Comparison of Contact Resistivity Measurements of Silver Paste for a Silicon Solar Cell Using TLM and CTLM (TLM 및 CTLM을 이용한 실리콘 태양전지 전면전극소재의 접촉 비저항 측정 비교연구)

  • Shin, Dong-Youn;Kim, Yu-Ri
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.539-545
    • /
    • 2014
  • Contact resistivity between silver electrodes and the emitter layer of a silicon solar cell wafer has been measured using either the circular transmission line method or the linear transmission line method. The circular transmission line method has an advantage over the linear transmission line method, in that it does not require an additional process for mesa etching to eliminate the leakage current. In contrast, the linear transmission line method has the advantage that its specimen can be acquired directly from a silicon solar cell. In this study, measured resistance data for the calculation of contact resistivity is compared for these two methods, and the mechanism by which the linear transmission line method can more realistically reflect the impact of the width and thickness of a silver electrode on contact resistivity is investigated.

Bioactivity Analysis of Curcuminoids from Turmeric using On-line Screening HPLC-ABTS (On-line Screening HPLC-ABTS를 이용한 강황으로부터 Curcuminoids의 생물활성 분석)

  • Choi, Sun Do
    • Journal of Applied Biological Chemistry
    • /
    • v.56 no.3
    • /
    • pp.137-139
    • /
    • 2013
  • Free radical scavengers in the bisdemethoxycurcumin (BDMC), demethoxycurcumin (DMC) and curcumin of turmeric (Curcuma longa) were screened, identified, quantified and isolation using coupled off-line-2,2'-azino-bis(3-ethylbenzthiazoline-6-sulphonic acid) (ABTS) and on-line screening high-performance liquid chromatography (HPLC)-ABTS assay. There was a very small margin of error between the off-line-ABTS method and the on-line screening HPLC-ABTS method.

On-line Measurement of Oil Consumption Using Oil Consumption Meter (오일소모 측정센서를 이용한 오일소모량의 실시간 측정)

  • 김기대;이재곤
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.688-694
    • /
    • 2002
  • Several methods were developed for on-line measuring oil consumption in gasoline engine using an oil consumption meter. The oil consumption meter indicates the oil quantity by real-time-measuring the oil level in the sump. In order to measure the oil consumption, the oil consumption meter proposed in this paper requires shorter time, less additional procedures, and shows better results than the traditional drain method. Under steady-state engine-operating conditions, the results obtained through the regression or the difference method show an good agreement with those through the drain method. Under transient engine-operating conditions, on the other hand, good results can be obtained through the reference method.

Effects of the Position of Potential Probe on Ground Resistance Measurements Using the Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전위보조전극 위치의 영향)

  • 이복희;어주홍;김성원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.97-104
    • /
    • 2001
  • The effects of the position of potential probe on the measurements of the ground resistance in the fa11-of-potential method are described. The ground resistance is theoretically calculated by applying the 61.8[%] rule, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring potential and current probes in on-site test might not be arranged on the straight line with adequate distance because there are building, roadblock construction and other establishments. Provided that the grounding electrode to be measured and the measuring potential probes are out of position on the straight line, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. In this work, measurements were focused on the grounding electrode system made by the ground rods of 2.4 m long. The measuring error was increased with increasing the angle which is made by the 3-points of the grounding electrode to be measured, the potential anti current probes, and it was a negative. That is, all of the measured ground resistances ware less than the true ground resistance.

  • PDF

A Preliminary Study on the In-line Concentration Measurement of Absorbent Solution (흡수용액의 In-line 농도측정을 위한 기초연구)

  • 민병혁;황덕용;정시영;구기갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.152-158
    • /
    • 2003
  • Titration method is one of the widely used methods for the concentration measurement of absorbent ammonia/water. However, this method is inconvenient because the solution should be extracted for the measurement. Moreover, significant error can be introduced by the evaporation of ammonia during the sampling and measuring procedure. In this study a reliable in-line concentration measurement method was proposed. To prove the validity of the concept, a measuring apparatus was designed, built, and tested with water. It is found that the location of flow inlet and exit is important in the measurement accuracy. The flow inlet and exit located in the middle of the test cell showed the best result. By the error analysis, it is expected that the ammonia concentration can be measured within the error of $\pm$0.18% assuming the error of 0.1 K in temperature measurement and 0.1 g in weight measurement.

A Study on the Compensation of Thermal Errors for Phase Measuring Profilometry (PMP 형상 측정법의 열 변위 보정에 관한 연구)

  • Kim, Gi-Seung;Park, Yoon-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.598-603
    • /
    • 2019
  • Three-dimensional shape measurement technology is used in various industries. Among them, optical three-dimensional shape measurement techniques based on the optical trigonometry are mainly used in the field of semiconductor product inspection, where large quantities of three-dimensional shape measurements are made daily in factories and fine measurements are also required. The light source and the drive circuit, which are components of three-dimensional measurement equipment based on this optical trigonometry, produce heat generated by prolonged operation, and may be exposed to conditions where the ambient temperature is not constant, resulting in temperature-induced measurement errors. In this study, the compensation method of the Thermal Errors for Phase Measuring Profilometry is proposed. Three-Dimensional Shape Measurement Equipment based on Phase Measuring Profilometry is implemented to measure the height of an object and ambient temperature for 10 Hours, and a regression line was obtained line by making simple linear regression using measured temperature and height values. This regression line was used to correct the error of the height measurement according to the temperature, and thermal error was from 139.88 um(Micrometer) to 13.12 um.

Measurement System for Phosphor Dispensing Shape of LED Chip Package Using Machine Vision (머신비전에 의한 LED Chip Package 형광물질 토출형상 측정)

  • Ha, Seok-Jae;Kim, Jong-Su;Cho, Myeong-Woo;Choi, Jong-Myung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2113-2120
    • /
    • 2013
  • In this study, an efficient machine vision based inspection system is developed for the in-line measurement of phosphor resin dispensing shapes on LED chip package. Since the phosphor resin (target material) has semitransparent characteristics, illuminated light beam is reflected from the bottom of the chip as well as from the surface. Since such phenomenon can deteriorate inspection reliability, a white LED and a 635nm laser slit beams are experimentally tested to decide suitable illumination optics. Also, specular and diffuse reflection methods are tested to decide suitable optical triangulation. As a result, it can be known that the combination of a white slit beam source and specular reflection method show the best inspection results. The Catmull-Rom spline interpolation is applied to the obtained data to form smoother surface. From the results, it can be conclude that the developed system can be sucessfully applied to the in-line inspection of LED chip packaging process.

Studies on Standardization of Licorice Based on Its Active Components with On-line HPLC Bioassay System (실시간 활성시스템을 접목한 감초의 유효성분에 대한 표준화 연구)

  • Hong, Jae Seung;Kang, Bum Gu;Jang, Young Soo;Kim, Seon Ha;Wang, Zhiqiang;Park, Yoon Ha;Park, Jong Hyuk;Lim, Soon Sung
    • Korean Journal of Plant Resources
    • /
    • v.27 no.5
    • /
    • pp.401-414
    • /
    • 2014
  • In an attempt to evaluate licorice quality based on its biological activity, we grafted an on-line high-performance liquid chromatography (HPLC) bioassay method into the previously established HPLC analysis method. The common antioxidant peaks in licorices of various origin were observed through an on-line HPLC/DPPH system leading to a decrease in absorbance at 517 nm for 2,2-diphenyl-1-picrylhydrazyl (DPPH). Among them, the licorice from Youngju possessed the highest activity. Therefore, three active standard compounds from the dehydroglyasperin C, dehydroglyasperin D, and isoangustone A, were isolated and elucidated by medium pressure liquid chromatography (MPLC) and instrumental analysis such as nuclear magnetic resonance (NMR), respectively. On-line HPLC/ABTS analysis method with the simultaneous determination of three standard compounds and their radical scavenging activity was established for the quality evaluation of licorices. 2,2'-azinobis-3-ethylbenzothiazoline-6-sulfonic acid radicals (ABTS) which is stable and effective was used in replace of DPPH. The radical scavenging activity of three standards is compared with that of Trolox, known as antioxidant, showing a negative peak with a decrease in absorbance at 734 nm for ABTS. This on-line HPLC/ABTS analysis method was validated for specificity, linearity, precision and accuracy in compliance with international conference on harmonization (ICH) guideline.

A Study on the Residual Stresses by the Hole Drilling Measuring in the WeldZone (용접부의 천공 측정법에 의한 잔류 응력에 관한 연구)

  • NamKoong, Chai-Kwan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.3
    • /
    • pp.115-121
    • /
    • 2008
  • A knowloedge of the residual stress distribution at circumferential welds can increase the prediction accuracy of a fracture assessment in pipe lines. In this study, in order to predict the residual stress distribution in the circumferential butt-welded pipes were measured, using the hole-drilling strain gauge method. Their practical applications were performed in to two kinds of pipes. As the results, the following characteristics were found. On the inner surface of pipes, the circumferential and axial residual stresses were both tensile near the center line of welding and both of them changed from tensile to compressive as the distance from the center line increased. On the outer surface, however, the circumferential residual stress was shown to be tensile wile the axial residual stress was compressive near the center line of welding, and later they were revered at the region far away from the centerline.

W-Band Permittivity Measurements Using a Free-Space Material Measurement Technique (자유공간 물질상수 측정법을 이용한 W-Band 유전율 측정)

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Cho, Chihyun;Kim, Dae-Chan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.253-258
    • /
    • 2013
  • In this paper, a free-space material measurement technique is discussed in W-band(75~110 GHz). For the accurate measurement of S-parameters of an MUT(Material Under Test) in free space, a W-band quasi-optical free-space material measurement system, less affected by the measurement environments, is discussed, and GRL(Gated Reflect Line) method for calibrating the measurement system is described. Proposed technique is verified for 'Air' and measurement results for arystal plates of thickness 1.1 mm, 2 mm, 2.75 mm and 5 mm are also shown.