• Title/Summary/Keyword: in-site test

Search Result 3,231, Processing Time 0.031 seconds

How do Internet Fashion Shoppers and Non-shoppers Differ? -Emphasis on Their Fashion Shopping Orientation and Shopping Site Attitude- (인터넷 패션 구매경험자와 무경험자 특성 비교 -패션 쇼핑성향과 쇼핑사이트 서비스에 대한 태도의 차이-)

  • Jeon, Yang-Jin;Sung, Hee-Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.9
    • /
    • pp.1387-1396
    • /
    • 2008
  • The objective of this study was to identify differences between internet fashion shoppers and non-shoppers in their fashion shopping orientation and attitude toward internet shopping site service. Also behavior of internet shoppers and non-shoppers was compared by gender. Twelve hundred and ninety two responses were obtained from an online survey. 20 items were used to measure shopping orientation and 13 items to measure attitude toward internet shopping site service, which were modified from previous studies. Some demographics and internet familiarity were asked. Factor analysis, t-test, chi-square test, and regression were conducted. Factor analysis produced five fashion shopping orientation factors such as fashion oriented, shopping oriented, brand oriented, personality oriented, and value oriented. Attitude toward internet shopping site service were classified into three factors, at-site service, after purchasing service, and product information. Internet fashion shoppers and non-shoppers were significantly different in most items of shopping orientation and attitude toward internet site service. Internet shoppers were likely to be fashion oriented, to enjoy shopping, to pursue brandname and personality, and to concern price more than non-shoppers were. Internet shoppers also had more favorable attitude toward product information and at-site service. Also, shoppers were more familiar than non-shoppers to the internet in terms of duration of web-browsing. Ratio of men and women differed significantly for shopper vs. non-shopper groups. Female shoppers were likely to be more fashion, shopping. and value oriented but to have less favorable attitude for after purchasing service than male shoppers.

Preliminary Application of Stone Conservation Technology for Monitoring of Vat Phou World Heritage Site

  • Sengphachanh, Amphol;Lee, Myeong Seong;Choi, Tae Jeong;Chun, Yu Gun
    • 보존과학연구
    • /
    • s.36
    • /
    • pp.86-96
    • /
    • 2015
  • From the Asia Cooperation Program on Conservation Science(ACPCS) of National Research Institute of Cultural Heritage(NRICH), I gained conservation and management experience and knowledges which are highly applicable at the Vat Phou World Heritage site. Firstly, Check list, Mapping, Tape Test and Digital Image Analysis are simple and useful methods which can be introduced to the site directly. If we can get chance to learn more about GIS program, GIS based Database Management System would also be very liable to put into practical use since the site office has been already using the program for general purpose. Lastly, there are more other methods which can diversify the studies on cultural heritage conservation in Laos; Rebound Hardness Test, Ultrasonic Test, Infrared Thermography, XRF Analysis and Hyperspectral Image Analysis etc. To realize those research however, new equipments are needed along with proper education so more cooperation between Korea and Lao would be essential.

  • PDF

Conformance Test for the Terrestrial DMB Broadcast Web Site (지상파 DMB 방송웹사이트 송수신 정합 시험 기술)

  • Moon, Su-Han;Kim, Yong-Han;Chae, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.75-77
    • /
    • 2006
  • In this paper, the technology of the conformance test for Broadcast Web Site Service (BWS) which is one of the data services of the T-DMB (Terrestrial Digital Multimedia Broadcasting) is proposed. First, the standard of the BWS Service is introduced and then the method of the conformance test of BWS bitstream and BWS receiver module is provided. A BWS bitstream analyzer is implemented for use in verifying the transmitted BWS bitstreams. To provide a means for the receiver manufactures to verify their own BWS receiver modules, a receiver test suite is developed including BWS test bitstreams and a BWS reference receiver module. The BWS bitstream analyzer includes the analysis function for the conformance test of MOT protocol, HTML, PNG, MNG, JPEG, and Ecma Script. Also, it was actually used for verifying the BWS test bitstreams. In the course of developing a HWS receiver module, 4he BWS receiver module under test can be verified by comparing the results of the BWS reference receiver module with those of the receiver module under test. when the same BWS test bitstreams are fed into the two receiver modules.

  • PDF

A Study on Development of Test Site for Wind Turbine Prototype Test (풍력터빈시험을 위한 실증시험장 개발에 관한 연구)

  • Moon, Chae-Joo;Chang, Young-Hag;So, Soon-Yeol;Kim, Tae-Gon;Kim, Young-Gon;Jeong, Moon-Seon;Jeong, Seong-Won
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.101-107
    • /
    • 2013
  • It is evident that in the wind energy business as an economic activity there is a close relationship between the wind speed and the revenues. The wind turbine test facility for wind turbine accreditation is intended to be used by the industry for testing of both main components and systems. This paper suggest the wind test site for certification of prototype wind turbine with international regulations. The test site has an environmental permit for wind turbines with a maximum hub height of 120m and a rotor diameter up to 120m, and can accommodate prototypes with installed electrical powers up to 5MW each. A wind turbine manufacturer can lease the location for a period of type certification. And also researchers are the development of new methods for measuring the influence, performance and durability of the components, a mathematical and numerical modelling of component responses by using the site.

Investigation of the groundwater contamination around landfill where slaughtered animals were buried

  • Bark, Jun-Jo;Jung, Hae-Sun;Woo, Jong-Tae;Lee, Sung-Sik
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.4
    • /
    • pp.459-467
    • /
    • 2006
  • This study was designed to investigate if there were groundwater contamination in 17 landfill where slaughtered animals were buried during the crisis of 2002 foot-and-mouth-disease (FMD) outbreaks in Gyeonggi province. From March to August 2005 groundwater was collected once a month from 17 sites, and examined with potential for hydrogen (pH), colour, turbidity, lead (Pb), arsenic (As), mercury (Hg), cadmium (Cd), copper (Cu), zinc (Zn) , iron (Fe), manganese (Mn) , aluminium (Al), nitrate-nitrogen $(NO_3-N)$, ammonia-nitrogen $(NH_3-N)$, microbial pathogen and Escherichia spp. In the examination of $NH_3-N$ which of the mean concentration was from not-detected (ND) to 0.05 mg/l. The range of $NH_3-N$ level was $0.3-24.1mg/{\ell}$. However, groundwater from four sites was to go beyond the drinking water quality standard (DWQS), i.e., the mean concentration of those were $15.5mg/{\ell}\;(site\;1),\;20.7mg/{\ell}\;(site\;9),\;24.1mg/{\ell}\;(site\;13)\;and\;10.6mg/{\ell}\;(site\;17)$. In the investigation of pH, colour and turbidity, all of the pH were below of DWQS (pH 5.8-6.6), but one site in color test and four sites in turbidity test were over the standard level. Among 9 metal ions examined, Mn was in excess of DWQS, and its concentration was $2.4mg/{\ell}$. Pb, Cd, Hg and As were not traced. The contents of Cu, Zn, Fe and Al were $ND-0.22mg/{\ell},\;0.01-0.05mg/{\ell},\;ND-0.05mg/{\ell}\;and\;0.03-0.16mg/{\ell}$, respectively. Escherichiae spp were not identified, but bacterial colonies were detected at 3 groundwater including 2 sites over the DWQS at the level of $491CFU/m{\ell}\;(site\;4)\;and\;217CFU/m{\ell}\;(site\;15)$.

An Experimental Study on the Optimum Mix Design and Site Application Case of Soil Mixing Wall for Trench Stability (구벽안정성을 위한 SMW 최적배합비 및 현장적용 사례에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.419-426
    • /
    • 2015
  • The purpose of this study is to investigate experimentally the optimum mix design and site application case of soil mixing wall (SMW) method which is cost-effective technique for construction of walls for cutoff wall and excavation support as well as for ground improvement before constructing LNG storage tank typed under-ground. Considering native soil condition in site, main materials are selected ordinary portland cement, bentonite as a binder slurry and also it is applied $1,833kg/m^3$ as an unit volume weight of native soil, Variations for soil mixing wall are as followings ; (1) water-cement ratio 4cases (2) mixing velocity (rpm) 3levels (3) bleeding capacity and ratio, compressive strength in laboratory and site application test. As test results, bleeding capacity and ratio are decreased in case of decreasing water-cement ratio and increasing mixing velocity. Required compressive strength (1.5 MPa) considering safety factors in site is satisfied with the range of water-cement ratio 150% below, and test results of core strength are higher than those of specimen strength in the range of 8~23% by actual application of element members including outside and inside in site construction work. Therefore, optimum mix design of soil mixing wall is proposed in the range of unit cement $280kg/m^3$, unit bentonite $10kg/m^3$, water-cement ratio 150% and mixing velocity 90rpm and test results of site application case are satisfied with the required properties.

A Fundermental Study on Stabilization in Municipal Waste Landfill Site (도시폐기물 매립지의 안정화에 관한 기초연구)

  • 김은호;김순호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.56-62
    • /
    • 2001
  • The investigation was carried out to analyze the generation and the composition of landfill gas generated from inserted pipe wells into the underground by boring operation and also study the undecomposed waste characteristics by open-cut test at S. waste landfill site in Pusan city. Pilot test was conducted for stabilization. The experimental results from this study were summerized as follows. ; Since COD matter was easuer decomposed than COD matter for continuously biological stabilization in underground, it seemed that BOD and CO $D_{Mn}$ were in the range of 854~4,813mg/$\ell$ and 1,156~6,977mg/$\ell$ and their ratio were generally as high as 0.55~0.74. As C $H_4$ compositions of generated gas were measured in the range of 37.36~60.1%, we could know that C $H_4$ gas was actively generated. Organic matters by open-cut test averaged 13.4~16.6% at each landfill layer, and considering rate of combustible compositions(36.2~66.5%) for landfilling wastes, they have been actively decomposed. The measured and theoretical values of generated gas in waste landfill site were almost similar to C $H_4$ 50.0% and 53.4%, $CO_2$ 39.63% and 45.24%, and after 0.5$^{\circ}C$ with heavy depth and long landfill period. From the results of pilot test for stabilization, after 180 days organic matters were actively decomposed beyond 2.2 times in facultative aerobic lystimeter(B) to exsiting anaerobic lysimeter(A). Therefore, it seemed that landfill site was of benefical to the conversion of facultative aerobic for stabilization.

  • PDF

In-situ Performance Test and Prediction of a 10 RT Air Source Heat Pump (10RT급 공기열원 열펌프의 현장 성능측정 및 예측)

  • 김영일;백영진;장영수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.3
    • /
    • pp.221-230
    • /
    • 2002
  • In this study, in-situ performance test of an air source heat pump which has a arted capacity of 10 RT is carried out. Since test conditions, such as indoor and outdoor air conditions cannot be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. To estimate the performance for other conditions, he heat pump is modeled with a small number of selected parameters. The values of the parameters are determined from the few measurements measured on-site during normal operation. A simulation program is developed to calculate cooling capacity and power consumption t any other operating conditions. The simulation results are in good agreement with the experiment. This study provides a method of an on-site performance diagnosis of an air source heat pump.

Application of Geophysical Methods to Cavity Detection at the Ground Subsidence Area (물리탐사 기술의 지반침하지역 공동탐지 적용성 연구)

  • Kim, Chang-Ryol;Kim, Jung-Ho;Park, Young-Soo;Park, Sam-Gyu;Yi, Myeong-Jong;Son, Jeong-Sul;Lim, Heong-Rae;Jeong, Ji-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.376-383
    • /
    • 2005
  • In this study, we conducted geophysical investigations for the organization of integrated geophysical methods to detect underground cavities of ground subsidence area at the field test site, located at Yongweol-ri, Muan-gun. We examined the applicability of geophysical methods such as electrical resistivity, electromagnetic, and microgravity to cavity detection with the aid of borehole survey results. Underground cavities are widely present within the limestone bedrock overlain by the alluvial deposits in the area of the test site where the ground subsidences have occurred in the past. The limestone cavities are mostly filled with groundwater and clays in the test site. Thus, cavities have low electrical resistivity and density compared to the surrounding host bedrock. The results of the study have shown that the zones of low resistivity and density correspond to the zones of the cavities identified in the boreholes at the site, and that the geophysical methods used are very effective to detect underground cavities. Furthermore, we could map the distribution of cavities more precisely with the test results incorporated from the various geophysical methods. It is also important to notice that the microgravity method is a very promising tool since it has rarely used for the cavity detection in korea. Beyond the investigation of underground cavities, the geophysical methods are required to provide useful information for the reinforcement design for the ground subsidence areas. It is, therefore, necessary to develop integrated geophysical technique incorporating different geophysical methods to precisely map underground cavities and image the subsurface of the ground subsidence areas.

  • PDF

Study of combinations of site operating states for multi-unit PSA

  • Yoo, Heejong;Jin, Kyungho;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3247-3255
    • /
    • 2021
  • As Probabilistic Safety Assessments (PSAs) are thoroughly conducted for the Site Operating States (SOSs) for a single unit, multi-unit Probabilistic Safety Assessments (MUPSAs) are ongoing worldwide to address new technical challenges or issues. In South Korea, the determination of the site operating states for a single site requires a logical approach with reasonable assumptions due to the fact that there are 4-8 operating units for each site. This paper suggests a simulation model that gives a reasonable expectation of the site operation states using the Monte-Carlo method as a stochastic approach and deterministic aspects such as operational policies. Statistical hypothesis tests were conducted so that the reliance of the simulation results can be guaranteed. In this study, 7 units of the Kori site were analysed as a case study. The result shows that the fraction of full power for all 7 units is nearly 0.45. For situations when more than two units are not in operation, the highest fraction combination was obtained for Plant Operation State (POS) 8, which is the stage of inspection and repairment. By entering various site operation scenarios, the simulation model can be used for the analysis of other site operation states.