FTIR study of gamma and electron irradiated high-density polyethylene for high dose measurements

  • Al-Ghamdi, Hanan;Farah, Khaled;Almuqrin, Aljawharah;Hosni, Faouzi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.255-261
    • /
    • 2022
  • A reliable and well-characterized dosimetry system which is traceable to the international measurement system, is the key element to quality assurance in radiation processing with cobalt-60 gamma rays, X-rays, and electron beam. This is specifically the case for health-regulated processes, such as the radiation sterilization of single use medical devices and food irradiation for preservation and disinfestation. Polyethylene is considered to possess a lot of interesting dosimetric characteristics. In this work, a detailed study has been performed to determine the dosimetric characteristics of a commercialized high-density polyethylene (HDPE) film using Fourier transformed infrared spectrometry (FTIR). Correlations have been established between the absorbed dose and radiation induced infrared absorption in polyethylene having a maximum at 965 cm-1 (transvinylene band) and 1716 cm-1 (ketone-carbonyl band). We have found that polyethylene dose-response is linear with dose for both bands up to1000 kGy. For transvinylene band, the dose-response is more sensitive if irradiations are made in helium. While, for ketone-carbonyl band, the dose-response is more sensitive when irradiations are carried out in air. The dose-rate effect has been found to be negligible when polyethylene samples are irradiated with electron beam high dose rates. The irradiated polyethylene is relatively stable for several weeks after irradiation.

Stimulatory Effect of Ga-As Infrared Laser on the Regeneration of Injured Sciatic Nerves (손상된 좌골신경의 재생에 미치는 Ga-As 적외선 레이저의 효과)

  • 배춘식;임성철;박석천
    • Journal of Veterinary Clinics
    • /
    • v.19 no.3
    • /
    • pp.316-321
    • /
    • 2002
  • The purpose of this study was to examine the effect of Ga-As(Gallium-Arsenide, wave length; 904 nm) infrared laser irradiation on healing of the experimentally crush injured rat sciatic nerves. The bilateral sciatic nerves of 43 adult male Sprague-Dawley rats were compressed surgically with a straight hemostat (1 mm width). The right legs of all the rats were irradiated using a 27 mW Ga-As infrared laser (laser irradiated group). The radiation procedure was administered for 3 minutes every day for 1, 3, 5, and 7 weeks in each group. Left legs were not irradiated and served as the control group. The numbers of total myelinated axon and degenerated myelin in the sciatic nerves of bilateral legs were measured and analyzed with mage analysis system in order to make a morphological analysis of the effect of the Ga-As infrared laser on injured nerves. Total number of myelinated axons was increased with time interval, especially in the 1, 3. and 5 week of irradiated group. Conversely, the number of degenerated myelin was decreased with time interval, especially in the irradiated group. The effects in the irradiated group were more pronounced than those of the control group. In conclusion, the Ga-As infrared laser irradiation is a useful adjuvant therapy to the regeneration of the peripheral nerve injury.

Performance Evaluation of the Developed Diagnostic Multi-Leaf Collimator and Implementation of Fusion Image of X-ray Image and Infrared Thermography Image (개발한 진단용 다엽조리개 성능평가 및 X선영상과 적외선체열영상의 융합영상 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.365-371
    • /
    • 2019
  • We have developed and applied a diagnostic Multi-Leaf Collimator (MLC) to optimized the X-ray field in medical imaging and the usefulness evaluated through the fusion of infrared image and X-ray image acquired by infrared camera. The hand and skull radiography with multi-leaf collimator(MLC) showed significant area dose reductions of 22.9% and 31.3% compared to ARC and leakage dose was compliant with KS A 4732. Also scattering doses of 50 cm and 100 cm showed a significant decrease to confirm the usefulness of MLC. It was confirmed that the fusion of infrared images with an adjustable degree of transparency was possible in the X-ray images. Therefore, fusion of anatomical information with physiological convergence is expected to contribute and improvement of diagnostic ability. In addition, the feasibility of convergence X-ray imaging and DITI devices and the possibility of driving MLC with infrared images were confirmed.

Analysis on Characteristics of energy consumption an electric oven and far-infrared radiation oven (고천장 원적외선복사 전열시스템의 전기 및 열적 성능평가)

  • Kim, Yong-Ha;Jo, Hyun-Mi;Heo, Dong-Lyul;Kim, Ju-Hwan;Jo, A-Ra;Choe, Jang-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1274-1275
    • /
    • 2011
  • This paper study effects that measured hamony occurence and changes of current and voltage according to variation of temperature of Far Infrared Ray Radiant Oven's room affect power quality.

  • PDF

Experimental Evaluation of Far Infrared Characteristic for Bio Liquid Ceramics used in Bulding finishing Materials (액상세라믹의 원적외선 특성의 실험적평가)

  • 지철근;최태섭;장성일
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.7-12
    • /
    • 2002
  • This paper presents the Experimental Evaluation for the physical, chemical property and Far Infrared Characteristic, the effects to the living body of liquid ceramics which was made by the a Bio ceramic(co).

Comparison of the Effects of Luminous Lamp, and Nonluminous Lamp Radiation on Experimental Pain Threshold Sensitivity (발광·무광 적외선등 조사가 실험적 통증역치에 미치는 효과 비교)

  • Lim, In-Hyuk;Lee, Jeong-Weon;Cho, Su-Won
    • Physical Therapy Korea
    • /
    • v.9 no.3
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study was to compare the experimental pain threshold when used in luminous lamp radiation and nonluminous lamp radiation with healthy person. Thirty normal subjects were randomly assigned two groups: a luminous lamp radiation group, and a nonluminous lamp radiation group. The infrared lamps were applied on L3 for thirty minutes. Each group was measured for experimental pain threshold and local temperature before, 15 and 30 minute radiation. For statistical differences in change of the experimental pain threshold and local temperature due to differences in lamp ray was compared using the independent t-test. And, General linear model for profile plots test was used. The results were as: 1. Local temperature was significantly increased in the nonluminous lamp group (p<.01). 2. Experimental pain thershold was significantly increased in the luminous lamp group (p<.05),(p<.01). This study indicate that luminous lamp radiation was more effects of increase experimental pain thershold than nonluminous lamp radiation. Further study is needed to compare the effects of after period radiation.

  • PDF

The effect of postoperatively applied far-infrared radiation on pain and tendon-to-bone healing after arthroscopic rotator cuff repair: a clinical prospective randomized comparative study

  • Yoon, Ji Young;Park, Joo Hyun;Lee, Kwang Jin;Kim, Hyong Suk;Rhee, Sung-Min;Oh, Joo Han
    • The Korean Journal of Pain
    • /
    • v.33 no.4
    • /
    • pp.344-351
    • /
    • 2020
  • Background: The effects of far-infrared radiation (FIR) on the treatment of rotator cuff diseases remains unknown. We evaluated the safety and efficacy of FIR after arthroscopic rotator cuff repair with regard to postoperative pain and healing. Methods: This prospective randomized comparative study included 38 patients who underwent arthroscopic rotator cuff repair due to a medium-sized tear. Patients were randomly divided into the FIR or control group (n = 19 per group). In the FIR group, FIR with an FIR radiator started 1 week postoperatively for 30 minutes per session twice daily. It lasted until abduction brace weaning at 5 weeks postoperatively. We assessed pain using a pain visual analogue scale (pVAS) and measured the range of motion (ROM) of the shoulder at 5 weeks, and 3 and 6 months, postoperatively. The anatomical outcome was evaluated using magnetic resonance imaging at 6 months postoperatively. Results: At 5 weeks postoperatively, the average pVAS score was lower in the FIR group than in the control group (1.5 ± 0.8 vs. 2.7 ± 1.7; P = 0.019). At 3 months postoperatively, the average forward flexion was higher in the FIR group (151.6° ± 15.3° vs. 132.9° ± 27.8°; P = 0.045), but there was no significant difference at 6 months postoperatively. There was no significant difference in healing failure between the groups (P = 0.999). Conclusions: FIR after arthroscopic rotator cuff repair could be an effective and safe procedure to reduce postoperative pain, thereby facilitating rehabilitation and better ROM in the early postoperative period.

Protective effect of methanol extract from citrus press cakes prepared by far-infrared radiation drying on $H_2O_2$-mediated oxidative damage in Vero cells

  • Wijesinghe, W.A.J.P.;Senevirathne, Mahinda;Oh, Myung-Cheol;Jeon, You-Jin
    • Nutrition Research and Practice
    • /
    • v.5 no.5
    • /
    • pp.389-395
    • /
    • 2011
  • In the present study, a suitable drying method was developed for citrus press cakes (CPCs), which are produced as a by-product in citrus juice plants, and the protective effect of methanol extract of CPCs prepared by far-infrared radiation (FIR) drying against $H_2O_2$-induced DNA damage was evaluated versus that of freeze-dried CPCs. Methanol extract of FIR-dried CPCs exhibited comparatively good ROS scavenging activity versus the freeze-dried CPCs at the concentration of 100 ${\mu}g$/mL. The extract strongly enhanced the cell viability against $H_2O_2$-induced oxidative damage in Vero cells. Lipid peroxidation inhibitory activity of the extract from FIR-dried CPCs was comparable to that of the extract from freeze-dried CPCs. This sample also exhibited good protective effects against $H_2O_2$-mediated cell apoptosis as demonstrated by decreased apoptotic body formation in the nuclear staining with Hoechst 33342. In the comet assay, the CPC extracts exhibited strong inhibitory effects against $H_2O_2$-mediated DNA damage in a dose-dependent manner. Thus, this study demonstrated that FIR drying effectively preserves CPC as a functionally important natural antioxidant source and the FIR drying can be adapted for drying CPCs and is more economical for massive production than freeze drying.

Fabrication of Silicon Window for Low-price Thermal Imaging System (저가형 열영상 시스템을 위한 실리콘 윈도우 제작)

  • Sung, Byung Mok;Jung, Dong Geon;Bang, Soon Jae;Baek, Sun Min;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.264-269
    • /
    • 2015
  • An infrared (IR) bolometer measures the change of resistance by absorbing incident IR radiation and generates a signal as a function of the radiation intensity. Since a bolometer requires temperature stabilization and light filtering except for the infrared rays, it is essential for the device to be packaged meeting conditions that above mentioned. Minimization of heat loss is needed in order to stabilize temperature of bolometer. Heat loss by conduction or convection requires a medium, so the heat loss will be minimized if the medium is a vacuum. Therefore, vacuum packaging for bolometer is necessary. Another important element in bolometer packaging is germanium (Ge) window, which transmits IR radiation to heat the bolometer. To ensure a complete transmittance of IR light, anti-reflection (AR) coatings are deposited on both sides of the window. Although the transmittance of Ge window is high for IR rays, it is difficult to use frequently in low-price IR bolometer because of its high price. In this paper, we fabricated IR window by utilizing silicon (Si) substrate instead of Ge in order to reduce the cost of bolometer packaging. To enhance the IR transmittance through Si substrate, it is textured using Reactive Ion Etching (RIE). The texturing process of Si substrate is performed along with the change of experimental conditions such as gas ratio, pressure, etching time and RF power.

Antibacterial effect of citrus press-cakes dried by high speed and far-infrared radiation drying methods

  • Samarakoon, Kalpa;Senevirathne, Mahinda;Lee, Won-Woo;Kim, Young-Tae;Kim, Jae-Il;Oh, Myung-Cheol;Jeon, You-Jin
    • Nutrition Research and Practice
    • /
    • v.6 no.3
    • /
    • pp.187-194
    • /
    • 2012
  • In this study, the antibacterial effect was evaluated to determine the benefits of high speed drying (HSD) and far-infrared radiation drying (FIR) compared to the freeze drying (FD) method. Citrus press-cakes (CPCs) are released as a by-product in the citrus processing industry. Previous studies have shown that the HSD and FIR drying methods are much more economical for drying time and mass drying than those of FD, even though FD is the most qualified drying method. The disk diffusion assay was conducted, and the minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) were determined with methanol extracts of the dried CPCs against 11 fish and five food-related pathogenic bacteria. The disk diffusion results indicated that the CPCs dried by HSD, FIR, and FD prevented growth of all tested bacteria almost identically. The MIC and MBC results showed a range from 0.5-8.0 mg/mL and 1.0-16.0 mg/mL respectively. Scanning electron microscopy indicated that the extracts changed the morphology of the bacteria cell wall, leading to destruction. These results suggest that CPCs dried by HSD and FIR showed strong antibacterial activity against pathogenic bacteria and are more useful drying methods than that of the classic FD method in CPCs utilization.