Nanotube shape on the Ti-29Nb-xHf alloys with applied potentials

  • Park, Seon-Yeong;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.119-119
    • /
    • 2016
  • Over the last years the anodic formation of ordered $TiO_2$ nanotube layers has created significant scientific interest. Titanium oxide nanotube formation on the titanium or titanium alloy surface is expected to be important to improve cell adhesion and proliferation under clinical conditions. It should be possible to control the nanotube size and morphology for biomedical implant use by controlling the applied voltage, alloying element, current density, anodization time, and electrolyte. $TiO_2$ nanotubes show excellent biocompatibility, and the open volume in the tubes may be exploited as a drug release platform and so on. Therefore, in this study, Nanotube shape on the Ti-29Nb-xHf alloys with applied potentials was reserched. $TiO_2$ nanotube formation on Ti-29Nb-xHf alloys was carried out using anodization technique as a function of applied DC potential (10 V to 30 V and 30 V to 10 V) and anodization time for 60~120 min in $1MH_3PO_4$ with small additions of (0.8 wt. %, to 1.2 wt. %) NaF. The morphology change of anodized Ti-29Nb-xHf alloys was determined by FE-SEM, XRD, and EDS.

  • PDF

Application of Two Different Tracheal Stents in Small Toy Dogs with Tracheal Collapse

  • Piao, Zhenglin;Kim, Young-Ung;Kang, Jin-Su;Lee, Dong-Bin;Heo, Su-Young;Kim, Nam-Soo
    • 한국임상수의학회지
    • /
    • 제36권5호
    • /
    • pp.248-252
    • /
    • 2019
  • Tracheal collapse is a common respiratory disease in dogs. There are many ways to treat tracheal collapse, one of which is the use of an intraluminal stent. In this study, we divided 21 dogs into two groups and implant conventional stents and new nitinol stents. Comparison of two groups was based on following, feature of stent fracture, form of stent migration, clinical sign improvement, complication and prognosis. Approaching was established via C-arm under spontaneous breathing and placing a stent at the site of collapse. Using radiographic images, determine stent size accurately. For a comparison of identical condition, all intraluminal stents were placed 10 mm caudal from larynx to 10 mm cranial from carina. In this study, new nitinol stents improve the problems of conventional stents and may be effective in the treatment of tracheal collapse in small dogs.

수종의 흡수성 차단막의 생체 분해도와 조직학적 반응 (Resorbability and histological reaction of bioabsorbable membranes)

  • 석헌주;권석훈;김창성;최성호;전동원;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제32권4호
    • /
    • pp.781-800
    • /
    • 2002
  • The major goals of periodontal therapy are the functional regeneration of periodontal supporting structures already destructed by periodontal disease. There have been many efforts to develop materials and therapeutic methods to promote periodontal wound healing. With the development of non-resorbable membrane, GTR has proved to be the representive technique of periodontal regeneration. However, due to various clinical problems of non-resorbable membrane, resorbable membrane was developed and it showed to be clinically effective. The newly developed Para-Dioxanone membrane has a characteristic of non-woven fabric structures which is different from the generally used membranes with structure of mesh form. In addition, Chitosan membrane has been developed to apply its adventage maximally in GTR. Although a number of different types of membranes had been clinically used, researches on absorption rate of membranes were inadequate and limited to subjective opinions. However, since long term period of resorption and space maintenance are required in implant or ridge augmentation, accurate verification of resorption rate is clinically important. In this study, we had implanted Resolut(R), Biomesh(R), Para-Dioxanone membrane and Chitosan membrane (Size : 4mm ${\times}$ 4mm) on dorsal side of Sprague Dawley rat, and sacrified them after 4 weeks, 8 weeks, 12 weeks respectively. Histologic observation was carried out, and the following results were obtained by calculating the objective resorption rate. 1. In case of Resolut(R), external resorption took place initially, followed by internal resorption. Surface area are 5.76${\pm}$2.37$mm^2$, 4.90${\pm}$l.06$mm^2$, 4.90${\pm}$0.98$mm^2$ at 4 weeks, 8 weeks, 12 weeks respectively, and invasion rate of connective tissue to membrane are 31.6${\pm}$4.5%, 52.8${\pm}$9.4%, 56.4${\pm}$5.1% respectively. 2. Biomesh(R) showed a pattern of folding, relatively slow resorption rate with small size of membrane. Surface area are 3.62${\pm}$0.82$mm^2$, 3.63${\pm}$0.76$mm^2$, 4.07${\pm}$1.14$mm^2$ at 4 weeks, 8 weeks, 12 weeks respectively, and invasion rate of connective tissue to membrane are 26.1${\pm}$5.8%, 30.9${\pm}$3.4%, 29.2${\pm}$3.6%, respectively. 3. Para-Dioxanone membrane was surrounded by fibrous conncetive tissue externally, and resorption took place internally and externally. Surface area are 5.96${\pm}$1.05$mm^2$, 4.77${\pm}$10.76$mm^2$, 3.86${\pm}$0.84$mm^2$ at 4 weeks, 8 weeks, 12 weeks respectively, and invasion rate of connective tissue to membrane are 30.7${\pm}$5.1%, 53.3${\pm}$4.4%, 69.5${\pm}$3.1%, respectively. 4. Each fiber of Chitosan membrane was surrounded by connective tissue and showed external resorption pattern. It showed little invasion of inflammatory cells and excellent biocompatability. The resorption rate was relatively slow. Surface area are 6.01${\pm}$2.01$mm^2$, 5.49${\pm}$1.3$mm^2$, 5.06${\pm}$1.38$mm^2$ at 4 weeks, 8 weeks, 12 weeks respectively, and invasion rate of connective tissue to membrane are 31.3${\pm}$3.6%, 38.4${\pm}$3.80%, 39.7${\pm}$5.6%, respectively. Consequently, Para-Dioxanone membrane and Chitosan membrane are found to be clinically effective for their excellent tissue reaction and biocompatibility. Futhermore, the advantage of bone regenerating ability as well as the relatively long resorption period of Chitosan membrane, it might be widely used in implant or ridge augmentation.

HA-coated Zirconia의 생물학적 활성도에 관한 연구 (Biological Activities of HA-coated Zirconia)

  • 남석우;김해원;김현이;양승민;신승윤;이용무;정종평;한수부;최상묵;류인철
    • Journal of Periodontal and Implant Science
    • /
    • 제33권1호
    • /
    • pp.1-11
    • /
    • 2003
  • Hydroxyapatite(HA) has been extensively used as bone graft materials and tooth implant surface coating materials because of its biocompatibility and osteoconductive properties. However, as HA is intrinsically poor in mechanical properties, zirconia($ZrO_2$) was incorporated with HA as reinforcing phases for improvement of mechanical properties. The purpose of this study was to investigate the biological activities of HA-coated zirconia through the cell proliferation test, measurements of alkaline phosphatase activity, and histologic examination. Four kinds of tested blocks were prepared according to the pore size (300-500${\mu}m$/500-700${\mu}m$) and the porosity (70%/90%). Cell proliferation and alkaline phosphatase activity was measured at 1, 7, 14 days. The number of cells proliferate after 7, 14 days were significantly increased in all groups when compared with that of the first day, but there was no significant difference between the 4 groups at each time period. At the 7 day, alkaline phosphatase activities of cells cultured in 4 groups were higher than that of the first day, but there was no significant difference between the 4 groups at each time period. The human gingival fibroblast and MG 63 cell was used to evaluate the cell cytotoxicity using MTT test. The materials tested in the current study turned out to be non-cytotoxic. In histologic examination(SEM), at 1 day there were many cells attached on the surfaces of all kinds of tested blocks. The number of cells were increased over time. At the 14 day, there were more cells proliferated than 1 day and some of the pores of blocks were partially filled with the proliferated cells. The in vitro response of osteoblast-like cells to the HA-coated zirconia showed comparable effect on transformation comparable to hydroxyapatite.

나노구조 표면에 관한 문헌고찰 (A Literature Review on Nano-Modified Implant Surfaces)

  • 박고운;차민상;김대곤;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제29권2호
    • /
    • pp.141-151
    • /
    • 2013
  • 티타늄 산화막을 나노단위에서 변형시키는 방법은 다공성 표면을 강화하는 내부적 접근과 나노입자를 피복하는 외부적 접근으로 나눌 수 있다. 나노표면은 나노튜브, 나노피트, 나노노듈 및 다형구조 등 다양한 형태를 지닌다. 형성방법 및 형성재료에 따라 다른 표면이 생성되지만, 현재까지 표준화된 형성방법은 없다. 나노표면을 분석해 보면 마이크론 단위의 표면구조에는 영향을 미치지 않으며 전기화학적으로 안정적이다. 나노표면은 세포독성이 거의 없으며 조골세포의 증식과 분화를 모두 촉진하고, 섬유모세포의 증식을 저해하여 연조직 개재를 감소시키는 효과를 가진다. 또한 세포 및 단백질과 유사한 크기 및 형태를 가지기 때문에 조직과의 친화성이 우수하여 골유착을 증진시킨다. 하지만 그 작용이 미치는 범위는 극히 제한되어 있기 때문에 골조직과의 거리가 있는 경우에는 효과가 미미하다. 마이크론 단위의 표면과는 달리 나노표면은 광촉매효과로 인한 항균작용을 가지지만 지속시간이 짧아 실제 임상에서의 적용효과는 의문시 된다. 하지만 마이크론 단위의 표면거칠기가 가지는 단점을 배제할 수 있어 다양한 가능성을 가지기 때문에 더 많은 연구가 필요하다.

안와골절 정복술에 사용된 인공삽입물의 전산화단층촬영 추적관찰 (CT Observation of Alloplastic Materials Used in Blow Out Fracture)

  • 이원;강동희
    • Archives of Plastic Surgery
    • /
    • 제37권4호
    • /
    • pp.380-384
    • /
    • 2010
  • Purpose: Distinguishing different types of implants and assessing the position and size of implants by radiologic exam after orbital wall reconstruction is important in determining the surgery outcome and forecasting prognosis. We observed time-dependent density changes in three types of implants (porous polyethylene, resorbing plate and titanium mesh plate) by performing facial bone CT after orbital wall reconstructions. Methods: A total of 32 patients, who had underwent orbital wall fracture surgery from October 2006 to March 2009 and received facial bone CT as outpatients at 1 postoperative year were included in the study. Follow-up facial bone CT was performed on the patients pre- operatively, 1 month post-operatively, and 1 year post-operatively to observe the status of the orbital implants. Medpor $^{(R)}$ (Porex Surgical, Inc., Newnan, Ga.) was used as porous polyethylene and followed-up in 14 cases; for resorbing plate, Synthes mesh plate (Synthes, Oberdorf, Switzerland) was used in the reconstruction, and followed-up in 11 cases; and titanium mesh plate usage was followed-up in 7 cases. Computed tomographic scan (CT) and water's view were done for radiography, and hounsfield unit (HU) was used to compare density of those facial bone CT. Wilcoxon signed rank test was applied to statistically verify measurement difference in each group of hounsfield units. Results: Facial bone CT examination performed in 1 month post-operative showed that the density of porous polyethylene, resorbing plate and titanium mesh plate were -42.07, 105.67 and 539.48 on average, respectively. Among the three types of implants, titanium mesh plate showed the highest density due to its radiopaque feature. Following up the density of three types of implants in CT during 1 year after the orbital wall fracture surgery, the density of porous polyethylene increased in 10.52 House Field Units and the resorbing plate was decreased in 26.87 HouseField Units. There were no significant differences between densities in 1 month post-operatively and 1 year post-operatively in each group ($p{\geq}0.05$). Conclusion: We performed facial bone CT on patients with orbital fractures during follow-up period, distinguishing the types of implants by the different concentration of implant density, and the densities showed little change even at 1 year post-operative. To observe how implant densities change in facial bone CT, further studies with longer follow-up periods should be carried out.

Corrosion Behaviors of Dental Implant Alloy after Micro-sized Surface Modification in Electrolytes Containing Mn Ion

  • Kang, Jung-In;Son, Mee-Kyoung;Choe, Han-Cheol
    • Journal of Korean Dental Science
    • /
    • 제11권2호
    • /
    • pp.71-81
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the corrosion behaviors of dental implant alloy after microsized surface modification in electrolytes containing Mn ion. Materials and Methods: $Mn-TiO_2$ coatings were prepared on the Ti-6Al-4V alloy for dental implants using a plasma electrolytic oxidation (PEO) method carried out in electrolytes containing different concentrations of Mn, namely, 0%, 5%, and 20%. Potentiodynamic method was employed to examine the corrosion behaviors, and the alternatingcurrent (AC) impedance behaviors were examined in 0.9% NaCl solution at $36.5^{\circ}C{\pm}1.0^{\circ}C$ using a potentiostat and an electrochemical impedance spectroscope. The potentiodynamic test was performed with a scanning rate of $1.667mV\;s^{-1}$ from -1,500 to 2,000 mV. A frequency range of $10^{-1}$ to $10^5Hz$ was used for the electrochemical impedance spectroscopy (EIS) measurements. The amplitude of the AC signal was 10 mV, and 5 points per decade were used. The morphology and structure of the samples were examined using field-emission scanning electron microscopy and thin-film X-ray diffraction. The elemental analysis was performed using energy-dispersive X-ray spectroscopy. Result: The PEO-treated surface exhibited an irregular pore shape, and the pore size and number of the pores increased with an increase in the Mn concentration. For the PEO-treated surface, a higher corrosion current density ($I_{corr}$) and a lower corrosion potential ($E_{corr}$) was obtained as compared to that of the bulk surface. However, the current density in the passive regions ($I_{pass}$) was found to be more stable for the PEO-treated surface than that of the bulk surface. As the Mn concentration increased, the capacitance values of the outer porous layer and the barrier layer decreased, and the polarization resistance of the barrier layers increased. In the case of the Mn/Ca-P coatings, the corroded surface was found to be covered with corrosion products. Conclusion: It is confirmed that corrosion resistance and polarization resistance of PEO-treated alloy increased as Mn content increased, and PEO-treated surface showed lower current density in the passive region.

Single Device를 사용한 조도센서용 eFuse OTP IP 설계 (Design of eFuse OTP IP for Illumination Sensors Using Single Devices)

  • 에치크 수아드;김홍주;김도훈;권순우;하판봉;김영희
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.422-429
    • /
    • 2022
  • 조도센서 칩은 아날로그 회로의 트리밍이나 디지털 레지스터의 초기 값을 셋팅하기 위해 소용량의 eFuse(electrical Fuse) OTP(One-Time Programmable) 메모리 IP(Intellectual Property)를 필요로 한다. 본 논문에서는 1.8V LV(Low-Voltage) 로직 소자를 사용하지 않고 3.3V MV(Medium Voltage) 소자만 사용하여 128비트 eFuse OTP IP를 설계하였다. 3.3V 단일 MOS 소자로 설계한 eFuse OTP IP는 1.8V LV 소자의 gate oxide 마스크, NMOS와 PMOS의 LDD implant 마스크에 해당되는 총 3개의 마스크에 해당되는 공정비용을 줄일 수 있다. 그리고 1.8V voltage regulator 회로가 필요하지 않으므로 조도센서 칩 사이즈를 줄일 수 있다. 또한 조도센서 칩의 패키지 핀 수를 줄이기 위해 프로그램 전압인 VPGM 전압을 웨이퍼 테스트 동안 VPGM 패드를 통해 인가하고 패키징 이후는 PMOS 파워 스위칭 회로를 통해 VDD 전압을 인가하므로 패키지 핀 수를 줄일 수 있다.

수종의 치근면 처치 방법에 따른 상아질 지각 과민 변화 및 표면 특성에 관한 연구 (Study on the Changes of Dentinal Hypersensitivity and Surface Characteristics Following the Various Root Treatment)

  • 권순영;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제29권1호
    • /
    • pp.51-63
    • /
    • 1999
  • Exposure of the root surface due to gingival recession after periodontal surgery, elicit pain response when exposed to mechanical, heat, chemical or osmotic irritation. Especially patients treated with periodontal surgery, show high frequency. There have been reports that the 1 out of 7 patients complains of dentinal hypersensitivity. There have been many studies on the clinical effects of various materials on the treatment of dentinal hypersensitivity. The purposes of this study were to evaluate the effect of sodium chloride and potassium oxalate and to observe the relationship between the dentinal hypersensitivity and surface characteristics such as dentinal tubule size and number. This study included 20 teeth which were scheduled for extraction and had no pulpal disease. These teeth were divided into Root planing group, EDTA group, NaCl group and Oxalate group. Dentinal hypersensitivity is measured by tactile, pressured air and cold water using NRS (Numerical Rating Scales). Teeth were extracted under local anesthesia and each specimen was sectioned to a size about 3 X 5 mm and was examined under the scanning electron microscope (X2,000) The results were as follows, 1. The EDTA group exhibited significantly increased dentinal hypersensitivity comparing with the other groups. 2. The NaCl and Oxalate groups showed significantly reduced dentinal hypersensitivity comparing with the EDTA group. 3. As a method for dentinal hypersensitivity measurement, it was presumed thet tactile sensitivity test was not sensitive method but air blast test and cold water test were adequate method. 4. In a SEM study, the root planing group exhibited amorphous smear layer and showed no dentinal tubule orifice, but the EDTA group showed the large number of dentinal tubules. On the other hand, the NaCl and Oxalate groups did not show exposed dentinal tubules. The NaCl group showed more rough root surface than the EDTA group, and the Oxalate group showed many participates to be presumed as calcium oxalate particle. As the results from this study, root planing couldn't expose the dentinal tubule and NaCl and potassium oxalate occluded exposed dentinal tubule effectively. Dentinal hypersensitivity has close relationship with the exposure of dentinal tubules, especially with it's size and number.

  • PDF

($Denticheck^{(R)}$) 치솔의 규격, 특성 및 행태에 관한 연구 (Astudy On The Size, Characteristics And The Shape Of $Dentichek^{(R)}$ Toothbrush)

  • 문익상;김종관;채중규;조규성;최성호;이숭원
    • Journal of Periodontal and Implant Science
    • /
    • 제26권1호
    • /
    • pp.255-265
    • /
    • 1996
  • The purpose of the present study is to evaluate dimensional consistency, bristle finishes and bristle rebound rate of four brands of $Dentichek^{(R)}$ toothbrushes(regular-male, regular-female, soft-male, soft-female) to provide referneces in product enhancement and quality control for the manufacturer and to provide suggestions in selecting appropriate toothbrushes for general public. The results are as follows : 1. The size of the head is : $25.10{\times}8.10mm$ for male toothbrushes and $19.90{\times}8.10mm$ for male toothbrushes, while the size of the bristle portion is: $29.90{\times}10.65mm$ for male toothbrushes and $25.25{\times}10.65mm$ for female toothbrushes. 2. The length of the bristles is 10.70mm in all four groups. 3. The length of the toothbrush is 192mm in all four groups. 4. The number of tuft is 43 for male toothbrushes and 35 for female toothbrushes. Tuft arrangement is 4-row configuration in all four groups. 5. The number of bristles in a tuft ranges from 40-56, with higher numbers in male toothbrushes compared to the female counterparts, and higher numbers in the "soft" variety compared to the regular ones. 6. The diameter of the bristle is : 0.21mm for the outer row and 0.19mm for the inner row in the regular brand, and 0.17mm for the soft brand. 7. Irregularly finished bristle ends comprised 20-22% of the total bristles. 8. The bristle rebound rate ranges from 55.9% to 62.3%, with higher numbers in the "soft" variety compared to the regular ones. The above results show that $Dentichek^{(R)}$ toothbrushes meet the requirements of Korean Dental Association standards for toothbrushes, but further evaluations of their effects on periodontium and plaque elimination in actual in-use situation may be needed.

  • PDF