• Title/Summary/Keyword: indoor air pollutant

Search Result 125, Processing Time 0.029 seconds

Characteristics of Formaldehyde Concentrations in the Underground Spaces in Gyungnam Province (경남지역 지하생활공간 중 미량 유해물질인 포름알데히드의 농도 분포 특성)

  • Ha Kwon Chul
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.353-357
    • /
    • 2004
  • The purpose of this research is to characterize formaldehyde as trace toxic air pollutant in the underground spaces in Gyungnam province. Air samples of formaldehyde were taken in the three underground spaces for ten months from April 2003 to January 2004. The IAQ(Indoor Air Quality) of underground spaces were controled using central ventilation(supply/exhaust) system. The levels of GM of airborne formaldehyde concentrations in three sampling spaces were well below applicable standards, Korean Ministry of Environment, 0.1 ppm. However, some sample of airborne formaldehyde concentrations in underground spaces 'B' and 'C' were in excess of standard, due to the commercial products in shop, structural material, and the climate having high humidity and temperature. There are statistical differences in levels of formaldehyde by sampling spaces (p=0.086).

A Study on the Emission Characteristics of Gaseous Organic Contaminants from Building Materials and Newly Constructed Apartments (신축 공동주택 및 건축자재에서의 오염물질 방출 특성)

  • Kim Yun-Deok;Lee Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.563-570
    • /
    • 2006
  • We investigated the emission characteristics of gaseous organic contaminants from building materials and newly constructed apartments. The emission test for building materials was done with small chamber method, and field measurements in newly constructed apartment were carried out by Korea Standard Test Method for Indoor Air Quality. First, the emission test by small chamber showed that the TVOC emission from building materials was much higher than formaldehyde. On the other hand, as expected, considerably high concentration of both TVOC and HCHO was detected in the new apartment.

A Study of Indoor Air Quality of Public Facilities in Chung-Nam Area (충남지역 미적용 다중이용시설의 실내공기질에 관한 연구)

  • Hong, Sung-Chul;Jou, Hye-Mee;Cho, Tae-Jin;Lee, Che-Won;Jung, Yong-Taek;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.2
    • /
    • pp.35-45
    • /
    • 2008
  • In order to recommend criteria for the administration law on indoor air quality, this study was conducted to examine the distribution and the concentration of indoor air pollutants ($PM_{10},\;CO_2$, CO, HCHO, TBC, $NO_2$, Rn, VOCs, asbestos, $O_3$) in public facilities in the Chung-Nam area. The concentrations of indoor air pollutants were obtained from sixty seven public facilities such as a cinema, an office, a restaurant, a theater and an academy. This study was performed from August to December, 2005. The results of this study showed that the concentrations of indoor air pollutants such as $PM_{10},\;CO_2$, CO, HCHO, TBC, Rn and $O_3$ were less than the recommended limits. However, the average concentration of VOCs was $521.73{\mu}g/m^3$ (GM : $221.69{\mu}g/m^3$), which was higher than the recommended limit of $400{\mu}g/m^3$. Moreover, the average concentration of $NO_2$ was 345.66ppb (GM : 69.95ppb), which was higher than the recommended limit of 50 ppb. The correlation between the concentrations of indoor air pollutants and the type of facilities with respect to $CO_2$, TBC and Rn was statistically low (p<0.05). However, the correlation was high in terms of the CO and $O_3$ concentrations (p<0.01). No relationship between the indoor air pollutants and the type of facilities was observed for $PM_{10}$, VOCs and $NO_2$. The year of construction was compared to the concentrations of indoor air pollutants. Specifically, when the construction date was less than 3 years, the HCHO, VOCs and TBC concentrations were $44.75{\mu}g/m^3,\;555.07{\mu}g/m^3$ and $337.79CFU/m^3$, respectively. These concentrations were $120{\mu}g/m^3$ and $211.84CFU/m^3$ higher for VOCs and TBC than the concentrations obtained from the facilities more than 3 years. However, the concentration of HCHO was similar between the facilities older and younger than 3 years of age. Year, temperature, humidity and indoor air pollutant correlation analyses showed that temperature and humidity, temperature and TBC, temperature and $O_3,\;PM_{10}$ and $NO_2$, HCHO and VOCs, $CO_2$ and Rn had positive relationships. However temperature and Rn, humidity and $CO_2,\;CO_2$ and $O_3,\;O_3$ and Rn had negative relationships. Accordingly, it will be necessary to manage the factors affecting indoor air quality so that the residents can have a more comfortable and healthier living environment. Ultimately, the results of this study are expected to be utilized as baseline data.

A Study on the Increasement of the Indoor Amenity on the New Apartment (신축아파트의 실내거주환경개선에 관한 연구)

  • Kang Hyun-Su;Kim Sung-woong;Cho Young-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.163-166
    • /
    • 2005
  • Amenity is an essential factor of Modern Apartment. But because of many chemical products and noxious volatile organic compound(VOC) used in the apartment, many people are exposed to them. This fact implies that there can be many disease caused by them. Therefore to reduce pollutant matters inducing sick house syndrom, measures for new furniture and apartment dweller were suggested in this study.

  • PDF

Consideration of Ozone Removal and Control in Built Environment by Building Materials (건축자재에 의한 실내 오존제거 및 제어에 대한 고찰)

  • Chung, Ok-Young;Jeong, Su-Gwang;Kim, Jun-Hyun;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.467-475
    • /
    • 2012
  • Recently, residents have been spending almost 90% of their time indoors, which presents a higher risk from inhalation of pollutants than when spending time outdoors. Therefore, controlling indoor air quality became important. It is reported that the lung diseases and mortality for occupants are increased when there is high density of ozone which is one of the pollutants among the indoor air. In addition, the reactions between ozone and building materials produce VOCs and formaldehyde. The studies to eliminate the ozone by building materials have been actively investigated. However, ozone removal and secondary pollutants from ozone reactions with building materials have not been reported in Korea. For this reason, the aim of this study is to introduce ozone removal by HVAC filters, various building materials, and eco-friendly building materials including the quantity of secondary pollutant emissions.

A Finish Material Management Process for Indoor Air Quality -Focused on Apartment Buildings- (실내 공기질을 고려한 마감자재 선정 프로세스 연구 -공동주택을 중심으로-)

  • Kwon, Gi-Deoc;Lee, Dong-Hoon;Lee, Sung-Ho;Zheng, Qi;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.123-130
    • /
    • 2010
  • Indoor air quality has attracted great attention in recent years and thus the importance of managing finishing materials in terms of pollutant source control is being emphasized. Managing the finishing material at the design stage maximizes the efficiency of IAQ control at the following construction stage. However, there are insufficient investigations on the application of a specific finishing material management process, a database management system or a finishing material management process network. As a result, the main purposes of this study comprise comprehensive evaluation of IAQ performance from the selected finishing materials and auxiliary materials, application of the material management system basing on the types and characteristics of toxic substances generated from the indoor finishing materials, investigation of IAQ evaluation standard, and the overall IAQ evaluation method for the design parts. The result of this study will be the basic data to construct DBMS for management of finishing materials with respect to IAQ.

The Evaluation of Air Quality in Educational Child Care Centers (영유아 교육시설에서의 실내공기질 평가)

  • Lim, Ji-Hye;Pang, Seung-Ki;Shon, Jang-Yeul
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • It is indispensable for child care centers to investigate and manage indoor air quality (IAQ) because they perform education and day care for children who usually have weak immunity. Nevertheless, there is insufficient research being done, given its importance. This study aims to investigate indoor pollutants' concentration and to seek the causes in order to improve the air quality conditions. Also it aims to secure data which can be used for further researches. Measurements were performed for air temperature, relative humidity, carbon dioxide, carbon monoxide, fine particle mass, formaldehyde and volatile organic compounds. Temperature, humidity, CO and CO2 were measured 30times(1min/time) and PM10 was measured 10times (3min/time). Formaldehyde and volatile organic compounds were measured and analyzed based on The Indoor Air Quality Official Test Method. The results show that the temperatures were within the comfort zone in over half of the centers. CO2 was found to be the main pollutants as its concentration exceeded the IAQ standard. The concentrations of TVOC and PM10 exceeded the standard, by 32% and 24% respectively, whereas those of HCHO and CO were under the standard. HCHO and CO concentrations were under the guideline. 24% of child care centers for education were found to exceed the standard in 2 or more of the pollutants. 82% of were found to exceed the standard by 1 or more. Therefor it is requested for IAQ to manage and improve in child care center for education.

Quantitative Analysis of CO2 Reduction by Door-opening in the Subway Cabin (출입문 개폐에 의한 전동차 객실 CO2 저감효과 분석)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.153-161
    • /
    • 2008
  • The guidelines for indoor air quality of public transportations such as subway, train and bus was presented by Korean Ministry of Environment last end of year 2006 based on the great consequence of indoor air quality in daily life. Two main parameters, carbon dioxide($CO_2$) and particulate matters smaller than $10\;{\mu}m(PM_{10})$, were selected as index pollutants for the management of indoor air quality. The former pollutant, $CO_2$, is regarded as index of ventilation status and the major source of $CO_2$ in the train or subway is the exhalation of passengers. It is publically perceived that the high $CO_2$ concentration in a crowded subway will be reduced and ventilated with outdoor air by door-opening taken every 2 or 3 minutes when the train stops each station. However, there has not been any scientific proof and quantitative information on the effect of door-opening on the $CO_2$ reduction by ventilation with outdoor air. In this study, $CO_2$ concentration and number of passengers were measured at each station on the 3 lines of Korail metropolitan subway. In order to evaluate the effect of $CO_2$ reduction by door opening, the theoretical approach using the $CO_2$ balance equation was performed. By comparing the predicted data with monitoring one, the optimum $CO_2$ dilution factor was determined. For the first time, it was quantified that about 35% of $CO_2$ concentration in the subway indoor was removed by the door-opening at each station.

A Study on Improving Ventilation Performance in High-rise Residential Building by Natural Ventilation System (자연환기 시스템을 이용한 고층 공동주택의 환기성능 향상에 관한 연구)

  • Choi, Taehwoan;Kim, Yu-Mi;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.51-56
    • /
    • 2007
  • This study focuses on developing natural ventilation system which is able to satisfy the good indoor air quality and air speed. The natural ventilation system developed in this study is for double window façade and it has two operation modes for summer and winter. Operational sections of the devices have been analyzed by CFD simulation to calculate discharge coefficients of openings and estimated indoor air speed. For the analysis of the appropriate installation area ratio for each room and the optimum installation area, TRNFLOW simulation has been used. As the results, we could see that the natural ventilation system can provide the similar pollutant removal performance to 0.7 ACH of mechanical ventilation with appropriate installation area and installation area ratio.

An Investigation of Citizen's Attitude on the Harmful Insects in House (주택에서의 유해생물에 대한 시민 인식도 조사)

  • 김영환;손종렬;문경환;변상훈
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.36-40
    • /
    • 2002
  • The purpose of study was to suggest an investigation of citizen's attitude on harmful insects in house. This study was consisted of four parts, such as basic investigation (housing shape, housing material, the period of house constructed, a cleaning condition), condition of kitchen, condition of living room condition of bathroom. The environmental pollution was increased by the development of industry and urbanization in modern. And also the clean of house has related with air quality such as pollutants and harmful insects etc. Because dwelling shape of urban come to be crowded, shut tightly and high buildings, the air quality of indoor was gradually polluted by several irregular cause. In one of housing pollution, the harmful insects was important any other than indoor air pollution. The problems of kitchen were the odor of food waste, discharge system of sewage and harmful insects. The important issues of living room were mold and construction materials, then important them of bathroom were easing nature and discharge system of sewage. A kind of the harmful insects in house investigated cockroach> mosquito> ant>fly. Finally, it appeared that the control of harmful insects can be applied to the improvement of indoor air pollutant which are difficult to be controlled in house.