• Title/Summary/Keyword: in-filled concrete

Search Result 890, Processing Time 0.029 seconds

Neutron Reflecting Effects by Water and Concrete (물과 콘크리트에 의한 중성자(中性子)의 반사효과(反射效果))

  • Min, Duck-Kee;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.8 no.1
    • /
    • pp.33-37
    • /
    • 1983
  • Neutron reflecting effects in terms of effective multiplication factor have been calculated with varying water or concrete thickness, and gap distance between concrete reflector and a fissile solution system. A numerical calculation of effective multiplication factors has been carried out by using the discrete ordinates method with the help of the computer code, ANISN. It is revealed that the reflecting .effect by thin concrete is lower than that of the identical thickness of water while the effect by thick water is low compared to that of the identical thickness of concrete. It seems that the effective multiplication factors are first decreasing rapidly with gap distance, which is filled with water, between concrete reflector and the fissile solution system, and then decrease slowly over the distance of about 15cm.

  • PDF

Bond behavior between circular steel tube and high-strength concrete after elevated temperatures

  • Ji, Zhou;Zongping, Chen;Maogen, Ban;Yunsheng, Pang
    • Structural Engineering and Mechanics
    • /
    • v.84 no.5
    • /
    • pp.575-590
    • /
    • 2022
  • In this paper, bond-slip behavior of high strength concrete filled circular steel tube (HSCFCST) after elevated temperatures treatment was studied. 17 specimens were designed for push-out test. The influence was discussed as following parameters: (a) concrete strength, (b) constant temperature, and (c) bond length. The results showed that (1) after elevated temperatures treatment, the bond strength of the HSCFCST specimens increased first and then decreased with temperature rising; (2) the bond strength increased with the increase of concrete strength at room temperature, while the influence subsided after elevated temperatures treatment; (3) the strain of the circular steel tube was distributed exponentially along its length, the stress changed from exponential distribution to uniform distribution with the increase of load; (4) the bond damage process was postponed with the increase of constant temperature; and (5) the energy consumption capacity of the bonding interface increased with the rise of concrete strength and constant temperature. Moreover, computational formulas of ultimate and residual bond strength were obtained by regression, and the bond-slip constitutive models of HSCFCSTs after elevated temperatures was established.

Proposal of Stress-Strain Relations Considering Confined Effects for Various Composite Columns (합성형태에 따른 콘크리트 구속효과를 고려한 응력-변형률 관계식의 제안)

  • Park, Kuk Dong;Hwang, Won Sub;Yoon, Hee Taek;Sun, Woo Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.265-275
    • /
    • 2010
  • Concrete filled steel tube and concrete encased steel tube columns are expected to have confined effects of concrete by steel and reinforced effects of local buckling by concrete. On the basis of confined state concrete models of previous researches, stress-strain and load-displacement relations of RC, CFT and CET columns are analyzed by steel ratio. After comparing analysis results with experimental results, Modified stress-strain relations are derived through evaluation the influence upon confined effects of concrete in each cases. Also, the modified stress-strain models are carried out to be compared with specified strength of various countries.

An Experimental Study on The Behavior of Reinforced Concrete Beams with Poor-Compacted Concrete in Tensile Steel Zone (인장철근영역 콘크리트 다짐불량에 따른 철근콘크리트 보의 거동)

  • Park, Hoon-Gyu;An, Young-Ki;Jang, Il-Young;Park, Byung-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.143-150
    • /
    • 2008
  • There is possibility of poor-state concrete filling condition due to segregation of aggregate and paste in reinforced concrete structure. This study was conducted to evaluate the flexural and shear behavior of reinforced concrete beams with different concrete filling conditions. Different concrete filling conditions were intentionally made such that the specimens was soundly cast to obtain the perfect concrete filling condition and cast in such a way that up to the longitudinal tensile reinforcement from the top, good concrete was filled while poor concrete was poured for the bottom part to simulate the poor strength, workability and unsatisfactory compaction. The test results indicate that have no effect of concrete filling conditions on the yielding strength of structures. But, have a great influence on the flexural ductility and shear capacity of structures.

The prevention of Fault by Analyzing the Gas in Oil of Oil-Filled Cable System (OF 케이블 절연유 가스분석을 통한 고장예방)

  • Kim, Du-Jin;Kim, Jae-Seung;Yoon, Jong-Keon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.444-445
    • /
    • 2008
  • This paper reviews the known techniques for diagnosing the condition of OF cable system and improving the service reliability. These tests are periodically achieved and intended to provide indications that the insulation system has deteriorated. One of these tests is analyzing the gas in oil on Oil-filled cable that is well known and widely accepted method. In this paper, this method of analysis and the relevant measurement standards overview and the concrete example of preventing fault incidence by performing this test is introduced.

  • PDF

An Experimental Study on Column Penetration Joint of RC Column-Steel Beam (기둥관통형 RC 기둥-철골 보 접합부에 관한 실험적 연구)

  • 김승훈;한상환;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.475-480
    • /
    • 1998
  • The composite framed structures, consisting of RC columns and steel beams more popular in korea because of their efficiency and quality. However the force transfer mechanisms between the column and beam may by very complicated since the materials of columns and beams are different. This study develops "the column penetration joint" which the web of steel beam doesn't penetrate and which could improve the strength, deformation, and energy dissipation capacities compared to existing composite joints. It is the concrete-filled square tube joint with the exterior diaphragms and the cruciform stiffening plates. This study evaluated the strength of RC column penetration to steel beam connection by analyzing the results of partial experiments, and reviewed the applicability the strength formula through the comparison of tested results of joint experiment.

  • PDF

Application for Environment-friendly Retaining Wall Method Composed with Permanent Ground Anchor and Vertical Precast Panel in Cutting Slope Area (영구앵커와 연직 프리캐스트패널을 사용한 절토사면 친환경옹벽공법의 적용사례)

  • Nam, Hong-Ki;Jung, Hong-Seop
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.87-96
    • /
    • 2010
  • PAP method is a combined measures which consist a anchored retaining wall method with permanent ground anchors and vertical precast concrete panels, step by step on the slope surface. And soil is back filled between slope and vertical precast panels. Therefore, this method is more effective than any other ground anchor reinforcing methods of slope stability, for example cross type concrete block ground anchor or buttress concrete block ground anchor method. Because of increasing effective anchor force and green tree planting.

  • PDF

Static Tests of ㄱ Type Perfobond Rib Shear Connectors when using Steel Tube (원형강관에 부착된 ㄱ형 perfobond 리브 전단연결재의 정적실험)

  • Lee Heung-Su;Chung Chul-Hun;Choi Wae-Ho;Kim Seok-Ki;You Sung-Kun;Kim Young-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.778-781
    • /
    • 2004
  • This paper summarizes the results of push-out test specimens with a new type of shear connector called ㄱ type perfobond rib. This connector is a flat steel plate with a number of holes punched through and strengthen rib's head part. According to experiment result, ㄱ type perfobond rib shear connector appeared that resistance force is increased than stud shear connector by $108\%$ and perfobond rib shear connector by $26\%$. The results obtained indicate that the perfobond rib connector is a viable alternative to the headed studs. An appreciable improvement in the shear capacity of the connection was observed when additional reinforcing bars were passed through the perfobond rib holes. For composite beams with concrete filled steel tubes, ㄱ type perfobond shear connectors exhibit adequate ductility and substantially higher capacities.

  • PDF

Effect of crumb rubber on compressive behaviour of CRCFST stub columns

  • Liu, Dawei;Liang, Jiongfeng;Zhang, Guangwu;Wang, Jianbao
    • Computers and Concrete
    • /
    • v.25 no.3
    • /
    • pp.267-272
    • /
    • 2020
  • This paper investigates the effect of crumb rubber (CR) on compressive behaviour of crumb rubber concrete filled steel tube (CRCFST) stub columns. Therefore, experiments on 16 stub columns subjected to axial loading are carried out. The results show that the failure modes of CRCFST stub columns with different CR replacement ratios and CR size are similar, manifested the buckling of the outer steel tube. The axial bearing capacity and stiffness both decrease with an increase in CR replacement ratio, and with decreasing CR size.

Sustainable self compacting acid and sulphate resistance RAC by two stage mixing approaches

  • Rajhans, Puja;Kisku, Nishikant;Nayak, Sanket;Panda, Sarat Kumar
    • Advances in concrete construction
    • /
    • v.9 no.1
    • /
    • pp.55-70
    • /
    • 2020
  • In this research article, acid resistance, sulphate resistance and sorptivity of self compacted concrete (SCC) prepared from C&D waste have been discussed. To improve the above properties of self compacted recycled aggregate concrete (SCRAC) along with mechanical and durability properties, different two stage mixing approaches (TSMA and TSMAsfc) were followed. In the proposed two stage mixing approach (TSMAsfc), silica fume, a proportional amount of cement and a proportional amount of water were mixed in premix stage which fills the pores and cracks of recycled aggregate concrete (RAC). The concrete specimen prepared using above mixing approaches were immersed in 1% concentration of sulphuric acid (H2SO4) and magnesium sulphate (MgSO4) solution for 28, 90 and 180 days for evaluating the acid resistance of SCRAC. Experimental results concluded that the proposed two stage mixing approach (TSMAsfc) is most suitable for acid resistance and sulphate resistance in terms of weight loss and strength loss due to the elimination of pores and cracks in the interfacial transition zone (ITZ). In modified two stage mixing approach, the pores and cracks of recycled concrete aggregate (RCA) were filled up and make ITZs of SCRAC stronger. Microstructure analysis was carried out to justify the reason of improvement of ITZs by electron probe micro analyser (EPMA) analysis. X-ray mapping was also done to know the presence of strength contributing elements presents in the concrete sample. It was established that SCRAC with modified mixing approach have shown improved results in terms of acid resistance, sulphate resistance, sorptivity and mechanical properties.