• 제목/요약/키워드: indoor aerosol particle

검색결과 48건 처리시간 0.022초

비말 가림막과 휴대형 공기청정기 사용에 의한 대화 중 비말 및 공기전파 저감 효과 (Effectiveness of droplet protective screens and portable air purifiers against droplet and airborne transmission during conversation)

  • 허지은;신동호;조희주;박현설;조윤행
    • 한국입자에어로졸학회지
    • /
    • 제18권4호
    • /
    • pp.87-95
    • /
    • 2022
  • Currently, droplet protective screens (DPSs) are used to prevent the spread of respiratory diseases. As virus particles can maintain their infective in indoor environments, recent studies have investigated the risk of airborne transmission. However, the ability of DPSs to block airborne transmission has not been verified yet. In this study, the preventive ability of DPSs against droplet and airborne transmission was evaluated. Moreover, the effectiveness of a Portable air purifier (PAP) was investigated. According to results, in a simulated room where an infectious person spoke, the DPS blocked more than 90% of the micron-sized droplets (with a diameter larger than 1 ㎛) transmitted to the front of the infectious person. However, sub-micron droplets (with a diameter smaller than 1 ㎛) passed through the DPS and spread in a room. However, the PAP reduced the amount of both micron and sub-micron droplets transmitted to the front of the infectious person. When the PAP airflow direction was set from the DPS surface to the free space near the infectious person, improved prevention against droplet and airborne transmission was recorded. However, airborne transmission was accelerated when the PAP airflow direction was set from the free space to the DPS surface.

온도와 광도가 톨루엔-NOx-공기 혼합물의 광산화 반응에 미치는 영향의 비교 (Comparison of Temperature and Light Intensity Effects on the Photooxidation of Toluene-NOx-Air Mixture)

  • 주옥정;배귀남;최지은;이승복;김영성;문길주;윤순창
    • 한국대기환경학회지
    • /
    • 제23권3호
    • /
    • pp.353-363
    • /
    • 2007
  • To differentiate temperature effect from the light intensity effect on the formation of secondary products during the photooxidation of toluene-$NO_x$-air mixtures, steady-state air temperature was changed from $20^{\circ}C\;to\;33^{\circ}C$ at the same light intensity of $0.39min^{-1}$ in an indoor smog chamber. Smog chamber consisted of 64 blacklights and a $5.8m^3$ reaction bag made of Teflon film. Air temperature was controlled by an air-conditioning system. The starting time for rapid conversion of NO to $NO_2$ was slightly delayed with decreasing air temperature. In contrast to light intensity effect, the ozone formation time and the ozone production rate were insensitive to air temperature. Although the formation time for secondary organic aerosols was not changed, the particle number concentration increased with temperature. However, the newly formed secondary organic aerosol mass at lower temperature was higher than that at higher temperature. Since light intensity significantly affected the starting time and quantity of ozone and aerosol formation, it is considered that the temperature could contribute partly the quantity of aerosol formation during the photooxidation of toluene-$NO_x$-air mixtures.

Shadowgraph 가시화 기법을 활용한 정전분무액적의 크기 측정 (Size measurement of electrosprayed droplets using shadowgraph visualization method)

  • 오민정;김성현;이명화
    • 한국입자에어로졸학회지
    • /
    • 제13권4호
    • /
    • pp.151-158
    • /
    • 2017
  • 실내 환경 및 산업체 배기가스중의 미세먼지를 제거하는 방법으로서 압력손실이 낮으면서도 집진효율이 높은 전기집진기가 널리 사용되어지고 있다. 그러나 전기집진기는 서브마이크로미터 크기의 먼지에 대한 제거효율이 낮기 때문에, 정전분무법으로 하전액적을 공급하여 먼지와의 충돌을 촉진시켜 하전효율을 높이는 방법이 대안으로 떠오르고 있다. 그러나 먼지의 하전효율은 정전분무된 액적의 크기 및 개수와 밀접한 관계가 있으나, 액적의 크기를 효과적으로 측정하는 방법이 확립되어 있지 않은 것이 현실이다. 본 연구에서는 손쉽게 이용할 수 있는 수돗물로 정전분무를 한 후, 분무된 액적을 다양한 방법으로 가시화하여 고속카메라로 촬영하였다. 그리고 Image J 프로그램으로 액적의 크기분포를 측정하여 가시화방법에 따른 액적의 크기를 상호 비교하였다. 결과적으로, 레이저로 가시화하여 고속카메라로 촬영하면 미세액적의 이미지화가 가능하기 때문에, 그 액적의 크기는 Xenon광으로 가시화하여 측정한 것보다 약 50 % 작음을 알 수 있었다. 또한 레이저로 가시화하여 측정한 액적의 크기가 $Fern{\acute{a}}ndez$ de la Mora and Loscertales (1994)의 예측치와 비교적 잘 일치함을 알 수 있었다.

지하역사 승강장 공조 시스템 필터용 항바이러스 코팅 성능 및 재생 성능 평가 (Development of Optimal Antiviral Coating Method for the Air Filtration System of Subway Station)

  • 박대훈;황정호;신동호;김영훈;이건희;박인용;김상복;홍기정;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권1호
    • /
    • pp.9-21
    • /
    • 2022
  • In this study, a novel antiviral coating method for the air filtration system of subway station was investigated. Using dry aerosol coating process, we developed a high-performance antiviral air filter with spark discharger and carbon brush type ionizer. Silver nanoparticles were produced by a spark discharge generation system with ion injection system and were used as antiviral agents coated onto a medium grade air filter. The pressure drop, filtration efficiency, and antiviral ability of the filter against aerosolized MS2 virus particles as a surrogate of SARS-CoV-2 virus were tested with dust contamination. Dust contamination caused the increase of the filtration efficiency and pressure drop, while the antiviral agents (in this study, silver nanoparticles) coating did not have any significant effect on the filtration efficiency and pressure drop. Using these properties, we suggested a novel method to maximize the antiviral performance of the antiviral air filter that was contaminated by dust particles. Moreover theoretical analysis of antiviral ability with dust contamination and re-coated antiviral agents was carried out using a mathematical model to calculate the time-dependent antiviral effect of the filter under actual conditions of subway station. Our model can be used to apply on antiviral air filtration system of subway station for prevention of pandemic diffusion, and predict the life cycle of an antiviral filter.

지하역사 승강장에서 코로나19 바이러스 공기감염 대응 공기조화기와 공기청정기의 적용 효과 비교 (Comparison of applicability of HVAC and air cleaners in a subway station platform against airborne infection of SARS-CoV-2)

  • 이건희;김상복;박인용;홍기정;이예완;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권3호
    • /
    • pp.51-59
    • /
    • 2022
  • In this work, virion concentration and its dose changes by HVAC and air cleaners were estimated in a subway station platform to control airborne infection of SARS-CoV-2. Collection efficiencies with particle size were measured for the air filter equipped in a HVAC in one subway station in Daejeon. Indoor PM2.5 changes according to outdoor PM2.5 with time were also measured to estimate air infiltration rate in the subway station platform. When infected persons generate virions by 104, 105, 106, 3 × 106 and 5 × 106 h-1 in a 2,400 m3 volume platform, the concentration and dose were estimated as 9, 92, 275 and 458 virions/m3 and 4, 43, 130 and 217 virions after 1 hour exposure, respectively. The concentration and dose were reduced by 70%, and 64%, respectively by operations of both HVAC (with a flow rate of 16,000 m3/h, MERV 11) and ten air cleaners(with total CADR 10,740 m3/h) compared to those without operation of both HVAC and air cleaners. However, virion dose in the platform was estimated to be too low at the general conditions due to a large space, a high air infiltration (3 h-1) and a short residence time (usually < 10 mins) in the platform irrespective of the operations of HVAC or air cleaners. HVAC with filters and air cleaners would be more necessary in the concourse or shopping areas in the subway stations to reduce the infection dose from a few hundred to several tens virions in a hour.

서울 초등학교 교실의 PM2.5 및 PM10 제거를 위한 학교용 공기청정기 실증 (Field tests of indoor air cleaners for removal of PM2.5 and PM10 in elementary school's classrooms in Seoul, Korea)

  • 한방우;홍기정;신동호;김학준;김용진;김상복;김상우;황청하;노광철
    • 한국입자에어로졸학회지
    • /
    • 제15권2호
    • /
    • pp.79-90
    • /
    • 2019
  • It is important to control fine particles in children care centers, elementary schools, elderly care facilities and so on where vulnerable children and the aged stay during most of their time. This study has investigated $PM_{2.5}$ and $PM_{10}$ concentrations in two classrooms equipped with an air cleaner and two air cleaners, respectively and they were compared to those in a classroom without an air cleaner as well as those outdoors. Eight air cleaners which have various clean air delivery rates (CADRs) between 9.9 and $21.3m^3/min$ were tested in classrooms in two elementary schools in Seoul. Average $PM_{2.5}$ and $PM_{10}$ were $7.3{\pm}0.7$ and $45.5{\pm}4.1{\mu}g/m^3$ in classrooms equipped with an air cleaner and $4.2{\pm}0.6$ and $24.6{\pm}2.5{\mu}g/m^3$ in classrooms with two air cleaners, whereas they were $22.1{\pm}2.6$ and $109.1{\pm}9.6{\mu}g/m^3$ in classrooms without an air cleaner and $36.9{\pm}5.1$ and $74.1{\pm}10.6{\mu}g/m^3$ outdoors, respectively. $PM_{2.5}$ in classrooms could be reduced effectively by using an air cleaner or two air cleaners, because $PM_{2.5}$ was mainly infiltrated from outdoors, however $PM_{10}$ could not because $PM_{10}$ was mainly caused indoors by students' activities. Air cleaners were more effective for removal of $PM_{2.5}$ and $PM_{10}$ in classrooms with a high airtightness than those in classrooms with a relatively low one. Average $CO_2$ in classrooms was about 1500 to 2000 ppm for class hours dependent on the student number per a classroom, which was about 1.5 to 2 times higher than the standard, regardless of the use of air cleaner.

서울시 대중교통 내 SARS-CoV-2 RNA와 PM-2.5 오염도 실증연구 (Investigation on the SARS-CoV-2 RNA and PM-2.5 inside Public Transportations in Seoul)

  • 서민정;홍주희;이호준;박진솔;임학명;박명규;민병철;박은선;이상훈;김한준;하광태;권승미;신진호;이재인;황영옥;오영희;신용승
    • 한국입자에어로졸학회지
    • /
    • 제18권2호
    • /
    • pp.23-35
    • /
    • 2022
  • Recently, passengers using public transport are concerned about the effects of COVID-19 and fine dust. Therefore, from February 2020 to February 2021, we investigated whether SARS-CoV-2 RNA was detected even after disinfection in 55 public transportation places visited by confirmed patients in Seoul. 34 air samples and 702 object surface samples were collected and tested with RT-PCR, one surface sample was positive. In addition, preemptive investigations were conducted in 22 subway trains that passengers were being on board at that time. 1,018 preemptive tests were performed, and all were negative. Although PM-2.5 is dangerous in itself, it can be a potential carrier of viruses. It seemed that a solution was needed as one line continuously exceeded the criteria of PM-2.5. Through this study, it is judged that cluster infection in public transportation can be prevented if efforts to reduce the concentration of fine dust, appropriate disinfection management, and personal disinfection such as wearing a mask in public transportations.

도시철도 차량 하부의 풍속 및 미세먼지 농도 특징 (Characteristics of Wind Speed and PM10 Concentration underneath Railway Trains)

  • 김종범;우상희;장홍량;최진원;황문세;박형구;윤화현;정준식;배귀남
    • 한국철도학회논문집
    • /
    • 제20권1호
    • /
    • pp.11-19
    • /
    • 2017
  • 도시철도 차량의 운행은 터널 공기를 오염시키는 주된 원인이므로, 마모입자를 제거하는데 집진장치가 유용한 수단이 될 수 있다. 차량의 하부에 장착될 수 있는 집진장치의 설계조건을 파악하기 위하여 3차원 초음파 풍속계와 입자측정기를 사용하여 차량 하부의 풍속과 입자농도를 조사하였다. 2015년 2월 10일 수도권 지하철 5호선에서 운행되는 차량을 대상으로 측정하였다. 측정자료는 역 사이 노선의 형상(직선, 곡선)과 차량 속도패턴(가속, 정속 및 감속)을 구분하여 분석하였다. 차량속도도 함께 분석하였다. 직선 및 곡선 구간 모두 차량 하부의 평균 풍속은 차량속도의 약 30%이었고, 미세먼지($PM_{10}$) 농도는 약 $200{\mu}g/m^3$이었다. 감속구간에서 평균 $PM_{10}$ 농도는 가속구간에 비해 더 높았다.