• 제목/요약/키워드: in line motor

검색결과 710건 처리시간 0.026초

Analysis of Off-Line and On-Line Partial Discharge in High Voltage Motor Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Lee, Sang-Kil;Kim, Beom-Soo;Kim, Doo-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1086-1092
    • /
    • 2015
  • The off-line and on-line partial discharge (PD) in the stator winding of three high-voltage (HV) motors (1,400 HP, 6.6 kV) is measured and analyzed in this paper. The off-line PD is measured at high values between 24,300 ~ 36,100 pC after 18 years of motor operation. Spare replacement motors were not available for testing the degree of deterioration of the stator windings in standstill status. Therefore, on-line periodic analysis was conducted to monitor the trend of PD after installing a ceramic sensor (110 pF, 6.6 kV) in the terminal box for each phase of each motor. In the stator winding of the No.1 and No.2 HV motors, which showed high magnitudes of off-line PD and low magnitudes of on-line PD, defects are expected to appear in the neutral end of the winding. On the contrary, in the stator windings of the No.3 HV motor, which exhibits high off-line and on-line PD magnitude, defects are expected to appear in the terminal end of the winding where a voltage close to the phase voltage is applied.

단상 유도형 동기 전동기(LSPM)의 특성해석에 관한 연구 (A Study on the Characteristics in Single-Phase Line-Start Permanent Magnet Moter)

  • 정대성;김승주;이진헌;최재학;이주
    • 조명전기설비학회논문지
    • /
    • 제21권3호
    • /
    • pp.125-131
    • /
    • 2007
  • 가전분야에서의 전동기 효율향상을 통한 에너지 소비절감 효과는 상당히 크지만 이를 위한 전동기의 설계/해석 기술 확보가 아직은 미흡한 상태이다. 이에 따라 유도형 동기전동기가 제안되었지만, 유도형 동기 전동기는 유도전동기와 통기전동기의 특성을 동시에 가지고 있어, 해석 및 설계가 쉽지 않다. 따라서 본 논문에서는 기존의 냉장고 압축기용 전동기인 단상유도전동기를 대처할 수 있는 단상 유도형 동기전동기를 이용해 파라미터에 따라 특성이 어떻게 바뀌는가에 대해 서술하였다. 그에 따라 단상유도전동기의 정상상태 특성을 해석하고 제안모델의 성능을 기존모델과 비교하고 실험하여 해석결과의 신뢰성을 검증한다. 또한 본 논문에서는 제안모델의 기존 고정자 형상이나 권선 스팩을 유지하고 회전자의 형상이나 구조만을 변경시켜 성능향상을 도모하였다. 해석방법으로는 전자장 수치 해석적인 방법으로 널리 이용되고 있는 유한요소법(Finite Element Method : FEM)을 이용하였다.

표면 근전도와 전기 탐침기를 이용한 상완이두근의 운동점 표지 비교 연구 (Comparison Study about Surface Mapping of Motor Points in Biceps Brachii Muscle Using Surface EMG and Electric Probe)

  • 박재원;금동호
    • 한방재활의학과학회지
    • /
    • 제28권1호
    • /
    • pp.85-96
    • /
    • 2018
  • Objectives This study was performed to compare the electrical methods of motor points mapping using surface EMG and electric probe (Pointer Excel II). Methods 32 healthy adults (male 16, female 16) were selected. and classified into two groups; surface EMG group, electric probe (Pointer Excel II) group. In surface EMG group, motor points were searched by recoding the compound muscle potentials. In electric probe (Pointer Excel II) group, motor points were searched by scanning the skin with Pointer Excel II at low level stimulation. The locations of the motor points were expressed as X and Y values in relation to the reference line. The horizontal reference line was set as elbow crease and the vertical reference line was set as the line connecting coracoid process to the center of the horizontal reference line. The data was analyzed by 'Independent T-test' and 'equivalence test'. Results 1. The motor points of short head and long head of biceps brachii muscle were located at about 2/3 length of the vertical reference line from coracoid process and about 1/5~1/4 length of the half of the horizontal reference line from the vertical reference line in both group. 2. The motor points of the short head were located more distally and close to the vertical reference line (p<0.001). 3. In surface EMG group, the motor points of the long head were located more laterally in the female than male. And the motor points of the long head were located more distally in the left side than right side (p<0.05). In electric probe (Pointer Excel II) group, similar tendency was observed but there was no statistically significant difference (p>0.05). 4. As a result of the equivalence test between surface EMG group and electric probe (Pointer Excel II) group, the confidence intervals of the difference were within the equivalence limit. Therefore, the locations of the motor points searched by two ways are equa l (p>0.05, equivalence interval=3%). Conclusions The results indicate that electric probe (Pointer Excel II) can be used to search the motor points instead of surface EMG. This might improve the clinical efficiency when using the motor points to treat muscle dysfunction.

단상 영구자석형 유도동기기의 정상상태 특성해석 (Steady-State Characteristic Analysis of Single-Phase Line-Start Permanent Magnet Synchronous Motor)

  • 강규홍;남혁;홍정표
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권2호
    • /
    • pp.53-60
    • /
    • 2003
  • This paper deals with steady-state analysis of a single-phase line-start permanent magnet synchronous motor. In order to analyze the steady-state characteristics, the asymmetric single-phase line-start synchronous motor is converted to the symmetric two-phase synchronous motor, that is, the asymmetric magnetic field is separated from the positive and the negative symmetric components using symmetrical-component theory. The analysis method of the synchronous motor on the d-q axis coordinates is used for the positive component and the equivalent circuit of the induction motor is applied for the negative component analysis. Moreover, d-q axis inductance considering current phase angle is applied to positive component analysis for precise characteristic analysis. In order to validate the proposed analysis method, the analysis results are compared with the experimental results.

단상 유도형 동기전동기의 회전자 설계에 관한 연구 (A study on the Rotor Design in Single-phase Line-start Permanent Magnet Motor)

  • 김원호
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.29-35
    • /
    • 2014
  • The purpose of this paper is the rotor design of a single-phase LSPM(Line-start permanent magnet) motor. A single-phase LSPM motor has a permanent magnet in the rotor that is same as induction motor. For that reason, magnet is operated by breaking torque in starting region and alignment torque in driving region. Therefore, we need the design process considering the trade-off relationship. In this paper, we propose the design process of a single-phase LSPM motor for a high starting torque and efficiency with FEM. And we use Taguchi Method for considering tolerance in manufacture. Finally, we compared the LSPM motor that is designed in this paper and conventional induction motor.

직립 기동 영구자석 동기전동기의 기동토크 최적화 설계 (Optimal Design for Starting -Torque of Line-Start Permanent Magnet Synchronous Motors)

  • 김병국;문지우;김미정;이병준;조윤현
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1390-1396
    • /
    • 2007
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However, it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor. Finally this paper gives the comparison between the simulation results and the experimental results.

단상 직립 기동형 영구자석 동기기의 회로정수에 따른 특성 해석 (Characteristic Analysis of Single Phase Line-start Permanent Magnet Synchronous Motor Considering Circuit Parameters)

  • 강규홍;홍정표
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권6호
    • /
    • pp.262-270
    • /
    • 2003
  • In this paper, the characteristics of single-phase line-start permanent magnet synchronous motor driven by constant voltage are analyzed on d-q axis vector diagram and compared with that of current controlled motor. The coupled method of symmetrical coordinates and d-q axis voltage equation are applied to the analysis method like the analysis of single-phase induction motor. From the result of the analysis, it is seen that motors driven by constant voltage source have effects on not only the amplitude of current and torque but also current and current phase angle, so overall characteristics such as power factor and load angle are affected by circuit parameters. For precise analysis and design of single-phase line-start synchronous motor, its characteristics should be analyzed on d-q axis vector plan in consideration of the variation of circuit parameters.

직립 기동 영구자석 동기전동기의 동특성 해석 (Dynamic Characteristic Analysis of Line-Start Permanent Magnet Synchronous Motor)

  • 김병국;조원영;이인재;문지우;김미정;임성환;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.185-187
    • /
    • 2006
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor.

  • PDF

직립 기동 영구자석 동기전동기의 최적설계 및 동특성 해석 (Optimal Design and Dynamic Characteristic Analysis of Line Start Permanent Magnet Synchronous Motor)

  • 김도선;김병국;이병준;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.92-94
    • /
    • 2008
  • The interest in permanent magnet synchronous motor is present in a wide area of applications, ranging from high-performance servo drive to line-start application[1]. The are mainly two reasons for this trend: first low rotor losses and second the foiling prices of high-energy magnets. In this paper the dynamic characteristic of the line-start permanent magnet synchronous motor are described and compared with those if the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bar in the line-start permanent magnet synchronous motor.

  • PDF

비대칭 불평형 전압 운전시 유도전동기의 동작 특성 해석 (Analysis on the Operation Characteristics of Induction Motor Operated by Asymmetric Unbalanced Voltage)

  • 김종겸;손홍관;정종호;이은웅
    • 전기학회논문지P
    • /
    • 제53권2호
    • /
    • pp.58-64
    • /
    • 2004
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Voltage unbalance is a condition in a polyphase system in which the rms values of the line-to-line voltages or the phase angles between consecutive line-to-line voltages, are not all equal. Slight voltage unbalance generates a disproportionately high current unbalance at the motor stator winding. This paper presents a scheme on operation states of a three-phase induction motor under unbalanced voltages. The three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting the magnitude and phase angle of each phase. The voltage unbalanced factor(VUF) of the three-phase source voltages can then be varied to examine the different values of VUF on machine's operation characteristics.