• Title/Summary/Keyword: infrared reflective marker

Search Result 5, Processing Time 0.018 seconds

Evaluation of the Usefulness of the Self-developed Kw-infrared Reflective Marker in Non-coplanar Treatment (비동일면 치료 시 자체 제작한 Kw-infrared Reflective Marker의 유용성 평가)

  • Kwon, Dong-Yeol;Ahn, Jong-Ho;Park, Young-Hwan;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: In radiotherapy that takes into account respiration using a RPM (Real time Position Management, Varian, USA) system, which can treat in consideration of the movement of tumor, infrared reflective markers supplied by manufacturers cannot obtain respiratory signal if the couch rotates at a certain angle or larger. In order to solve this problem, the author developed the 3D infrared reflective marker named 'Kw-marker' that can obtain respiratory signal at any angle, and evaluate its usefulness. Materials and Methods: In order to measure the stability of respiratory signal, we put the infrared reflective marker on the 3D moving phantom that can reproduce respiratory movement and acquired respiratory signal for 3 minutes under each of 3 conditions (A: $couch\;0^{\circ}$, a manufacturer's infrared reflective marker B: $couch\;0^{\circ}$, Kw-marker C: $couch\;90^{\circ}$, Kw-marker). By analyzing the respiratory signal using a breath analysis program (Labview Ver. 7.0), we obtained the peak value, valley value, standard deviation, variation value, and amplitude value. In order to examine the rotation error and moving range of the target, we placed a B.B phantom on the 3D moving phantom, and obtained images at a couch angle of $0^{\circ}$ and $90^{\circ}$ using OBI, and then acquired the X, Y and Z values (mm) of the ball bearing at the center of the B.B phantom. Results: According to the results of analyzing the respiratory signal, the standard deviation at the peak value was A: 0.002, B: 0.002 and C: 0.003, and the stability of respiration for amplitude was A: 0.15%, B: 0.14% and C:0.13%, showing that we could get respiratory signal stably by using the Kw-marker. When the couch rotated $couch\;90^{\circ}$, the mean rotation error of the ball bearing, namely, the target was X: -1.25 mm, Y: -0.45 mm and Z: +0.1 mm, which were within 1.3 mm on the average in all directions, and the difference in the moving range of the target was within 0.3 mm. Conclusion: When we obtained respiratory signal using the Kw-marker in non-coplanar treatment where the couch rotated, we could acquire respiratory signal stably and the Kw-marker was effective enough to substitute for the manufacturer's infrared reflective marker. When the rotation error and moving range of the target were measured, there was little difference, indicating that the displacement of the reflector movement in couch rotation is the cause of change in the scale and amplitude of respiratory signal. If the converted value of amplitude height according to couch angle is studied further and applied, it may be possible to perform non-coplanar phase-based gating treatment.

  • PDF

Evaluation of Suitability of Retroreflective Material Locations by Motion Analysis of the Wearer of Safety Clothing (안전의복 착용자의 동작분석에 의한 재귀반사 소재 위치의 적합성 평가)

  • Soon Ja Park;Satoko Tanabe;Mariko Sato
    • Human Ecology Research
    • /
    • v.61 no.3
    • /
    • pp.493-503
    • /
    • 2023
  • Since ISO 20471 regulations(2013) were enacted, high-visibility clothing made of fluorescent fabric and retroreflective materials has been standardized to distinguish the wearers from the surrounding background in a dark place and to protect them. Accordingly, we made high-visibility safety clothing based on the international standards, and examined the positions of the retro-reflective materials on the attached sites to evaluate the suitability of the positions, by 3 types of safety clothing and the body regions when the wearers work or move. Two retro-reflective films of 5cm-horizontal lines were attached to the front/back of the upper-wear, and the lower-wear. Vertical lines were attached from the shoulder to the horizontal waistline. To analyze the motion in 3-dimension, we took pictured infrared-reflective markers on the retro-reflective film covered with yellow-tape on the front-side when 6 subjects wearing experimental garments performed 6 types of motions. According to the metronome tempo, the motions were performed for 30 seconds and repeated 6 motions ①~⑥ by 3 experimental clothing. Among the 6 motions, significant differences in the appearance rate of the markers by body region during the motions were found in 5 types except for motion ③. Significant differences by the post-hoc test were shown in motions ④ and ⑥ as well. Therefore, for high-visibility safety clothing, it is necessary to anticipate the worker's motion and consider the attaching position of the retro-reflective material. It is considered desirable to attach the retro-reflective materials to several places where the clothing is hard to wrinkle.

The Effects of Trunk Movement and Ground Reaction Force during Sit to Stand Using Visual Feedback (시각 되먹임을 이용한 앉은 자세에서 일어서기 시 몸통의 동작과 지면 반발력에 미치는 영향)

  • Yeong-Geon Koh;Tae-Young Oh;Jae-Ho Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.2
    • /
    • pp.207-219
    • /
    • 2023
  • Purpose : This study was conducted to investigate the changes in trunk movement and ground reaction during sit to stand motion using visual feedback. Methods : Fifteen adults (average age: 23.53±1.77 years) participated in this study. An infrared reflective marker was attached to the body each participant for motion analysis, and the participants performed sit to stand motion while wearing a hat attached with a laser pointer, which provided visual feedback. First, the sit to stand action was repeated thrice without obtaining any visual feedback, followed by a three minute break. Next, the laser pointers attached to hats were irradiated on a whiteboard, located at a distance of 5 m in front of the chairs, on which the participants sat; a baseline was set, and the participants performed stand up movements three times under this condition. A visual feedback was provided to the participants to prevent the laser pointers from crossing the set baseline. During each stand-up movement, the position of the reflective marker attached to the subject's body was recorded in real time using an infrared camera for motion analysis. The trunk movement and ground reaction force were extracted through recorded data and analyzed according to the presence or absence of visual feedback. Results : The results indicated that in the presence of a visual feedback during the sit-to-stand movements, the range of motion of the trunk and hip joints decreased, whereas that of the knee and ankle joints increased in the sagittal plane. The rotation angle of the trunk in the horizontal plane decreased. The left and right movement speed of the center of pressure increased, the pressing force decreased, and the forward and backward movement speed of the trunk decreased. Conclusion : The results suggest that the efficiency and stability of the stand up movement of a body increase when a visual feedback is provided.

Relationship between Center of Pressure and Local Stability of the Lower Joints during Walking in the Elderly Women

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.2
    • /
    • pp.133-140
    • /
    • 2017
  • Objective: The purpose of this study was to determine the relationship between center of pressure (CoP) and local stability of the lower joints, which was calculated based on approximate entropy (ApEn) during walking in elderly women. Method: Eighteen elderly women were recruited (age: $66.4{\pm}1.2yrs$; mass: $55.4{\pm}8.3kg$; height: $1.56{\pm}0.04m$) for this study. Before collecting data, reflective marker triads composed of 3 non-collinear spheres were attached to the lateral surface of the thigh and shank near the mid-segment to measure motion of the thigh and shank segments. To measure foot motion, reflective markers were placed on the shoe at the heel, head of the fifth metatarsal, and lateral malleolus, and were also placed on the right anterior-superior iliac spine, left anterior-superior iliac spine, and sacrum to observe pelvic motion. During treadmill walking, kinematic data were recorded using 6 infrared cameras (Oqus 300, Qualisys, Sweden) with a 100 Hz sampling frequency and kinetic data were collected from a treadmill (Instrumented Treadmill, Bertec, USA) for 20 strides. From kinematic data, 3D angles of the lower extremity's joint were calculated using Cardan technique and then ApEn were computed for their angles to evaluate local stability. Range of CoP was determined from the kinetic data. Pearson product-moment and Spearman rank correlation coefficient were applied to find relationship between CoP and ApEn. The level of significance was determined at p<.05. Results: There was a negative linear correlation between CoP and ApEn of hip joint adduction-abduction motion (p<.05), but ApEn of other joint motion did not affect the CoP. Conclusion: It was conjectured that ApEn, local stability index, for adduction/abduction of the hip joint during walking could be useful as a fall predictor.

Head Motion Detection and Alarm System during MRI scanning (MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템)

  • Pae, Chong-Won;Park, Hae-Jeong;Kim, Dae-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Purpose : During brain MRI scanning, subject's head motion can adversely affect MRI images. To minimize MR image distortion by head movement, we developed an optical tracking system to detect the 3-D movement of subjects. Materials and Methods: The system consisted of 2 CCD cameras, two infrared illuminators, reflective sphere-type markers, and frame grabber with desktop PC. Using calibration which is the procedure to calculate intrinsic/extrinsic parameters of each camera and triangulation, the system was desiged to detect 3-D coordinates of subject's head movement. We evaluated the accuracy of 3-D position of reflective markers on both test board and the real MRI scans. Results: The stereo system computed the 3-D position of markers accurately for the test board and for the subject with glasses with attached optical reflective marker, required to make regular head motion during MRI scanning. This head motion tracking didn't affect the resulting MR images even in the environment varying magnetic gradient and several RF pulses. Conclusion: This system has an advantage to detect subject's head motion in real-time. Using the developed system, MRI operator is able to determine whether he/she should stop or intervene in MRI acquisition to prevent more image distortions.