• Title/Summary/Keyword: impression materials

Search Result 313, Processing Time 0.021 seconds

A Study on the Preference of Design Components of Shop Facade (숍 파사드 디자인 구성요소에 대한 선호도 연구)

  • Yeo, Mi;Oh, Sun Ae
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.2
    • /
    • pp.171-179
    • /
    • 2015
  • The aim of this study is to figure out the preference features on design components of shop facade on the basis of the questionnaire survey on short-term memory and sensory memory of human right after an image experiment. As for a preceding research, this study examined the design features of facade into tangible elements and intangible elements, and also classified them into physical, aesthetical, marketing and symbolic components in detail. And, it extracted 5 representative elements in preceding studies including shape, material, pattern, color and sign, which is the standard of a questionnaire survey and preference analysis. The subjects of the experiment were 30 men and women who were over 20 years old majoring interior design. They were exposed to 20 images with 10 seconds respectively through a video, and were asked to respond the questionnaire promptly. The findings of preference analysis of design components of facade including shape, material, pattern, color and sign are as follows. Firstly, shape was the most interesting and attracting component, and designs applied with shape of objects such as 'web', 'drawer', 'wheel' and 'button' obtained high preference. Secondly, as for material, block, steel, exposed concrete board attracted higher preference as memorable materials than other materials. Material was affected by shape, pattern and color. Thirdly, pattern was the most lasting element. Designed pattern had higher preference than simple pattern. Fourthly, as for color, red and green with strong stimulation and attention attained priority having long lasting memory. Fifthly, when visiting a shop, sign out of 5 elements of shape, material, pattern, color and sign drew attention the most. As for the preference of location of sign, 'center top' was the most noticeable. The findings of this study could be utilized for facade design, and also could be used for commercialization considering highly preferred components, and top preference aspects of such elements. advised that to give an impression to customers is important to make a successful design for sales marketing, which, in turn, would lead customers to revisit the shop.

THE EFFECTS OF POROUS HYDROXYAPATITE AND NATURAL CORAL ON HUMAN PERIODONTAL DEFECTS (인체 치간부위 치조골 결손에 사용된 합성골의 효과에 관한 연구)

  • Shim, Jeong-Min;Choi, Kwang-Choon;Son, Seong-Heul
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.2
    • /
    • pp.345-351
    • /
    • 1993
  • Various alloplastic materials have been used on the periodontally diseased ossous defects. Hydroxyapatite, which is used the most common alloplastic material is a non-resorbable form of calcium phosphate and natural coral which is a biodegradable by carbonic anhydrase in osteoclast was introduced recently. The purpose of the present study was to evaluate the clinical effects of porous hydoxyapatite and natural coral on the human periodontal defects. Four males and three females who had adult periodontitis were selected for this study. The teeth that had similar bone loss radiographically and periodontal pocket deeper than 5mm were selected. Gingival recession, pocket depth, plaque index(Silness & Loe), sulcus bleeding index and tooth mobility (measured by Periotest$^{(r)}$) were examined before graft. Before insertion of alloplastic materials, the depth from CEJ to bone crest and from CEJ to base of the osseous defect was recorded. Porous particulate hydroxyapatite(Interpore 200$^{(r)}$, A group) was place on the defect and natural coral(Biocoral$^{(r)}$, B group) was placed on the defect of the opposing tooth. Six months post-surgically the same parameters were recorded by reentry procedures. A and B group showed 0.6mm of mean recession. Mean reduction of pocket depth were 5mm for A group and 4.9mm of B group. Reduced SBI and tooth mobility were recorded. Osseous defect fills of the original defects were 2.9mm for A and 3mm for B group. Percentage defect fills were 71% for A and 59% for B group. The difference of defect fill between pre- and post-insertion was statstically significant(p<0.05). But the difference between the two groups was not significant statistically(p<0.05). The clinical impression at 6 month re-entry and the numerical date indicate that natural coral as well as porous particulate hydoxyapatite has a definite potential as an alloplastic implant in the treatment of periodontal osseous defects.

  • PDF

A Study on Coloration Trend of Hanbok in 2000's - Focused on Types of Coloration and Hanbok - (2000년대 한복에 나타난 배색 경향에 관한 연구 - 배색의 유형과 한복의 종류를 중심으로 -)

  • Lee, Young-Hae;Kang, Soon-Che
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.4 s.113
    • /
    • pp.45-60
    • /
    • 2007
  • Characteristics of Hanbok's traditional coloration have been carried on, based on social/cultural background of the past. Today, Hanbok is classified as traditional Hanbok, improved Hanbok, living Hanbok. Their designs, materials and colorations show significant differences. In this study, first, we have categorized and arranged the coloration trend of the women's Hanbok according to the types of coloration since 2000s. Secondly, Hanbok is classified as traditional Hanbok, improved Hanbok, and living Hanbok. And then examining their coloration trend and coloration characteristics of different types of Hanbok, so we can find the purpose far increasing understanding of various color beauty and coloration of today's Hanbok. The findings of this research are summarized as follows; 1. Traditional Hanbok coloration is influenced by the modern rotor and tone, and is apt to show the trend of emphasizing individuality. 2. Hanbok coloration of middle period in 2000's has become to use high value and chroma, giving more bright and luxurious impression then the early period. 3. For this study, we have categorized the total of 277 women's Hanboks by their coloration trends, through studying traditional Hanbok catalogues that enclosed vividly colored pure silk samples. As a result, it shows the order of contrary coloration(149), tone on tone coloration(56), similar coloration(23), monochrome coloration(20), tone in tone coloration(17), and 화학섬유chrome coloration(12). 4. Traditional, improved and living Hanbok show differences not only in their designs or materials but also in colorations. Using of traditional coloration is applied to traditional Hanbok and improved Hanbok in that order, and mostly the value and chroma of living Hanbok colorations are low, which emphasizes easiness to move and practicality.

THE EFFECT OF SCREW HOLE SEALING METHOD ON ABUTMENT SCREW LOOSENING IN DENIAL IMPLANT (임플랜트 보철물의 나사구멍 봉쇄방법이 지대나사 풀림에 미치는 영향에 관한 연구)

  • Lim, Jae-Bin;Yim, Soon-Ho;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.767-780
    • /
    • 1997
  • One of the most common problems of implant prosthesis is the screw loosening of abutment screws. This brings on discomfort in mastication, inflammation in the peri-implant tissue due to poor oral hygiene and fracture of prosthesis or loss of osseointegration. To prevent screw loosening, appropriate implantation to direct the occlusal force to the long axis of the implant, accurate design of the superstructure, decrease of the occlusal table, and adequate torque on the abutment screw are necessary. In this study the screw loosening torque was evaluated in implants with dimples or flutes in the internal surface of abutment screw holes. The abutments were fastened with slot type and hexagonal type abutment screws and were sealed with vinyl poly siloxane impression and bite registration material respectively. The screw loosening torque was evaluated after 1,800 and 12,600 times loading under a loading machine. The results were as follows. 1. The flute form group showed significantly higher loosening torque compared to the dimple form group and the group with no inner surface treatment (p<0.05). 2. There was no statistical difference in loosening torque according to the sealing materials. 3. The loosening torque according to the types of abutment screw showed no significant difference. 4. The loosening torque was significantly higher after 1800 times loading compared to 12600 times loading(p<0.05). From the above results. it is thought that formation of a flute in the internal surface of the screw hole decreases the chance of screw loosening, but the sealing materials and types of abutment screw did not show significant difference in prevention of screw loosening.

  • PDF

Different Bone Graft Materials in Intrabony Defects (치조골내낭에 수종의 골이식재 이식후 혈소판 유래 성장인자의 분포에 관한 면역조직화학적 연구)

  • Um, Heung-Sik;Han, Soo-Boo;Lee, Jae-Il;Kim, Hyun-Jong;Chang, Beom-Sek
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.1
    • /
    • pp.45-59
    • /
    • 1997
  • Platelet-derived growth factor(PDGF) has been shown to play an important role in periodontal regeneration. The purpose of the present study was to examine the distribution of PDGF in experimentally created periodontal intrabony defects after flap surgery with various bone graft materials. Six healthy mongrel dogs were used in this study. Three-wall bony defects were created in maxillary and mandibular premolars, inflammation induced by wire ligation and injection of impression material into the defects. Eight weeks later, the experimental lesions thus obtained were treated by plain flap surgery(control group), flap surgery plus autogenous bone graft(autogenous bone group), flap surgery plus Biocoral graft(Biocoral group), or flap surgery plus bioglass graft(bioglass group), which were randomly assigned to the defects. After 4, H, and 12 weeks postoperatively, 2 dogs were sacrificed at each time and 1he specimens were taken for histological examinations and immunohistochemical examinations for PDGF. In the control defects the amount of new bone formation was minimal. In the autogenous bone and Biocoral group new bone was deposited around implanted particles and the amount of new bone was increased with time. A large number of bioglass particles exibited a central excabation and bone formation could be observed in the central excabation as well as around the particles. The expression of PDGF was low in the control group. The expression of PDGF in Biocoral group was increased at 1, H week, but decreased at 12 week. The increased PDGF expression in autogenous bone and bioglass group was maintained to the end of the experiment.

  • PDF

CLINICAL EVALUATION OF CORALLINE BASED POROUS HYDROXYAPATITE AND CORALLINE BASED CALCIUM CARBONATE IN HUMAN INTRABONY PERIODONTAL LESIONS (Coralline Based Porous Hydroxyapatite와 Coralline Based Calcium Carbonate의 이식후 치조골내결손부에 대한 임상적 평가)

  • Shim, Jung-Min;Son, Seong-Heui;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.1
    • /
    • pp.120-130
    • /
    • 1994
  • The purpose of the present investigation was to compare the effectiveness of porous hydroxyapatite (PHA) and coralline based porous calcium carbonate(PCC) as implant materials in human periodontal osseous defects. 10 adult patients having periodontitis and 2 similar angular osseous defects ${\ge}$5mm as verified by radiographic analysis and clinical probing depth ${\ge}$4mm were selected. The measurements were recorded just before surgery and after 6 month. Clinical parameters used in this study included gingival recession, pocket depth, probing attachment level, Sulcus Bleeding Index, Plaque Index, tooth mobility and bone defect depth measurements. After initial therapy, patients were treated with mucoperiosteal flap surgery. The contralateral bony defects in each patient randomly assigned to either bone graft material, one with PHA(Interpore 200) and the other with coralline based calcium carbonate(Biocoral). After 6 month both groups showed statistically significant reduction of pocket depth, Sulcus Bleeding Index, Plaque Index and significant improvement in probing attachment level. No statistically significant differences were found between the groups. There were 3.0mm or 68% of bone repair with PHA and 3.1mm, 61% with PCC. These values were likewise not significantly different. The data and clinical impression strongly suggest that both PHA and PCC are alloplastic implants with clinically apparent acceptance by the soft and hard tissue and that they can be used as bone graft materials successfully.

  • PDF

Changes in pre-osteoblast cells associated with non-precious metal cores with dental implants: Pilot test (치과용 임플란트 적용 비귀금속 코어와 관련된 전조골세포의 변화)

  • Park, Jung-Hyun;Kang, Seen-Young;Kim, Jong-Woo;Kim, Jang-Ju;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.40 no.2
    • /
    • pp.63-69
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the non-precious metal core materials used in the dental laboratory to fabricate the implant superstructure by CAD / CAM method. And to observe and compare the morphology and distribution of the osteoblasts in relation to implant osseointegration. Methods: In this study, the mandibular right first molar tooth model was selected as an international standard to produce a single core. Using this model, the impression was made with the silicone rubber, the tooth model was scanned, and a single core was designed and 5-axis milling was performed. The materials used were Cobalt-Chromium and Nickel-Chromium, and the cores for dental implant top structures were fabricated according to the procedures of the dental labs. After the fabrication, the marginal area of the core was separated and cell culture experiment was performed. The osteoblast cells used MC3T3-E1, which is currently widely used. For morphological analysis of osteoblasts, cells were posttreated and observed using CLSM (Confocal Laser Scanning Microscope) and compared. Results: The cell adhesion behavior of the specimen surface measured by CLSM was uniformly distributed in specimen A (Cobalt-Chromium) than in specimen B (Nickel-Chromium). The distribution and changes of the cells were different in the two specimens. Conclusion : It is possible to confirm that specimen A (Cobalt-Chromium) is suitable for the living body through adhesion and proliferation of osteoblasts related to implant osseointegration in the non-precious metal superstructure used after implantation. It is considered that it is preferable to use Co-Cr when fabricating the superstructure.

A Study of the Ornamental Metal used in the Eaves of Ancient Architecture in Korea (고대 건축의 처마에 사용된 금속장식에 관한 연구)

  • Youn, Lily
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.5
    • /
    • pp.117-124
    • /
    • 2020
  • This study examined ornamental metals used as architectural members among metal artifacts excavated from ancient Buddhist temples and palaces in Korea. Through this, we approached the decorative characteristics of ancient architecture eaves. 1. The decorations used in eaves of Korean ancient architecture include roof-end tiles and ornamental metal. Through excavation examples, the technique of attaching ornamental metal to the rafters and corner rafters of high-ranking architectures in the 7th and 8th centuries (ornamental metal for rafter end, ornamental metal for corner rafter end), and tosu iron in the 10th century It seems to be fashionable. 2. Several buildings were built in ancient Buddhist temples and palaces. At this time, they differentiated ornamental metal according to the hierarchy of the building. The higher the hierarchy, the greater the difference in the number of ornamental metal installations, materials, and decoration techniques. In addition, ornamental metal used in eaves is an important factor in the discrimination of the times as the type, number of members, and patterns change depending on the era. 3. The great feature of the eaves metal decoration excavated in the 7th and 8th centuries is the attachment of ornamental metal to the rafters and horsetails. This seems to create a sense of grandeur by removing the weight of the roof and giving the impression constructed regardless of gravity by supporting it with non-material materials.

3D quantitative analysis and SEM qualitative analysis of natural antagonist enamel opposing CAD-CAM monolithic zirconia or lithium disilicate tooth-supported crowns versus enamel opposing natural enamel

  • Piyarat Woraganjanaboon;Chuchai Anunmana
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the maximum vertical wear, volume wear, and surface characteristic of antagonist enamel, opposing monolithic zirconia or lithium disilicate crowns. MATERIALS AND METHODS. The study comprised 24 participants (n = 12), who were randomly allocated to receive either a 5 mol% Y-TZP or a lithium disilicate crown in positions which would oppose the natural first molar tooth. The contralateral first molar along with its antagonist was considered as the enamel opposing natural enamel control. Data collection was performed using an intraoral scanner and polyvinylsiloxane impression. The means of the maximum vertical loss and the volume loss at the occlusal contact areas of the crowns and the various natural antagonists were measured by 3D comparison software. A scanning electron microscope was subsequently used to assess the wear characteristics. RESULTS. The one-year results from 22 participants (n = 11) indicated no significant differences when comparing the zirconia crown's antagonist enamel (40.28 ± 9.11 ㎛, 0.04 ± 0.02 mm3) and the natural enamel wear (38.91 ± 7.09 ㎛, 0.04 ± 0.02 mm3) (P > .05). Also, there is no significant differences between lithium disilicate crown's antagonist enamel (47.81 ± 9.41 ㎛, 0.04 ± 0.02 mm3) and the natural enamel wear (39.11 ± 7.90 ㎛, 0.04 ± 0.02 mm3) (P > .05). CONCLUSION. While some studies suggested that monolithic zirconia caused less wear on opposing enamel than lithium disilicate, this study found similar wear levels to enamel for both materials compared to natural teeth.

The survey on the infection control of noncritical instruments used in dental treatment (치과 치료에 사용되는 비위험 기구의 감염 관리 실태 조사)

  • Kim, Jae Hyun;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.27-36
    • /
    • 2019
  • Purpose: The aims of this study were to evaluate the dentist's awareness and the actual status of infection control of noncritical dental instruments. Materials and Methods: 40 dental clinics in Daejeon, South Chungcheong, North Chungcheong and North Jeolla provinces were surveyed. The questionnaire was delivered to the dentists belonging to those clinics, and the awareness and the practice of infection control were examined. The microbial contamination on the surface of five noncritical instruments (impression gun, light curing unit, 3-way syringe, shade guide, and dental floss dispenser) used by them was measured with an ATP luminometer. Correlation analysis between the awareness and the actual state of infection control was conducted. Results: Awareness and frequency of infection control was highest in the 3-way syringe. Surface disinfection using disinfectant was most frequent in all instruments. 3-way syringes and shade guides were less contaminated than impression guns, light curing units, and dental floss dispensers. Conclusion: 3-way syringes had a significant correlation between user awareness of infection control and surface contamination, and the higher awareness, the lower the contamination measurement was shown.