• Title/Summary/Keyword: indoor humidity

Search Result 490, Processing Time 0.029 seconds

Characteristics of Thermal Comfort in Environment Chamber for Winter

  • Kim, Kyung-Hoon;Park, Jong-Il;Song, Yong-Gil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.1
    • /
    • pp.73-83
    • /
    • 2000
  • The purpose of this study is to analyze and characterize the correlation of the thermal comfort sensation with physiological responses for men in winter indoor environment. A number of experiments were conducted under twenty different environmental conditions with college male students. Clinical information on each participant was reported in terms of electrocardiogram (ECG), electroencephalogram (EEG) and self-centered evaluation. The comfort zone in winter is found, throughout the study, at Standard New Effective Temperature (SET$T^+$) of 25.2$^{\circ}C$, Predicted Mean Vote (PMV) between 0.27 and 0.62, and Thermal Sensation Vote (TSV) in the range of -0.76 and 0.36. The largest difference in skin temperature is measured at the calf area with respect to air temperature changes. Skin sensitivity to environment temperature is explained as calf, head, chest and abdomen in descending order. Change in heat rate is analyzed to be in parallel with that of SET$T^+$.

  • PDF

A Research on the $CO_2$ Peak Point Control According to Ventilation Rate During Sleeping (취침 시 환기횟수에 따른 $CO_2$ 피크치 제어에 관한 연구)

  • Kim, Se-Hwan;Kim, Dong-Gyu;Park, Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • Ventilation requirement of apartment was mandated according to building equipment standards in 2006. When ventilation unit was considering for indoor air quality maintenance, we needed energy saving and efficiency ventilation control methods. This study carried out experiment of ventilation rate 0.7 adequacy. When we lived in apartment, we assumed that sleeping time was long stayed time in unconsciousness. Experiments carried out ventilation rate 0, 0.1, 0.4 and 0.7 in environment chamber from 22 o'clock to 06 o'clock, the concentration of $CO_2$, temperature and humidity rate measured. Analyzing the results, conclusions are as follows. 1) When we sleep in bedroom, ventilation rate 0.4 meet the requirements of domestic legal standards. Conform fan of similarity law, ventilation rate 0.4 reduced power cost about 80% than 0.7. 2) In generally sleeping time 8 hours, peak point control reduced running time of ventilation unit about 43% than normal control.

Numerical Simulation of the Thermal Environment inside an Opened Tomb (개방된 고분내부의 열 환경 수치모사)

  • Lee, Kum-Bae;Youn, Young-Muk;Jun, Hee-Ho;Park, Jin-Yang;Ko, Seok-Bo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.872-878
    • /
    • 2006
  • In recent years the importance of the preservation of cultural artefacts like ancient tombs has been widely accepted domestically and internationally as the quality of life improves. However not much technical attention has been paid for the facilities and systems to preserve those artefacts. Even the general understanding of the preservatory environment of the underground space as tombs is poor. As a part of the present study, the temperature and relative humidity inside a selected artefact, Shinkwan-ri tomb, have been monitored for a year round by the present author to improve the understanding of the indoor thermal environment, is pursued to provide a predictive tool of numerical modelling of Shinkwan-ri tomb the opened underground space thermal environment. In this study, predictive numerical modelling of Shinkwan-ri tomb using the Computational Fluid Dynamics, calculate the velocity and temperature distribution and offer basic data which are necessary for the best fitted design of tomb air-conditioning device.

  • PDF

Development of a System-Independent Mobile Smart Shelter using Solar Energy (태양광 에너지를 이용한 계통 독립형 이동식 스마트 쉼터 개발)

  • Joo, Jong-Yul;Lee, Young-Jae;Park, Kyoung-Wook;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1061-1068
    • /
    • 2020
  • This paper presents a system-independent mobile smart shelter using solar energy technology that can be freely installed in various places, such as parks, countryside, event area, construction area and walking tour places where the system power are difficult to use. The proposed smart shelter is equipped with solar power generation and energy storage devices that is combined with IoT technology to collect indoor and outdoor humidity, fine dust and tourist awareness in real time. It is possible to efficiently manage energy by performing the optimal energy operation during the heat- wave, cold-wave situation and the presence of travelers and it is possible to serve as a shelter for as long as possible without system power.

Fungal Distribution of the Janggyeong Panjeon, the Depositories for the Tripitaka Koreana Woodblocks in the Haeinsa Temple

  • Hong, Jin Young;Kim, Young Hee;Lee, Jeong Min;Kim, Soo Ji;Park, Ji Hee
    • Journal of Conservation Science
    • /
    • v.38 no.1
    • /
    • pp.64-71
    • /
    • 2022
  • Many investigations have been conducted on the biological damage and environmental conditions necessary to preserve the Janggyeong Panjeon and Daejanggyeongpan (woodblocks). We performed a survey on the concentration and diversity of airborne fungi in the Janggyeong Panjeon and compared them with the results of a survey from 2012. The temperature of the Beopbojeon building was slightly lower, while the relative humidity was higher than those found at the Sudarajang building. The concentration of airborne fungi in the Beopbojeon was 1.44-fold that of the Sudarajang. It was confirmed that the concentration and diversity of airborne fungi in the Janggyeong Panjeon differed depending on the sampling site. In total, 23 fungal genera were identified from the air samples, and 11 fungal and 1 bacterial genera were identified from the surface of the woodblocks. Among these, only five types of fungi were commonly distributed in the indoor air and surface of the Daejanggyeongpan; however, 58.3% of the fungi identified on the surface of the woodblocks were not observed in the in the air samples. The surface-dwelling fungi may accumulate dust to form microbial communities over time.

Design an Automatic System to Control and Monitor the Process of Straw Mushrooms Indoors Cultivation

  • Quoc Cuong Nguyen;Quoc Huy Nguyen;Jaesang Cha
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.59-67
    • /
    • 2024
  • Current straw mushroom farming in countries with large rice growing areas has great development potential, and was once considered a way to generate additional income and reduce poverty in rural areas. However, currently most people still grow mushrooms using traditional processes, leading to low productivity and unguaranteed output quality. Currently, due to climate change and unusual weather changes, people tend to switch to growing straw mushrooms indoors. In the process of growing straw mushrooms indoors, the design of an automatic control and monitoring system is very important to ensure the growing process is carried out effectively and achieves high yields. In this paper, we propose a system that can automatically control and monitor the humidity and temperature of the indoor straw mushroom growing process and other parameters that can be monitored through a network system using Internet of Things. The control algorithm automatically adjusts the grow house equipment based on feedback from sensors to maintain an optimal environment for growing straw mushrooms. Experimental results show that the straw mushroom growing system with automatically controlled and monitored environmental parameters helps improve efficiency, reduce costs and increase the sustainability of the current straw mushroom growing industry.

Plant Physiological Responses in Relation to Temperature, Light Intensity, and CO2 Concentration for the Selection of Efficient Foliage Plants on the Improvement of Indoor Environment (실내 환경 개선에 적합한 식물 선발을 위한 온도, 광도, 이산화탄소 농도에 따른 관엽식물들의 생리적 반응)

  • Park, Sin-Ae;Kim, Min-Gi;Yoo, Mung-Hwa;Oh, Myung-Min;Son, Ki-Cheol
    • Horticultural Science & Technology
    • /
    • v.28 no.6
    • /
    • pp.928-936
    • /
    • 2010
  • This study was conducted to select efficient foliage plants for improving indoor environment conditions through the investigation of physiological responses including photosynthetic rate according to temperature, light intensity, and $CO_2$ level. Eight popular foliage plants used in this study were $Hedera$ $helix$ L., $Cissus$ $rhombifolia$ Vahl, $Ficus$ $benjamina$ L. 'Hawaii', $Syngonium$ $podophyllum$ Schott 'Albo-Virens', $Dieffenbachia$ $sp.$ 'Marrianne', $Pachira$ $aquatica$ Aubl., $Spathiphyllum$ $wallisii$ Regel, and $Scindapsus$ $aureus$ Engler. Photosynthetic rate and transpiration rate of the plants subjected to various light intensities (0, 25, 50, 75, 100, 150, 300, and $600{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD), $CO_2$ levels (0, 50, 100, 200, 400, 700, and $1,000{\mu}molCO_2{\cdot}mol^{-1}$), and two different temperatures (16 and $22^{\circ}C$) were measured. In addition, various parameters in relation to photosynthesis were calculated from the measured data. As a result, the patterns of photosynthesis varied among 8 foliage plants according to light intensity, $CO_2$ level, and temperature. Most foliage plants except $Dieffenbachia$ had high levels of apparent quantum yield, which represents the photosynthetic rate under low light intensity (PPFD $0-100{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$). $Hedera$ $helix$, $Ficus$ $benjamina$, $Pachira$ $aquatica$, and $Spathiphyllum$ $wallisii$ exposed to high light intensity (PPFD $200-600{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) showed high levels of photosynthesis. $Cissus$ $rhombifolia$ and $Syngonium$ $podophyllum$ were low in $CO_2$ fixation efficiency compared to the other 6 foliage indoor plants. $Hedera$ $helix$ and $Spathiphyllum$ $wallisii$ showed high photosynthetic rate under high $CO_2$ level and vigorous photosynthesis was also observed in $Ficus$ $benjamina$ and $Pachira$ $aquatica$ grown under $22^{\circ}C$. Considering characteristics of indoor environment such as low light, high $CO_2$ level, and low relative humidity, therefore, $Hedera$ $helix$, $Spathiphyllum$ $wallisii$, $Ficus$ $benjamina$, and $Pachira$ $aquatica$ were efficient indoor foliage plants to improve indoor environmental conditions.

Stabilizing Soil Moisture and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System Controlled by Humidifying Cycle (가습 주기에 따른 벽면형 식물바이오필터의 토양 수분 안정화 및 실내공기질 정화)

  • Lee, Chang Hee;Choi, Bom;Chun, Man Young
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.605-617
    • /
    • 2015
  • The ultimate goal of this research is to develop a botanical biofiltration system that combines a green interior, biofiltering, and automatic irrigation to purify indoor air pollutants according to indoor space and the size of biofilter. This study was performed to compare the stability of air flow characteristics and removal efficiency (RE) of fine dust within a wall-typed (vertical) botanical biofilter depending on humidifying cycle and to investigate RE of volatile organic compounds (VOCs) by the biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be suitable for indoor space utilization. As a result, relative humidity, air temperature, and soil moisture content (SMC) within the biofilter showed stable values regardless of three different humidifying cycles operated by the metering pump. In particular, SMCs were consistently maintained in the range of 27.1-29.7% during all humidifying cycles; moreover, a humidifying cycle of operating for 15 min and pausing for 45 min showed the best horizontal linear regression (y = 0.0008x + 29.09) on SMC ($29.0{\pm}0.2%$) during 120 hour. REs for number of fine dust (PM10) and ultra-fine dust (PM2.5) particles passed through the biofilter were in the range of 82.7-89.7% and 65.4-73.0%, respectively. RE for weight of PM10 passed through the biofilter was in the range of 58.1-78.9%, depending on humidifying cycle. REs of xylene, ethyl benzene, total VOCs (TVOCs), and toluene passed through the biofilter were in the range of 71.3-75.5%, while REs of benzene and formaldehyde (HCHO) passed through the biofilter were 39.7% and 44.9%, respectively. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was very effective for indoor air purification.

Study on the Indoor Environment and Status of Facilities and Equipments of Home Economics Practice Rooms of Middle Schools in Jeju Special Self-Governing Province (제주특별자치도 중학교 가정실의 실내환경 및 시설.설비 현황에 관한 연구)

  • Park, Min-Hye;Kim, Bong-Ae
    • Journal of Korean Home Economics Education Association
    • /
    • v.19 no.3
    • /
    • pp.61-76
    • /
    • 2007
  • The purpose of the study is to identify and understand problems existing in the middle school home economics practice rooms in Jeju Special Self-Governing Province. The findings are based on the examination and the analysis of the indoor environment and the condition of the facilities and equipment. Study method employs on-site research and a survey. The on-site research was conducted about temperature, humidity, intensity of illumination, and status of teaching instrument in 10 out of 41 middle schools in Jeju Special Self-Governing Province from August 16 to September 30, 2006. Meanwhile, the survey was implemented by mail for 95 teachers in charge of manual training and home economics education in 41 middle schools in Jeju from November 1 to 23, 2005. 64 questionnaires out of total 95 were collected, including those collected during the period of on-site research. Finally, 61 questionnaires which were effective among the answered ones were used for analysis. Collected materials were analyzed with the SPSS Win.12.0 program for frequency, percentile analysis. In conclusion, the study determines that the condition of the home economics practice rooms of the middle school in JSSGP in terms of temperature, humidity, lighting and ventilation is very inadequate. The structure of the practice room represents an inefficient work flow pattern. Further, the facilities and equipment are in a very poor condition because the facilities are old and the retention rate of teaching tools is low. Therefore, to address these problems, the study suggests that improvements on the facilities and equipment should be made and teaching tools should be replenished in accordance with the industry standard.

  • PDF

Clothing Microclimate and Subjective Sensations by Wearing Long Johns in Mildly Cold Air (겨울철 실내 온도에서 내복 착용에 따른 의복 기후와 주관적 감각)

  • Kim Myung-Ju;Lee Joo-Young
    • Journal of the Korean Home Economics Association
    • /
    • v.42 no.10 s.200
    • /
    • pp.91-104
    • /
    • 2004
  • The purpose of this study was to examine the differences of clothing microclimates and the subjective sensations according to age, gender and clothing weight for $19^{\circ}C$ air temperature. This study was done to gain fundamental data related to saving heating energy and to improve health through wearing underwear (long johns) in lower indoor temperatures. The subjects were divided into four groups (6 young males, 5 young females, 6 old males, 6 old females), and our experiment consisted of three conditions; the first condition was wearing long underwear in $19^{\circ}C$ air (19CUW condition); the second condition was without wearing long underwear in $19^{\circ}C$ air (19C condition); and the third condition was without wearing underwear in $24^{\circ}C$ air (24C condition). The experiment showed that the clothing microclimate temperature and humidity was the lowest in the 19C condition and the highest in the 24C condition irrespective of age and gender. The clothing microclimate in the 19CUW condition was not significantly distinguishable from the other conditions. Clothing microclimate temperature and humidity when the subjects responded thermal comfort was $28\~34^{\circ}C$ and $15\~40\%$RH without any significant difference according to age and gender. For the thermal sensation, the 24C condition was regarded as the warmest environment by the four groups, and the next preference was the 19CUW condition (p<0.001). Young females and old males showed a tendency to feel colder than young males and old females. For the thermal sensation of hands and feet, the young groups felt the warmest in the 24C condition and the coolest in the 19 C condition (p<0.001). However, old males felt neutral for the foot thermal sensation without any significant difference between the three conditions. Old females felt neutral for both the hands and feet thermal sensations without any significant difference between the three conditions. Thermal preference was the highest in the 24C condition for the 4 groups. In the 19CUW condition, for the thermal preference, most young males and females responded 'No change'; on the other hand, mea of the old responded 'Warmer'(p<0.001). It was the 24C condition that the 4 subject groups felt the most thermally comfortable. In the 19CUW condition, over $80\%$ of responses of each group expressed satisfaction and in the 19C condition, over $80\%$ of responses of each group, except young females, expressed satisfaction. In conclusion, in view of the clothing microclimate and subjective sensations, the 24C condition was the condition that gave subjects the least cold stress and the best subjective preference. However, the 19C condition and the 19CUW condition was not such a cold stress as to give healthy subjects a thermal burden.