• 제목/요약/키워드: incinerator

검색결과 372건 처리시간 0.031초

The Role of (Chloro-) Phenols in the Formation of Polychlorinated Dibenzofurans in Municipal Waste Incinerators

  • Ryu, Jae-Yong;Jang, Seong-Ho
    • 한국환경과학회지
    • /
    • 제16권1호
    • /
    • pp.9-19
    • /
    • 2007
  • Comparing predicted PCDF isomer patterns with those obtained from a municipal waste incinerator assessed the role of two-phenol condensation pathways in the formation of PCDFs. Complete PCDF homologue and isomer distributions were obtained from a Fluidized Bed Incinerator (FBI). Two-phenol condensation model, dependent only on the distributions of phenols, was developed to predict the PCDF congeners produced from phenol precursors. R-squared values from linear correlations are presented for the dichlorinated through hexa-chlorinated isomer distributions between measured and predicted. They range from 0.00: to 0.1 far the di-chlorinated through hexa-chlorinated isomer sets. Agreement between predicted and measured PCDF isomer distributions was very poor for all homologues. Two-phenol condensation pathways are not likely to be the pre-dominant pathways in the formation of PCDF in a FBI. However, dibenzofuran (DF) is likely to be produced from a condensation of two phenols. This work demonstrates the use of PCDF homologue and isomer patterns for testing PCDF formation mechanism from two-phenol condensation pathways in municipal waste incinerators.

Performance of a Pilot-scale Rice Husk Incinerator

  • Park, Seung J.;Kim, Myoung H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.906-917
    • /
    • 1996
  • This study was conducted to find possible application areas of the by-products generated from the incineration of rice husk. To this end, a pilot-scale rice husk incinerator system was constructed and its performed test was carried. Major findings are summarized as follows. 1. The rice husk incinerator system developed in this study performed satisfactory in terms of thermal efficiencies. At the optimum operating conditions, thermal conversion efficiency and heat exchanger efficiency was 97% ad 60%, respectively, while overall thermal efficiency of the system was 58%. Under all conditions tested, temperatures in the combustion chamber were quite uniform and crystallization of SiO$_2$ in the ash was negligible. 2. NOx and SOx content in the flue gas was well below the legal limit but the CO concentration was around the legal limit. 3. Thermal energy from combustion was successfully recovered by a heat exchanger to provide hot water, ash was found a good supplementary cementing m terial, and the flue gas also was an acceptable $CO_2$ supplier to greenhouses.

  • PDF

소나무 잎을 이용한 대기 중 다이옥신/퓨란 발생원 추정 (Source Tracking of PCDD/Fs in Ambient Air Using Pine Needles)

  • 천만영;김정수;고도현
    • 한국환경보건학회지
    • /
    • 제41권1호
    • /
    • pp.49-60
    • /
    • 2015
  • Objectives: Pine needles were used as a passive air sampler (PAS) of atmospheric persistent organic pollutants (POPs). This study was performed to investigate concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) deposited on pine needles near a waste incinerator and PCDD/Fs source contributions using principal component analysis (PCA). Methods: Two-year-old pine needles were sampled at 11 points with respect to distance and wind direction from the incinerator. PCDD/Fs deposited on pine needles were analyzed with HRGC/HRMS. The source contribution of PCA was calculated with SPSS. Results: The average concentration of PCDD/Fs deposited on pine needle was 0.79 (0.27-1.76) pg TEQ/g dry, PCDDs with 0.24 (0.01-0.95) pg TEQ/g dry and PCDFs with 0.56 (0.27-0.82) pg TEQ/g dry, respectively. The average concentration fraction of PCDDs was 29.7%, that of PCDFs was 70.3%, and PCDFs were more prevalent than PCDDs. The contributions of PCDD/Fs sources were estimated as incineration at 58.3% and automobiles at 28.4%. However, a relation and regulation between PCDD/Fs concentrations deposited on pine needles and distance from incinerator or wind direction was not shown. Conclusion: It was concluded that atmospheric PCDD/Fs concentrations near an industrial complex with a waste incinerator were affected by multiple sources. However, PCDD/Fs concentrations were lower than in other inland cities with the exception of background area.

G+R 타입 소각연소로의 연소 및 열유동 특성평가 연구 (An Evaluation Study on Combustion and Thermal Flow Characteristics of G+R Type Incinerator)

  • 신동훈;황정호;Ik-Hyun;정상순
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 제26회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.111-117
    • /
    • 2003
  • The present study discusses about the combustion and thermal flow characteristics of a G+R type incinerator, which is under construction for MAPO Incineration system, to evaluate the effects of various operating and design parameters. A bed combustion model is developed to simulate the waste bed combustion on the stoker. The effects of waste composition and primary air distribution are estimated. The results of the waste bed combustion model is applied to CFD(computational fluid dynamics) simulation, which simulates the detail of the thermal flow in the combustion chamber. The effects of bypass damper opening ratio, primary air distribution, and secondary air jet configuration are discussed.

  • PDF

Pilot 규모의 열분해 용융 소각 시스템에서의 열분해 및 연소 특성 연구 (A Study on the Pyrolysis and Combustion Characteristics of Solid Waste in a Pilot scale Pyrolysis Melting Incinerator)

  • 류태우;양원;박주원;김봉근;이기방;김희열;박상신;전금하
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.168-174
    • /
    • 2006
  • A pilot scale (200kg/hr) pyrolysis melting incineration system is designed and constructed in Korea Institute of Industrial Technology. The incineration process is composed of pyrolysis, gas combustion, ash melting, gas stabilization, waste heating boiler, and bag filter. For each unit process, experimental approaches have been conducted to find optimal design and operating conditions. Especially, a pyrolysis is very important process in that it is a way of energy recirculation and minimizing the waste products. This paper presents major results of the most efficient operating conditions in a pilot scale pyrolysis melting incinerator.

  • PDF

소각로에서의 연소가스 체류시간 (The residence time of gas in an incinerator)

  • 김성준
    • 산업기술연구
    • /
    • 제36권
    • /
    • pp.3-7
    • /
    • 2016
  • The change of flue gas residence time with the location of air inlet in an incinerator is analysed. An independent numerical variable is the location of air inlet and dependant is the residence time of flue gas. The mean value of turbulence energy in a primary combustion chamber is also analysed. The flow field and the distribution of turbulence energy are investigated to evaluate their influence on the residence time of flue gas and the turbulence energy. As the position of secondary air inlet approaches to the top of primary combustion chamber, the residence time of gas and the turbulence energy become longer and larger respectively.

  • PDF

2차 공기 주입 조건 변화에 따른 소형 소각로 내부의 유동장 분석 (Analysis of the Gas Flow Field of Primary Combustion Chamber with the Conditions of Secondary Air Injection)

  • 최병대;김성준
    • 산업기술연구
    • /
    • 제22권A호
    • /
    • pp.9-17
    • /
    • 2002
  • This analysis is aimed to find out how the conditions of secondary air injection affects the residence time and the turbulence energy of flue gas and flow field in a small incinerator. A commercial code, PHOENICS, is used to simulate the flow field of an Incinerator. The computational grid system is constructed in a cartesian coordinate system In this numerical experiment, an independent numerical variable is the conditions of secondary air injection and dependants are the residence time of flue gas and the mean value of turbulence energy in a primary combustion chamber. The flow field and the distribution of turbulence energy are analysed to evaluate the residence time of flue gas and the turbulence energy The computational results say that the tangential injection of secondary air make the residence time much longer than the radial injection and that the radial injection of secondary make turbulence much stronger than the tangential injection.

  • PDF

도시고형폐기물 소각 비산재의 지반공학적 특성 및 시멘트 안정화에 관한 연구 (The Geotechnical Properties of Municipal Solid Waste Incinerator Fly Ash and Cement Stabilization)

  • 조진우;김지용;한상재;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.528-535
    • /
    • 2000
  • Solid waste incinerator is expected to become widely used in Korea. The incineration of solid waste produces large quantities of bottom and fly ash, which has been disposed of primary by landfilling. However, as landfills become undesirable other disposal method are being sought. In this study, an experimental research is conducted to determine the geotechnical properties of municipal solid waste incinerator fly ash(MSWIF) in order to evaluate the feasibility of using the material for geotechnical applications. Basic pysicochemical characteristics, moisture-density relationship, strength, permeability, and leaching characteristics are examined. The results of MSWIF are compared to other MSWIF and coal fly ash which are used as construction material. In addition, the effectiveness of cement stabilization is investigated using various mix ratios. The result of stabilized mixes are compared to the unstabilized material. Cement stabilization is found to be very effective in reducing permeability, increasing strength, and immobilizing heavy metals. This results indicate that MSWIF with cement stabilization may be used effectively for geotechnical application.

  • PDF

고형폐기물 소각로에서 배출되는 대기오염물질간의 상관성에 관한 연구 (A Study on the Correlation Level Among Air Pollution from Solid waste Incinerator)

  • 조상원
    • 한국환경과학회지
    • /
    • 제8권2호
    • /
    • pp.183-187
    • /
    • 1999
  • The purpose of this study is providing basic data to control the air pollutants from solid waste incinerator. Incinerating the waste wood, the electrostatic precipitator had the best collection efficiency. The leather incineration had the same collection efficiency as synthetic resin incineration. And the coarse particle collection efficiency was high. As you know in correlation of leather incineration. pollutants produced a from incinerator are mostly fine particles. If the scrubber used only in the process produced a lot of fine particles. It is adequate to use the above control devices, together with high efficiency collector like bag-filter. To select the adequate control devices, it is required to investigate the size distribution before establishing control devices.

  • PDF

순환골재 및 소각장 애시를 자극제로 사용한 고로슬래그 미분말 다량치환 콘크리트의 Mock-up 성능평가 (Mockup Test of the High Volume Blast Furnace Slag Concrete Using Recycled Aggregates and Incinerator Ash)

  • 김영희;곽용진;김준호;이향재;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.19-21
    • /
    • 2012
  • This paper was to investigate the effect of incinerator ash on engineering properties of the high volume blast furnace slag concrete through Mock-up test. Test results revealed that the use of recycled aggregates resulted in increase of slump compared with the OPC concrete. But, the use of recycled aggregates did not affect the results of air contents and chloride contents. The use of recycled aggregates showed shortening of setting time of high volume blast furnace slag concrete. When the recycled aggregate was used, delay in strength development at early age happened with high volume blast furnace slag concrete compared with that of OPC concrete.

  • PDF