• Title/Summary/Keyword: implant surface

Search Result 969, Processing Time 0.03 seconds

Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant (생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성)

  • Chang, Kap-Sung;Kim, Heung-Joong;Park, Joo-Cheol;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF

Comparion of stability in titanium implants with different surface topographies in dogs

  • Kim, Nam-Sook;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.47-55
    • /
    • 2009
  • STATEMENT OF PROBLEM. A few of studies which compared and continuously measured the stability of various surface treated implants in the same individual had been performed. PURPOSE. We aim to find the clinical significance of surface treatments by observing the differences in the stabilization stages of implant stability. MATERIAL AND METHODS. Eight different surface topographies of dental implants were especially designed for the present study. Machined surface implants were used as a control group. 4 nano-treated surface implants(20 nm $TiO_2$ coating surface, heat-treated 80 nm $TiO_2$ coating surface, CaP coating surface, heat treated CaP coating surface) and 3 micro-treated surface implants [resorbable blast media(RBM) surface, sandblast and acid-etched(SAE) surface, anodized RBM surface] were used as experiment groups. All 24 implants were placed in 3 adult dogs. $Periotest^{(R)}$ & ISQ values measured for 8 weeks and all animals were sacrificed at 8 weeks after surgery. Then the histological analyses were done. RESULTS. In PTV, all implants were stabilized except 1 failed implants. In ISQ values, The lowest stability was observed at different times for each individual. The ISQ values were showed increased tendency after 5 weeks in every groups. After 4 to 5 weeks, the values were stabilized. There was no statistical correlation between the ISQ values and PTV. In the histological findings, the bone formation was observed to be adequate in general and no differences among the 8 surface treated implants. CONCLUSIONS. In this study, the difference in the stability of the implants was determined not by the differences in the surface treatment but by the individual specificity.

Comparison of removal torque of saline-soaking RBM implants and RBM implants in rabbit tibias (토끼의 경골에서 RBM 표면처리 임플란트와 RBM 표면처리 후 Saline에 적신 임플란트의 제거회전력 및 표면분석 비교)

  • Kwon, Jae-Uk;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the effect of the titanium implant soaked in saline after RBM surface treatment on the initial osseointegration by comparing the removal torque and the surface analysis compared to the titanium implant with only RBM surface treatment. Materials and methods: The control group was RBM surface treated implants (RBM), and the test group was implants soaked in saline for 2 weeks after RBM surface treatment (RBM+Sal). The control and test group implants were placed in the left and right tibiae of 10 rabbits, respectively, and at the same time, the insertion torque (ITQ) was measured. After 10 days, the removal torque (RTQ) was measured by exposing the implant site. FE-SEM, EDS, Surface roughness and Raman spectroscopy were performed for the surface analysis of the new implant specimens used in the experiments. Results: There was no significant difference in insertion torque and removal torque between RBM surface treated titanium implants and saline-soaked titanium implants after RBM surface treatment. Conclusion: Saline soaking after RBM surface treatment of titanium implants did not positively affect the initial osseointegration as compared to titanium implants with only RBM surface treatment.

Scanning Electron Microscopic Study of the Effect of Tetracycline-HCl on the Change of Implant Surface Microstructure according to Application Time (염산테트라싸이클린의 적용시간에 따른 임플란트 표면변화에 관한 주사전자현미경적 연구)

  • Kim, Woo-Young;Lee, Man-Sup;Park, Joon-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.523-537
    • /
    • 2002
  • The present study was performed to evaluate the effect of tetracycline - HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used. Implant surface was rubbed with 5Omg/ml tetracycline - HCl solution for ${\frac}{1}{2}$ min., 1 min., $1{\frac}{1}{2}$ min., 2 min., and 3min. respectively in the test group and with no conditioning in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. subsequently, the acid-etching process crated the micro roughness, which thus was superimposed on the macro roughness. 3. In the SLA surfaces, irrespective of the application time of 50mg/ml tetracycline-HCl solution, in general, test specimens were similar to control. 4. In the $TiO_2blasted$ surfaces the control specimen showed the rough surface with small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline-HCl solution was lessened and the flattened areas were wider relative to the application time of tetracycline - HCl solution. In conclusion, pure titanium machined surfaces and SLA surfaces weren't changed irrespective of the application time of tetracycline-HCl solution. And the $TiO_2blasted$ surfaces conditioned with tetracycline - HCl solution began to be changed from $1{\frac}{1}{2}$ min. This results are expected to be applied to the regenerative procedures for peri-implantitis treatment.

A retrospective study of the long-term survival of RESTORE® dental implants with resorbable blast media surface

  • Keun-Soo Ryoo;Pil-Jong Kim;Sungtae Kim;Young-Dan Cho;Young Ku
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.6
    • /
    • pp.444-452
    • /
    • 2023
  • Purpose: The aim of this study was to retrospectively evaluate the survival and failure rates of RESTORE® implants over a follow-up period of 10-15 years at a university dental hospital and to investigate the factors affecting the survival rate of these dental implants. Methods: A total of 247 RESTORE® dental implants with a resorbable blast media (RBM) surface inserted in 86 patients between March 2006 and April 2011 at the Department of Periodontology of Seoul National University Dental Hospital were included. Patients with follow-up periods of less than 10 years were excluded, and data analysis was conducted based on dental records and radiographs. Results: Over a 10- to 15-year period, the cumulative survival rate of the implants was 92.5%. Seventeen implants (6.88%) were explanted due to implant fracture (n=10, 4.05%), peri-implantitis (n=6, 2.43%), and screw fracture (n=1, 0.4%). The results of univariate regression analysis using a Cox proportional hazards model demonstrated that implants placed in male patients (hazard ratio [HR], 4.542; 95% confidence interval [CI], 1.305-15.807; P=0.017) and implants that supported removable prostheses (HR, 15.498; 95% CI, 3.105-77.357; P=0.001) showed statistically significant associations with implant failure. Conclusions: Within the limitations of this retrospective study, the RESTORE® dental implant with an RBM surface has a favorable survival rate with stable clinical outcomes.

CLINICAL STUDY OF ENDOSSEOUS HYDROXYAPATITE COATED IMPLANTS (수종의 Hydroxyapatite coated 골유착성 임프란트의 임상적 연구)

  • Han, Chong-Hyun;Kim, Sung-Hyun;Chul, Jong-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.631-639
    • /
    • 2000
  • Root-form endosseous implants which are in use today have a variety of materials, designs and surface characteristics. Among them, pure titanium surface implants and titanium matrix coated with HA are popular as well as are available in many studies. Rate of clinical success is obviously lower in jaw with cancellous bone than dense bone. In order to increase the rate of success in poor bone quality. More advanced techniques of implant surgery and surface treatment of implant fixture body have been developed. As a successful result, the installation of HA coated implant in bone quality type III or IV became highly successful. Since most clinical studies were performed without knowing the characteristics of HA coated implants, it has been impossible to come up with proper clinical data. Therefore the characterization of HA coated implants is essential to understand long term clinical performance and the predictability of HA coated implant system Our results showed that HA coated implants had the success rate at 93.7% in bone quality type III, IV for 3.8 years, and the fixture of Steri-Oss showed more stability with time.

  • PDF

Effects of various prophylactic procedures on titanium surfaces and biofilm formation

  • Di Salle, Anna;Spagnuolo, Gianrico;Conte, Raffaele;Procino, Alfredo;Peluso, Gianfranco;Rengo, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.6
    • /
    • pp.373-382
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the effects of various prophylactic treatments of titanium implants on bacterial biofilm formation, correlating surface modifications with the biofilms produced by Pseudomonas aeruginosa PAO1, Staphylococcus aureus, and bacteria isolated from saliva. Methods: Pure titanium disks were treated with various prophylactic procedures, and atomic force microscopy (AFM) was used to determine the degree to which surface roughness was modified. To evaluate antibiofilm activity, we used P. aeruginosa PAO1, S. aureus, and saliva-isolated Streptococcus spp., Bacteroides fragilis, and Staphylococcus epidermidis. Results: AFM showed that the surface roughness increased after using the air-polishing device and ultrasonic scaler, while a significant reduction was observed after using a curette or polishing with Detartrine ZTM (DZ) abrasive paste. In addition, we only observed a significant (P<0.01) reduction in biofilm formation on the DZ-treated implant surfaces. Conclusion: In this study, both AFM and antibiofilm analyses indicated that using DZ abrasive paste could be considered as the prophylactic procedure of choice for managing peri-implant lesions and for therapy-resistant cases of periodontitis.

Mechanical Analysis of Macro-Hexagon Porous Dental Implant Using Selective Laser Melting Technique (SLM법으로 매크로 육각다공질 구조를 부여한 치과 임플란트의 역학 분석)

  • Kim, Bu-Sob;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.55-61
    • /
    • 2011
  • Purpose: In this study, FEM(Finite Element Method) and bending strength test was conducted using normal implant and porous implant for the mechanical estimation of porous dental implant made by SLM method. Methods: Mechanical characteristics of PI(porous implant) and NI(normal implant) applied distributed loads(200N, 500N) were observed through FEM analysis. And each bending strength was gotten through bending test using MTS(Mechanical Test System, Instron 8871). Results: The result of FEM analysis was observed that stress difference between upper and surface of PI was 12 times, while NI was 2 times. The result of bending test was observed that bending strength of PI was lower than NI. we made a decision about this result that cross-sectional area of NI was larger than the PI. Conclusion: The stress shielding ability of porous implant was better than normal implant through result of FEM analysis. And bending strength of porous implant was lower than NI. We think that cause of this result was difference of cross-sectional area.

A literature review on the survival rate of single implant-supported restorations (단일 임플란트 지지에 의한 보철물의 생존율에 관한 문헌 연구)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.69-87
    • /
    • 2002
  • Implant material, implant design, surface quality, status of the bone, surgical technique, and implant loading conditions were regarded as prerequisites for osseointegration which is a prime condition for implant success. The aim of this review paper was to investigate the survival rate of single implants in relation to the prerequisites for osseointegration. Fifty-eight papers reporting survival rates of single implants were selected by use of the 'PubMed' and hand searching. The survival rate of single implants were assessed with reference to factors influencing osseointegration. The results showed that single implants in general showed a high survival rate except a few failures in certain extreme conditions and early stages. Those failures and complications such as screw loosening and esthetic problem were almost solved with the development of implant components and surgical techniques and a better understanding of biology around a single implant. Single-tooth implant-replacement is now considered as a reliable and predictable treatment option for a single missing tooth and its application seems to expand to compromised situations which were previously thought to be impossible for single implant therapy.