• 제목/요약/키워드: induction generator

검색결과 415건 처리시간 0.028초

유도발전기 역률 보상 콘덴서와 직렬 리액터의 동작 분석 (Operating Analysis of Power Factor Compensation Condenser and Series Reactor in the Induction Generator)

  • 김종겸;박영진
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.593-598
    • /
    • 2017
  • Induction generator is always required reactive power in order to generate a rotating magnetic field as an inductive load. The reactive power must be continuously supplied to the induction generator as well as load of distribution system from the power supply side. So the power factor of the power supply side during the induction generation operation is low. Condenser is installed in order to raise the low power factor of the induction generator. Switching transients occurs when the power supply of the capacitor is turned on in order to ensure the low power factor. When using the reactor in series with the capacitor in order to reduce the influence of switching transient, it can affect the reactive power by the condenser voltage rises. In this study, we analyzed the operating characteristics for power and power factor of induction generator in accordance with the presence or absence of the application of the serial reactors for switching transients reduction of the condenser and the condenser for power factor correction.

계통 연계형 권선형 유도발전기의 동작특성 연구 (Study on the Operating Characteristics of Double Fed Induction Generator Connected AC network)

  • 김찬기;한상열;추진부
    • 전력전자학회논문지
    • /
    • 제11권3호
    • /
    • pp.247-257
    • /
    • 2006
  • 본 논문은 이중여자권선을 갖는 권선형 유도발전기와 농형유도발전기사이의 운전특성비교를 보여준다. 농형유도발 전기는 자화리액턴스에 의한 무효전력소비 때문에, 역률을 보상하기 위한 콘덴서를 필요로 하나, DFIG는 회전자에 Back-To Back컨버터를 가지고 있기 때문에 저속/고속에서 유도발전기가 운전이 가능하다. 본 논문에서는 PSCAD/TMTDC를 이용하여 농형유도기와 DFIG의 응답특성이 분석되었다.

인버어터 여자에 의한 유도발전기의 연구 (A Study on the Inverter-Excited Induction Generator)

  • 박민호;김진오;김경수;정승기
    • 대한전기학회논문지
    • /
    • 제34권8호
    • /
    • pp.331-337
    • /
    • 1985
  • An inverter-excited induction generator is discussed in this paper. A brief review of the capacitor-excited induction generator is given and the steady state characteristics of the induction generator excited by an inverter are evaluated. It is shown that the output voltage of the system can be controlled by adjusting the slip, for given operating conditions. The introduction of feedback control makes it possible to control the output voltage stably over the wide range of speed and load. Experimental results are given. The output of the induction generator is then converted into a CVCF(Constant Voltage-Constant Frequency) power source using a PWM inverter with simple control circuit.

  • PDF

계통 연계형 권선형 유도발전기의 동작특성 연구 (Study on the Operating Characteristics of Double Fed Induction Generator Connected AC network)

  • 김찬기;박종광;최영도;임성주;문형배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.323-326
    • /
    • 2006
  • This paper shows the comparison of operating characteristics between squirrel cage induction generator and DFIG(Double Fed Induction Generator). Because squirrel cage induction generator consume the reactive power due to magnetizing reactance, the capacitor is need to compensate the reactive power. Otherwise, two back-to-back PWM voltage-fed inverters connected between the stator and the rotor allow sub/super synchronous operation with low distortion currents. In this paper, the response characteristics of squirrel cage induction generator and DFIG, were analyzed and investigated using PSCAD/EMTDC.

  • PDF

풍력발전시스템이 연계된 계통의 과도상태해석 (Transient State Analysis of Network Connected to Wind Generation System)

  • 김세호
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.29-35
    • /
    • 2003
  • Generator for wind power can be either synchronous or asynchronous (induction) types. Induction and synchronous generators behave in a different way when subjected to severe faults. Induction generators does not have an angle stability limit and short circuit in the neighborhood of an Induction generator causes the demagnetization of the machine when the fault is cleared, the voltage raises slowly, while the grid contributes with reactive power to the generator and the magnetic flux recovers. On the other hand in the synchronous generators the recovery of the voltage is immediate, since the excitation of the rotor angle comes from an independent circuit. This paper shows the result of the transient state analysis in the network connected to wind generation system Several case studies have been conducted to determine the effect of the clearing time of a fault on the network stability. It has been found that the critical clearing time can be as low as 61ms in the case of induction generator compared to 370ms in the case of synchronous generator.

Performance of Double Fed Induction Machine at Sub- and Super-Synchronous Speed in Wind Energy Conversion System

  • Eskander, Mona N.;Saleh, Mahmoud A.;El-Hagry, Mohsen M.T.
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.575-581
    • /
    • 2009
  • In this paper two modes of operating a wound rotor induction machine as a generator at sub-and super-synchronous speeds in wind energy conversion systems are investigated. In the first mode, known as double fed induction generator (DFIG), the rotor circuit is fed from the ac mains via a controlled rectifier and a forced commutated inverter. Adjusting the applied rotor voltage magnitude and phase leads to machine operation as a generator at sub-synchronous speeds. In the second mode, the machine is operated in a slip recovery scheme where the slip energy is fed back to the ac mains via a rectifier and line commutated inverter. This mode is described as double output induction generator (DOIG) leading to increase the efficiency of the wind-to electrical energy conversion system. Simulated results of both modes are presented. Experimental verification of the simulated results are presented for the DOIG mode of operation, showing larger amount of power captured and better power factor when compared to conventional induction generators.

권선형 유도발전기의 CVCF 발전을 위한 2자여자제어법에 관한 연구 (A Study on the 2nd Exitation for CVCF Generation of Doubly-fed Induction Generator)

  • 안진우;황영문
    • 대한전기학회논문지
    • /
    • 제40권7호
    • /
    • pp.656-663
    • /
    • 1991
  • This paper deals with the control strategy for the constant voltage, constant frequency (CVCF) generation of doubly -fed induction generator. Since induction machine is a nonlinear and multivariable one, the influential factors for CVCF generation of induction generator are the magnitude of output voltage, load current and its power factor, slip of the machine, etc. To get appropriate control scheme and study the effect of its parameters, the control equation of induction machine is derived and tested. The simulation and test results show that suggested equation and control system are very useful strategy for the CVCF control of induction generator.

  • PDF

Sliding Mode Control of a New Wind-Based Isolated Three-Phase Induction Generator System with Constant Frequency and Adjustable Output Voltage

  • Moradian, Mohammadreza;Soltani, Jafar
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.675-684
    • /
    • 2016
  • This paper presents a new stand-alone wind-based induction generator system with constant frequency and adjustable output voltage. The proposed generator consists of a six-phase cage-rotor induction machine with two separate three-phase balanced stator windings and a three-phase space vector pulse width modulation inverter that operates as a static synchronous compensator (STATCOM). The first stator winding is fed by the STATCOM and used to excite the machine while the second stator winding is connected to the generator external load. The main frequency of the STATCOM is determined to be constant and equal to the load-requested frequency. The generator output frequency is independent of the load power demand and its prime mover speed because the frequency of the induced emf in the second stator winding is the same as this constant frequency. A sliding mode control (SMC) is developed to regulate the generator output voltage. A second SMC is used to force the zero active power exchanged between the machine and the STATCOM. Some simulation and experimental results are presented to prove the validity and effectiveness of the proposed generator system.

권선형유도발전기를 갖는 신재생에너지 시스템을 위한 전압벡터 동기화 기법 (A Voltage Vector Synchronization Method for a Renewable Energy System with a Doubly-Fed Induction Generator)

  • 박정우;이기욱;김동욱
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.547-555
    • /
    • 2007
  • In order to transmit energy generated through the stator winding of a doubly-fed induction generator (DFIG), we need to synchronize the generated voltage vector with the grid voltage vector. However, the existing synchronization methods work only when the encoder is installed at a specific position and equivalent constant is precise. In order to solve this problem, a new synchronization method has been proposed and a way of applying the method to existing doubly-fed induction generator control algorithm has been also proposed. The validities of the methods proposed were verified by using a prototype converter for a 1.5MW-class doubly-fed induction generator and experimental results showed the validity of that against variation of an encoder positions, generator parameters, and grid voltages.

불평형 부하 운전시 3상 유도발전기 특성 해석 (Characteristics Analysis of 3-phase Induction Generator at the Unbalanced Load Operation)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제56권3호
    • /
    • pp.123-128
    • /
    • 2007
  • Hydro power supplies no pollution energy, mainly induction generator has been applied at the small capacity power station. The generating power of small hydro-electric power station connects on the 22.9kV distribution system or low voltage system in the case of three-phase four-wire supply system. There are side effects of various kinds in the 3-three phase 4-wire distribution system mixing 1-phase load and 3-phase load. This system generates the voltage unbalance by unbalanced load operating condition. They have various serious effects on generator and connection system. In this paper, we analyzed what kind of operation characteristic are happened in the induction generator by customer load variation at the 3-three phase 4-wire distribution system.