• Title/Summary/Keyword: indoor/outdoor ratio

Search Result 109, Processing Time 0.019 seconds

Investigation on the Performance of Special Purpose Automotive Air-Conditioning System Using Dual Refrigeration Cycle (듀얼 냉동사이클을 이용하는 특수목적 자동차용 에어컨 시스템의 냉방성능에 관한 연구)

  • Seo, Jae-Hyeong;Bang, You-Ma;Lee, Moo-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.4
    • /
    • pp.213-220
    • /
    • 2016
  • The objective of this study is to investigate the cooling performance of an air-conditioning system for a special purpose vehicle under tropical and severe weather conditions. In order to evaluate and compare the cooling performances, the dual refrigeration cycle using R-134a was tested on a special purpose vehicle with various refrigerant charge amounts and indoor temperatures. The cycle was tested considering indoor cooling speed and compression ratio (discharge pressure), and was optimized at the refrigerant charge amount of 1.5 kg and outdoor temperature of $40.0^{\circ}C$. The time to reach indoor temperature of $15.0^{\circ}C$ increased by 86.5% and 38.1%, at the indoor temperatures from $25.0^{\circ}C$ to $32.5^{\circ}C$ and from $32.5^{\circ}C$ to $40.0^{\circ}C$, respectively. In addition, with the increase in indoor temperature from $25.0^{\circ}C$ to $40.0^{\circ}C$, the cooling capacity increased by 7.3%, from 19.1 kW to 20.5 kW, but decreased by 7.0% from 4.67 to 5.1.

Assessment of Daylight Environment on Light Pipe System Under Different Solar Position (태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가)

  • Shin, Hwa-Young;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

Comparison of Area vs Personal Total Dust Concentrations Measured by 37mm Closed-face Cassette and IPM Sampler (목재분진 농도 측정에 대한 37 mm closed-face 카세트법과 IPM 측정법 비교)

  • Lee, Dong-won;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.67-76
    • /
    • 1996
  • This study was performed to estimate total dust concentrations and particle size distribution of wood dust in the furniture and sawmill industries. To compare total wood dust concentrations, two samplers recommended by the American Conference of Governmental Industrial Hygienists and by the National Institute for Occupational Safety and Health were used. Concentration data were analyzed by paired-t tests using the SAS program and two parameters of the particle size distributions were determined by histogram. The results were as follows: 1. Particle size distributions showed a unimodal pattern in cutting and a bimodal in sanding operations. Mass median aerodynamic diameters(MMAD) were $17.35{\mu}m$ in cutting, and $1.39{\mu}m$ for small mode and $18.89{\mu}m$ for large mode in sanding operations. The proportions of particle size larger than $9.8{\mu}m$ estimated by the impactor were 61.16 % in cutting and 62.33 % in sanding operations, respectively. 2. The average personal total dust concentrations measured by IPM sampler were $17.12mg/m^3$ (GSD=1.45) from indoor samples, $2.97mg/m^3$(GSD=1.90) from outdoor samples in cutting, and $8.01mg/m^3$(GSD=1.58) from sanding operation. And those of by 37 mm closed-face cassette were $9.12mg/m^3$(GSD=1.46), $1.06mg/m^3$(GSD=1.99) from cutting, and $3.32mg/m^3$(GSD=2.16) from sanding operations. 3. The average area total dust concentrations measured by IPM sampler were $1.88mg/m^3$(GSD=2.04) from indoor cutting, $4.76mg/m^3$(GSD=2.83) from indoor sanding operations. And those of by 37mm closed-face cassette were $0.49mg/m^3$(GSD=2.34) from cutting, and $1.32mg/m^3$(GSD=3.03) from sanding operations. 4. The ratio of personal total dust concentrations measured by 37 mm closed-face cassette to those by IPM sampler were 35.7 %, 53.3 % from cutting, and 41.4 % from sanding operations. 5. The ratio of area total dust concentrations measured by 37 mm closed-face cassette to those by IPM sampler were 26.1 % from cutting, and 27.7 % from sanding operations. 6. A statistically significant difference of total dust concentrations between the 37 mm closed-face cassette and the IPM sampler was found.

  • PDF

BTEX and MTBE Concentrations in Residential Indoor Air Near Industrial Complex, Korea (공단지역 인근거주지의 실내 휘발성유기화합물류 농도)

  • Kim, Ho-Hyun;Lim, Young-Wook;Yang, Ji-Yeon;Lee, Yong-Jin;Suh, Il;Kim, Chang-Soo;Shin, Dong-Chun
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.2 s.57
    • /
    • pp.103-109
    • /
    • 2007
  • 대기 중 휘발성유기화합물류(VOCs)의 배출원은 매우 다양하며, 특히, 공단에서 배출되는 VOCs 노출로 인한 공단 주변거주지역 주민에게 배출특성 및 물질별 독성에 따라 유해한 건강 영향을 끼칠 가능성이 있다. 또한 일반가정에서의 자체 실내 오염원 또한 휘발성유기화합물류의 노출의 한 원인이다. 본 연구에서는 공단 주변 거주지역 및 동일 행정구역상의 비교지역을 선정하여 공단배출로 인한 실내유입 VOCs 노출 및 자체 실내오염원으로 인한 농도분포 및 기여정도를 조사하였다. 본 연구에서 공단주변 거주지역 및 비교지역의 조사된 실내 평균 농도는 MTBE 2.24, $2.47{\mu}g/m^3$, benzene 9.82, $8.51{\mu}g/m^3$, toluene 103.80, $83.57{\mu}g/m^3$, ethylbenzene 36.45, $15.52{\mu}g/m^3$, xylene 26.27, $1.00{\mu}g/m^34로 비교지역 거주지에 비해 공단지역 주변거주지의 실내공기 중 VOCs 의 농도가 높은 것으로 나타났다. 최종적으로 I/O ratio를 비교한 결과 조사 거주지 모두 자체 실내오염원이 있는 것으로 관찰되었고, 공단지역 주변거주지의 경우 공단의 VOCs 배출로 의해 추가 노출이 되는 것으로 각각 조사되었다.

Evaluation of Removal Efficiency in Emission Pollutants by Air Pollution Prevention Facilities from Meat Grilled Restaurants - Focus on the Electrostatic Precipitator - (직화구이 음식점 방지시설의 오염물질 저감 효과 평가 - 전기집진방식을 중심으로 -)

  • Seo, Jang-Won;Kim, Young-Il;Lee, Hee-Sun;Kim, Ji-Hun;Kim, Young-Doo;Shin, Jin-Ho
    • Particle and aerosol research
    • /
    • v.17 no.4
    • /
    • pp.115-123
    • /
    • 2021
  • The emission gas from meat grilled restaurants has unpleasant odor and sticky particulate matters (PM) in form of oil mist. This affects the residents living nearby. In oder to decrease the odor and PM, electrostatic precipitators (ESP) were installed at several restaurants by support of Seoul metropolitan government and emission characteristics of PM and odor were investigated. The removal efficiency of odor and PM at before- and after-ESP was that total hydrocarbon (THC), NH3, H2S, acetaldehyde, butyraldehyde were not much decreased. Total suspended particles (TSP) emitted from the vent was below the value of 7 mg/m3 regardless of the concentration of before-ESP and removal efficiency was in the range of 64 ~ 86%. The ratio of PM1.0 to PM10 of emission gas was over 0.9. So it was revealed that most PM of emission gas was PM1.0. The PM concentration in the air of the street near the vent was higher than another street due to the emission gas and the PM of indoor air of restaurant grilling meats was measured very high compared to outdoor air. So it needs more powerful ventilation of indoor air.

The Effects of Components of Grazing System on Welfare of Fattening Pigs

  • Tozawa, Akitsu;Tanaka, Shigefumi;Sato, Shusuke
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.3
    • /
    • pp.428-435
    • /
    • 2016
  • The objective of this study was to clarify the most effective component of grazing for improving welfare of fattening pigs. This study compared welfare indicators of 20 fattening pigs aged 100 to 124 days (the prior period) and 138 to 164 days (the latter period) in an indoor housing system (IS), an outdoor pasturing system (OP), a concrete floor paddock system (CF), a concrete floor paddock system with fresh grass (FG), or a soil floor paddock system (SF). The last three treatments include important components of a grazing system: extra space, grass feed, and soil floor. Behavior, wounds on the body, and performances, measured as average daily gain (ADG) and feed conversion ratio, were observed. CF pigs behaved similarly to IS pigs. FG pigs showed higher levels of foraging, chewing and activity. SF pigs engaged in higher levels of foraging, exploring, activity, and rooting, and showed a similar amount of playing behavior as OP pigs. ADG was the same in all treatments at the prior period, and increased in the order FG, IS, CF, SF, and OP at the latter. The behaviors and performance of SF pigs resembled those of OP which seemed to indicate a consistently higher standard of welfare than the other treatments. In conclusion, the existence of a soil floor is the most important component of a pasture for improving the welfare of pigs.

A game theory approach for efficient power control and interference management in two-tier femtocell networks based on local gain

  • Al-Gumaei, Y. A.;Noordin, K. A.;Reza, A. W.;Dimyati, K.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.7
    • /
    • pp.2530-2547
    • /
    • 2015
  • In the recent years, femtocell technology has received a considerable attention due to the ability to provide an efficient indoor wireless coverage as well as enhanced capacity. However, under the spectrum sharing between femtocell user equipment (FUEs) and the owner of spectrum macrocell user equipment (MUEs), both may experience higher uplink interference to each other. This paper proposes a novel distributed power control algorithm for the interference management in two-tier femtocell networks. Due to the assignment of licensed radio frequency to the outdoor macrocell users, the access priority of MUEs should be higher than FUEs. In addition, the quality of service (QoS) of MUEs that is expressed in the target signal-to-interference-plus-noise ratio (SINR) must always be achieved. On the other hand, we consider an efficient QoS provisioning cost function for the low-tier FUEs. The proposed algorithm requires only local information and converges even in cases where the frontiers of available power serve the target SINRs impossible. The advantage of the algorithm is the ability to implement in a distributed manner. Simulation results show that the proposed algorithm based on our cost function provides effective resource allocation and substantial power saving as compared to the traditional algorithms.

Analysis of Performance for SC-FDE Systems Using Proportional Adaptive Equalizer in $2GHz{\sim}10GHz$ Frequency Radio Channel Models ($2GHz{\sim}10GHz$ 무선 채널 환경에서 비례 적응형 등화기를 이용한 SC-FDE 시스템 구현과 성능분석)

  • Yang, Yong-Seok;Lee, Kyu-Tae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.4C
    • /
    • pp.447-453
    • /
    • 2007
  • In the multipath fading channel, OFDM(Orthogonal Frequency Division Multiplexing)system possess the characteristics of ISI/ICIwith prefix, but a weak point of circuit complexity and PAPR problem. SC-FDE(Single Carrier with Frequency Domain Equalization) performance is similar to OFDM system, but equalizer is complex in frequency domain. In this paper, simple proportional equalizer offer for SC-FDE system, it useful method in the $2GHz{\sim}\;10GHz$ channel model such as indoor, outdoor, SUI. It prove using MATLAB simulation, speed faster then OFDM system, reduce terminal complexity in same test condition.

An Ensemble Classifier Based Method to Select Optimal Image Features for License Plate Recognition (차량 번호판 인식을 위한 앙상블 학습기 기반의 최적 특징 선택 방법)

  • Jo, Jae-Ho;Kang, Dong-Joong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.142-149
    • /
    • 2016
  • This paper proposes a method to detect LP(License Plate) of vehicles in indoor and outdoor parking lots. In restricted environment, there are many conventional methods for detecting LP. But, it is difficult to detect LP in natural and complex scenes with background clutters because several patterns similar with text or LP always exist in complicated backgrounds. To verify the performance of LP text detection in natural images, we apply MB-LGP feature by combining with ensemble machine learning algorithm in purpose of selecting optimal features of small number in huge pool. The feature selection is performed by adaptive boosting algorithm that shows great performance in minimum false positive detection ratio and in computing time when combined with cascade approach. MSER is used to provide initial text regions of vehicle LP. Throughout the experiment using real images, the proposed method functions robustly extracting LP in natural scene as well as the controlled environment.

Distribution of airborne microorganism in the feedstuff manufacture factory (사료제조공장 내 공기 중 세균과 진균 분포에 관한 연구)

  • Kim, Ki-Youn;Jeong, Youn-Il;Kim, Chi-Nyon;Won, Jong-Uk;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.4
    • /
    • pp.335-342
    • /
    • 2007
  • The objective of the study is to investigate the distribution patterns of airborne bacteria and fungi in the feedstuff manufacture factory. The mean levels of airborne bacteria and fungi in the feedstuff manufacture factory were $113({\pm}18)cfu/m^3$ and $89({\pm}5)cfu/m^3$ for pelleting process and $198({\pm}5)cfu/m^3$ and $124({\pm}12)cfu/m^3$ for powdering process, respectively. The percentage of respirable and total concentration of airborne bacteria and fungi in the feedstuff manufacture factory ranged from 60% to 90% and were higher in pelleting process than powdering process. The ratio of indoor and outdoor airborne microorganism exceeded 1.0 regardless of types of feedstuff manufacture process. Based on the result of the study, there would be an association between environmental factors such as relative humidity and carbon dioxide and airborne microorganism's bioactivity.