The Optical Illusion Effect of Line Applied to Eyebrow Make-up (눈썹 메이크업 표현(表現)에 응용(應用)되는 선(線)의 착시(錯視) 효과(效果))

  • Ha, Sun-Ok;Cho, Koh-Mi;Kim, Chun-Sim
    • Journal of Fashion Business
    • /
    • v.9 no.2
    • /
    • pp.28-39
    • /
    • 2005
  • This chapter presents how 'optical illusion' works in applying makeup and how to differentiate the direction, location and shape at eyebrow lines in the aspect at physiognomy. For this study, employed were five types of face shape produced by Photoshop program - round, square, long, inverted triangle. and diamond. The best-matched facial shape was examined through a questionnaire research after applying the optical illusion of eyebrow lines to the five types of face shape. The results were revealed to be identical to ones presented in make-up teaching materials. In conclusion, it was found that well-matched shape and size of eyebrow could make some changes in the facial impression, changing the face shape into oval shape. The facial line can be modified and supplemented by reshaping such facial parts as the eyebrow, producing well-balanced facial shape. Consequently, make-up was proved to be one of the methods which can be used to create social and psychological effect which can make a favorable facial impression and individuality, natural impression and image making depending on different purposes, taking advantage of optical illusion effect.

The Visual Optical illusion effect study of Lip Make-up (입술 메이크업의 시각적 착시 효과 연구)

  • Ha, Sun-Ok;Cho, Koh-Mi
    • Journal of Fashion Business
    • /
    • v.12 no.1
    • /
    • pp.164-172
    • /
    • 2008
  • A face is the place where individuals can first give their images visually. This chapter presents how 'Visual optical illusion' works in applying makeup and how to differentiate the direction, location and shape of Lip in the aspect of physiognomy. For this study, employed were five types of face shape produced by Photoshop program. The best-matched facial shape was examined through a questionnaire research after applying the optical illusion of Lip to the five types of face shape. The results were revealed to be identical to ones presented in make-up teaching materials. In conclusion, it was found that well-matched shape and size of Lip could make some changes in the facial impression, changing the face shape into oval shape. The facial line can be modified and supplemented by reshaping such facial parts as the Lip, producing well-balanced facial shape. Consequently, make-up was proved to be one of the methods which can be used to create social and psychological effect which can make a favorable facial impression and individuality, natural impression and image making depending on different purposes, taking advantage of optical illusion effect.

A study on the impression and expression tendency of the sankei kanseino poster by Ikko Tanaka (타나카 잇코(Tanaka Ikko) 산케이칸세이노(산경관세능(産經觀世能)) 포스터의 인상과 표현경향에 관한 연구)

  • Cho, Hyung-Soo;Ha, Sang-O;Kawachi, Tomoki
    • Archives of design research
    • /
    • v.20 no.1 s.69
    • /
    • pp.89-100
    • /
    • 2007
  • This research is accompanied with Tanaka's works in order to consider the result from the evaluation of his works through an impression analysis and his expression trendency. The nine posters are chosen for appraisal among a series of Kanseino Poster which Ikko Tanaka drew under the sponsorship of Sankei Newspaper. The reason why those posters are selected is that the structure is strong and simple comparatively. Tanaka Ikko's poster works can be generously explained with three factors through a factor analysis. Considering his works in all cluster analysis, in the first group, he makes a good use of traditional materials and his works have a powerful image. In the second group, a geometric figure is arranged simply and a modern image is strong. In the third group, the traditional materials express a modern image. As mentioned above, the mood of his works can be summarized as follows. $\ulcorner$His works have updated the Japanese image from traditional to modern$\lrcorner$.

  • PDF

DIMENSIONAL CHANGE AND FLEXURAL STRENGTH IN COMPLETE DENTURES FABRICATED BY INJECTION MOLDING AND CONVENTIONAL COMPRESSION PROCESSING (의치상용 레진의 전입 방법에 따른 중합체적변화와 굴곡강도에 관한 연구)

  • Choi Hoon-Dal;Kwon Kung-Rock;Kim Hyeong-Seob;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.478-486
    • /
    • 2005
  • Statement of problem : Fracture and dimensional change of an acrylic resin denture are a rather common occurrence. Purpose : The purpose of this study was to compare differences in dimensional changes and flexural strength of separate maxillary complete dentures after immediate deflasking by injection molding and conventional compression processing. Material and method: To evaluate dimensional stability, the maxillary dentures were fabricated by using different materials and methods. Lucitone 199(Dentsply Trubyte. york, pennsylvania, USA) and Vertex(Dentimex, zeist, Netherlands) were used as materials. Compression and injection packing methods were used as processing methods. The impression surface of the dentures was measured by 3D Scann-ing System(PERCEPTRON USA) and overlapped original impression surface of the master cast. To evaluate flexural strength, resin specimens were made according to the different materials, powder/liquid ratio and processing methods. Flexural strength of the complete resin specimens (64mm$\times$10mm$\times$3.3mm) were measured by INSTRON 4467. (INSTRON, England) The data was analyzed by ANOVA, t-test and Tukey test. (p<.05 level of significance) Result: The results were as follows 1. There was no significant differences between master model and denture base for each group in overall dimensional changes. 2. Palatal area was more stable than flange or alveolar area in dimensional stability. but. there was no significant differences among each area. 3. Materials and power/liquid ratio had an effect on flexural strength. (P<.05) Especially materials was most effective. (P<.05) 4. Lucitone 199(powder/liquid ratio followed by manufacturer's direction) showed higher flexural strength than Vertex. Conclusion : Dimensional stability or flexural strength are affected by materials rather than packing techniques.

Accuracy of the healing abutment and impression coping combined system on implant impression (인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성)

  • Jeon, Kyoung-Bae;Lee, Du-Hyeong;Kim, Jung-Han;Hwang, Jun-Ho;Park, Hyun-We;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.

The Impression Evaluation for Tone Combination of Identical Hue of Shirt and Necktie (셔츠와 넥타이의 동일색상 톤 조합에 따른 인상평가)

  • Lim, Ji-Young;Kang, Kyung-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.8 no.2
    • /
    • pp.1-16
    • /
    • 2006
  • The purpose of this study was to find out the various impressions that tone-on-tone coloration of shirts and ties gives. This experiment was based on the $2{\times}4{\times}4{\times}2$ factorial design: colors(red and blue), shirt tones(vivid, light, dull, and dark); tie tones(vivid, light, dull, and dark) and perceivers' gender(male and female). The materials in the experiment developed for this study were composed of 32 upper body photographs which were color printed and 27 bi-polar adjectives, each of which was graded into seven in its degree, were used to evaluate the impression. We unified those colors of shirts and neckties, and then made shirt and necktie tone different. The subjects of this research were 192 male and 192 female college students in Gyeongnam province including Jinju City The data was analyzed by using SPSS program. Analyzing methods were one-way ANOVA and LSD test. The items of the adjectives were classified into 5 impression dimensions - potency, activity, attractiveness, visibility and tenderness. All the image by the match of shirt and tie could be possible to make various images by the color, the shirt tone and the tie tone. Blue was given more effective potent image, vivid or light tone shirt in blue was the active image. As shirt and tie had different tone, regarded as the attractive image. Vivid tone tie was evaluated the visible image, light tone shirt is the tend image.

  • PDF

Evaluation of different approaches for using a laser scanner in digitization of dental impressions

  • Lee, Wan-Sun;Kim, Woong-Chul;Kim, Hae-Young;Kim, Wook-Tae;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2014
  • PURPOSE. This study aimed to investigate the potential clinical application of digitized silicone rubber impressions by comparing the accuracy of zirconia 3-unit fixed partial dentures (FPDs) fabricated from 2 types of data (working model and impression) obtained from a laser scanner. MATERIALS AND METHODS. Ten working models and impressions were prepared with epoxy resin and vinyl polysiloxane, respectively. Based on the data obtained from the laser scanner (D-700; 3Shape A/S, Copenhagen, Denmark), a total of 20 zirconia frameworks were prepared using a dental CAD/CAM system (DentalDesigner; 3shape A/S, Copenhagen, Denmark / Ener-mill, Dentaim, Seoul, Korea). The silicone replicas were sectioned into four pieces to evaluate the framework fit. The replicas were imaged using a digital microscope, and the fit of the reference points (P1, P2, P3, P4, P5, P6, and P7) were measured using the program in the device. Measured discrepancies were divided into 5 categories of gaps (MG, CG, AWG, AOTG, OG). Data were analyzed with Student's t-test ($\alpha$=0.05), repeated measures ANOVA and two-way ANOVA (${\alpha}=0.05$). RESULTS. The mean gap of the zirconia framework prepared from the working models presented a narrower discrepancy than the frameworks fabricated from the impression bodies. The mean of the total gap in premolars (P=.003) and molars (P=.002) exhibited a statistical difference between two groups. CONCLUSION. The mean gap dimensions of each category showed statistically significant difference. Nonetheless, the digitized impression bodies obtained with a laser scanner were applicable to clinical settings, considering the clinically acceptable marginal fit ($120{\mu}m$).

Cytotoxicity(MTT) evaluation of dental instruments made of polymers (치과용 폴리머 기구의 세포독성(MTT) 평가)

  • Choi, Eun-Mi
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.187-195
    • /
    • 2021
  • In order to assess the cell toxicity of 10 instruments made of polymers, the MTT assay which utilizes the L-929 cell was selected. Specimens were eluted at a temperature of 37℃ for 24 hours at a rate of 4g per 20mL, RPMI 1640, and then was positively and negatively contrasted with a control test solution, in accordance with the Notification No. 2020-12 Protocols of Medical Apparatus Biological Safety from the Ministry of Drug and Food Safety. As a result of 24 hours of incubation in 37℃, 5% CO2 Incubator and assessment using an ELISA reader, the results of Intraoral camera indiciated a cellular viability of more than 70% at a 50% eluate. But, the Plastic impression tray, 3D printing tweezer, Impression disposable syringe, Dental floss holder, Hand implant scaler, Surgical retractor, Oral scanner tip, Dental mirror, and the Water pick tip all reported a cellular viability of more than 70% at a 100% eluate, which indicates that do not exhibit cytotoxicity, thus allowing it to be used in contact with the mucous membrane of the oral cavity.

Correct methods for using alginate Impression materials (알지네이트 인상재의 정확한 사용법)

  • Kim, U-Hyeon;Kim, Gyeong-Nam
    • The Journal of the Korean dental association
    • /
    • v.43 no.9 s.436
    • /
    • pp.576-581
    • /
    • 2005
  • 오늘날 알지네이트 인상재는 다른 어떠한 인상재보다 널리 사용되고 있다. 이는 알지네이트 인상재가 ①사용하기 쉽고, ②환자에게 거부감이 적고, ③특수한 장비의 사용이 필요하지 않으며, ④정확히 사용하면 상당히 정밀한 인상이 가능하기 때문이다. 알지네이트 인상재의 정확한 사용법을 정리한다.