• Title/Summary/Keyword: in-circuit test

Search Result 1,629, Processing Time 0.029 seconds

A Study of the Life Characteristic of Hydraulic Hose Assembly by Adopting Temperature-Nonthermal Acceleration Model (온도.비열 가속모형을 적용한 유압호스조립체 수명특성 연구)

  • Lee, Gi-Chun;Kim, Hyoung-Eui;Cho, You-Hee;Sim, Sung-Bo;Kim, Jae-Hoon
    • Journal of Applied Reliability
    • /
    • v.11 no.3
    • /
    • pp.235-244
    • /
    • 2011
  • Hydraulic hose assemblies deliver a fluid power in various oil pressure equipment such as construction machinery, automobile, aircraft, industrial machinery, machine tools and machinery for ships. Also, they are widely used as pipes in oil pressure circuit. When we estimate their lifetime, it is essential to conduct an accelerated life test by choosing the factor that suits the usage condition of the test object since traditional test method for estimating lifetime under the influence of various external factors incurs hardship in terms of time and expenses. The objective of this study is to propose an acceleration model that takes both temperature and pressure without flexing condition into consideration. The lifetime is estimated by applying the proposed temperature-nonthermal acceleration model to the test data. And we compare the proposed temperature-nonthermal acceleration model and the accelerated life equation suggested by John(1994).

Analysis of arc-energy with joint box type through a field test (인공지락 실증시험을 통한 접속함 종류별 아크에너지 해석)

  • Kang, J.W.;Jang, T.I.;Hong, D.S.;Lee, D.I.;Kim, H.D.;Oh, C.H.;Lim, H.E.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.715-717
    • /
    • 2005
  • This paper analyses the arc-energy with joint box type through a field test on underground power OF cable. In order to obtain the data, the actual proof test using short-circuit generation for real scale power transmission tunnel carried out. This paper is expected to contribute the fire accident prevention on underground power cable systems and the believability improvement of electric power facilities.

  • PDF

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

Reliability Evaluation of Silver Patterns Using Ink-jet Printing Technology (잉크젯 기술을 이용하여 인쇄된 실버 패턴의 신뢰성 분석)

  • Shin, Kwon-Yong;Kim, Myong-Ki;Lee, Sang-Ho;Hwang, Jun-Young;Kang, Heui-Seok;Kang, Kyung-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1450-1451
    • /
    • 2008
  • To investigate the reliability of the conductive lines patterned by ink-jet printing, we evaluated the reliability of the ink-jet printed silver (Ag) patterns according to the guide lines built up as assessments methods in the production of conventional rigid printed circuit boards. The assessment methods include the uniformity of line width and space, adhesive strength, dielectric withstand, solder float, thermal shock test and pressure cooker test (PCT). To prepare assesment vehicles, different regular test patterns were created by Ag ink-jet printing on the same polyimide substrate for each of assessment methods.

  • PDF

Cargo Inspection System Design and Boundary-Scan Test (화물 검색시스템 구현 및 Boundary_Scan Test)

  • Kim, Bong-Su;Kim, In-Su;Yoo, Sun-Won;Kim, Sung-Won;Lee, Sun-Wha;Yi, Yun;Han, Bum-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.197-200
    • /
    • 2002
  • We newly developed the procedures of X-ray Cargo inspection system with acquisition of multi-channel data, analog to digital converter and post logic circuit which is controlled by the FPGA. The IEEE1149.1 standard defines a four-wire serial interface(a fifth wire is optional)to access complex integrated circuits(ICs) such as PLD. This paper describes that Boundary_Scan test method applied to our home made cargo inspection system.

  • PDF

The transient grounding impedance measurment of large grid grounding electrodes (대규모 그리드 접지전극의 과도접지임피던스의 측정)

  • Jeon, Byung-Wook;Lee, Su-Bong;Li, Feng;Lee, Seung-Ju;Jung, Dong-Cheol;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.69-72
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of large grid grounding system associated with the injection point of impulse current The measurement methods consider two possible errors in the grounding-system impedances: (1) ground mutual resistance due to current flow through ground from the ground electrode to be measured to the current auxiliary, (2) ac mutual coupling between the current test lead and the potential test lead The test circuit was set to reduce the error factors. The transient grounding impedance depends on the rise time and injection point of impulse current It is effective that grounding conductor is connected to the center of the large grid grounding system.

  • PDF

A Study on the Reliability Assessment of the Mould Type Combined Transformer (건식 계기용 변압변류기의 신뢰성 평가에 관한 연구)

  • Kim, I.S.;Kim, M.K.;Huh, D.H.;Koo, J.Y.;Kong, Y.S.;Lee, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.216-217
    • /
    • 2007
  • This paper represents the reliability assessment on the mould type combined transformer used in the distribution system by electrical tests. For the reliability assessment, we had tested lightning impulse test, short-circuit withstand capability test, electrical accelerated life test and so on to the mould type combined transformer of Young-Hwa Industrial Electric Co., Ltd.

  • PDF

A Study on the Test Device for Improving Test Speed and Repeat Precision of Semiconductor Test Socket (반도체 테스트 소켓의 검사속도 및 반복 정밀도 개선형 검사장치에 관한 연구)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.327-332
    • /
    • 2021
  • At the package level, semiconductor reliability inspections involves mounting a semiconductor chip package on a test socket. The form of the test socket is basically determined by the form of the chip package. It also acts as a medium to connect with test equipment through mechanical contact of the leads and socket leads in the chip package, and it minimizes signal loss in a signal transmission process so that an inspection signal can be delivered well to the semiconductor. In this study, a technique was applied to examine the interdependence of adjacent electrical transfer routes and the structure of adjacent electrical transfer paths. The goal was to enable short-circuit testing of fewer than 100 silicon test sockets through a single interface for life tests and precision measurements. The test results of the developed device show a test precision of 99% or more and a simultaneous test speed characteristic of 0.66 sec or less.

Effect of Nitrogen Ion Implantation on Corrosion Resistance of Biocompatible Ti Implant (질소이온의 주입이 생체안전성 티타늄임플란트의 내식성에 미치는 영향)

  • 최종운;손선희
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.134-139
    • /
    • 1999
  • In this study, PSII(plasma source ion implantation) was used to improve the biocompatibility of bone-anchored Ti implant. According to potentiodynamic anodic polarization test in deaerated Hank's solution, open circuit potential of ion implanted specimens were increased compare to that of unimplanted specimen ; besides, passive current density and critical anodic current density of ion implanted specimens were lower than unimplanted specimen.

  • PDF

Reliability Assessment of Epoxy Bushing used for VCB rated 38kV (38kV VCB용 에폭시부싱 신뢰성평가)

  • Kim, M.K.;Huh, D.H.;Kim, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.133-134
    • /
    • 2008
  • This paper describes a testing method to assess the reliability of the epoxy bushing used for the vacuum circuit breaker(VCB). Especially, in order to show the long-term durability of epoxy bushing in a short testing duration, the extremely accelerated electric stress applying test plan was adopted.

  • PDF