• Title/Summary/Keyword: in-circuit test

Search Result 1,629, Processing Time 0.039 seconds

A Development of Eddy Current Testing System for Steam Generators Inspection in Nuclear Power Plants (원전 증기발생기 와전류검사 시스템 개발)

  • Moon, Gyoon-Young;Cho, Chan-Hee;Yoo, Hyun-Joo;Lee, Tae-Hun;Cho, Yong-Bae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.40-47
    • /
    • 2013
  • The capacity factor of nuclear power plant in Korea is the highest level in the world. However, the integrity assessment of nuclear power plant is depended on foreign country. Especially, most eddy current testing systems for inspecting steam generators in nuclear power plant are currently imported from USA, Canada, and so on. Therefore, the eddy current testing system can react more active and adaptive from economic and managerial standpoint for actual nuclear power plants in Korea is required. In this paper, an eddy current testing system for inspecting steam generators in nuclear power plants is introduced. Frequency generator, analog circuit, analog digital converter circuit, and digital control circuit are composed in eddy current testing system. A benchmarking of acquisition system and acquisition software, eddynet 11i made by Zetec, and modifications are carried out based on the test environment of Korea nuclear power plants. Finally, all eddy current apparatus are integrated to inspect steam generator tubes in nuclear power plants.

Analysis of Voltage Stress in Stator Windings of IGBT PWM Inverter-Fed Induction Motor Systems

  • Hwang Don-Ha;Lee Ki-Chang;Jeon Jeong-Woo;Kim Yong-Joo;Lee In-Woo;Kim Dong-Hee
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.1
    • /
    • pp.43-49
    • /
    • 2005
  • The high rate of voltage rise (dv/dt) in motor terminals caused by high-frequency switching and impedance mismatches between inverter and motor are known as the primary causes of irregular voltage distributions and insulation breakdowns on stator windings in IGBT PWM inverter-driven induction motors. In this paper, voltage distributions in the stator windings of an induction motor driven by an IGBT PWM inverter are studied. To analyze the irregular voltages of stator windings, high frequency parameters are derived from the finite element (FE) analysis of stator slots. An equivalent circuit composed of distributed capacitances, inductance, and resistance is derived from these parameters. This equivalent circuit is then used for simulation in order to predict the voltage distributions among the turns and coils. The effects of various rising times in motor terminal voltages and cable lengths on the stator voltage distribution are also presented. For a comparison with simulations, an induction motor with taps in the stator turns was made and driven by a variable-rising time switching surge generator. The test results are shown.

A Study on the Corrosion Control of Glass Flake Lining for Mild Steel in Marine Environment (해양환경 중에서 Glass Flake 라이닝 강재의 부식방지에 관한 연구)

  • Lim, Uh-Joh;Kim, Seong-Hoon
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.12 no.2
    • /
    • pp.164-175
    • /
    • 2000
  • Port facilities and marine structures used in marine environment were encountered to corrosion damages because of the influence of Cl-. Generally, to protect these accidents, anti-corrosion paint and epoxy coating have been used. But they were still remained erosion-corrosion damage like impingement erosion, cavitation erosion and deposit attack. It is necessary to develope the new composite lining material in order to protective those corrosion damages. In this paper, polyester glass flake, vinylester glass flake lining and epoxy coating for SS400 were investigated by the electrochemical polarization test and the impingement-cavitation erosion test for corrosion behaviour under the sea water. The main results obtained are as follows ; 1) Epoxy coating appear potentiodynamic polarization behaviour, but polyester glass flake and vinylester glass flake lining do not appear potentiodynamic polarization behaviour. 2) Open circuit potential of polyester glass flake lining is more noble than that of epoxy coating and corrosion current density of polyester glass flake lining is less drained than that of epoxy coating in sea water. 3) Open circuit potential of vinylester glass flake lining is more noble than that of polyester glass flake lining and corrosion current density of vinylester glass flake lining is less drained than that of polyester glass flake lining in the sea water.

  • PDF

Design for improving the impact resistance of a vehicle equipped with the circuit card assembly (비행체 탑재 회로카드 조립체의 내충격 향상을 위한 설계)

  • Lee, Chang-Min;Kang, Dong-Suk;Shin, Young-Hoon;Lee, Ki-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.48-53
    • /
    • 2014
  • Rocket, held using the CCA for the mission, a plurality of recording devices, and navigation equipment. In case of a projectile which is entered the water after fired into the air, after performing stages and fairing separated in flight to enter the underwater. It is caused by the explosion of gunpowder mainly, vibration phenomenon of a large transition is induced structurally very, also on entering the water, have a significant shock structurally separated. If shock is transmitted directly to the CCA through the body, it can be caused malfunction of payloads, resulting in failure of the mission of the projectile. In order to ensure the stability against shock, in this paper, Calculating a target resonacne frequency of the CCA, and verified through modal test and analysis. Maximum acceleration position of CCA is checked by SRS analysis. In addition, effectiveness of shock isolation system through shock analysis.

  • PDF

Implementation of Integration Control System Based on Smart for Moving Welfare Medical Device Disinfection (이동식 복지용구 소독을 위한 스마트 기반의 통합제어시스템 구현)

  • Hwang, Gi-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2251-2258
    • /
    • 2014
  • In this paper, an integrated control system for removable welfare equipment disinfection is implemented. The integrated control system consisted of a hydrogen peroxide vapor supply control circuit, a sterilization chamber control circuit using low vacuum, and a washing control circuit using microbubble. A Smart-phone based remote control and monitoring system is implemented to monitor the operating status and communication status for the integrated control system. An experiment is set up to evaluate the performance of the integrated control system. The experiment result confirms that signal and operation status can transmit and receive within the control circuit. The integrated control system shows good performance in terms of sensor interface, communication state and control. In future research, the proposed control system should deploy to an actual system for trial test to prove its performance.

A Study on the outside rotor type double squirrel cage Induction motor (외측회전형 이중 농형 유도전동기에 관한 연구)

  • 김현수;배철오;안병원
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.776-782
    • /
    • 2003
  • This paper describes a newly developed double squirrel cage induction motor in which the rotor is located outside the stator. The outside rotor type brushless dc motor has been used for VTR's head drum and PC's cooling fan, but this kind of induction motor has not been developed yet. The parameters of outside rotor type induction motor were measured from the locked rotor test and no load test. It is possible to determine the parameters which are presented in the steady-state equivalent-circuit of the outside rotor type induction motor. Load test of induction motor was carried out using a dynamometer. For the characteristics of torque, efficiency, power factor and output. the developed double squirrel cage induction motor is compared with the ordinary induction motor It is believed that the results of this paper can be used for the development of the outside rotor type induction motor.

Review of the tracebility of ERA PD measuring system in test laboratory (시험소 부분방전 측정시스템(ERA)의 소급성검토)

  • Heo, J.C.;Kang, Y.S.;Kim, W.Y.;Oh, C.S.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1969-1971
    • /
    • 2004
  • For evaluation of partial discharge performances of electrical power appratus such as Insulator, circuit breaker and transformer and so on, Partial discharge measuring system(ERA) consisted of PD detector including amplifier, coupling capacitor, PD calibrator and voltage divider are used PD measuring system is very important factor which affect the test result and show reliability of test result in test laboratory, In this paper, we describe tracebility and uncertainty of PD measuring system in test laboratory based on IEC 60270.

  • PDF

온도-비열 가속모형을 적용한 유압호스 조립체의 수명특성 연구

  • Lee, Gi-Cheon;Kim, Hyeong-Ui;Jo, Yu-Hui;Sim, Seong-Bo
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2011.06a
    • /
    • pp.281-288
    • /
    • 2011
  • Hydraulic hose assemblies deliver a fluid power in various oil pressure equipments such as construction machinery, automobile, aircraft, industrial machinery, machine tools, and machinery for ships, or they are used as pipes in oil pressure circuit. However, as the traditional measure for estimating life under the influence of various external factors incurs hardship in terms of time and expenses, it is essential to take accelerated life test by choosing the factor that suits the usage condition of the test object. The objective of the this study is to propose a acceleration model that takes both temperature and pressure without flexing condition into consideration. The life that is calculated by the equation for evaluating life and the test data show similar slopes as a result of comparing and analyzing the equation for evaluating life that is obtained in this research and the test data, which illustrates that they estimate life similarly, and the proposed equation is proved to be an accelerated life equation that presents the test results.

  • PDF

A study on Identifying Undetectable Faults Using Uninitializable Flip-Flops (초기화가 불가능한 풀립플롭을 이용한 시험 불가능 고장 검출에 관한 연구)

  • Lee, Jae-Hun;Jo, Jin-U
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.5
    • /
    • pp.1371-1379
    • /
    • 1997
  • Undetectable faults in a digital circuit are faults that no input patterms can detect.Identifying these faults in test geferation process is very time- consuming especially for sequential circuits .In this paper we present a new algorithm to identify unedtectable faults in sequential cirouits .In the alorithm. we identify uninitializable fip-flops and then, faults that prevent intialization of the fkip-flops(FPIs)are identified, finally propagation path of the FPI is checked. Time complexity of this algorithm is porportional to the product of the number of flip flops with at lest a self loop and the number of gates in the circuit. Experiments were performed on the ISCAS89 benchmark ciruits to show the feadibility of the proposed algorithm.We could identify large amount of undetectable faults(up to 50% of the number of flip-flops)in circuits with uninitializable flip-flops. Consider-ing that most of the time in test generation is cinsumed in identifying undetecatable faults, performance of test generator can be improved by using this algorithm as a pre-processing of test generation.

  • PDF

A Study on the Charging and Diagnosis System of xEV Reusable Waste Battery

  • Park, Sung-Jun;Kim, Chun-Sung;Park, Seong-Mi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_1
    • /
    • pp.669-681
    • /
    • 2021
  • As the supply of xEV in Korea is rapidly increasing, the amount of waste batteries is expected to increase rapidly, but the current recycling system for waste xEV batteries is very insufficient. In order to properly utilize the xEV reusable battery module, it is essential to classify it into a type that has similar discharge characteristics to the current state of health(SOH), which is the discharge capacity of the battery. This paper proposes a system that can minimize the exchange of energy with the KEPCO system by using the charging/discharging method by circulating power between batteries in order to minimize the power consumption when charging and discharging waste batteries. In the proposed system, a function to measure parameters during the charging/discharging test of the waste battery was implemented to build a customized big date for the test waste battery. In addition, the dynamic characteristics of the proposed circuit were analyzed using PSIM, which is useful for power electronics analysis, and the validity of the proposed circuit was verified through experiments.