• Title/Summary/Keyword: inaccuracy

Search Result 454, Processing Time 0.034 seconds

Three Dimensional Construction Stage Analysis and Deformation Monitoring of a Reinforced Concrete Highrise Building (철근콘크리트조 초고층건물의 3차원 시공단계 해석 및 시공중 변형 계측)

  • Jeong, Daegye;Yu, Eunjong;Ha, Taehun;Lee, Sungho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.6
    • /
    • pp.573-580
    • /
    • 2014
  • In this paper, axial strains and lateral displacements of columns in a 58-story reinforced concrete building were measured using vibrating wire gauge and laser scanner, respectively, and compared with predicted values. Predictions were obtained using ASAP, which is a 3D construction stage analysis program developed based on PCA report. Comparisons indicated that columns in the middle of floor plan showed good correlation with predictions. However, the columns in the corners showed some deviations. Lateral displacement of columns between measurement and estimation showed similar trends but considerable deviations, which are seemingly caused by construction error of column faces, and inaccuracy in differential vertical displacement prediction.

Evaluation of shear lag parameters for beam-to-column connections in steel piers

  • Hwang, Won-Sup;Kim, Young-Pil;Park, Yong-Myung
    • Structural Engineering and Mechanics
    • /
    • v.17 no.5
    • /
    • pp.691-706
    • /
    • 2004
  • The paper presents shear lag parameters for beam-to-column connections in steel box piers. Previous researches have analyzed beam-to-column connections in steel piers using a shear lag parameter ${\eta}_o$ obtained from a simple beam model, which is not based on a reasonable design assumption. Instead, the current paper proposes a cantilever beam model and has proved the effectiveness through theoretical and experimental studies. The paper examines the inaccuracy of the previous researches by estimating the effective width, the width-span length ratio L/b, and the sectional area ratio S of a cantilever beam. Two different shear lag parameters are defined using the cantilever model and the results are compared each other. The first type of shear lag parameter ${\eta}_c$ of a cantilever beam is derived using additional moments from various stress distribution functions while the other shear lag parameter ${\eta}_{eff}$ of a cantilever beam is defined based on the concept of the effective width. An evaluation method for shear lag stresses has been investigated by comparing analytical stresses with test results. Through the study, it could be observed that the shear lag parameter ${\eta}_{eff}$ agrees with ${\eta}_c$ obtained from the $2^{nd}$ order stress distribution function. Also, it could be observed that the shear lag parameter ${\eta}_c$ using the $4^{th}$ order stress distribution function almost converges to the upper bound of test results.

Fuzzy-AHP-Based Technology Evaluation Model for venture firms (Fuzzy-AHP에 기반을 둔 벤처기업의 기술력 평가 모델)

  • Joun, Hyang-Soon;Lee, Sang-Yong
    • Journal of Digital Convergence
    • /
    • v.14 no.7
    • /
    • pp.363-371
    • /
    • 2016
  • Technology evaluation for technology innovation of venture firms should take the rapidly changing corporate environment, the ambiguity of language used in evaluation, and the inaccuracy of evaluation index into consideration. In this paper, targeting the absorptive capacity and technological entrepreneurship which are typical evaluation factors of venture firms, an ACTEM model to calculate the importance, priority, and dynamic capability of factors, applying Fuzzy-AHP was proposed. The fuzzy theory was introduced to compensate for the ambiguity of cognitive judgments when calculating weighted values for the factors that made up an assessment scale. An assessment criteria framework for absorptive capacity, technological entrepreneurship, and dynamic capability, which were not considered in previous studies on the evaluation and measurement of technological prowess, so that the users could have a realistic alternative to choose. The study compared the ACTEM model with the old AHP assessment method and found that "knowledge acquisition" and "producing ability" were the highest in absorptive capacity and technological entrepreneurship, respectively, thus demonstrating its validity.

A Study on Status and Accuracy of Underground Facilities Maps (지하시설물도 현황 및 정확도 분석에 관한 연구)

  • Lee, Yong-Wook;Heo, Min;Lee, Jae-One;Bae, Kyoung-Ho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.3
    • /
    • pp.223-230
    • /
    • 2007
  • As the centralization of city, underground facilities is increasing and being more important. Although the importance of underground facilities map has been emphasized, there were many accidents related underground facilities. The inaccuracy of existing data and the carelessness of management caused many accidents. It is very important to update and to have high quality accuracy of underground facilities maps. But the underground facilities maps are mapped and updated by each institutes. So it is difficult to verify the accuracy of the data. In this study, Field Test is performed to analyze the horizontal accuracy of existing maps using Electromegnetic Induction Method, Total Station and GPS. Surveying of underground facilities in Seoul was performed for 6 institutes of underground facilities during 3 years. The aim of this study is to verify the horizontal accuracy of data and to improve the accuracy of underground facility maps. As the result of analysis, the horizontal accuracy of 6 underground facilities management institutes is 73 cm(2004), 78 cm(2005) and 75 cm(2006).

Ka-Band FMCW Sensor with High Linearity (고선형성을 갖는 Ka대역 FMCW 센서)

  • Kim, Jaehwan;Lee, Sungju;Kwon, Hyukja;Yang, Youngoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.6
    • /
    • pp.671-678
    • /
    • 2014
  • This paper presents a Ka-band FMCW sensor that has high linearity by improving a nonlinear behavior of the voltage controlled oscillator. Due to the nonlinear characteristics of the voltage controlled oscillator for the conventional method, the drift of beat frequency can cause inaccuracy and errors to the extracted results. A Ka-band FMCW signal with fast transition time could be generated by using both direct digital synthesizer and phase locked loop in this research. The implemented FMCW sensor showed very high accuracy in beat frequency through the test.

Performance Improvement of Continuous Digits Speech Recognition using the Transformed Successive State Splitting and Demi-syllable pair (반음절쌍과 변형된 연쇄 상태 분할을 이용한 연속 숫자음 인식의 성능 향상)

  • Kim Dong-Ok;Park No-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.8
    • /
    • pp.1625-1631
    • /
    • 2005
  • This paper describes an optimization of a language model and an acoustic model that improve the ability of speech recognition with Korean nit digit. Recognition errors of the language model are decreasing by analysis of the grammatical feature of korean unit digits, and then is made up of fsn-node with a disyllable. Acoustic model make use of demi-syllable pair to decrease recognition errors by inaccuracy division of a phone, a syllable because of a monosyllable, a short pronunciation and an articulation. we have used the k-means clustering algorithm with the transformed successive state splining in feature level for the efficient modelling of the feature of recognition unit . As a result of experimentations, $10.5\%$ recognition rate is raised in the case of the proposed language model. The demi-syllable pair with an acoustic model increased $12.5\%$ recognition rate and $1.5\%$ recognition rate is improved in transformed successive state splitting.

An Improvement on Testability Analysis by Considering Signal Correlation (신호선의 상관관계를 고려한 개선된 테스트용이도 분석 알고리즘)

  • 김윤홍
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.1
    • /
    • pp.7-12
    • /
    • 2003
  • The purpose of testability analysis is to estimate the difficulty of testing a stuck-at fault in logic circuits. A good testability measurement can give an early warning about the testing problem so as to provide guidance in improving the testability of a circuit. There have been researches attempting to efficiently compute the testability analysis. Conventional testability measurements, such as COP and SCOAP, can calculate the testability value of a stuck-at fault efficiently in a tree-structured circuit but may be very inaccurate for a general circuit. The inaccuracy is due to the ignorance of signal correlations for making the testability analysis linear to a circuit size. This paper proposes an efficient method for computing testability analysis, which takes into account signal correlation to obtain more accurate testability. The proposed method includes the algorithm for identifying all reconvergent fanouts in a given n circuit and the gates reachable from them, by which information related to signal correlation is gathered.

  • PDF

Calibration by Comparison and Uncertainty Assessment of Industrial Thermometers at the Boiling Point of Nitrogen (질소의 끓는점에서의 산업용 온도계 비교 교정과 불확도 평가)

  • Yang, Inseok;Gam, Kee Sool;Joung, Wukchul;Kim, Yong-Gyoo
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.404-409
    • /
    • 2013
  • We devised calibration procedure for industrial thermometers by a comparison method at the boiling point of nitrogen (${\sim}-196^{\circ}C$). The uncertainty of the calibration was 4 mK (k = 2). As experimentally demonstrated in this work, the effect of the atmospheric pressure on the boiling point of nitrogen can be easily detected by the thermometer. Therefore, when the boiling point of nitrogen is used for calibration of thermometer by comparison, either a reference thermometer must be used to provide the reference temperature or the effect of atmospheric pressure should be carefully considered. The use of a copper block with a large thermal mass soaked into the liquid nitrogen was proven to be more reliable, and the stability of the temperature immersed into the copper block was 1.4 mK. The temperatures at the thermometer wells, evaluated by the crossed-measurement method to compensate for the inaccuracy of the thermometers and the linear drift of the temperature of the copper block, were equivalent within 0.23 mK of standard uncertainty.

Particulate Matter Prediction using Quantile Boosting (분위수 부스팅을 이용한 미세먼지 농도 예측)

  • Kwon, Jun-Hyeon;Lim, Yaeji;Oh, Hee-Seok
    • The Korean Journal of Applied Statistics
    • /
    • v.28 no.1
    • /
    • pp.83-92
    • /
    • 2015
  • Concerning the national health, it is important to develop an accurate prediction method of atmospheric particulate matter (PM) because being exposed to such fine dust can trigger not only respiratory diseases as well as dermatoses, ophthalmopathies and cardiovascular diseases. The National Institute of Environmental Research (NIER) employs a decision tree to predict bad weather days with a high PM concentration. However, the decision tree method (even with the inherent unstableness) cannot be a suitable model to predict bad weather days which represent only 4% of the entire data. In this paper, while presenting the inaccuracy and inappropriateness of the method used by the NIER, we present the utility of a new prediction model which adopts boosting with quantile loss functions. We evaluate the performance of the new method over various ${\tau}$-value's and justify the proposed method through comparison.

Long Term Follow Up of Maxilla Reconstruction Following the Ablative Cancer Surgery (악성종양 절제술 후 상악 재건의 장기 추적관찰)

  • Lee, Han Earl;Ahn, Hee Chang;Choi, M.Seung Suk;Jo, Dong In
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.448-454
    • /
    • 2007
  • Purpose: The objective of this study was to evaluate the outcomes of using the free flap in the reconstruction of maxillary defects. Methods: 27 consecutive cases of maxillary reconstruction with free flap were reviewed. All clinical data were analyzed, including ideal selection of flap, time of reconstruction, recurrence of cancer, postoperative complications, flap design, and follow-up results. The main operative functional items, including speech, oral diet, mastication, eye globe position and function, respiration, and aesthetic results were evaluated. Results: Among the 24 patients who underwent maxillary reconstruction with the free flap, 14 patients underwent immediate reconstruction after maxillary cancer ablation, and 10 patients underwent delayed reconstruction. There occurred 1 flap loss. Recurrences of the cancer after the reconstruction happened in 2 cases. Postoperative complications were 3 cases of gravitational ptosis of the flap, 2 cases of the nasal obstruction, and 1 case of fistula formation. Out of 27 free flaps, there were 15 latissimus dorsi myocutaneous flaps, 5 radial forearm, 4 rectus abdominis myocutaneous flaps, 1 scapular flap, 2 fibula osteocutaneous flap, respectively. Flaps were designed such as 1 lobe in 9 cases, 2 lobes in 9 cases, and 3 lobes in 5 cases. Among the 14 patients who had intraoral defect or who had palatal resection surgery, 2 patients complained the inaccuracy of the pronunciation due to the ptosis of the flap. It was corrected by the reconstruction of the maxillary buttress and hung the sling to the upper direction. All of the 14 patients were able to take unrestricted diets. In 6 patients who had reconstruction of inferior orbital wall with rib bone graft, they preserved normal vision. Aesthetically, most of the patients were satisfied with the result. Conclusion: LD free flap is suggested in uni-maxilla defect as the 1st choice, and fibular osteocutaneous flap and calvarial bone graft to cover the larger defect in bi-maxilla defect.