AUSPLUME 모델을 이용한 악취를 피하기 위한 산업오염원과 주거단지 사이 이격거리에 관한 연구 (A Study on Separation Distance between Industrial Source and Residential Areas to Avoid Odor Annoyance Using AUSPLUME Model)

  • 정상진
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.393-400
    • /
    • 2002
  • Separation distance between industrial source and residential areas to avoid odor annoyance was investigated using AUSPLUME model. A Gaussian plume model (AUSPLUME) for the dispersion was used to calculate odor emission from ground level area source. Using the dispersion model to calculate ambient odor concentrations, the separation distance between industrial source and residental areas was defined by %HA (percentage of highly annoyed person) and odor percentile concentration (C98). The result was compared with the separation distance of various nation guidelines for livestock buildings. The calculated separation distance for industrial source showed similar pattern comparing with various guidelines for livestock buildings.

완주지역의 VOCs 배출특성에 따른 공단지역과 일반지역의 기여도 분석 (VOCs Emission Characteristics and Mass Contribution Analysis at Wanju Industrial Area)

  • 김득수;양고수;박비오
    • 한국대기환경학회지
    • /
    • 제24권5호
    • /
    • pp.562-573
    • /
    • 2008
  • Concentrations of volatile organic compounds (VOCs) measured from the local industrial sources in Wanju industrial complex during June $2007{\sim}January$ 2008. The samples were collected from the primary sources (6 emission points) in 4 major factories in Wanju industrial complex as well as two general sources in Wanju County to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; fabricated metal manufacture, motor vehicle manufacture, rubber and plastic manufacture, and chemical manufacture factories. Two general source samples were collected from gasoline gas station and dry cleaning shop in urban area. In order to understand the near source influence at receptor, samples from the two receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected with sample canister, and analyzed by using GC/MSD. The concentrations from different sources were compared and discussed. The mass contributions of the speciated VOCs to total VOCs measured from industrial sources and ambient ai r at two receptors were presented and discussed.

전주공단지역의 주요VOCs 배출농도 측정 및 배출원별 특성 분석 (Measurement of VOCs Concentrations at Jeonju Industrial Area and Emission Characteristics)

  • 김득수;양고수;박비오
    • 한국환경과학회지
    • /
    • 제16권3호
    • /
    • pp.299-310
    • /
    • 2007
  • It will be necessary to make proper management plans to preserve the air quality in good level for the public. In order to make these plans, source information and detail emission inventories of the city and near industrial areas should be given. However, lack of the source measurements data makes us more difficult to complete the source inventory. VOC source Inventory could be utilized for the feasibility study to estimate the contribution of VOC sources presenting to the receptor such as residential area. It may give policy maker an idea how to control the air quality, and improve their social environment in the area. This study shows data that measured VOCs concentrations from the local industrial areas in Jeonju during from May 2005 to January 2006. The samples were collected from the near sources in 7 major factories in the industrial park as well as 5 general sources in near city Jeonju area to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; chemical, food, paper, wood, metal, non-metal (glass), and painting (coating) industries. The 5 general sources are sampled from tunnel, gasoline gas station, dry cleaning shop, printing (copy) shop, and road pavement working place in urban area. To understand the near source effect at receptor, samples from the 2 receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected and analyzed for the comparison to source concentration. The mass contributions of the speciated VOC to total mass of VOCs measured from the different sources and ambient (2 receptors) were presented and discussed.

연속 n중 k의 고장 연결 시스템에 있어서 최적 Redundancy 설계 (Optimal Redundancy of the Consecutive k out of n Failure Lines Included or Excluded Sink-Source Parts.)

  • Bok-Man, Kim;Chung-Hwan, Oh
    • 산업경영시스템학회지
    • /
    • 제17권30호
    • /
    • pp.209-214
    • /
    • 1994
  • A consecutive k out of n failure lines with sink-source parts is a system of components in sequence such that the system fails whether some k consecutive components are all fail. Some object, be it a flow, is to be relayed from a source to a sink through a sequence of intermediate stations(components). Now care should be taken as to if the source and the sink are also considered components of the systems, i. e. , whether they serve the same function as the intermediate components (stations). Such systems are different from ordinary consecutive k- out of n failure lines by adding the on source and sink pole[6]. The main properties of the reliability by the optimal redundancy of consecutive k out of n failure lines are presented under this modification.

  • PDF

A STUDY ON INDUSTRIAL GAMMA RAY CT WITH A SINGLE SOURCE-DETECTOR PAIR

  • Kim Jong-Bum;Jung Sung-Hee;Kim Jin-Sup
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.383-390
    • /
    • 2006
  • Having its roots in medical applications, industrial gamma ray CT has opened up new roads far investigating and modeling industrial processes. Using a line of research related to industrial gamma ray CT, the authors set up a system of single source and detector gamma transmission tomography for wood timber and a packed bed phantom. The hardware of the CT system consists of two servo motors, a data logger, a computer, a radiation source and a radiation detector. One motor simultaneously moves the source and the detector for a parallel beam scanning, whereas the other motor rotates the scan table at a preset projection angle. The image is reconstructed from the measured projections by the filtered back projection method. The phantom was designed to simulate a cross section of a packed bed with a void. The radiation source was 20mCi of Cs-137 and the detector was a 1 inch $\times$ 1 inch NaI (TI) scintillator shielded by a lead collimator. The experimental gamma ray CT image has sufficient resolution to reveal air holes and the density distribution inside the phantom. The system could possibly be applied to a packed bed column or a pipe flow in a petrochemical plant.

재난관리 원격 모니터링용 오픈소스 하드웨어 모듈 응용 (Open-Source Hardware Module Application for Remote Monitoring of Disaster Prevention)

  • 진경찬;이은주;이성호
    • 센서학회지
    • /
    • 제24권5호
    • /
    • pp.299-305
    • /
    • 2015
  • Since the natural disasters such as floods, droughts, heat wave and cold wave are increasing, the need for risk management is necessary to minimize the damage with utilizing IT technology. Also, the monitoring services of disaster response type have been developed and applied. Recently, the open source hardware based on the signal of the sensor, or the monitoring studies have been carried. In this paper, by analyzing a low-cost open source hardware platform such as Beagle board, we examine the utilization of the hardware-based module for sensor monitoring.

전자빔 증발원을 이용한 물질의 증발 특성 (Evaporation Characteristics of Materials from an Electron Beam Evaporation Source)

  • 정재인;양지훈;박혜선;정재훈;송민아
    • 한국표면공학회지
    • /
    • 제44권4호
    • /
    • pp.155-164
    • /
    • 2011
  • Electron beam evaporation source is widely used to prepare thin films by physical vapor deposition because it is very effective to vaporize materials and there is virtually no limit to vaporize materials including metals and compounds such as oxide. In this study, evaporation characteristics of various metals and compounds from an electron beam evaporation source have been studied. The 180 degree deflection type electron beam evaporation source which has 6-hearth crucibles and is capable of inputting power up to 10 kW was employed for evaporation experiment. 36 materials including metals, oxides and fluorides have been tested and described in terms of optimum crucible liner, evaporation state, stability, and so on. Various crucible liners have been tried to find out the most effective way to vaporize materials. Two types of crucible liners have been employed in this experiment. One is contact type liner, and the other is non-contact type one. It has been tried to give the objective information and the most effective evaporation method on the evaporation of materials from the electron beam evaporation source. It is concluded that the electron beam evaporation source can be used to prepare good quality films by choosing the appropriate crucible liner.

AERMOD 모델을 이용한 산단 지역 악취 배출량 및 주거지역 영향 범위 평가 (Estimation of Odor Emissions from Industrial Sources and Their Impact on Residential Areas using the AERMOD Dispersion Model)

  • 정상진
    • 한국대기환경학회지
    • /
    • 제27권1호
    • /
    • pp.87-96
    • /
    • 2011
  • In this study, the AERMOD dispersion model was used for predicting odor concentrations and back-calculating industrial area source odor emission rate. The studied area was Sihwa industrial complex in Korea. Odor samples were collected during two days over a year period in 2009. The comparison between the predicted and observed concentrations indicates that the AERMOD model could fairly well predict average downwind odor concentrations. The results show odor emission rates of Sihwa industrial complex area source were ranged from 0.204 to 2.320 $OUms^{-1}$ (average 0.476 $OUms^{-1}$). The results also show wind speed and direction are important parameters to the odor dispersion.

여천공단주변 대기오염이 때죽나무의 생장 특성에 미치는 영향 (Effects of Air Pollution on Physiological characteristics of Styrax japonica in Yeolchon Industrial Complex)

  • 김동근
    • 한국대기환경학회지
    • /
    • 제16권2호
    • /
    • pp.121-128
    • /
    • 2000
  • To identify the effects of air pollution on several physiological characteristics of Styrax japonica in Yeochon industrial comples soil properties photosynthetic capacity and chorophyll contents were investigated. All of these measurements were taken on Styrax japonica stand at 1. 3 and 7km from an industrial complex which is an air pollution source. In addition a Styrax japonica stand in Sang-ju city was selected as a control Each physiological measurement was in leaves of east-, west- south- and north-facing branches. The results obtained were as follows: 1) Al contents of soil in Yeochon industrial complex were higher than those of Sang-ju city a non-polluted area. higheral contents contributed to decrease in soil pH. 2) Chlorophyll contents of leaves at 1km from the industrial complex closest from the air pollution source were lower than those of 3 and 7km/ 3) Photosynthetic capacity of Styrax japonica at 1km from the air pollution source was lower than those at 3 and 7km.

  • PDF

Industrial Source Complex Model을 이용한 3차원 모사에 관한 연구 (A Study on the 3-Dimensional Simulation System using Industrial Source Complex Model)

  • 임동연;김성빈;고재욱
    • 한국가스학회지
    • /
    • 제4권2호
    • /
    • pp.15-19
    • /
    • 2000
  • 본 연구에서는 기존의 연구 개발된 다양한 확산모델의 비교 및 분석을 통하여 국내 석유화학시설에 적용하는 것이 적합하다고 판단되는 미국 EPA의 Industrial Source Complex(ISC)모델을 3차원 모사 대상으로 선정하여, 3차원 모사논리를 적용한 모사시스템을 개발하였다. 따라서 개발된 모사 시스템을 국내 화학산업시설에 적용할 경우, 정확한 사고피해 범위 예측과 더불어 화학산업시설의 비상조치계획 수립, 점화원 관리 등의 사고예방 및 사고피해의 최소화 측면에서도 많은 부분 기여할 수 있을 것이다.

  • PDF