• 제목/요약/키워드: infiltration and exfiltration

검색결과 6건 처리시간 0.016초

하수관거 정비지역의 관거이송 유량 및 수질특성 변화 (Changes in Characteristics of Sewer Flow & Its Water Quality from the Sewer Rehabilitation Area)

  • 박준대;오승영;최윤호;김용석
    • 한국물환경학회지
    • /
    • 제31권2호
    • /
    • pp.196-208
    • /
    • 2015
  • This study analyzed the characteristics of sewer flow and its water quality, and investigated changes in the characteristics in three areas where the sewer rehabilitation projects have been carried out. In S1 area, the patterns of the flow became regular and the range of the fluctuation decreased after the sewer rehabilitation. The flow and its BOD concentration increased. The infiltration/inflow and exfiltration showed clear distinction before and after the sewer rehabilitation in this area. In S2 area, the patterns and the range of the fluctuation of the flow made no differences before and after the sewer rehabilitation. The flow decreased slightly and its BOD concentration increased considerably after the sewer rehabilitation. Big decrement in stormwater inflow but small in exfiltration appeared in this area. In S3 area, the patterns and the range of the fluctuation of the flow made no differences before and after the sewer rehabilitation. The flow decreased slightly and its BOD concentration increased in a small rate in this area.

냉동냉장창고 침기방지장치의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Infiltration Prevent Devices in refrigerated Warehouse)

  • 곽현철;석호태;송승영;황혜주;안홍섭
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.55-62
    • /
    • 2002
  • In this paper, several types of infiltration prevention devices that are currently in use have been studied through experimental investigation. Firstly, the types of infiltration prevention devices were defined through investigating actual conditions of refrigerated warehouse in operates. Based on this investigation results, measured change of temperature and figured out air change rates of the type of infiltration prevention devices by using scale down model. After that, found the amount of air change rate in order to estimate the load of air change easily in facility plan.

하수관거보수 순위결정을 위한 침입수/유입수량에 대한 정량/정성 분석의 실행 연구 (A Quantitative/Qualitative Study of Infiltration/Inflow for Order Decision of Sewer pipe Maintenance)

  • 박명균;김대성;안원식;오정미
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.53-62
    • /
    • 2006
  • This study was carried out to obtain quantities of infiltration, inflow and exfiltration on sewer pipes of three areas at a small city. From the results, the most investigated sewer pipes should be infiltrated by underground water and undetermined water. Flowrate commonly showed two peak at 6 to 8 a.m. and 6 to 9 p.m. and which may be influenced by the sewer flowrate with washing or bathing time. BOD/TN ratio of below 4.0 were inferior as compared with proper criteria 5.1. Infiltration/inflow rates of three areas were 21.7% and $0.08m^3/km$ of A, 12.4% and $0.015m^3/km$ of B, 22.4% and $0.021m^3/km$ of C, respectively. This indicates that infiltration/inflow rate of A was obviously greater than that of B and C. Also, these results show that we can conduct sewer maintenance in good order as A, C and B zone.

침투 트렌치로 인한 유출 양상의 실험 연구 (Experimental Study of Runoff Induced by Infiltration Trench)

  • 이상호;조희호;이정민;박재현
    • 한국물환경학회지
    • /
    • 제24권1호
    • /
    • pp.107-117
    • /
    • 2008
  • Infiltration facilities are effective instruments to mitigate flood and can increase base runoff in urban watersheds. In order to analyze effects of infiltration trenches physical model experiments were conducted. The physical model facility consists of two soil tanks, artificial rainfall generators, tensiometers, and piezometers. The experiment was conducted by nine times and each case differed in rainfall intensity, rainfall duration and the type of ground surface. Measured quantities in the experiments are as follows: surface runoff, subsurface runoff, trench pipe runoff, groundwater level, water content, etc. The following resulted from the model experiment: The volume of subsurface runoff at trench watershed was maximum 78.3% compared with rainfall. This value is bigger than that of ordinary rate of subsurface runoff, and shows a groundwater recharge effect of trench. The time of runoff passing through the trench became earlier and the volume of runoff became larger with the increase of inflow into the trench, while trench exfiltration into ground became relatively smaller. The results of this study presented above show that infiltration trenches are effective instruments to increase base runoff during dry periods.

복잡한 지형에 있어서 디지털 지형모델을 이용한 유출량 계산 (Accumulation of Streamflow in Complex Topography by Digital Terrain Models)

  • 전무갑
    • 한국농공학회지
    • /
    • 제38권5호
    • /
    • pp.47-54
    • /
    • 1996
  • 본 연구에서는 지표면유출과 중간유출의 수문학적과정을 함께 모의발생 시키는 합성 유역모델이 제시되었다. 본 모델은 디지털지형모델과 상호 연결되도록 하였으며 지형이 복잡한 지역에서도 유출이 시간과 공간적으로 누가계산되어 이 분야의 조사연구에 필요한 정보를 제공할 수 있다. 본모델을 이용 유역의 불투수층 위에 분포해있는 토양의 중간계층과 토양수분의 계산 및 침투/용탈의 과정을 모의 발생시킬 수 있다.

  • PDF

공동주택의 지하주차장 연결통로 및 엘리베이터 홀의 환기에 관한 실험적 연구 (An Experimental Study on Ventilation of Connection Passage and Elevator Hall of Underground Parking in the Apartment Houses)

  • 김일겸;박우철
    • 한국산학기술학회논문지
    • /
    • 제9권6호
    • /
    • pp.1523-1528
    • /
    • 2008
  • 본 논문에서는 지하주차장 연결통로 및 엘리베이터 홀의 기계식 환기장치의 설치 및 적용을 위한 기초자료를 얻기 위하여 공동주택 지하주차장에 환기장치를 설치하여 실험을 수행하였다. 엘리베이터 홀의 경우 침기 및 누기(자연환기)로 인하여 실제 환기회수는 계산환기회수의 5배 정도 크게 나타났다. 지하 주차장 연결통로 및 엘리베이터홀의 환기장치는 동시 급 배기로 설치하는 것이 좋으며, 설치가 어려울 때에는 차선책으로 급기만이라도 설치하는 것이 공기질 측면에서 좋을 것이라 판단된다. 겨울철 환기장치 가동에 따른 콜드 드래프트의 영향을 고려하여 환기장치의 급기부에 예열기를 설치하는데, 환기시스템의 가동유무 및 가동방법을 다르게 하여도 지하주차장 연결통로 및 엘리베이터 홀의 온도가 $7{\sim}8^{\circ}C$로 일정하게 유지되어 나타나므로 한국의 남부지역에서는 단순 급 배기 환기장치에 예열기를 설치하지 않아도 될 것으로 판단된다.