• Title/Summary/Keyword: implant surgery

Search Result 1,655, Processing Time 0.026 seconds

Clinical Durability and Deflation of Saline-Filled Breast Implant in Breast Reconstruction (유방재건술에 사용된 식염수 보형물의 임상적 내구성과 누출)

  • Kim, Il-Kug;Lee, Jun-Ho;Kim, Yong-Ha;Kim, Tae-Gon;Lee, Soo-Jung;Kang, Soo-Hwan
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.808-814
    • /
    • 2011
  • Purpose: Despite wide clinical use of breast implants, there is continued concern about the lifespan of these devices. The causes of explantation were infection, deflation of implant and patient's want. The deflation of saline-filled breast implant was related to strength and durability of implant shell. The purpose of this study is to evaluate the clinical durability of saline-filled breast implant through the analysis of duration until deflation occurred, causes, incidence and influencing factors. Methods: Retrospective analyses were conducted on clinical records for 19 cases of deflation of saline-filled breast implant from 201 cases of breast reconstruction with saline-filled implant between May 1995 and June 2011. The authors had been analyzed the causes of deflation, survival duration, symptom, sign, nipple excision, volume of implant, saline filling, method of reoperation, breast cancer stage and combined capsular contracture. Results: The causes of deflation were attributed to the cases that cannot be evaluated the causes in 15 cases, fall down in 1 case, mammography in 2 cases, accidental needle injury in 1 case. Mean survival duration was 4 years and 5 months. The duration of survival was less than 1 year for 5 cases, 1 year to 10 years for 10 cases, more than 10 years for 4 cases. The volume between 201 and 250 cc of deflated breast implant was rated as high by 14.0 percent. The deflation rate of underfilled implants was 11.4 percent, adequate filled implants was 9.3 percent. None of overfilled implant was deflated. The deflation of smooth surface implant was 5 of 152 cases. Textured implant was 14 of 49 cases. The capsular contracture of non-deflated breast implant was 28 of 182 cases and that of deflated breast implant was 6 of 19 cases. Conclusion: The patients who underwent saline-filled breast implant implantation should be informed that their implant could deflate. The analysis of clinical durability and causes of deflation in breast implant was important for the prediction and prevention of reopeation. The authors could suppose the causes of deflation of saline-filled breast implant through history, duration of survival, inspection of the shell of implant.

Otoplasty with High Density Polyethylene Implant(MEDPOR®) (잠복이에서 고밀도 폴리에틸렌 삽입물(MEDPOR®)을 이용한 귀성형술)

  • Lee, Keun-Cheol;Kwon, Yong-Seok;Heo, Jung;Moon, Ju-Bong;Kim, Seok-Kwun
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.167-173
    • /
    • 2009
  • Purpose: The key points of treatment of cryptotia are the elevation of invaginated ear helix and the correction of deformed cartilage. Prevention of stabilized cartilage contouring from returning to the previous state is also important. The authors carried otoplasty by modified Onizuka's method or Ohmori's method that conchal cartilage graft or high density polyethylene implant(MEDPOR$^{(R)}$) graft served as fixation after spreading posterior aspect of adhered antihelix and a splint for prevention of recurrence of cartilage deformities. The aim of this study is to reveal the availability of the high density polyethylene implant(MEDPOR$^{(R)}$) graft for the correction of cryptotia. Methods: We have repaired 17 cryptotic deformities using cartilage graft from cavum of concha(12 cases) or high density polyethylene implant(5 cases) for correction of deformed cartilage. We investigate the operative time, complications, and satisfaction of postoperative ear shape on both autogenous cartilage graft group and high density polyethylene implant graft group. Results: There was 1 case of reinvagination on autogenous cartilage graft group. Implant exposure was occurred on high density polyethylene implant graft group, as 1 case. These were statistically no differences between autogenous cartilage graft group and high density polyethylene implant graft group to the satisfaction of ear shape. Conclusion: High density polyethylene implant(MEDPOR$^{(R)}$) present an alternative to autogenous material as they allow of fibrovascular ingrowth, leading to stability of the implant and decreased infection rates. The correction of deformed cartilage by using the high density polyethylene implant(MEDPOR$^{(R)}$) is a good option for the treatment of cryptotia.

Evaluation of Breast Animation Deformity following Pre- and Subpectoral Direct-to-Implant Breast Reconstruction: A Randomized Controlled Trial

  • Dyrberg, Diana L.;Bille, Camilla;Koudahl, Vibeke;Gerke, Oke;Sorensen, Jens A.;Thomsen, Jorn B.
    • Archives of Plastic Surgery
    • /
    • v.49 no.5
    • /
    • pp.587-595
    • /
    • 2022
  • Background The incidence of breast animation deformity (BAD) is reported to be substantial after direct-to-implant breast reconstruction with subpectoral implant placement. It has, however, never been examined if BAD can occur following prepectoral implant placement. Our primary aim was to compare the incidence and degree of BAD after direct-to-implant breast reconstruction using either subpectoral or prepectoral implant placement. Secondary aim of this study was to assess and compare the level of pain between sub- and prepectoral reconstructed women. Methods In this randomized controlled trial, patients were allocated to reconstruction by either subpectoral or prepectoral implant placement in accordance with the CONSORT guidelines. The degree of BAD was assessed by the "Nipple, Surrounding skin, Entire breast (NSE)" grading scale 12 months after surgery. The level of postoperative pain was assessed on a numerical pain rating scale. Results We found a significant difference in the degree of BAD favoring patients in the prepectoral group (23.8 vs. 100%, p < 0.0001; mean NSE grading scale score: 0.4 vs. 3.6, p < 0.0001). The subpectoral reconstructed group reported higher levels of pain on the three subsequent days after surgery. No significant difference in pain levels could be found at 3 months postoperatively. Conclusion The incidence and degree of BAD was significantly lower in women reconstructed by prepectoral direct-to-implant breast reconstruction. Unexpectedly, we found mild degrees of BAD in the prepectoral group. When assessing BAD, distortion can be challenging to discern from rippling.

HISTOMORPHOMETRIC EVALUATION OF OSTEOGENESIS WITH BRUSHITE IMPLANT SURFACES IN DOGS (성견에서 거친 표면을 가지는 임플란트에서 골형성에 관한 조직형태계측학적인 평가)

  • Moon, Chul-Woong;Kim, Su-Gwan;Kim, Hak-Kyun;Moon, Seong-Yong;Lim, Sung-Chul;Oh, Ji-Su;Baik, Sung-Mun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.2
    • /
    • pp.150-157
    • /
    • 2008
  • This study evaluated the influence of smooth and brushite-coated implant surfaces in dogs. The first through fourth mandibular premolars were extracted from eight young adult dogs. Twelve weeks after extraction. implantation was performed at the extraction sites. In total, 40 implant fixtures were implanted in the dog mandibles. Twenty machined implants served as controls and twenty brushite-coated surfaces served as tests. Dogs were sacrificed 2 and 4 weeks after implantation. The hemi-mandibles were obtained and processed histologically to obtain non-decalcified sections. Longitudinal sections of each implant were made and analyzed using light microscopy. The overall implant success rate was 83.3%. Histomorphometrically. the experimental group had a better percentage of bone-implant contact than the control group (p<0.05) and there was a significant difference between the 2- and 4-week groups after implantation (p<0.05) Our results suggest that the implant surface morphology influences the increase in peri-implant osteogenesis in the early period of peri-implant healing.

Breast Reconstruction by Pectoralis Major Muscle Transfer with Implants after Skin Sparing Partial Mastectomy (피부보존 유방절제술 후 대흉근전위술과 유방삽입물을 이용한 유방재건술)

  • Park, Jung Min;Kwon, Yong Seok;Lee, Keun Cheol;Kim, Seok Kwun;Lee, Jin Hwa;Jho, Sae Heon
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.573-581
    • /
    • 2005
  • Breast cancer is the second leading cause of death in woman. Unfortunately, the frequency of breast cancer and mastectomy are increasing in Korea. This paper introduces the breast reconstruction by use of pectoralis major muscle transfer with breast implant for small size defect after skin sparing mastectomy for more satisfaction. We reviewed 24 consecutive patients who underwent breast reconstruction by pectoralis major muscle transfer with implant and only breast implant in Dong-A University from April 2002 to March 2004. The patient's age ranged between 29 and 54 years with mean of 42.3 years. We used pectorals major muscle transfer with breast implant in 12 patients and breast implant alone in 12 patients as control. The follow-up period of patients ranged from 10 months to 3 years with mean of 18.5 months. The points of comparison with control group reconstructed by breast implant alone were doctor and patient satisfaction score, operation time, duration of admission, amount of drainage, complication and satisfaction according to mass location. In conclusion, there is no difference with control group in the point of operation time, mount of drainage, duration of admission. And there is higher level of doctor's and patient's satisfaction in group reconstructed by pectoralis major muscle transfer with breast implant than implant only group. Especially, pectoralis major muscle transfer with breast implant was especially necessary for the defect in upper lateral quadrant of the breast to get more satisfaction. The advantage of pectoralis major muscle transfer with breast implant is prevention of the protruding and palpability of implant and aesthetically satisfactory result by intraoperative modification of breast shape.

An assessment of accuracy of half-guided implant surgery using implant surgical guide: A case report (임플란트 수술용 가이드를 사용한 부분 유도 임플란트 수술의 정확도 평가: 증례보고)

  • Kim, Choongkil;Lee, Wonsup;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.150-159
    • /
    • 2019
  • Nowadays, dental implant is one of the widely used treatment options for edentulous patients. Recently, a method of improving the accuracy of implant surgery using an implant surgical guide has been introduced and widely used in order to accurately place the implant in a proper position. Full-guided and half-guided implant surgery can be distinguished according to the level of surgical guide application during the implant surgery. It is true that full-guided implant surgery exhibits higher accuracy, but half- guided implant surgery is often performed in a clinical situation due to the factors such as the circumstances of the operation. A partially edentulous patient who lost teeth due to tooth fracture and periodontal disease was treated using implant and fixed prosthesis. Half-guided implant surgery was performed using an implant surgical guide during implant surgery, the accuracy of implant placement was analyzed.

CLINICAL STUDY ON SUCCESS RATE OF TG OSSEOTITE IMPLANT (TG Osseotite 임플란트의 성공률에 대한 임상적 연구)

  • Oh, Sung-Hwan;Min, Seung-Ki;Chae, Young-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.1
    • /
    • pp.39-47
    • /
    • 2005
  • The purpose of this study is to review the prognosis of the TG Osseotite implant(3i Co, USA) placed in partial edentulous area of oral cavity and to suspect the possible causes leading to failure. 124 TG Osseotite implants that had been inserted between 2000 - 2002 were followed up for 2 years(avg : 9.5 months) in function. Medical records, and radiographs were evaluated and analyzed by the over all success rate, gender and age factor, general disease, implant fixture length and diameter, implant site, bone density, and various surgical methods. Chi square test was used statistically. Of the 124 TG Osseotite implants, 9 implants(7.3%) were removed in early phase and 3 implants(2.4%) were in late phase. The cumulative survival rate was 90.2%. The failure of the TG Osseotite implant was closely related with the use of bone graft techniques such as sinus elevation or immediate implantation and not with the age, sex, general disease, implant site, bone density of implanted site. The failure of the TG Osseotite implant was well developed when it was the wide type of implant and it was inserted for single tooth replacement. The developement of peri-implantitis was the most important factor in the failure of the TG Osseotite implant.

Late Complication of a Silicone Implant Thirty Years after Orbital Fracture Reconstruction

  • Lee, Chi An;Kang, Seok Joo;Yun, Ji Young;Sun, Hook
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.2
    • /
    • pp.137-140
    • /
    • 2017
  • Alloplastic materials used for orbital fracture reconstruction can induce complications, such as infection, migration, extrusion, intraorbital hemorrhage, and residual diplopia. Silicone is one of the alloplastic materials that has been widely used for decades. The author reports a rare case of spontaneous extrusion of a silicone implant that was used for orbital fracture reconstruction 30 years earlier. A 50-year-old man was admitted to the emergency room for an exposed substance in the lower eyelid area of the left eye, which began as a palpable hard nodule a week earlier. The exposed material was considered to be implant used for previous surgery. Under general anesthesia, the implant and parts of the fibrous capsule tissue were removed. Several factors hinder the diagnosis of implant extrusions that occur a long period after the surgery. So, surgeons must be aware that complications with implants can still arise several decades following orbital fracture reconstruction, even without specific causes.

Sensory change after implant surgery: related factors for recovery

  • Jung, Joon-Ho;Ko, Ji-Hoon;Ku, Jeong-Kui;Kim, Jae-Young;Huh, Jong-Ki
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.5
    • /
    • pp.297-302
    • /
    • 2022
  • Objectives: This retrospective study aimed to analyze data on nerve damage in patients who complained of sensory changes after dental implant surgery, the clinical results according to proximity of the implant fixture to the inferior alveolar nerve (IAN) canal, and the factors affecting recovery of sensation. Materials and Methods: The electronic medical records of 64 patients who had experienced sensory change after implant surgery were reviewed. Patients were classified by sex, age, implant installation sites, recovery rate and the distance between the implant fixture and IAN canal on computed tomography (CT). The distance was classified into Group I (D>2 mm), Group II (2 mm≥D>0 mm), and Group III (D≤0 mm). Results: The 64 patients were included and the mean age was 57.3±7.3 years. Among the 36 patients who visited our clinic more than two times, 21 patients (58.3%) reported improvement in sensation, 13 patients (36.1%) had no change in sensation, and 2 patients (5.6%) reported worsening sensation. In Group II, symptom improvement was achieved in all patients regardless of the removal of the implant fixture. In Group III, 8 patients (40.0%) had reported symptom improvement with removal of the implant fixture, and 2 patients (33.3%) of recovered patients showed improvement without removal. Removal of the implant fixture in Group III did not result in any significant difference in recovery (P=0.337), although there was a higher possibility of improvement in sensation in removal cases. Conclusion: Clinicians first should consider removing the fixture when it directly invades the IAN canal. However, in cases of sensory change after dental implant surgery where the drill or implant fixture did not invade the IAN canal, other indirect factors such as flap elevation and damage due to anesthesia should be considered as causes of sensory change. Removal of the implant should be considered with caution in these situations.

Retrospective Study of Sandblasted, Large-grit and Acid-etched Implant (Sandblasted, Large-grit and Acid-etched Implant에 대한 후향적 임상 연구)

  • Jo, Ji-Ho;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su;Park, Jin-Ju;Jung, Jong-Won;Yoon, Dae-Woong;Yang, Seong-Su;Jeong, Mi-Ae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.4
    • /
    • pp.352-358
    • /
    • 2011
  • Purpose: This study evaluated the prognosis and survival rate of SLA (Sandblasted, Large-grit and Acid-etched) implants and it also evaluated the prosthodontic complications and the associated factors. Methods: Twenty seven patients (14 men and 13 women, mean age: 54.9) who visited Chosun University Hospital Implant Center with the chief desire for placement of an implant in an edentulous area from March, 2008 to December 2008 and who received placement of a SLA implant ($Implantium^{(R)}$, Dentium Co., Korea) were selected for this study. Results: The average follow-up period was 15 months and the study was based on the treatment records, radiographs and clinical examinations. A total of 69 implant cases were retrospectively assessed for the width and length of the implant, the primary and secondary stability, the combined surgery, the employed bone graft material and barrier membrane, the status of the opposing tooth, implant failure and the prosthetic complications. During the follow-up period (average: 15 months), the accumulative survival rate of the 69 implants in 27 patients was 100%. Complications such as infection, sinusitis and fixture exposure after surgery were seen for 5 implants in 4 patients. Complications such as screw loosening, contact loosening and peri-implant gingivitis after prosthodontic treatment occurred in 7 cases (10.14%). Conclusion: This study reports placement of SLA implants may cause various complications, yet the final accumulative survival rate was 100%. The SLA implant ($Implantium^{(R)}$) has an excellent clinical survival rate and outcome.