Flexural Capacity Evaluation of High-strength New-shape Composite Pile (S-Pile) for the Soldier Pile in the C.I.P Method (주열식공법 엄지말뚝을 위한 고강도 신형상 합성파일 (S-Pile)의 휨성능 평가)

  • Lee, Kyung-koo;Kim, Dae-Hee;Joo, Eun-Hee;Kim, Young-Gi;Kim, Bong-Chan;Lee, Ji-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.185-186
    • /
    • 2021
  • In Korea, many buildings are built with underground spaces and cast-in-place pile method is mostly applied in the temporary retaining walls for the underground space construction. A H-shaped steel section is generally embedded in the soldier pile in the C.I.P method. In this study, a new and economical section with high strength steel replacing the H-shaped section was proposed and its flexural capacity was evaluated experimentally. The new section is the concrete-filled composite section with pentagonal thin plate and thick flange plate. Test results showed that the proposed section has an excellent flexural strength and ductility.

  • PDF

Differences in Flood-Stress Tolerance among Sprout Soybean Cultivars

  • Cho, Jin-Woong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.58 no.2
    • /
    • pp.190-195
    • /
    • 2013
  • In this study, the response of 22 soybean cultivar sprouts to flooding stress was investigated. After sprouts were subjected to flooding stress for 10 days at the V4-V5 growth stages, their dry weights were compared. All plants were kept in a greenhouse under natural light conditions, an average daytime temperature of $35.6{\pm}5.3^{\circ}C$ and an average nighttime temperature of $18.2{\pm}1.7^{\circ}C$. Soybeans were grown in a concrete bed filled with silt loam soil. Subjecting plants to flooding stress resulted in a large reduction in plant dry weight, plant height, number of nodes, and number of leaves. Cultivars differed significantly in their responses to flooding stress, as indicated by these characteristics (p<0.05). Soybean cultivars were classified into three groups based on their degree of flood tolerance: strong, moderate, and weak. Hannamkong, Namhaekong, Sobaegnamulkong, and Sorogkong had strong tolerance for flood conditions. Tawonkong, Pureunkong, Eunhakong, Myeongjunamulkong, Doremikong, Saebyeolkong, Paldokong, Sowonkong, Pungsannamulkong, Dagikong, Dachaekong, and Anpyeongkong had weak tolerance for flood conditions.

Spatial mechanical behaviors of long-span V-shape rigid frame composite arch bridges

  • Gou, Hongye;Pu, Qianhui;Wang, Junming;Chen, Zeyu;Qin, Shiqiang
    • Structural Engineering and Mechanics
    • /
    • v.47 no.1
    • /
    • pp.59-73
    • /
    • 2013
  • The Xiaolan channel super large bridge is unique in style and with greatest span in the world with a total length of 7686.57 m. The main bridge with spans arranged as 100m+220m+100m is a combined structure composed of prestressed concrete V-shape rigid frame and concrete-filled steel tubular flexible arch. First of all, the author compiles APDL command flow program by using the unit birth-death technique and establishes simulation calculation model in the whole construction process. The creep characteristics of concrete are also taken into account. The force ratio of the suspender, arch and beam is discussed. The authors conduct studies on the three-plate webs's rule of shear stress distribution, the box girder's longitudinal bending normal stress on every construction stage, meanwhile the distribution law of longitudinal bending normal stress and transverse bending normal stress of completed bridge's box girder. Results show that, as a new combined bridge, it is featured by: Girder and arch resist forces together; Moment effects of the structure are mainly presented as compressed arch and tensioned girder; The bridge type brings the girder and arch on resisting forces into full play; Great in vertical stiffness and slender in appearance.

Structural Design of Mid-Story Isolated High-Rise Building - Roppongi Grand Tower

  • Nakamizo, Daiki;Koitabashi, Yuichi
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.3
    • /
    • pp.233-242
    • /
    • 2018
  • Since the response reduction effect on over 200-meter-tall resulting from the seismic isolation system is smaller in general than low-rise and mid-rise buildings, mid-story isolated buildings are considered to reduce the response in the upper part above the isolation story, however, in many cases, the acceleration response just below the isolation story is likely to be the largest. This paper presents the structural design schemes, the design of the main structural frames, and the constructions of a 230-meter-tall super high-rise building with mid-story isolation mechanism integrated in Roppongi, Tokyo. Moreover, this paper shows how the architectural and structural design for integrating a mid-story isolation system in a super high-rise building has been conducted and what solutions have been derived in this project. The realization of this building indicates new possibilities for mid-story isolation design for super high-rise buildings.

Interfacial Stress Concentrations of Vertical Through-plate to H-beam Connections in CFT Column

  • Choi, Insub;Chang, HakJong;Kim, JunHee
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.4
    • /
    • pp.325-334
    • /
    • 2020
  • This paper aims to evaluate the interfacial stress concentrations on connection between vertical through-plate and H-beam in CFT column. Full-scale experiments were performed on three specimens with varying thickness of the vertical through-plate to investigate the interfacial stress concentration factor in the connections. The specimens underwent brittle failure at the location where the steel beam is connected to the vertical through-plate before the steel beam reached its plastic moment. The strain data of the part were analyzed, and the sectional analyses were conducted to determine appropriate residual stress models. In addition, the stress concentration factor was quantified by comparing the analytical local behavior in which the stress concentration is not reflected and the experimental data reflecting the stress concentration. The results showed that the maximum reduction of the stress concentration factor due to an increase in the thickness of the vertical through-plate is 50.3%.

Experimental Study of the Fire Behavior of CFT Columns in Relation to the Sectional Shape & Size (단면형상 및 크기에 따른 콘크리트 충전강관(CFT) 기둥의 화재거동에 관한 실험적 연구)

  • Cho, Bum-Yean;Kim, Heung-Youl;Kwon, Ki-Seok;Yang, Seung-Cho
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.9-16
    • /
    • 2017
  • In this study, fire resistance tests were conducted to evaluate the fire resistance performance of unprotected and non-welded CFT columns in relation to the shape and size of cross-sections. Unprotected slot-type CFT columns which were ${\square}300$ and ${\square}500$ in dimensions resisted fire for 125 minutes and more than 180 minutes, respectively. Strain analysis showed that slot-type CFT columns were more ductile than welded CFT columns. The temperatures of central parts measured when welded CFT columns and slot-type CFT columns had lost fire resistance performance were higher in the former than the latter. Therefore, slot connection does not a great influence on the temperatures inside the concrete.

The First Performance-based Structural Fire Design for Office Building in Korea

  • Min Jae Park
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.235-239
    • /
    • 2023
  • In this study, the fire resistance performance of the concrete-filled steel tube (CFT) columns and thin steel-plate composite (TSC) beams installed at a 20-story office building were designed using a performance-based structural fire design. Because of the lack of any specific provisions in the building code and guidelines for structural engineers about the performance-based approach, the only prescriptive approach has been selected for designing fire-resistant structures in Korea. To evaluate the fire resistance performance of the CFT columns and TSC beams, finite element analysis verified by the experimental results studied by several researchers was conducted with ABAQUS. From the fire scenario, the temperature distributions of the CFT columns and TSC beams were found via finite element analysis and the behaviors of the CFT columns and TSC beams were investigated in the structural field based on the temperature distribution.

Effect of polyolefin fibers on the permeability of cement-based composites

  • Hsu, Hui-Mi;Lin, Wei-Ting;Cheng, An
    • Computers and Concrete
    • /
    • v.9 no.6
    • /
    • pp.457-467
    • /
    • 2012
  • This study evaluates the permeability of cement-based composites, which are a mix of polyolefin fibers and silica fume. Test results indicate that permeability increases as the water/cementitious ratio increases. Silica fume in cement-based composites produced hydrated calcium silicate and filled the pores. However, permeability decreased as the addition of silica fume increased. Specimens containing polyolefin fibers also provided higher permeability resistance. The polyolefin fiber length did not have a significant effect on permeability. The decrease in the permeability is mainly due to the addition of silica fume and lower water/cementitious ratio. Addition of fibers marginally decreases the permeability. Incorporating polyolefin fiber and silica fume in composites achieved more significant decreases in permeability. The correlated test results reveal the interrelationship between them.

An Analytic study on the bond of the contact surface in CFT tubular column (중심축하중을 받는 CFT 합성기둥의 접촉면 부착에 관한 해석적 연구)

  • Ye, Sang-Min;Lee, Soo-Young;Kim, Yun-Tae;Park, Seoug-Moo
    • Proceeding of KASS Symposium
    • /
    • 2005.05a
    • /
    • pp.205-212
    • /
    • 2005
  • In order for utilization of the concrete filled tubular, It Is necessary to scrutinize interfacial characteristics between heterogeneous materials, and be performed to various analytical studies on the composite structure. In this paper, this analytic study is carried on using ABAQUS Package/ Version 5.8-1, and the variables aye the relations between the coefficient of friction and the contact pressure for analyzing the behavior on the contact surface, through modifying the analytic methods and improving some problems. It is used to subdivided analytical methods in this research which categorize into four regions and can obtain closer effect for the bond behavior. Four categories compose of the chemical bond and mechanical bond legions replaced the full-interaction before yielding, and the pure friction and moving-down regions after yielding.

  • PDF

A parametric investigation on the hysteretic behaviour of CFT column to steel beam connections

  • Esfandyary, R.;Razzaghi, M.S.;Eslami, A.
    • Structural Engineering and Mechanics
    • /
    • v.55 no.1
    • /
    • pp.205-228
    • /
    • 2015
  • The results of a numerical investigation pertaining to the hysteretic behaviour of concrete filled steel tubular (CFT) column to I-beam connections are discussed in detail. Following the verification of the numerical results against the available experimental tests, the nonlinear finite element (FE) analysis was implemented to evaluate the effects of different parameters including the column axial load, beam lateral support, shape and arrangement of stiffeners, stiffness of T-stiffeners, and the number of shear stiffeners. Pursuing this objective, an external CFT column to beam connection, tested previously, was selected as the case-study. The lateral forces on the structure were simulated, albeit approximately, using an incremental cyclic loading reversal applied at the beam tip. The results were compared in terms of hysteretic load-displacement curves, stress distributions in connection, strength, rotation, and energy dissipation capacity. It was shown that external T-stiffeners combined with internal shear stiffeners play an important role in the hysteretic performance of CFT columns to I-beam connections.