustained Release of AZT

  • Gilson Khang;Lee, Jin-Ho;Lee, Jin-Whan;Cho, Jin-Cheol;Lee, Hai-Bang
    • Macromolecular Research
    • /
    • 제8권2호
    • /
    • pp.80-88
    • /
    • 2000
  • Biodegradable microspheres were prepared with poly(L-lactide-co-glycolide) (PLGA, 75 : 25 by mole ratio) by an oil/oil solvent evaporation method for the sustained release of anti-AIDS virus agent, AZT The microspheres of relatively narrow size distribution (7.6$\pm$ 3.8 ㎛) were obtained by controlling the fabrication conditions. The shape of microspheres prepared was smooth and spherical. The efficiency of AZT loading into the PLGA microsphere was over 93% compared to that below 15% for microspheres by a conventional water/oil/water method. The effects of Preparation conditions on the morphology and in vitro AZT release pattern were investigated. in vitro release studies showed that different release pattern and release rates could be achieved by simply modifying factors in the fabrication conditions such as the type and amount of surfactant, initial amount of loaded drug, the temperature of solvent evaporation, and so on. PLCA microspheres prepared by 5% of initial drug loading, 1.0% (w/w) of surfactant concentration, and 25$\^{C}$ of solvent evaporation temperature were free from initial burst effect and a near-zero order sustained release was observed. Possible mechanisms of the near-zero order sustained release for our system have been proposed.

  • PDF

Perception of English Consonants in Different Prosodic Positions by Korean Learners of English

  • Jang, Mi
    • 말소리와 음성과학
    • /
    • 제6권1호
    • /
    • pp.11-19
    • /
    • 2014
  • The focus of this study was to investigate whether there is a position effect on identification accuracy of L2 consonants by Korean listeners and to examine how Korean listeners perceive the phonetic properties of initial and final consonants produced by a Korean learner of English and an English native speaker. Most studies examining L2 learners' perception of L2 sounds have focused on the segmental level but very few studies have examined the role of prosodic position in L2 learners' perception. In the present study, an identification test was conducted for English consonants /p, t, k, f, ɵ, s, ʃ/ in CVC prosodic structures. The results revealed that Korean listeners identified syllable-initial consonants more accurately than syllable-final consonants. The perceptual accuracy in syllable initial consonants may be attributable to the enhanced phonetic properties in the initial consonants. A significant correlation was found between error rates and F2 onset/offset for stops and fricatives, and between perceptual accuracy and RMS burst energy for stops. However, the identification error patterns were found to be different across consonant types and between the different language speakers. In the final position, Korean listeners had difficulty in identifying /p/, /f/, /ɵ/, and /s/ when they were produced by a Korean speaker and showed more errors in /p/, /t/, /f/, /ɵ/, and /s/ when they were spoken by an English native speaker. Comparing to the perception of English consonants spoken by a Korean speaker, greater error rates and diverse error patterns were found in the perception of consonants produced by an English native speaker. The present study provides the evidence that prosodic position plays a crucial role in the perception of L2 segments.

마약길항제의 방출 제어형 제제 (제2보): 나록손 이식제제의 생체적합성 및 약물속도론적 평가 (Controlled Release Dosage Form of Narcotic Antagonist(II) : Biocompatibility and Pharmacokinetics of Naloxone Implant)

  • 문미란;박주애;이승진;김형국;김길수
    • Journal of Pharmaceutical Investigation
    • /
    • 제25권2호
    • /
    • pp.117-123
    • /
    • 1995
  • For the effective administration of narcotic antagonist, the application of sustained release implantable systems with biodegradable polyphosphazene was examined. Using poly[(diethyl glutamate)-co-(ethyl glycinate) phosphazene], the implantable devices containing naloxone hydrochloride were prepared and in vivo implantation studies were carried out subcutaneously in rat and rabbit with this preparation for the biocompatibility and pharmacokinetics. The histological finding in rats at initial time period was the inflammation that occurred focally around the implants, but they were showed subsequent mild and limited chronic inflammations and the irreversible changes such as necrosis and degeneration of the muscle or connective tissues were not observed. Therefore the placebo and naloxone implants are considered to be biocompatible formulations histologically. In pharmacokinetic studies, the release of naloxone from the naloxone implants into blood plasma was maintained in 192 hours, but the initial burst effect was observed. If this problem was solved, the application for the narcotic antagonist sustained release systems can be expected.

  • PDF

MOW의 산소-알칼리 첨가 과산화수소 표백 (EoP Bleaching of Mixed Office Wastepaper)

  • 김승호;이형;백기현
    • 펄프종이기술
    • /
    • 제34권3호
    • /
    • pp.46-52
    • /
    • 2002
  • To produce the raw material used for printing and writing paper or high quality tissue, MOWs that were consisted of white ledger, colored ledger and old newspaper were bleached with EoP and EoPY(FAS) method, the EoP bleaching process gave the improvement in brightness and a high color removal efficiency. Especially, MOW B(initial brightness: 59.1% ISO) that contained much old newspaper showed the higher bleaching efficiency than those of MOW A(initial brightness: 68.3%). After EoPY(FAS) bleaching, MOW's brightness was increased from 68.3% ISO to 84.3∼84.0% ISO, and from 59.1% ISO to 78.7∼79.2% ISO, respectively. Also the tensile and burst index of bleached pulps decreased by 10∼30%. The tear index slightly decreased or halted at the same range as unbleached pulps.