• 제목/요약/키워드: inelastic earthquake response

검색결과 187건 처리시간 0.022초

층간변위를 기반으로 한 다층구조물의 내전성능 평가를 위한 역량스펙트럼법의 개발 (Capacity Spectrum Method for Seismic Performance Evaluation of Multi-Story Building Based on the Story Drift)

  • 김선필;김두기;곽효경;고성혁;서형열
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.205-210
    • /
    • 2007
  • The existing capacity spectrum method (CSM) is based on the displacement based approach for seismic performance and evaluation. Currently, in the domestic and overseas standard concerning seismic design, the CSM to obtain capacity spectrum from capacity curve and demand spectrum from elastic response spectrum is presented. In the multistory building, collapse is affected more by drift than by displacement, but the existing CSM does not work for story drift. Therefore, this paper proposes an improved CSM to estimate story drift of structures through seismic performance and evaluation. It uses the ductility factor in the A-T domain to obtain constant-ductility response spectrum from earthquake response of inelastic system using the drift and capacity curve from capacity analysis of structure.

  • PDF

기계학습 기반 강 구조물 지진응답 예측기법 (Machine Learning based Seismic Response Prediction Methods for Steel Frame Structures)

  • 이승혜;이재홍
    • 한국공간구조학회논문집
    • /
    • 제24권2호
    • /
    • pp.91-99
    • /
    • 2024
  • In this paper, machine learning models were applied to predict the seismic response of steel frame structures. Both geometric and material nonlinearities were considered in the structural analysis, and nonlinear inelastic dynamic analysis was performed. The ground acceleration response of the El Centro earthquake was applied to obtain the displacement of the top floor, which was used as the dataset for the machine learning methods. Learning was performed using two methods: Decision Tree and Random Forest, and their efficiency was demonstrated through application to 2-story and 6-story 3-D steel frame structure examples.

Evaluation of ground motion scaling methods on drift demands of energy-based plastic designed steel frames under near-fault pulse-type earthquakes

  • Ganjavi, Behnoud;Hadinejad, Amirali;Jafarieh, Amir Hossein
    • Steel and Composite Structures
    • /
    • 제32권1호
    • /
    • pp.91-110
    • /
    • 2019
  • In the present study, the effects of six different ground motion scaling methods on inelastic response of nonlinear steel moment frames (SMFs) are studied. The frames were designed using energy-based PBPD approach with the design concept using pre-selected target drift and yield mechanism as performance limit state. Two target spectrums are considered: maximum credible earthquake spectrum (MCE) and design response spectrum (DRS). In order to investigate the effects of ground motion scaling methods on the response of the structures, totally 3216 nonlinear models including three frames with 4, 8 and 16 stories are designed using PBPD approach and then they are subjected to ensembles of ground motions including 42 far-fault and 90 near-fault pulse-type records which were scaled using the six different scaling methods in accordance to the two aforementioned target spectrums. The distributions of maximum inter-story drift over the height of the structures are computed and compared. Finally, the efficiency and reliability of each ground motion scaling method to estimate the maximum nonlinear inter-story drift of special steel moment frames designed by energy-based PBPD approach are statistically investigated, and the most suitable scaling methods with the lowest dispersion for two groups of earthquake ground motions are introduced.

Transverse seismic response of continuous steel-concrete composite bridges exhibiting dual load path

  • Tubaldi, E.;Barbato, M.;Dall'Asta, A.
    • Earthquakes and Structures
    • /
    • 제1권1호
    • /
    • pp.21-41
    • /
    • 2010
  • Multi-span steel-concrete composite (SCC) bridges are very sensitive to earthquake loading. Extensive damage may occur not only in the substructures (piers), which are expected to yield, but also in the other components (e.g., deck, abutments) involved in carrying the seismic loads. Current seismic codes allow the design of regular bridges by means of linear elastic analysis based on inelastic design spectra. In bridges with superstructure transverse motion restrained at the abutments, a dual load path behavior is observed. The sequential yielding of the piers can lead to a substantial change in the stiffness distribution. Thus, force distributions and displacement demand can significantly differ from linear elastic analysis predictions. The objectives of this study are assessing the influence of piers-deck stiffness ratio and of soil-structure interaction effects on the seismic behavior of continuous SCC bridges with dual load path, and evaluating the suitability of linear elastic analysis in predicting the actual seismic behavior of these bridges. Parametric analysis results are presented and discussed for a common bridge typology. The response dependence on the parameters is studied by nonlinear multi-record incremental dynamic analysis (IDA). Comparisons are made with linear time history analysis results. The results presented suggest that simplified linear elastic analysis based on inelastic design spectra could produce very inaccurate estimates of the structural behavior of SCC bridges with dual load path.

A new approach for 3-D pushover based analysis of asymmetric buildings: development and initial evaluation

  • Baros, Dimitrios K.;Anagnostopoulos, Stavros A.
    • Earthquakes and Structures
    • /
    • 제12권5호
    • /
    • pp.543-557
    • /
    • 2017
  • Results of an extensive study aiming to properly extend the well known pushover analysis into 3-D problems of asymmetric buildings are presented in this paper. The proposed procedure uses simple, 3 DOF, one-story models with shear-beam type elements in order to quantify the effects of inelastic torsional response of such buildings. Correction coefficients for the response quantities at the "stiff" and "flexible" sides are calculated using results from non-linear time history analyses of the simple models. Their values are then applied to the results of a simple, plane pushover analysis of the detailed building models. Results from the application of the new method for a set of three, conventionally designed, five-story buildings with high values of uniaxial eccentricities are compared with those obtained from multiple non-linear dynamic time history analyses, as well as from similar pushover methods addressing the same problem. This initial evaluation indicates that the proposed procedure is a clear improvement over the simple (conventional) pushover method and, in most cases, more accurate and reliable than the other methods considered. The accuracy, however, of all these methods is reduced substantially when they are applied to torsionally flexible buildings. Thus, for such challenging problems, use of inelastic dynamic analyses for a set of two component earthquake motions appears to be the preferable solution.

Characterization and modeling of near-fault pulse-like strong ground motion via damage-based critical excitation method

  • Moustafa, Abbas;Takewaki, Izuru
    • Structural Engineering and Mechanics
    • /
    • 제34권6호
    • /
    • pp.755-778
    • /
    • 2010
  • Near-fault ground motion with directivity or fling effects is significantly influenced by the rupture mechanism and substantially different from ordinary records. This class of ground motion has large amplitude and long period, exhibits unusual response spectra shapes, possesses high PGV/PGA and PGD/PGA ratios and is best characterized in the velocity and the displacement time-histories. Such ground motion is also characterized by its energy being contained in a single or very few pulses, thus capable of causing severe damage to the structures. This paper investigates the characteristics of near-fault pulse-like ground motions and their implications on the structural responses using new proposed measures, such as, the effective frequency range, the energy rate (in time and frequency domains) and the damage indices. The paper develops also simple mathematical expressions for modeling this class of ground motion and the associated structural responses, thus eliminating numerical integration of the equations of motion. An optimization technique is also developed by using energy concepts and damage indices for modeling this class of ground motion for inelastic structures at sites having limited earthquake data.

강진 시 납-고무 면진장치의 비탄성 변위응답에 대한 온도상승 및 좌굴효과의 분석 (Evaluation of Heating and Buckling Effects on Inelastic Displacement Responses of Lead-Rubber Bearing Subject to Strong Ground Motions)

  • 윤수정;홍지영;문지호;송종걸
    • 한국지진공학회논문집
    • /
    • 제23권6호
    • /
    • pp.289-299
    • /
    • 2019
  • The tendency to use a probabilistic design method rather than a deterministic design method for the design of nuclear power plants (NPPs) will increase because their safety should be considered and strictly controlled in relation to various causes of damage. The distance between a seismically isolated NPP structure and a moat wall is called the clearance to stop. The clearance to stop is obtained from the 90th percentile displacement response of a seismically isolated NPP subject to a beyond design basis earthquake (BDBE) in the probabilistic design method. The purpose of this study is to analyze the effects of heating and buckling effects on the 90th percentile displacement response of a lead-rubber bearing (LRB) subject to a BDBE. The analysis results show that considering the heating and buckling effects to estimate the clearance to stop is conservative in the evaluation of the 90th percentile displacement response. If these two effects are not taken into account in the calculation of the clearance to stop, the underestimation of the clearance to stop causes unexpected damage because of an increase in the collision probability between the moat wall and the seismically isolated NPP.

지진격리된 원전배관의 지진취약도 분석 (Seismic Fragility Analysis of Base Isolated NPP Piping Systems)

  • 전법규;최형석;함대기;김남식
    • 한국지진공학회논문집
    • /
    • 제19권1호
    • /
    • pp.29-36
    • /
    • 2015
  • Base isolation is considered as a seismic protective system in the design of next generation Nuclear Power Plants (NPPs). If seismic isolation devices are installed in nuclear power plants then the safety under a seismic load of the power plant may be improved. However, with respect to some equipment, seismic risk may increase because displacement may become greater than before the installation of a seismic isolation device. Therefore, it is estimated to be necessary to select equipment in which the seismic risk increases due to an increase in the displacement by the installation of a seismic isolation device, and to perform research on the seismic performance of each piece of equipment. In this study, modified NRC-BNL benchmark models were used for seismic analysis. The numerical models include representations of isolation devices. In order to validate the numerical piping system model and to define the failure mode, a quasi-static loading test was conducted on the piping components before the analysis procedures. The fragility analysis was performed by using the results of the inelastic seismic response analysis. Inelastic seismic response analysis was carried out by using the shell finite element model of a piping system considering internal pressure. The implicit method was used for the direct integration time history analysis. In addition, the collapse load point was used for the failure mode for the fragility analysis.

비대칭 벽식구조의 최적 비틀림 설계 (An optimized torsional design of asymmetric wall structures)

  • 조봉호;홍성걸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.327-334
    • /
    • 2002
  • This paper develops an optimized torsional design method of asymmetric wall structures considering deformation capacities of walls. Contrary to the current torsional provisions, a deformation based torsional design is based on the assumption that stiffness and strength are dependent. Current torsional provisions specify two design eccentricity of stiffness to calculate the design forces of members. But such a methodology leads to an excessive over-strength of some members and an optimal torsional behavior is not ensured. Deformation-based torsional design uses displacement and rotation angle as design parameters and calculates base shear for inelastic torsional response directly. Because optimal torsional behavior can be defined based on the deformation of members, deformation based torsional design procedure can be applied to the optimal and performance-based torsional design. To consider the effect of accidental eccentricity, an over-strength factor is defined. The over-strength factor is determined from performance level, torsional resistance and arrangement of walls.

  • PDF

모드 해석을 이용한 등가 지진하중에서의 설계 편심 (Design Eccentricity in Equivalent Seismic Load Using Modal Analysis)

  • 조소훈;이명규
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.268-275
    • /
    • 2001
  • Modal analysis does well predict the elastic dynamic response of the torsionally unbalanced structure. But modal analysis overestimates the rotation of the structure in inelastic range, so one side members require ductility too much and the others require ductility too small in comparison with torsionally balanced structure. In this paper, in order to reduce difference of ductility demand between both side members of the torsionally unbalanced structure, design eccentricity of seismic load is evaluated and the method determining the strength center of structure is proposed using modal analysis. For several cases, the ductility demand of stucture is compared to investigate the propriety of the proposed approach.

  • PDF