• Title/Summary/Keyword: inflow concentration

Search Result 373, Processing Time 0.022 seconds

Performance Prediction of SCR-DeNOx System for Reduction of Diesel Engine NOx Emission (디젤엔진의 NOx 저감을 위한 SCR-DeNOx 후처리 시스템 성능 예측)

  • 김만영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.71-76
    • /
    • 2003
  • A numerical simulation of selective catalytic reduction (SCR) for NO with $NH_3$ is conducted over the $V_2O_5/TiO_2$ and $WO_3-V_2O_5/TiO_2$ catalysts. The governing $NH_3$ and NO transport equations are considered by using the time-dependent FCT (Flux-Corrected Transport) algorithm. After a validating simulation for $NH_3$ step feed and shut-off experiments is analyzed, transient behavior of $NH_3$ and NO concentration in a SCR catalyst is investigated by changing such parameters as inflow $NH_3$ concentration, temperature of the catalyst, and $NH_3$/NOx ratios.

Water Pollution Status in Streams of Hongsung Area (홍성 지역 하천수의 수질현황)

  • 홍영호;조석형;전용진
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2001
  • The purpose of this study on environmental investigation in Hongsung and Kwangchun streams is for the finding the degree of water quality. Physicochemical characteristics of streams are very important. However, that has not been investigated so for especially in stream of Hongsung area, And so, we tried to analyse BOD, TDS, $Cl^{-}$, anionic surfactant, pH, T-N and T-P of stream. The results were as follows. The pH for stream were generally in the range of 6.9 ~ 8.1 which is water quality for stander for stream, water quality of the Hongsung and Kwangchun upstream was not in problem but downstream showed somewhat high concentration in BOD, chlorine ion, T-P, T-N, and anionic surfactants. Especially BOD of Kwangchun downstream was higher than Hongsung downstream and concentration of T-P of Hongsung downstream was kept over 7 mg/liter regardless of inflow BOD ranging from 1.3 to 1.8 mg/liter.

  • PDF

Performance Evaluation of Window Ventilation System for Reducing Indoor particulate matter (실내 미세먼지 저감을 위한 창호형 환기시스템 성능평가)

  • Yang, Young Kwon;Park, Jin Chul
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.1-7
    • /
    • 2019
  • Indoor particulate matter(PM) is a carcinogen and needs to be removed and managed. It is generally reduced and removed through ventilation and filtration. Owing to the recent occurrence of high-concentration fine dust and yellow dust in the atmosphere, however, it is difficult to expect the purification of indoor air through the simple introduction of the outside air. For residential buildings, in particular, they are highly dependent on natural ventilation but the lack of natural ventilation is worsening because concerns over the inflow of external pollutants are increasing. Therefore, this study designed and manufactured a window ventilation system that does not require a duct to improve the maintenance and management problems of general ventilation system, and constructed indoor PM concentration change data through performance evaluation.

Enhanced total phosphorus removal using a novel membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation (유입흐름 변경 및 전응집 기반 이단응집 제어 적용 MBR을 통한 총인처리 개선 연구)

  • Cha, Jaehwan;Shin, Kyung-Suk;Park, Seung-Kook;Shin, Jung-Hun;Kim, Byung-Goon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.103-114
    • /
    • 2017
  • A membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation was evaluated in terms of phosphorus removal efficiency and cost-savings. The MBR consisted of two identical alternative reaction tanks, followed by aerobic, anoxic and membrane tanks, where the wastewater and the internal return sludge alternatively flowed into each alternative reaction tank at every 2 hours. In the batch-operated alternative reaction tank, the initial concentration of nitrate rapidly decreased from 2.3 to 0.4 mg/L for only 20 minutes after stopping the inflow, followed by substantial release of phosphorus up to 4 mg/L under anaerobic condition. Jar test showed that the minimum alum doses to reduce the initial $PO_4$-P below 0.2 mg/L were 2 and 9 mol-Al/mol-P in the wastewater and the activated sludge from the membrane tank, respectively. It implies that a pre-coagulation in influent is more cost-efficient for phosphorus removal than the coagulation in the bioreactor. On the result of NUR test, there were little difference in terms of denitrification rate and contents of readily biodegradable COD between raw wastewater and pre-coagulated wastewater. When adding alum into the aerobic tank, alum doses above 26 mg/L as $Al_2O_3$ caused inhibitory effects on ammonia oxidation. Using the two-stage coagulation control based on pre-coagulation, the P concentration in the MBR effluent was kept below 0.2 mg/L with the alum of 2.7 mg/L as $Al_2O_3$, which was much lower than 5.1~7.4 mg/L as $Al_2O_3$ required for typical wastewater treatment plants. During the long-term operation of MBR, there was no change of the TMP increase rate before and after alum addition.

Uncertainty of Discharge-SS Relationship Used for Turbid Flow Modeling (탁수모델링에 사용하는 유량-SS 관계의 불확실성)

  • Chung, Se-Woong;Lee, Jung-Hyun;Lee, Heung-Soo;Maeng, Seung-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.12
    • /
    • pp.991-1000
    • /
    • 2011
  • The relationship between discharge (Q) and suspended sediment (SS) concentration often is used for the estimation of inflow SS concentration in reservoir turbidity modeling in the absence of actual measurements. The power function, SS=aQb, is the most commonly used empirical relation to determine the SS load assuming the SS flux is controlled by variations of discharge. However, Q-SS relation typically is site specific and can vary depending on the season of the year. In addition, the relation sometimes shows hysteresis during rising limb and falling limb for an event hydrograph. The objective of this study was to examine the hysteresis of Q-SS relationships through continuous field measurements during flood events at inflow rivers of Yongdam Reservoir and Soyang Reservoir, and to analyze its effect on the bias of SS load estimation. The results confirmed that Q-SS relations display a high degree of scatter and clock-wise hysteresis during flood events, and higher SS concentrations were observed during rising limb than falling limb at the same discharge. The hysteresis caused significant bias and underestimation of SS loading to the reservoirs when the power function is used, which is important consideration in turbidity modeling for the reservoirs. As an alternative of Q-SS relation, turbidity-SS relation is suggested. The turbidity-SS relations showed less variations and dramatically reduced the bias with observed SS loading. Therefore, a real-time monitoring of inflow turbidity is necessary to better estimate of SS influx to the reservoirs and enhance the reliability of reservoir turbidity modeling.

Real-time Monitoring of Temperature and Relative Humidity and Visualization of Pest Survey Data for Integrated Pest Management in Collection Storage Area (유물 공간의 종합적 유해생물 관리(Integrated Pest Management)를 위한 실시간(Real-Time) 온습도 모니터링 및 유해 생물 조사 자료의 시각화)

  • Im, Ik-Gyun;Lim, Seong-Duk;Han, Gyu-Seong
    • Journal of Conservation Science
    • /
    • v.37 no.5
    • /
    • pp.440-450
    • /
    • 2021
  • Temperature and humidity data collection using real-time sensors and data loggers was conducted for integrated pest management in the collection storage and exhibition space of the Jeongnimsaji Museum, Buyeo. The real-time temperature and humidity monitoring system collected measurement data every 30 minutes and enabled real-time confirmation of the data through a linked application. If the temperature and humidity data measured in the real-time temperature and humidity monitoring system exceeds the set range, a push notification was sent to the mobile phone of the person in charge to provide status information to establish a continuous management system. Through this, it was possible to immediately recognize and take action when the temperature range exceeded the recommended relic temperature in August. We performed data visualization on the concentration of airborne fungus in the storage area and the inflow path and density of insects. Based on the recommended criteria presented by the National Institute of Cultural Heritage, The data on the spatial and temporal concentration of airborne fungus inside the collection storage were found to be maintained at a value below the standard recommended by the National Institute of Cultural Heritage (80 CFU/m3). Also, as a result of the insect inflow survey, no insects were captured inside the storage area, and in the case of the exhibition space, insects such as Scutigera coleoptrata, Loxoblemmus arietulus, Diestrammena asynamora, Koreoniscus racovitzai were captured. Based on this, as a result of visualization according to the individual density of captured insects by area, it was confirmed that the main inflow paths of insects were the external entrance and the toilet area.

Effect of ammonia nitrogen and microorganisms on the elevated nitrogenous biochemical oxygen demand (NBOD) levels in the Yeongsan river in Gwangju (광주지역 영산강의 NBOD 발생에 대한 암모니아성 질소 및 미생물 영향 연구)

  • Jang, Dong;Cho, Gwangwoon;Son, Gyeongrok;Kim, Haram;Kang, Yumi;Lee, Seunggi;Hwang, Soonhong;Bae, Seokjin;Kim, Yunhee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.2
    • /
    • pp.81-95
    • /
    • 2022
  • The present study was performed to investigate the effects of NH3-N and nitrifying microorganisms on the increased BOD of downstream of the Yeongsan river in Gwangju. Water samples were collected periodically from the 13 sampling sites of rivers from April to October 2021 to monitor water qualities. In addition, the trends of nitrogenous biochemical oxygen demand (NBOD) and microbial clusters were analyzed by adding different NH3-N concentrations to the water samples. The monitoring results showed that NH3-N concentration in the Yeongsan river was 22 times increased after the inflow of discharged water from the Gwangju 1st public sewage treatment plant (G-1-PSTP). Increased NH3-N elevated NBOD levels through the nitrification process in the river, consequently, it would attribute to the increase of BOD in the Yeongsan river. Meanwhile, there was no proportional relation between NBOD and NH3-N concentrations. However, there was a significant difference in NBOD occurrence by sampling sites. Specifically, when 5 mg/L NH3-N was added, NBOD of the river sample showed 2-4 times higher values after the inflow of discharged water from G-1-PSTP. Therefore, it could be thought other factors such as microorganisms influence the elevated NBOD levels. Through next-generation sequencing analysis, nitrifying microorganisms such as Nitrosomonas, Nitroga, and Nitrospira (Genus) were detected in rivers samples, especially, the proportion of them was the highest in river samples after the inflow of discharged water from G-1-PSTP. These results indicated the effects of nitrifying microorganisms and NH3-N concentrations as important limiting factors on the increased NBOD levels in the rivers. Taken together, comprehensive strategies are needed not only to reduce the NH3-N concentration of discharged water but also to control discharged nitrifying microorganisms to effectively reduce the NBOD levels in the downstream of the Yeongsan river where discharged water from G-1-PSTP flows.

A Study on the Pressure drop Variance of Pulse interval, injection distance in Pulse Air Jet Type Bag Filter (충격기류식 여과집진장치의 펄스간격 밀 분사거리에 따른 압력손실변화에 관한 기초 연구)

  • Seo, Jeong Min;Choe, Geum Chan;Park, Jeong Ho
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.223-232
    • /
    • 2004
  • The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to $50mmH_2O$ varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/㎥ and 1g/㎥, the pressure $drop(\DeltaP)$ was stable 60 to 90minutes after operation. For the higher concentration of 3g/㎥, as $\DeltaP$ continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 1l0mm, when inlet dust concentration is 0.5g/㎥ or 1g/㎥, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/㎥ and 3g/㎥ has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.

Temporal and Spatial Characteristics of Water Quality in a River-Reservoir (Paldang) (하천형 호수인 팔당호 수질의 시공간적 특성)

  • Kong, Dongsoo;Min, Jeong-Ki;Byeon, Myeongseop;Park, Hae Kyung;Cheon, Se-Uk
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.5
    • /
    • pp.470-486
    • /
    • 2018
  • This study is to investigate the allochthonous load and water quality of a typical river-reservoir, Paldang during spring (March ~ May) of 17 years (2001 ~ 2017). Phosphorus loading from point sources seems to have been reduced by 74 % in the 2010s. As a result, trophic state of the Paldang reservoir, eutrophic during the 2000s, has returned to the lmesotrophic state. Along with decrease in phosphorus concentration, standing crops of algae (Chl.a) decreased, and concentration of biodegradable organic material decreased to the past level. Concentration of total suspended solids has decreased, and it is due to the decrease of phytoplankton standing crops since the mid-2000s. As transparency increased, it is estimated that euphotic area increased by 22 % and euphotic capacity expanded by 27 %. In the river/transition zone of Paldang, concentration of organic matter increases slightly due to algal growth, but concentration of all water quality items decreases in the lacustrine zone. Although algal growth rate revealed positive correlation with concentration of phosphorus, it was insignificant. Algal growth appeared to be dependent on renewal of phosphorus by flow, than either flow rate or phosphorus concentration. The empirical model including inflow phytoplankton concentration fit well with observed values, and indicates the Paldang reservoir is greatly influenced by allochthonous loads.

A Study on the Calculation of Storage Volume of Storm-Water Detention Basins for Small Urban Catchments (도심지 소유역에 적용 가능한 우수저류조의 용량 산정에 관한 연구)

  • Kim, Dae Geun;Koh, Young Chan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.619-624
    • /
    • 2005
  • This work is for examining a simplified equation based on the rational formula, which can easily decide storm-water detention volume in small urban catchments. The storm-water detention volume is determined by the inflow hydrograph flowing to detention basin and the outflow hydrograph discharged from the detention basin. The ratio of average outflow over the period of rainfall duration against allowable discharge was 0.5 in former simplified equation. But this research has found that the average outflow ratio depends on the storage methodology. In the case of the on-line storage method, the average outflow ratio is a function of the time of concentration of the catchments and rainfall duration, which ranged from 0.5~1.0. In the case of the off-line storage method, the average ratio is a function of peak discharge and allowable discharge except above time of concentration and rainfall duration, where its function value ranged from 1.0~2.0. When applying this equation to small catchment in Mokpo city, South Korea, we could easily calculate the relation curve between the storm-water detention volume and allowable discharge.