• 제목/요약/키워드: induced magnetic intensity

검색결과 54건 처리시간 0.03초

메트로니다졸에 의해 유발된 가역적 뇌증 2례 (Reversible Metronidazole-induced Encephalopathy)

  • 지기환;이정;윤창호;하충건
    • 대한임상독성학회지
    • /
    • 제4권2호
    • /
    • pp.131-136
    • /
    • 2006
  • Metronidazole is an antimicrobial drug widely used against various types of infectious agents, including protozoa, amoeba, Helicobacter pylori, and anaerobes. Metronidazole may produce some adverse effects on hematologic, immunologic, neurologic and other systems. We report a case of reversible metronidazole-induced encephalopathy. The toxic dose of metronidazole and the onset of encephalopathy were variable. Two patients showed abnormally high signal intensity in the bilateral dentate nucleus of cerebellum, and characteristic abnormalities were detected by brain magnetic resonance imaging (MRI) and T2-weighted images, fluid-attenuated inversion recovery images and/or diffusion weighted imaging (DWI). Discontinuation of metronidazole resulted in the improvement of the neurologic symptoms over a period of two to three weeks. We followed up the brain MRI with DWI in one case following obvious clinical improvement, and the previously detected lesion had disappeared.

  • PDF

펠티어 소자를 사용한 Low Drift Flux Meter의 기초연구 (A Basic Study on the Low Drift Flux Meter by Using a Peltier Device)

  • 김철한;허진;신광호;사공건
    • 한국전기전자재료학회논문지
    • /
    • 제14권11호
    • /
    • pp.912-916
    • /
    • 2001
  • Fluxmeter is a measuring instrument the magnetic flux intensity by means of an integration of the voltage induced to a search coil to unit time. It also is required to a precise integrator since the voltage induced to a search coil has a differential value of the flux ${\Phi}$ to unit time. In this study, a bias current which is a main problem of the integrator in a drift troublesome depending on the temperature of a FET is investigated. We have confirmed that the temperature dependence of both the bias current of a integrator using the FET and the reversal saturated current of the minor carrier in a P-N junction of a semiconductor were the same. The property of a commercial integrator goes rapidly down with increasing temperature. The bias current of a FET is increased twice as much with 10$^{\circ}C$ increment. As a result, the low drift integrator could be developed by setting the lower temperature up with a pottier device.

  • PDF

접속형 가변 전자계 자극에 대한 경락반응특성 (Response Properties of Meridians for focused variable electromagnetic stimulus)

  • 이균정;조동국;김수병;권선민;신태민;이경중;이용흠
    • 한국정보통신학회논문지
    • /
    • 제13권7호
    • /
    • pp.1399-1410
    • /
    • 2009
  • 통증을 치료하기 위한 방법으로 약물요법, 신경차단법, 외과적 수술 등이 있으며, 대체물리요법으로 침구치료, 초음파, 전기 치료, 자기장 치료 등이 응용되고 있다. 이중 전기치료 요법이 많이 이용되고 있으나, 피부나 피하조직의 임피던스에 큰 영향을 받으며, 주로 경피자극이 주된 방법으로 효과가 매우 확률론적이다. 본 연구에서는 집속형 자기장을 이용하여 경혈이나 치료점에 대한 국소 부위를 비침습적으로 자극 할 수 있는 새로운 시스템을 개발하였다. 수기자극과 유사한 자극을 유도할 수 있는 새로운 자기장 침 전극(자기장 자극의 효율성을 고려하여 새로운 형태)을 설계하였다. 개발된 시스템의 임상적 유효성 및 신뢰성을 평가하기 위하여 수기자극과 자기장 자극에 대한 경락전위변화를 측정하여 비교하였다. 실험 결과 자기장 자극 시 수기자극을 할 때 나타나는 충전 방전 형태의 전위변화와 유사한 경락전위변화가 측정되었으며, 자극방식, 세기, 빈도를 조절함에 따라 다양한 반응특성이 나타남을 확인하였다. 또한, 전자기장 자극에 의해 경락전위변화를 유도할 수 있어 이를 이용한 새로운 경혈자극 및 통증치료기로써의 가능성을 확인하였다.

두 개내 초급성 출혈 : EPI와 다른 MR 영상 기법의 비교 (Hyperacute Intracerebral Hemorrhage : Comparison of EPI and Other MR Sequence)

  • 김정희;김옥화;서정호;박용성
    • Investigative Magnetic Resonance Imaging
    • /
    • 제3권2호
    • /
    • pp.167-172
    • /
    • 1999
  • 목적 : Echo planar image (EPn와 다론 MR 영상기법에서 2시간 이내의 초급성 출혈의 발견율의 차이를 비교해 보고자 한다. 대상 및 방법 : 인위적으로 뇌출혈을 유발시킨 백서 10마리를 대상으로 EP1, 급속 스핀에코 (FSE) T2 강조영상, Fluid attenuated inversion recovery (FLAIR) 영상, 스펀에코 (SE) Tl 강조영상과 Tl 강조 Gradient echo (GE) 영상을 이용하여, 뇌출혈을 일으킨 2시간 후에 MR 촬영을 하였다. 추가적으로 3마리는 출혈 30분 후에, 6마리는 1시간 후에 각각 EPI와 FSE T2 강조영상을 얻었다. 얻어진 영상에 대한 주관적인 시각적 평가를 하기위하여 세명의 방사선과 의사가 출혈 병변이 어느 MR 영상 기법에서 제일 잘 보이는지를 평가하였다. 정량적인 평가 로는 병변-정상 뇌설질의 대조잡음비(contrast-to-noise ratio, CNR)를 측정하였다. 통계처리는 Wilcoxon-Ranks test를 이용하였다. 결과 : 시각적 평가에서 출혈 병변이 높은 신호강도로 나타난 EP1, FLAIR, FSE T2 영상 중 EPI 영상이 특히 높은 신호강도로 나타나 제일 쉽게 병변이 구별되었다. 정량적인 평가에서 출혈 병 변-정상 뇌설질의 CNR은 EPI와 FLAIR 영상에서 다른 세 영상기법에 비해 통계적으로 유의하게 우월하였다 (p<0.01). 그러나 EPI와 FLAIR 영상간의 CNR은 동계적으로 유의한 차이가 없었다 (p>0.10). 추가적으로 출혈 30분과 1l시간 후 촬영한 모두에서 EPI영상과 FSE T2 강조 영상은 정상에 비해 높은 신호강도를 보여 병변의 구별이 가능하였다. 결론 : 백서에서 유발시킨 초급성기 뇌출혈의 여러 기법의 MR 영상 중 EPI 영상이 영상획득 시간이 가장 빠르면서 시각적 평가와 정량적 평가에서 출혈의 발견율이 가장 높아 출혈의 선속한 진단에 유용할 것으로 생각된다.

  • PDF

경두개 자기자극 시 운동신경 유발응답 측정을 위한 근전도 측정 시스템 구축 (Establishing EMG Measurement System for Measurement of Motor Nerve Response in Transcranial Magnetic Stimulation)

  • 이근용;김수환;조재현;윤세진;이상식
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권4호
    • /
    • pp.413-418
    • /
    • 2019
  • 뇌와 관련된 질병(치매, 조현병, 우울증, 파킨슨병 등)을 가진 환자의 치료 및 재활 정도의 진행을 확인하고자 하는 연구가 현재 활발히 진행되고 있는 추세이다. 그 중에서 경두개 자기 자극법(Transcranial magnetic stimulation, TMS)은 뇌 질환이 있는 환자에게 비 침습적으로 뇌 신경 조절에 사용되는 기법이기 때문에 치료에 많이 사용되고 있다. 경두개 자기 자극 시 정상인의 근피로도는 증가하는 경향을 확인할 수 있다. 따라서 본 논문에서는 경두개 자기 자극 시에 운동 신경 유발 응답 측정을 위한 근전도 측정 시스템을 구축하여 피실험자의 Raw Data를 RMS 기법으로 분석하고, RMS 그래프의 경향을 통해 운동 신경 유발 응답 측정 시스템을 확인하고자 하는 것이 목표이다. 실험 방법으로는 피실험자의 위팔두갈래근의 수축과 이완 운동을 통해 피로한 상황까지 도달하게 한 후, 표면 근전도 기기를 통해 받아들인 원신호를 RMS 기법으로 분석한다. 실험 결과, RMS 그래프가 상승하는 경향을 확인 하였고, 이를 통해 구축된 근전도 측정 시스템으로 운동 신경 유발 응답을 측정한 데이터를 고려하여 개개인에 맞는 자기자극 강도 결정에 활용될 수 있을 것으로 사료된다.

레이저에 의해 생성된 Si 박막의 주기적 표면 구조에서의 도파모드 공진 연구 (Guided-mode Resonances in Periodic Surface Structures Induced on Si Thin Film by a Laser)

  • 이지혁;이윤주;홍현;조은솔;박지영;김주현;강민진;황의선;정병호
    • 한국광학회지
    • /
    • 제34권6호
    • /
    • pp.241-247
    • /
    • 2023
  • 본 연구에서는 355 nm 파장의 나노초 레이저를 비정질 실리콘 박막에 조사하여 형성된 주기적 laser-induced periodic surface structure (LIPSS) 구조의 분광학적 특성을 연구하였다. 지름 196 ㎛의 가우시안 빔을 단위면적당 레이저 펄스 190-280회, 레이저 빔의 세기는 100-130 mJ/cm2 범위에서 'ㄹ' 자 형태로 2차원 스캔하였다. 그 결과 Si 박막 표면에 ~300 nm 주기의 LIPSS 구조가 레이저 편광에 수직 방향으로 정렬되었다. 시료의 투과율 스펙트럼을 측정하여 transverse-electric 편광과 transverse-magnetic 편광에 대해서 각각 700 nm, 500 nm 근방에서 dip이 관측되었다. 이 현상을 설명하기 위해 1차원 격자구조 모델을 이용하여 rigorous coupled-wave analysis를 이용한 시뮬레이션을 하여 편광에 따른 도파모드 공진에 의한 특성임을 규명하였다.

비글견에서 동종혈전 색전술을 이용한 중간대뇌동맥의 허혈성 뇌경색 모델 (Ischemic Infarcion Model by Middle Cerebral Artery Occlusion using Allogenic Blood Clot in Beagle Dogs)

  • 김영환;최수영;이기자;한우석;최호정;이영원
    • 한국임상수의학회지
    • /
    • 제33권1호
    • /
    • pp.10-15
    • /
    • 2016
  • The purpose of this study was to establish reproducible ischemic infarction model using allogenic blood clot in beagle dogs and identify induced ischemic lesion after middle cerebral artery occlusion using magnetic resonance imaging (MRI) and histopathologic findings. Twenty eight male beagle dogs with no evidence of neurologic disease were experimented. Allogenic embolus was made using a healthy beagle dog. After internal carotid artery (ICA) was exposure, 16G catheter was introduced through the ICA. The dog was administered 0.3 ml blood clot for 15 seconds followed by 3 ml of saline for 15 seconds. MRI scans were performed with 1.5T to evaluate ischemic lesion at 7 days after middle cerebral artery occlusion procedure. Evaluation parameters of MRI include location, distribution, infarction type, margin, shape, mass effect and intensity of T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), fluid attenuated inversion recovery (FLAIR) sequence, diffusion weighted imaging (DWI) and apparent diffusion coefficient (ADC). On MRI, all dogs (28/28) showed focal or multifocal lesion including telencephalon and thalamus lesions, especially caudate nucleus (24/28). These lesions had well-defined margin from adjacent brain parenchyma, none or mild mass effect and various shape. Most of dogs appeared hyperintensity on T1WI, T2WI, FLAIR, and DWI/ADC, corresponding to chronic infarction. These lesions were histopathologically confirmed atrophic changes and unstained lesion. In conclusion, MRI is the useful method to provide information about ischemic infarction in dogs and the best reproducible ischemic infarction model was developed by using allogenic blood clot.

Influence of Exposure to Extremely Low Frequency Magnetic Field on Neuroendocrine Cells and Hormones in Stomach of Rats

  • Hong, Min-Eui;Yoon, Kyu-Hyun;Jung, Yoon-Yang;Lee, Tae-Jin;Park, Eon-Sub;Sohn, Uy-Dong;Jeong, Ji-Hoon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제15권3호
    • /
    • pp.137-142
    • /
    • 2011
  • Extremely low frequency magnetic fields (ELF-MF) have the ability to produce a variety of behavioral and physiological changes in animals. The stomach, as the most sensitive part of the neuroendocrine organ of the gastrointestinal tract, is crucial for the initiation of a full stress response against all harmful stress. Thus, the purpose of this study was to examine whether ELF-MF stimuli induce changes in the activity of neuroendocrine cells, considering their involvement in endocrine or paracrine effect on surrounding cells. The exposure to ELF-MF (durations of 24 h and 1 or 2 weeks, 60 Hz frequency, 0.1 mT intensity) altered the distribution and occurrence of gastrin, ghrelin and somatostatinpositive endocrine cells in the stomach of rats. The change, however, in the secretion of those hormones into blood from endocrine cells did not appear significantly with ELF-MF exposure. Comparing with sham control, ELF-MF exposure for 1 and 2 week induced an increase in $BaSO_4$ suspension propelling ratio of gastrointestinal tract, indicating that ELF-MF affects gastrointestinal motility. Our study revealed that ELF-MF exposure might influence the activity of endocrine cells, an important element of the intrinsic regulatory system in the digestive tract. The pathophysiological character of these changes and the mechanism responsible for neuroendocrine cell are still unclear and require further studies.

무지근육에서 상상의 운동과 연관된 촉진과 억제에 관한 운동 유발 전위 검사 (Motor Evoked Potentials Study of the Facilitation and Reciprocal Inhibition Induced by Motor Imagination in the Thumb Muscles)

  • 양현덕;손일홍;석승한;이성수
    • Annals of Clinical Neurophysiology
    • /
    • 제5권2호
    • /
    • pp.187-191
    • /
    • 2003
  • Purpose: MEPs elicited by transmagnetic stimulations of the motor cortex are facilitated by voluntary muscle contraction. We evaluated the effects of the imagination of the movements on latencies of MEPs and reciprocal inhibition by using transmagnetic stimulations. Methods: Twenty two healthy volunteers(eight men and fourteen women) were studied. TMSs were delivered at rest and during imagining abducting or adducting right thumb. A stimulator with a round coil and a fixed intensity of 80% of maximum was used to evoke MEPs. MEPs were evoked by magnetic stimulations over the scalp and cervical spine(C7-T1), and central motor conduction times(CMCT) were calculated by subtracting the latency of compound muscle action potentials(CMAPs) obtained by stimulating over the cervical spine from that obtained by stimulating over the scalp. The motor evoked potentials were recorded from right abductor pollicis brevis muscle(APB) and adductor pollicis muscle(AP) simultaneously. Results: Imagination of abduction resulted in a shortened latency of the CMAPs in APB, and a prolonged latency in AP. Imagination of adduction resulted in a shortened latency in AP, and a prolonged latency in APB. But the imagination caused no significant change in the latency of CMAPs elicited by stimulation over cervical spine. Therefore, the changes of the CMCTs account for these latency changes with imagination of movement. With the imagination of abduction, there are significant reduction of the CMCT's in APB(10.8%) and prolongation in AP(5.8%). On the other hand, with the imagination of adduction, prolongation of the CMCT's in APB(7.3%) and reduction in AP(5.9%) were observed. Conclusion: These findings indicate that imagination of muscle contraction increases the excitability of the human corticospinal system. Reciprocal inhibition may be accountable for the prolonged latency in the antagonist muscle.

  • PDF

유한요소법을 이용한 IH-JAR의 열확산 예측에 관한 연구 (A Study on the Heat-Diffusion Prediction of Induction Heating JAR using Finite Element Method)

  • 오홍석
    • 한국화재소방학회논문지
    • /
    • 제16권2호
    • /
    • pp.8-13
    • /
    • 2002
  • 유도가열 기술은 담금질, 단조를 위한 예열, 용융 그리고 요리 등과 같은 산업 전반에 걸쳐서 아주 폭넓게 사용되는 기술이다. 본 논문에서는 IH-JAR의 효과적인 설계를 위하여 자계 및 열 해석을 하였다. IH-lAR의 내부자계는 3차원 축대칭 유한요소법을 사용하여 해석하였으며, 열원은 IH-JAR 내부에서 유도된 와전류에 의하여 발생되고, 열은 열원과 열방정식을 사용하여 계산되어진다. 또한, IH-JAR의 온도분포를 시간과 투자율에 따라 제시하였다.