• 제목/요약/키워드: implant size

검색결과 293건 처리시간 0.02초

코헤시브 실리콘 젤 보형물을 이용한 유방확대술시 보형물 크기에 따른 유방 크기 변화 예측 (Predicting the Degree of Breast Size in Augmentation with Cohesive Gel Implant)

  • 이중호;서제원;이백권;오득영;이종원;안상태
    • Archives of Plastic Surgery
    • /
    • 제37권3호
    • /
    • pp.256-258
    • /
    • 2010
  • Purpose: Predicting the change in breast size for a specific patient's need is a challenging problem in breast augmentation. We intended to investigate the postaugmentation degree of breast size according to the size of cohesive silicone gel implant. Methods: To predict post-augmentation breast size, we measured 100 patients' pre-and postoperative 3 month's bust circumference. All patients were performed by total subfascial breast augmentation with moderate profile cohesive silicone gel implant through areolar omega (transareolar-perinipple) incision. Results: According to this study, each additional one pair of 100 mL in implant size yielded an approximate 1.5 cm increase in bust circumference (p=0.006). Conclusion: From this result, we conclude that each additional one pair of 100 mL in implant volume yielded about 1.5 cm increase in bust circumference. Although this result may not be applied to every patient, we believe that it yields a practical chart that can help to predict the amount of increase in breast size with the use of cohesive silicone gel implant of a specific size preoperatively.

확장성(더블루멘) 보형물을 이용한 유방확대술 (Breast Augmentation using Expandable Implants)

  • 심형보;남상재;윤상엽
    • Archives of Plastic Surgery
    • /
    • 제32권4호
    • /
    • pp.416-420
    • /
    • 2005
  • Ideal results of augmentation mammaplasty consist of symmetry, natural shape, soft feeling and inconspicuous scar. In addition, patient's preferences about size and shape should be included. Static implants could not perfectly satisfy patients' desires for size and shape, but expandable implants enable to change the volume after the operation. From September 2001 to September 2004, 76 patients(150 breasts) underwent breast augmentation using permanent expandable implant. The procedure was unilateral in 2 women and bilateral in 74 women. Age ranged from 19 to 50 years(mean, 29 years). Fifty nine patients underwent simple augmentation mammaplasty, 7 patients were corrected of their severe asymmetry, 2 patients with the congenital breast deformity underwent mammaplasty using this, and 2 patients who had undergone unilateral mastectomy were reconstructed of their breasts using expandable implant. There were no definite complications such as capsular contracture, implant rupture, asymmetry. And there reported little dissatisfaction about the size. The permanent expandable implants might be good alternatives in cases of ordinary breast augmentation as well as tissue deficient patients, asymmetry, congenital anomaly, and breast reconstruction.

삼차원 유한요소 해석에 의한 골내 임프란트의 구조에 관한 연구 (THREE-DIMENSIONAL FINI6E ELEMENT ANALYSIS OF THE ENDOSSEOUS IMPLANT DESIGNS)

  • 현연근;권종진
    • 대한치과보철학회지
    • /
    • 제35권1호
    • /
    • pp.181-210
    • /
    • 1997
  • The stress distribution generated in the surrounding bone was calculated and compared for various geometry of the dental implants by means of the finite element methods. The models were designed to represent the screw type endosseous implants(varing the size, shape, direction of the screw thread and the angle of the body) with supporting bone and the cylinder type endosseous implants(varing the lower portion-Round type, tapered type) with supporting bone. Static mean bite forces were applied 100N vertically and 25N horizontally on the center of the implant and three dimensional finite analysis was undertaken using software ANSYS 5.1 Version. The result demonstrated that different implant shape leads to significant variations in stress distribution in the bone. In the case of variation of the screw size, direction and shape the implant model with normally directional and triangular screw implied lower stress than with upper directional or lower directional and quadrangular screw but among models a different screw size, within a variation of 0.2mm there was no meaningful difference in maximum stress. In the case of variation of angle of body the straight implied lower stress than the tapered. As a result of analysis of cylinder type, the implants with larger radius of curvature of the round form and larger diameter of the tapered form implied lower stress.

  • PDF

사출성형 및 열간가압 소결법으로 제작된 지르코니아 세라믹 임플란트의 소결물성 및 미세구조적 결함 (Sintered Properties and Microstructural Defects of Zirconia Ceramic Implant Fabricated by Injection Molding and Hot Isostatic Pressing (HIP))

  • 박현정;박정식;이종국
    • 열처리공학회지
    • /
    • 제36권4호
    • /
    • pp.215-222
    • /
    • 2023
  • 3Y-TZP (3 mol% yttria-stabilized tetragonal zirconia polycrystals, 3Y-TZP) ceramics are emerging as dental implant materials due to their superior optical and mechanical properties as well as excellent biophysical properties, in spite of low bioactivity. In this study, we investigated to sintered properties and microstructural defects of dental zirconia implants fabricated by ceramic injection molding and post-HIP (Hot isostatic pressing) processing and analyzed the processing parameters related with the obtainment of its high sinterd density. Sintered and microstructural parameters, i.e, apparent density, grain size and phase composition of zirconia implants fabricated by injection molding were dependent on the fixtute size and implant type. Maximum sintered density of 99.2% and minimum grain size of 0.3-0.4 ㎛ were obtained from large-scaled 2-body sample. In 1-body ceramic implant, high sintered density of 99.5% was obtained, but it had a little monoclinic phase and wide grain size distribution.

임플란트 지지 고정성 치과 보철물 유지방식에 따른 고정체의 직경과 길이 분포 비교 연구 (A comparative study of the distribution of implant fixtures according to length and diameter by retained type of implant-supported fixed prosthesis)

  • 김욱태
    • 대한치과기공학회지
    • /
    • 제28권2호
    • /
    • pp.347-353
    • /
    • 2006
  • The Purpose of this study was to compare the distribution of implant fixtures according to length and diameter between screw-retained and cement-retained implant-supported fixed prosthesis and to asses whether prosthesis retained types affected the selection of size of implant fixtures. This study presents a follow-up 2,416 implant-supported fixed type prosthesis that have been screw retained or cemented retained for about 10 years in 14 dental clinics. Included in the study were 458 men and 397 women and implant fixtures used in this study were screw retained type 1,057 and 1,359 of cemented retained type. The statistical results among the diameter types of fixture by prosthesis retained type was no significant difference noted (P= 0.809) and there was significant differences was enough to among the lengths of fixture by prosthesis retained type (P= 0.020). However there were no significant difference among the fixture diameter types and length by prosthesis retained type (P= 0.486). So there was not affected to prostheis fixation mechanism for the size of implant fixtures.

  • PDF

임플란트 주위 골 결손부의 이식재 크기에 따른 재생 효과 비교 연구 (The comparative study - the regenerative effect depends on size of bone graft material in bone loss site around dental implant)

  • 오흥균;홍기석;정진형;임성빈
    • Journal of Periodontal and Implant Science
    • /
    • 제38권3호
    • /
    • pp.493-502
    • /
    • 2008
  • Purpose: The purpose of this study is to investigate on the regenerative capacity by using different size of graft materials around bony defect around implant. Material and Methods: Dental implant fixtures(Bio-TIS, Korea) were placed into the tibia of 8 rabbits. After placement of implant, artificial defects were created for each group, and the size of bone graft materials were used according to each designated group. 4 weeks after surgery, 8 rabbits were sacrificed. The histologic and histomorphometrical study were done for comparison of the regenerative capacity using $80-90{\mu}m$ and $200{\sim}1000{\mu}m$ size of grafting materials of OCS-$B^{(R)}$. Result: Matured bone formation was significantly increased more in Group E1($80-90{\mu}m$) than in Group E2($200{\sim}1000{\mu}m$). Group E1($80-90{\mu}m$) showed more significant augmentation in marginal length of graft material per unit area than Group E2($200{\sim}1000{\mu}m$). Group E1($80-90{\mu}m$) showed more interspace in graft material than Group E2($200{\sim}1000{\mu}m$). Control group showed no new bone formation around and inside of implanted fixture. Conclusion: Small grafting material size has great influence on bone regeneration.

임플랜트 지대주의 삭제과정이 결합부 안정성에 미치는 영향 (THE EFFECT OF PREPARATION PROCEDURE ON IMPLANT-ABUTMENT JOINT STABILITY)

  • 이장욱;김창회;장경수;임영준
    • 대한치과보철학회지
    • /
    • 제43권5호
    • /
    • pp.662-670
    • /
    • 2005
  • Statement of problem: Little is known about the effect of abutment preparation procedure on do-torque values in different implant platform and the relationship of final do-torque values with different implant platform size. Purpose: This study evaluated the effect of abutment preparation procedure on do-torque values in different implant platform and the relationship of final do-torque values with different implant platform size. Material and method: Six ITI implants (2 narrow-neck implants, 2 regular-neck implants, 2 wide-neck implants) and six Branemark implants (2 narrow platforms, 2 regular platforms, 2 wide platforms) were embedded in each acrylic resin block with epoxy resin. Eighteen $synOcta^(R)$ abutments (6 narrow-neck implant-abutments, 6 regular-neck implant-abutments, 6 wide-neck implant-abutments) and eighteen esthetic abutments (6 narrow platform-abutments, 6 regular platform-abutments, 6 wide platform-abutments) were tightened to each implant with digital torque gauge. Initial do-torque values were measured using digital torque gauge. After preparation of abutments, Final do-torque values were measured with digital torque gauge. Results and conclusion: 1. Screws loosening or abutments motion were not detected in all experimental group, but some scratches of implant-abutment joints were detected in all group 2. Reduction ratios of final do-torque values were greater than initial do-torque values in all measured group, except in narrow-neck implant-abutment group (p<0.05). 3. Reduction ratios of final do-torque values in wide-neck implant-abutment group were greater than regular-neck implant-abutment group (p<0.01). 4. The greatest standard deviation value was detected in wide platform group in both implant systems.

공극률에 따른 다공성 타이타늄 임플란트의 기계적 특성 (Mechanical properties of the porous Ti implants according to porosity)

  • 김영훈
    • 대한치과기공학회지
    • /
    • 제37권2호
    • /
    • pp.57-62
    • /
    • 2015
  • Purpose: This study was performed to investigate mechanical properties of the porous Ti implants according to porosity. Porous Ti implant will be had properties similar to human bone such as microstructure and mechanical properties. Methods: Porous Ti implant samples were fabricated by sintering of spherical Ti powders(below $25{\mu}m$, $25{\sim}32{\mu}m$, $32{\sim}38{\mu}m$, and $38{\sim}45{\mu}m$) in a high vacuum furnace. Specimen's diameter and height were 4mm and 40 mm. Surface and sectional images of porous Ti implants were evaluated by scanning electron microscope(SEM). Porosity and average pore size were evaluated by mercury porosimeter. Young's modulus and tensile strength were evaluated by universal testing machine(UTM). Results: Porosity of Implant was increased according to larger particle size of the powder. Boundary portions of particles are sintered fully and others portions were formed pore. Young's modulus was decreased by formed porous structure. Tensile strength was decreased according to larger the particle size of the powder, but higher than human bone. Conclusion: If prepared by adjust the porosity of the porous Ti implant will be able to resolve the stress shielding phenomenon.

Influence of implant-abutment connection structure on peri-implant bone level in a second molar: A 1-year randomized controlled trial

  • Kim, Jin-Cheol;Lee, Jungwon;Kim, Sungtae;Koo, Ki-Tae;Kim, Hae-Young;Yeo, In-Sung Luke
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권3호
    • /
    • pp.147-154
    • /
    • 2019
  • PURPOSE. This study aimed to evaluate the effect of two different implant-abutment connection structures with identical implant design on peri-implant bone level. MATERIALS AND METHODS. This clinical study was a patient-blind randomized controlled trial following the CONSORT 2010 checklists. This trial was conducted in 24 patients recruited between March 2013 and July 2015. Implants with internal friction connection were compared to those with external hex connection. One implant for each patient was installed, replacing the second molar. Implant-supported crowns were delivered at four months after implant insertion. Standardized periapical radiographs were taken at prosthesis delivery (baseline), and one year after delivery. On the radiographs, distance from implant shoulder to first bone-to-implant contact (DIB) and peri-implant area were measured, which were the primary and secondary outcome, respectively. RESULTS. Eleven external and eleven internal implants were analyzed. Mean changes of DIB from baseline to 1-year postloading were 0.59 (0.95) mm for the external and 0.01 (0.68) mm for the internal connection. Although no significant differences were found between the two groups, medium effect size was found in DIB between the connections (Cohen's d = 0.67). CONCLUSION. Considering the effect size in DIB, this study suggested the possibility of the internal friction connection structure for more effective preservation of marginal bone.

생쥐의 유선발달에 있어서 Elvax 40P Implant를 이용한 서방형 Adenosine의 역할 (Effect of Sustained-Release of Adenosine by Elvax 40P Implant on Mouse Mammary Development)

  • 여인서;박춘근;홍병주
    • 한국가축번식학회지
    • /
    • 제16권4호
    • /
    • pp.387-397
    • /
    • 1993
  • To examine local response of adenosie(purine nucleoside) on the developing mammary gland, Elvax 40P implants containing adenosine were surgically implanted into mammary fat pad of the five week old female ICR mice. Inguinal(the 4th) mammary glands of anesthetized mice were exposed andplaced the implants for 12 days. One gland was treated with an adenosine implant, while the contralateral gland received a blank implant as control. For whole-mount preparations, glands were stained with alum carmine, and for histological observation, micro-selected mammary glands were stained with hematoxylin and eosin Y. Implantation with Elvax 40P did not affect on the damage of neighboring mammary tissue. Adenosie 25 or 250$\mu\textrm{g}$ per slow-release implant stimulated local mammary end bud formation of ovariectomized mice such as end bud size and numbers of end bud per gland in a dose dependent manner(P<0.05), and lower concentration of adenosie(2.5 or 25$\mu\textrm{g}$/implant) increased numbers of end bud(P<0.05) and end bud size(P<0.1) of intact mice. Adenosine treatment and intact ovarian function had moderate interation effects on the stimulation of end bud formation at 2.5$\mu\textrm{g}$ adenosine/implant(P<0.1). In histological observation, adenosine implants increased numbers of mammary epithelial type of cells at mammary duct in the presence or absece ofovary. These results indicate that adenosine should be one of regulators in mouse mammary ductal growth.

  • PDF