DOI QR코드

DOI QR Code

Evaluation of Removal Efficiency in Emission Pollutants by Air Pollution Prevention Facilities from Meat Grilled Restaurants - Focus on the Electrostatic Precipitator -

직화구이 음식점 방지시설의 오염물질 저감 효과 평가 - 전기집진방식을 중심으로 -

  • Seo, Jang-Won (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Kim, Young-Il (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Lee, Hee-Sun (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Kim, Ji-Hun (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Kim, Young-Doo (Seoul Metropolitan Government Research Institute of Public Health and Environment) ;
  • Shin, Jin-Ho (Seoul Metropolitan Government Research Institute of Public Health and Environment)
  • 서장원 (서울특별시 보건환경연구원) ;
  • 김영일 (서울특별시 보건환경연구원) ;
  • 이희선 (서울특별시 보건환경연구원) ;
  • 김지훈 (서울특별시 보건환경연구원) ;
  • 김영두 (서울특별시 보건환경연구원) ;
  • 신진호 (서울특별시 보건환경연구원)
  • Received : 2021.10.06
  • Accepted : 2021.12.01
  • Published : 2021.12.31

Abstract

The emission gas from meat grilled restaurants has unpleasant odor and sticky particulate matters (PM) in form of oil mist. This affects the residents living nearby. In oder to decrease the odor and PM, electrostatic precipitators (ESP) were installed at several restaurants by support of Seoul metropolitan government and emission characteristics of PM and odor were investigated. The removal efficiency of odor and PM at before- and after-ESP was that total hydrocarbon (THC), NH3, H2S, acetaldehyde, butyraldehyde were not much decreased. Total suspended particles (TSP) emitted from the vent was below the value of 7 mg/m3 regardless of the concentration of before-ESP and removal efficiency was in the range of 64 ~ 86%. The ratio of PM1.0 to PM10 of emission gas was over 0.9. So it was revealed that most PM of emission gas was PM1.0. The PM concentration in the air of the street near the vent was higher than another street due to the emission gas and the PM of indoor air of restaurant grilling meats was measured very high compared to outdoor air. So it needs more powerful ventilation of indoor air.

Keywords

References

  1. Bong, C.K., Park, S.J., Kim, J.H., Park, S.K., Jeon, J.M., and Hwang, U.H. (2009). Characteristics of odor- ous pollutants from cooking of meats, Journal of Korean Society of Urban Environment, 9(2), 49-56.
  2. Capelli, L., Sironi, S., Rosso, R.D., and Guillot, J.M. (2013). Measuring odors in the environment vs. dispersion modelling: A Review, Atmospheric Environment, 79, 731-743. https://doi.org/10.1016/j.atmosenv.2013.07.029
  3. Cho, Y.M., and Hong, Y.C. (2014). Health effects from PM and the role of Korean Medical Association, Research Institute for Healthcare Policy, 12(2), 32-36.
  4. Guadagni, D.G., Buttery, R.G., Okano, S., and Burt, H.K. (1963). Additive effect of sub-threshold concentrations of some organic compounds associated with food aromas, Nature, 200, 1288-1289. https://doi.org/10.1038/2001288a0
  5. Ham, T.S., and Jung, S.J. (2020). A study on legal issues and improvement plans for the management of grilled restaurants as a source of PM, Law of Environment and Policy, 24, 95-120. https://doi.org/10.18215/elvlp.24..202002.95
  6. Hong, S.S. (2008). Investigation on the heavy metals transferred from charcoal, Ministry of Food and Drug Safety, 118-119.
  7. Lee, H.D., Jeon, S.B., Choi, W.J., Lee, S.S., Lee, M.H., and Oh, K.J. (2013). A novel assessment of odor sources using instrument analysis combined with resident monitoring records for an industrial area in Korea, Atmospheric Environment, 74, 277-290. https://doi.org/10.1016/j.atmosenv.2013.04.001
  8. Lee, J.B., Kim, K.H., Kim, H.J., Cho, S.J., Jung, K., and Kim, S.D. (2011). Emission rate of particulate matter and its removal efficiency by precipitators in under-fired charbroiling restaurants, ScientificWorldJournal, 11, 1077-1088. https://doi.org/10.1100/tsw.2011.103
  9. Lee, T.J., Kim, S.C., Jeon, J.M., Kim, D.S., and Jo, Y.M. (2019). Evaluation of odor emission characteristics and contribution of meat grilling restaurants, Journal of Odor and Indoor Environment, 18(2), 121-130. https://doi.org/10.15250/joie.2019.18.2.121
  10. Park, S.K., Choi, S.J., Kim, J.Y., Lee, H.J., Jang, Y.G., Bong, C.K., Kim, J.H., and Hwang, U.H. (2011). A study on the development of particulate matters emission factors from biomass burning: mainly commercial cooking, Journal of Korean Society for Atmospheric Environment, 27(4), 426-435. https://doi.org/10.5572/KOSAE.2011.27.4.426
  11. Park, S.K., Choi, S.J., Park, G.J., Kim, J.Y., Bong, C.K., Park, S.J., Hwang, U.H., and Kim, J.H. (2009). Experimental study on the controller of oil mist and PM from meat cooking, Journal of Korean Society of Urban Environment, 9(2), 93-98.
  12. Seo, Y.H., Ko, K.Y., and Jang, Y.K. (2010). Determination of cholesterol, fatty acids and polyaromatic hydrocarbons in PM10 particles collected from meat charbroiling, Korean Society of Environment Engineers, 32(2), 155-164.