• 제목/요약/키워드: inductance removal

검색결과 7건 처리시간 0.022초

22.9kV, 50MVA급 초전도 전력케이블 DC $I_c$ 측정에 관한 연구 (The study on the DC Ic measurement in the 22.9kV, 50MVA HTS power cable)

  • 최석진;이상진;심기덕;조전욱;장현만;이수길;손송호;황시돌
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.28-31
    • /
    • 2008
  • 22.9kV 50MVA HTS power cable has been developed and tested by Korea Electrotechnology Research Institute and LS Cable Company and it was supported by a grant from Center for Applied Superconductivity Technology of the 21st Century Frontier R&D Program. In this paper, DC Ic of 100m HTS cable which is installed at Kochang testing station was measured and analyzed. A measurement technique of DC Ic used by resistance and inductance removal method is established.

와전류 센서를 이용한 금속 모재 선별에 관한 연구 (A Study on sorting out base metal using eddy current sensor)

  • 이길승;김태옥;김화영;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1788-1792
    • /
    • 2005
  • Eddy current sensor is representative instrument measuring gap to base metal and sensing trouble in base metal. The existing eddy current sensor works as measuring variance of sensor coil's inductance. But, sensor coil have phenomenon that not only inductance but also real resistance varies in real action. Conductivity and Permeability are main variable in sensor coil's varying impedance(inductance, real resistance). By searching relationship between conductivity-permeability and sensor coil's impedance, eddy current sensor gain advantage of elevation of accuracy, removal of alignment to each base metal, and continuous sensing to varying base metal.

  • PDF

내부 코일형 박막 인덕터의 특성에 미치는 열처리 효과 (Annealing Effect on the Characteristics of Thin Film Inductors with Inner Coil Type)

  • 민복기;김현식;송재성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권5호
    • /
    • pp.333-338
    • /
    • 1999
  • Thin film inductors of $10 mm \times 10 mm$ with inner coil type of 14 turns were fabricated by sputtering, photo-masking, and etching processes. Their characteristics of impedances and annealing after were investigated. The properties of impedances of the thin film magnetic core inductors with inner coil type were improved by magnetic field annealing due to the removal of residual stress and the improvement magnetic properties of magnetic films. But the characteristics of frequency of the thin film magnetic core inductors were not improved by magnetic field annealing due to properties of the spiral pattern and inner coil type. The thin film magnetic core inductor annealed by uniaxal field annealing method showed an inductance of 1000 nH and resistance of$ 6 \Omega$ of 1 at 2 MHz.

  • PDF

22.9kV/50MVA급 고온초전도 전력케이블의 DC Ic 측정 및 교류손실에 관한 연구 (The study on the DC Ic measurement and AC loss in the 22.9kV, 50MVA HTS power cable)

  • 최석진;이상진;심기덕;조전욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.808-809
    • /
    • 2008
  • 22.9kV 50MVA HTS power cable has been developed and tested by Korea Electrotechnology Research Institute and LS Cable Company and it was supported by a grant from Center for Applied Superconductivity Technology of the 21st Century Frontier R&D Program. In this paper, DC Ic of 100m HTS cable which is installed at Kochang testing station was measured and analyzed. A measurement technique of DC Ic used by resistance and inductance removal method is established. The HTS power cable is composed of 2 layers for transmission and 1 layer for shield. For the analysis of AC losses in an HTS power cable, 2-dimensional numerical calculation was carried out to define the magnetic field distribution. We calculated the magnetization losses in the HTS core of that cable from these fields. These calculated results are in accordance with those of experiment.

  • PDF

변압기 부분방전 상시 감시기법에 관한 연구 (A Study on the on Line Monitoring Techniques of the Partial Discharge for Transformer)

  • 권동진;박재준
    • 한국전기전자재료학회논문지
    • /
    • 제14권12호
    • /
    • pp.1032-1040
    • /
    • 2001
  • In order to apply the partial discharge measuring technique utilizing electrical pulse to the transformer at sites, this paper describes the measuring technique obtaining only the signals due to internal partial discharge in the transformer, but the noises due to external corona which has been a major problem so far. At first, partial discharge and corona noise were simultaneously generated in the model transformer by using needle-plane electrodes and rod-sphere electrodes out of it in a high voltage laboratory, respectively. It was verified that only the partial discharge signals in the transformer could be measured by removing the noise signals from the superposed signals of partial discharges and noises on the grounding wire of the model transformer. By application to a 345kV transformer in service, it was also confirmed that the partial discharge could be on-line monitored by removing the noise signals measured by the inductance sensor on the grounding wire of a 154kV lightning arrester from the superposed signals of internal partial discharge and external corona noise measured by bushing tap coupler of the transformer.

  • PDF

환형 무전극 형광램프의 전자계 시뮬레이션, 전기적 및 광학적 특성 (Electromagnetic Simulation of Ring-shaped Electrodeless fluorescent Lamps and its Electrical and Optical Characteristics)

  • 최용성;조주웅;이영환;김광수;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제17권5호
    • /
    • pp.552-559
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficiency replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program(Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250 KHz and some specific conditions. The optical characteristics were measured luminance and a temperature and an optical spectrum distribution for 10 min in a one minute interval at the same time. With a goal of finding alternative materials, we show measurement results of electrical characteristics of a ring-shaped electrodeless fluorescent lamp as a function of frequency and the number of coil turns using a highly permeable($\mu$$_{r}$(equation omitted) 2,000) Mn-Zn ferrite. These results are compared with those of conventional ring-shaped electrodeless fluorescent lamp. It is found that the resistance, inductance and impedance are increased while the quality factor decreases as frequency increases.s.

유도가열 기법을 이용한 저주파 용접예열 시스템 구현 (Implementation of Low Frequency Welding Pre-heating System Using Induction Heating)

  • 양주영;김수찬;박준모
    • 융합신호처리학회논문지
    • /
    • 제19권2호
    • /
    • pp.61-67
    • /
    • 2018
  • 용접예열은 본 용접 전에 금속이 융착되는 모재면을 일정한 온도로 가열하는 것을 의미한다. 냉각속도 조절에 따른 재료 경화 정도 감소, 불순물 편석억제, 열적 변형방지, 그리고 수분제거 등 인접 영향부의 균열을 방지할 수 있다. 이러한 이유에서 고품질의 용접을 위하여 반드시 필요한 작업이다. 유도가열은 전자기유도 현상을 응용하여 전기에너지를 열에너지로 변환시키는 효율적인 가열방식이다. 기체 및 액체를 이용한 연소발열과 비교하여 신속한 가열뿐만 아니라 청결하고, 안정적이며, 경제적이다. 단순한 구조로 주파수와 코일의 형태를 변형하여 가열체의 형상, 깊이, 재질에 관계없이 가열할 수 있다. 본 논문에서는 유도가열 기법을 이용하여 저주파 용접예열 시스템을 구현하였으며, 3종의 자동차 변속기 부품을 대상으로 권선코일 내에서 각 변속기 높이에 따라 권선코일 저항, 인덕턴스 및 자동차 변속기 부품의 온도변화를 관찰한 결과 전류의 변화는 저주파 가열에 있어 매우 중요한 요인으로 작용함을 확인하였다.