• Title/Summary/Keyword: in-circuit test

Search Result 1,629, Processing Time 0.034 seconds

MPW Chip Implementation and Verification of High-performance Vector Inner Product Calculation Circuit for SVM-based Object Recognition (SVM 기반 사물 인식을 위한 고성능 벡터 내적 연산 회로의 MPW 칩 구현 및 검증)

  • Shin, Jaeho;Kim, Soojin;Cho, Kyeongsoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.124-129
    • /
    • 2013
  • This paper proposes a high-performance vector inner product calculation circuit for real-time object recognition based on SVM algorithm. SVM algorithm shows a higher detection rate than other object recognition algorithms. However, it requires a huge amount of computational efforts. Since vector inner product calculation is one of the major operations of SVM algorithm, it is important to implement a high-performance vector inner product calculation circuit for real-time object recognition capability. The proposed circuit adopts the pipeline architecture with six stages to increase the operating speed and makes it possible to recognize objects in real time based on SVM. The proposed circuit was described in Verilog HDL at RTL. For silicon verification, an MPW chip was fabricated using TSMC 180nm standard cell library. The operation of the implemented MPW chip was verified on the test board with test application software developed for the chip verification.

Correlation between Cardiopulmonary System Function and Body Fat by Circuit Training and Ephedra Herba in Taeumin Women (Circuit training과 마황(麻黃) 복용이 태음인 여성의 심폐기능향상과 체지방감소에 미치는 상관성 연구)

  • Park, Sung-Ho;Cho, Hyun-Chol;Choi, Seung-Peom;Song, Yun-Kyung;Lim, Hyung-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.15 no.1
    • /
    • pp.39-65
    • /
    • 2005
  • Objectives : This study was aimed to find out correlation of relation between cardiopulmonary function and body fat. Methods : We studied tendency of change of cardiopulmonary function and body fat for medication of Ephedrae Herba capsule by ergogenic aids with circuit training. We got the results for Exercise stress test and Segmental Bioelectrical Impedence Analysis. Results : 1. Sample Group of Ephedrae Herba medication and Circuit training generally showed the insignificant improvement of Body composition, but Control Group of Placebo and Circuit training significantly(p<.05) showed significant improvement of Body composition. 2. Sample Group of Ephedrae Herba medication and Circuit training generally showed the significant improvement of cardio-pulmonary function. Control Group of Placebo and Circuit training showed insignificant elevation of Cardiopulmonary function. 3. In the case of Sample Group, there wasn't closely correlation relationship of improvement of cardiopulmonary function and body composition, but in the case of Control Group, there was closely correlation relationship of improvement of cardiopulmonary function and body composition. Conclusions : It might be recognized that cardiopulmonary function has the correlation of body composition, and Ephedrae Herba might help the reduction of Body Fat by elevation of Cardiopulmonary function for ergogenic aids and it might be needed further study In various viewpoints.

Characteristic Analysis of a Ex Circuit of Ex LED Signal Lamp Operating with AC/DC 12~254 V (AC/DC 12~254 V로 동작하는 방폭 LED Signal Lamp용 방폭 회로의 특성 분석)

  • Jeong, Min-Joo;Her, In-Sung;Kang, In-Cheol;Yu, Young-Moon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.11
    • /
    • pp.690-695
    • /
    • 2014
  • In this paper, we develop a explosion-proof LED lighting (Ex circuit) circuit of Explosion-proof LED Signal Lamp (Ex LSL) to utilize the core module of the explosion-proof Local Control System (Ex LCS) for offshore plant applications. And then analyzed its electrical, optical and thermal characteristics. Ex circuit was applied input voltage from AC/DC(12~254) V. In this experiments, stable light-on characteristics were confirmed by eyes for the every input voltages with min. 78,462 and max. $517,975cd/m^2$ of luminance. also Output current and output luminance was made proportional. Because the measured maximum surface temperature of Ex circuit was $54.23^{\circ}C$ at AC 48 V, Ex circuit was rated with T6 of temperature class. Finally, Ex circuit was shown stable light on characteristics under the $-50^{\circ}C$ and $60^{\circ}C$ during 12 hours of test period.

Design of the RLG Current Stabilizer for Attitude Control in the Satellite (저궤도 위성 자세제어용 RLG 전류 안정화 회로 설계)

  • Kim, Eui-Chan;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.98-101
    • /
    • 2008
  • In this paper, we describe the RLG current stabilizer circuit for attitude control in the satellite. The RLG makes use of the Sagnac effect within a resonant of a HeNe laser. The difference between two discharge currents causes one of the gyro bias errors. The theoretical background and current stabilizer are introduced. It is verified that the circuit designed is applicable to the test of input voltage and temperature.

Analysis IGBT gate Surge voltage characterization by stray inductance (기생 인덕턴스에 의한 게이트 서지 전압 특성분석)

  • Lee, Gun Ho
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.285-286
    • /
    • 2014
  • Recently, the unipolar gate power source is preferred in inverter system because of cost reduction reason. In this case, designer uses 0V source for turning-off the switching devices instead of negative voltage at Vee source. If the gate driver circuit has some stray inductance, the gate voltage would happen a surge voltage. This paper analyzes that of stray inductance effect during the switching behavior in the circuit and the proposed solutions were verified by pulse test.

  • PDF

A Study on the Prediction of the Mechanical Properties of Printed Circuit Boards Using Modal Parameters (모달 파라미터 정보를 활용한 PCB 물성 예측에 관한 연구)

  • Choo, Jeong Hwan;Jung, Hyun Bum;Hong, Sang Ryel;Kim, Yong Kap;Kim, Jae San
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.5
    • /
    • pp.421-426
    • /
    • 2017
  • In this study, we propose a method for predicting the mechanical properties of the printed circuit board (PCB) that has transversely isotropic characteristics. Unlike the isotropic material, there is no specific test standard for acquisition of the transversely isotropic properties. In addition, common material test methods are not readily applicable to that type of laminated thin plate. Utilizing the natural frequency obtained by a modal test and the sizing optimization technique provided in $OptiStruct^{(R)}$, the mechanical properties of a PCB were derived to minimize the difference between test and analysis results. In addition, the validity of the predicted mechanical properties was confirmed by the MAC (Modal Assurance Criteria) value of each of the compared mode shapes. This proposed approach is expected to be extended to the structural analysis for the design verification of the top product that includes a PCB.

Dead Operation Characteristics of Earth Leakage Circuit Breaker for 50[A] Against Surge Voltages (서지전압에 대한 50[A]용 누전차단기의 부동작 특성)

  • 이승칠;장석훈;이복희
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.5
    • /
    • pp.44-52
    • /
    • 1997
  • Electronic circuits with semiconductor and IC are very weak against the surge voltage and currents. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of the earth leakage circuit breaker(ELB) due to the operation of surge protective devices, and the interruption of AC power lines on account of the malfunction of the ELB brings about several disadvantages such as low operation efficiency and reliability of electronic and informational systems, economical loss, and etc. The aim of the present work is to investigate the dead operation characteristics of the ELB against the surge voltages. The impulse generator of 10[kV) in an 1.2/ 50[~) voltage waveform was fabricated. The dead operation characteristics of the ELB applied by surge voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a consequence, the peak value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not bring about dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELB installed at the AC power lines with the surge protective devices bring about the dead operation.

  • PDF

Fault diagnosis of a logical circuit by use of input grouping method

  • Miyata, Chikara;Kashiwagi, Hiroshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.279-282
    • /
    • 1996
  • The authors have already proposed a method for grouping of inputs of a logical circuit under test (LCUT) by use of M-sequence correlation. We call this method as input grouping (IG) method. In this paper, the authors propose a new method to estimate the faulty part in the circuit by use of IG when some information on the candidate of faulty part can be obtained beforehand. The relationship between IG and fault probabilities of a LCUT, and undetected fault ratios are investigated for various cases. Especially the investigation was made in case where the IG was calculated by use of n correlation functions (I $G_{inp}$). From the theoretical study and simulation results it is shown that the estimation error ratio of fault probabilities and undetected fault ratio of LCUT are sufficiently small even when only a part of correlation functions are used. It is shown that the number of correlation functions which are to be memorized to calculate IG can be considerably reducible from 2$^{n}$ - 1 to n by use of I $G_{inp}$. So this method would be very useful for a fault diagnosis of actual logic circuit.uit.

  • PDF

Developments on Low Cost Protection Circuit of Discharge for D-type Non-rechargeable Lithium Batteries(Li/SOCl2) (D형 리튬 1차 단위전지(Li/SOCl2)용 저가형 과방전 차단회로 개발)

  • Ahn, Mahn-Ki;Jung, Yeong-Tak;Lim, Jae-Sung;Roh, Tae-Joo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.665-674
    • /
    • 2018
  • In this paper, we propose a development results of a D-type non-rechargeable lithium battery($Li/SOCl_2$) on improvement in a low cost protection circuit of discharge for domestic military power source. According to this study, we describe a new design and product with 8-bit microcontroller in the protection circuit which can estimate state of health of the battery regardless of occurring an initial voltage delay. Also this paper discuss and facilitate development as solution to a safety about the non-rechargeable lithium batteries. As a result, we verified a quality of the protection circuit by a development test and evaluation(DT&E) process.

DESIGN OF A RISE TIME DISCRIMINATION CIRCUIT FOR X-RAY PROPORTIONAL COUNTER (X-선 비례계수관용 상승시간 선별회로 제작)

  • 남욱원;최철성
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.1
    • /
    • pp.66-77
    • /
    • 1995
  • It is possible to distinguish X-ray events from non X-ray events in proportional conters using the method of rise time discrimination (RTD). In order to subtract non X-ray background, we have developed a simple RTD circuit which will be applied to the proportional counter planned for a sounding rocket experiment. The entire circuit consists of two parts ; the rise time measurement circuit and the time to amplitude conversion circuit which includes the self-calibration mode. From the test with X-ray detecting system, we obtained that the background can be rejected more than 80% in the energy band 2∼12 keV. However we confirmed that the RDT method is not proper to be used for the energy range above 12kV.

  • PDF