• Title/Summary/Keyword: industrial area

Search Result 6,047, Processing Time 0.037 seconds

Application of peak load for industrial water treatment plant design (공업용수 정수장 설계시 첨두부하 적용방안)

  • Kim, Jinkeun;Lee, Heenam;Kim, Dooil;Koo, Jayong;Hyun, Inhwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.225-231
    • /
    • 2016
  • Peak load rate(i.e., maximum daily flow/average daily flow) has not been considered for industrial water demand planning in Korea to date, while area unit method based on average daily flow has been applied to decide capacity of industrial water treatment plants(WTPs). Designers of industrial WTPs has assumed that peak load would not exist if operation rate of factories in industrial sites were close to 100%. However, peak load rates were calculated as 1.10~2.53 based on daily water flow from 2009 to 2014 for 9 industrial WTPs which have been operated more than 9 years(9-38 years). Furthermore, average operation rates of 9 industrial WTPs was less than 70% which means current area unit method has tendency to overestimate water demand. Therefore, it is not reasonable to consider peak load for the calculation of water demand under current area unit method application to prevent overestimation. However, for the precise future industrial water demand calculation more precise data gathering for average daily flow and consideration of peak load rate are recommended.

Simulated Annealing for Reduction of Defect Sensitive Area Through Via Moving (Via 이동을 통한 결함 민감 지역 감소를 위한 시뮬레이티드 어닐링)

  • Lee, Seung Hwan;Sohn, So Young
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.28 no.1
    • /
    • pp.57-62
    • /
    • 2002
  • The semiconductor industry has continuously been looking for the ways to improve yield and to reduce manufacturing cost. The layout modification approach, one of yield enhancement techniques, is applicable to all design styles, but it does not require any additional resources in terms of silicon area. The layout modification method for yield enhancement consists of making local variations in the layout of some layers in such a way that the critical area, and consequently the sensitivity of the layer to point defects, is reduced. Chen and Koren (1995) proposed a greedy algorithm that removes defect sensitive area using via moving, but it is easy to fall into a local minimum. In this paper, we present a via moving algorithm using simulated annealing and enhance yield by diminishing defect sensitive area. As a result, we could decrease the defect sensitive area effectively compared to the greedy algorithm presented by Chen and Koren. We expect that the proposed algorithm can make significant contributions on company profit through yield enhancement.

Concentrations of SPM and Ambient Hazardous Heavy Metals in an Industrial Complex Area in Daegu City (대구시 산단지역 대기 중 SPM과 유해중금속성분의 농도)

  • Song, Hee-Bong;Kwon, Jong-Dae;Park, Su-Kyoung;Kim, Eun-Kyung;Yoon, Hyun-Suk;Ju, Myeong-Hui;Bae, Gi-Soo
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.4
    • /
    • pp.259-267
    • /
    • 2015
  • Objectives: This study evaluated the regional and seasonal concentrations of ambient hazardous heavy metals in an industrial complex area in Daegu City. Methods: A total of 64 SPM (Suspended Particulate Matter) samples were collected in non-industrial and industrial areas during 2014 and were analyzed for hazardous heavy metals elements (As, Cd, Mn, Ni, Pb) with ICP after acid extraction. Results: SPM and hazardous heavy metals concentrations showed regional (industrial complex area>non-industrial complex area) and seasonal (spring, winter>fall, summer) variations. All of the hazardous heavy metals were influenced by anthropogenic sources. The pollution index of hazardous heavy metals was very low, showing roughly one-quarter of the level of the air quality guidelines of WHO. The correlation analysis among SPM and hazardous heavy metals indicated that components of non-industrial complex areas were more related to each other than those of industrial complex areas, and the correlation in the winter was higher than in other seasons. Conclusion: It is necessary to control air pollution sources and establish related policy because hazardous heavy metals from industrial areas can influence residential areas.

Diversity Analysis of Diazotrophic Bacteria Associated with the Roots of Tea (Camellia sinensis (L.) O. Kuntze)

  • Arvind, Gulati;Sood, Swati;Rahi, Praveen;Thakur, Rishu;Chauhan, Sunita;Nee Chadha, Isha Chawla
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.6
    • /
    • pp.545-555
    • /
    • 2011
  • The diversity elucidation by amplified ribosomal DNA restriction analysis and 16S rDNA sequencing of 96 associative diazotrophs, isolated from the feeder roots of tea on enriched nitrogen-free semisolid media, revealed the predominance of Gram-positive over Gram-negative bacteria within the Kangra valley in Himachal Pradesh, India. The Gram-positive bacteria observed belong to two taxonomic groupings; Firmicutes, including the genera Bacillus and Paenibacillus; and Actinobacteria, represented by the genus Microbacterium. The Gram-negative bacteria included ${\alpha}$-Proteobacteria genera Brevundimonas, Rhizobium, and Mesorhizobium; ${\gamma}$-Proteobacteria genera Pseudomonas and Stenotrophomonas; and ${\beta}$-Proteobacteria genera Azospira, Burkholderia, Delftia, Herbaspirillum and Ralstonia. The low level of similarity of two isolates, with the type strains Paenibacillus xinjiangensis and Mesorhizobium albiziae, suggests the possibility of raising species novum. The bacterial strains of different phylogenetic groups exhibited distinct carbon-source utilization patterns and fatty acid methyl ester profiles. The strains differed in their nitrogenase activities with relatively high activity seen in the Gramnegative strains exhibiting the highest similarity to Azospira oryzae, Delftia lacustris and Herbaspirillum huttiense.

Measurement of VOCs Concentrations at Jeonju Industrial Area and Emission Characteristics (전주공단지역의 주요VOCs 배출농도 측정 및 배출원별 특성 분석)

  • Kim, Deug-Soo;Yang, Go-Soo;Park, Bi-O
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.299-310
    • /
    • 2007
  • It will be necessary to make proper management plans to preserve the air quality in good level for the public. In order to make these plans, source information and detail emission inventories of the city and near industrial areas should be given. However, lack of the source measurements data makes us more difficult to complete the source inventory. VOC source Inventory could be utilized for the feasibility study to estimate the contribution of VOC sources presenting to the receptor such as residential area. It may give policy maker an idea how to control the air quality, and improve their social environment in the area. This study shows data that measured VOCs concentrations from the local industrial areas in Jeonju during from May 2005 to January 2006. The samples were collected from the near sources in 7 major factories in the industrial park as well as 5 general sources in near city Jeonju area to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; chemical, food, paper, wood, metal, non-metal (glass), and painting (coating) industries. The 5 general sources are sampled from tunnel, gasoline gas station, dry cleaning shop, printing (copy) shop, and road pavement working place in urban area. To understand the near source effect at receptor, samples from the 2 receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected and analyzed for the comparison to source concentration. The mass contributions of the speciated VOC to total mass of VOCs measured from the different sources and ambient (2 receptors) were presented and discussed.

A Case Study for Development of the Block Arrangement on Fixed Area and Scheduling System (고정 정반에서의 블록 배치 및 일정계획 시스템 개발 사례연구)

  • Min Sang-Gyu;Lee Sang-Hyup;Kim Ji-On;Ha Seung-Jin;Choi Tae-Hoon
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2005.06a
    • /
    • pp.159-164
    • /
    • 2005
  • In this paper, we study some problems of the scheduling on the fixed area in a shipbuilding. The scheduling, constrainted a working area, is not easy to make a load balance and to operate a change of daily work plan. we proposed a block arrangement algorithm to make the load balance and developed a system used to operate the change of daily work plan.

  • PDF

VOCs Emission Characteristics and Mass Contribution Analysis at Wanju Industrial Area (완주지역의 VOCs 배출특성에 따른 공단지역과 일반지역의 기여도 분석)

  • Kim, Deug-Soo;Yang, Go-Soo;Park, Bi-O
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.562-573
    • /
    • 2008
  • Concentrations of volatile organic compounds (VOCs) measured from the local industrial sources in Wanju industrial complex during June $2007{\sim}January$ 2008. The samples were collected from the primary sources (6 emission points) in 4 major factories in Wanju industrial complex as well as two general sources in Wanju County to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; fabricated metal manufacture, motor vehicle manufacture, rubber and plastic manufacture, and chemical manufacture factories. Two general source samples were collected from gasoline gas station and dry cleaning shop in urban area. In order to understand the near source influence at receptor, samples from the two receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected with sample canister, and analyzed by using GC/MSD. The concentrations from different sources were compared and discussed. The mass contributions of the speciated VOCs to total VOCs measured from industrial sources and ambient ai r at two receptors were presented and discussed.

Odorous Pollutant Concentration Levels in the Ban-Wall Industrial Area and Its Surrounding Regions (산업단지 및 주거지역에 대한 환경대기 중 주요 악취물질의 농도특성에 관한 연구 - 안산시 반월공단을 중심으로 -)

  • Choi, Ye-Jin;Kim, Ki-Hyun;Jeon, Eui-Chan
    • Journal of the Korean earth science society
    • /
    • v.27 no.2
    • /
    • pp.209-220
    • /
    • 2006
  • In this study, the distribution patterns of major odorous compounds in ambient air were investigated in the areas surrounding the Ban-Wall industrial complex of Ansan, Korea (Aug. 2004 to Sep. 2005). The results indicated the environmental significance of several major odorous compounds which include carbonyl compounds, reduced sulfur compounds (RSC), and volatile organic compounds (VOC). When the results were compared on a diurnal basis, the afternoon time concentration of most odorous compounds were notably higher than their morning time counterparts. It also indicated that the odor concentrations differed greatly, in terms of spatial grouping scheme of data sets, such as between industrial area and non-industrial area. The comparison of spatial patterns indicated that the concentrations of most of the compounds at the industrial area were maintained at high concentration levels, compared to the surrounding areas. The overall results of this study thus suggest that the distribution of odorous compounds in a large industrial complex can exhibit a unique pattern of their own.

Geology of Nogsan National Industrial Engineering Estate (녹산국가공단 조성지 일대의 토목 지질)

  • 안명석;김종대
    • Explosives and Blasting
    • /
    • v.18 no.3
    • /
    • pp.99-106
    • /
    • 2000
  • The geology of Nogsan industrial estate area, Pusan, Korea consists mainly of andesitic rocks, rhyolitic rocks and hornblende granite. They are then intruded by basic and acidic dikes. All of the igneous activities in this area are in Cretaceous time, that is the lower part of Silla group in Gyoungsang basin. Andesitic volcanic rocks are distributed in two separate basines: Saengok basin and Doodong basin. Although both basines contain andesite and andesitic breccia(Kab), younger andesitic activity was more active to the western Doodong basin giving very little influence on the eastern Saengok basin. Sediments in the area are quarternaly alluvium and colluvium. Alluvium is very thick and consists mainly of silt and clay deposited as delta deposits at the mouth of Nakdong river. Colluvium in the area is short distributary channel deposits. The area is largely filled with socks and sediments to build industrial estates especially on the delta deposits at Shinhodong area and on the shoreline mud bed between Yongwondong and Shinhodong. A careful investigation to avoid the possibility of a large scale mud flow is suggested because it could be trigered by many reason such as an earthquake or a flood on the land where a heavily loaded salt-water may soaked into the muddy bed lying on the granitic basement gently dipping toward the ocean. Althouth the area is in the Yangsan fault zone no ground evidence of fault can be seen despite the RESTEC sattlite image gives excelent traces of linearments in the area.

  • PDF

A Study on the Effective Safety Education Plan to Prevent Industrial Disaster - Focused on to small and medium enterprises in Incheon area - (산업재해 예방을 위한 효과적 안전교육방안 연구 - 인천지역 중소기업을 대상으로 -)

  • Lee, Baek-Hyun;Jung, Soo-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.2
    • /
    • pp.19-31
    • /
    • 2007
  • If you examine the Industrial Disaster Analysis Content that occurs every year in the small and medium enterprise, industrial disaster occurs because of manager's lack of safety and worker's unprepared safety education. Therefore effective safety education systems are needed to offer adequate knowledge and technology to the workers. On this research, to give an effective education way to decrease industrial disaster we administered to the workers who are in charge of 300 workplace in Incheon area to search actual condition of industrial disaster and to disclose a link between industrial disaster and industrial safety education. We put in effect on frequency study and examined x2 using SPSSWIN 10.0. On the research, the results shows that the industrial safety education and training are in effect regularly and the satisfaction are low. But the manager's satisfactions are high through safety education. So it shows that we need to find a way to put in effect safety education to satisfy the workers.