Marginal bone loss between internal- and external- abutment connection type implants placed in the first molar area (제1대구치 위치에 식립된 단일 임플란트의 지대주 연결 유형에 따른 임플란트 주위골 흡수)

  • Seok-Hyun Lee;Eun-Woo Lee;Ha-Na Jung;Ok-Su Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.1
    • /
    • pp.32-44
    • /
    • 2023
  • Purpose: The purpose of this study was to investigate the effect of implant connection type on marginal bone loss (MBL) and to analyze the factors that affect MBL. This study focuses on single implants planted in the upper and lower first molar area. Materials and Methods: A total of 87 implants from 68 patients were tracked for a period over 5 years. There were 57 external connection type (EC) implants and 30 internal connection type (IC) implants in 38 males and 30 females. The MBL and EA were measured from intraoral radiograph images taken after 5 years at most. Results: Significant difference in MBL between EC and IC type was observed in patients without GBR or diabetes. Patients without GBR exhibited an MBL of -0.065 ± 0.859 mm in EC type and -0.627 ± 0.639 mm in IC type (P = 0.025). Using multiple regression analysis, a statistically significant negative correlation was observed between MBL and conditions including implant-abutment connection type (β = -0.303), diabetes (β = -0.113), emergence angle > 30° (β = -0.234), and age (β = -0.776). Conclusion: Within this results, IC type implants had less MBL than EC type, and implant prosthesis with emergence angle over 30° showed greater MBL. To minimize the MBL of the implant and ensure implant stability, careful consideration should be given to the EA of implant prosthesis and its connection type.

The methods for occlusal force measurement and their clinical applicatio (임상가를 위한 특집 3 - 교합력 측정의 방법과 임상적 적용)

  • Park, Ji-Man;Heo, Seong-Joo;Chun, Yoon-Sic
    • The Journal of the Korean dental association
    • /
    • v.50 no.1
    • /
    • pp.22-30
    • /
    • 2012
  • The methods for the occlusal force measurement have long been developed. The occlusal analyzing equipment utilizing the pressure-sensitive film (Prescale) is useful for the assessment and comparison among large group of patients. On the other hand, the apparatus which uses the grid-based sensor sheet (T-scan) can be a useful assistant for acquiring the well-balanced occlusion. The device that can process the electrical input from the strain gauge which is attached to the tooth surface can collect the dynamic data of actual masticatory force. This device has been developed for the measurement of actual mastication with the food bolus and it can be a useful method for the comparison before and after the restorative treatment. Occlusal force measurement can be applied for the analysis of therapeutic action, diagnosis of crack- tooth syndrome, temporomandibul ar disease, and idiopathic implant loosening.

Intracrevicular restoration and dentogingival junction(DGJ);Part: restorative contour and DGJ (치은열구내 수복과 Dentogingival junction(DGJ);제 2 부:수복물형태와 DGJ)

  • Lee, Young-Kyoo;Son, Seong-Heui
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.117-130
    • /
    • 1999
  • All contours of the restoration not directly related to occlusion are related to the gingival tissues only.And proper contour of restoration is essential for the health of the periodontal tissues.But there are so many controversies about the contour of the restoration, and there is no uniform agreement in the literature as to which contour of restoration is best for periodontium. In general, the contour of restoration means the supragingival contour only but in the case of the intracrevicular restorative procedure the subgingival contour of restoration must be considered. Because a portion of the restoration is placed in a gingival sulcus which is extremely vulnerable to periodontal disease. In this article the concepts or theories of the supragingival contour, the subgingival contour, and the emergence profile were discussed.The contour of the restoration and the biotype of the periodontium must be considered in intracrevicular restorative procedure.And sufficient tooth preparation is important factor to develop the proper contour of restoration which is kind to periodontium.

  • PDF

Posterior maxillary segmental osteotomy for management of insufficient intermaxillary vertical space and intermolar width discrepancy: a case report

  • Baeg, SeungWoo;On, SungWoon;Lee, JeongKeun;Song, SeungIl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.28.1-28.6
    • /
    • 2016
  • Backgrounds: Insufficient intermaxillary space is caused by non-restoration following tooth extraction in the past, and this involves eruption of the opposing teeth and changes of the arch structure. Such cases are difficult just by a simple prosthetic approach, and diversified treatment plans should be established. Among these, posterior maxillary segmental osteotomy (PMSO) is an efficient treatment option than extraction of opposing teeth as it surgically repositions multiple erupted teeth and alveolar bone. PMSO can preserve the natural teeth; therefore, it is being regarded as a treatment method which can improve insufficient intermaxillary space significantly. Case presentation: In this case report, the first patient received PMSO in order to place an implant in the mandibular edentulous space after decreased vertical dimension is restored, and the second patient received PMSO along with orthodontic treatment to obtain the intermaxillary space and balance the interarch molar width. Conclusion: PMSO is the treatment of choice when occlusion is compromised in the presence of decreased vertical dimension or arch length discrepancy.

Rescue of a periodontally compromised tooth by non-surgical treatment: a case report

  • Cho, Young-Dan;Kim, Sungtae;Koo, Ki-Tae;Seol, Yang-Jo;Lee, Yong-Moo;Rhyu, In-Chul;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.128-134
    • /
    • 2016
  • Purpose: This article describes a case of the successful non-surgical management of a periodontally compromised maxillary premolar. Methods: A combination therapy, including root planing, occlusal adjustment, and tooth splinting, was applied. Clinical and radiographic examinations were performed during the 16-month follow-up period. Results: All periodontal parameters were improved. There were dramatic decreases (3-6 mm) in the probing pocket depth, tooth mobility, and marginal bone loss. Interestingly, gradual resolution of the periapical radiolucency and alveolar bone regeneration were observed in the radiographs, and the periodontal condition was maintained during the follow-up period. Conclusions: Within the limits of this study, these results demonstrate the importance of natural tooth preservation through proper periodontal treatment and occlusal adjustment of the periodontally compromised tooth, which is typically targeted for tooth extraction and dental implantation.

Tensile Strength of Provisional Cement on Natural Abutment and Metal Abutment (자연 지대치와 금속 지대치 상에서 임시 접착제의 인장력에 관한 연구)

  • Lee, Il-Kwon;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • STATEMENT OF PROBLEM: Tensile strength of metal crown cemented with provisional cement have shown clinically difference between metal abutment of implant and natural abutment. PURPOSE: This study was tested to compare the tensile strength of provisional cement on the natural abutment and metal abutment. MATERIAL AND METHODS: Out of the 20 premolars that were selected for this experiment, each 10 were prepared of abutments by chamfer and rounded shoulder margin and then duplicated to produce 20 metal abutments that were same to natural teeth. Then, crowns were fabricated to fit the total 40 natural & metal abutments to be cemented by cavitec, to be added of regular, repetitive vertical load, and to be measured of tensile strength by using Universal Test Machine. RESULTS: There was statistically significant difference in the tensile strength between the crowns cemented to the natural & metal abutments, but no statistically significant difference was observed between the chamfer and the shoulder gingival margin of the each abutments. CONCLUSIONS: Tensile strength of metal teeth is greater about 2 more times than that of natural teeth when it is cemented with Cavitec.

Restoration of Subgingivally Fractured Upper Incisor (치은 연하로 파절된 상악 전치부의 수복)

  • Kim, Ja-Yeong;Lee, Hong-Seok;Ahn, Seung-Geun;Park, Ju-Mi;Song, Kwang-Yeob;Park, Charn-Woon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.301-307
    • /
    • 2006
  • The subgingival fracture near the alveolar bone is difficult to treat. This fractured tooth will be treated by many methods. First approach is to preserve the fractured tooth. Periodontal surgery has been used to lengthen the clinical crown, thereby allowing the tooth to be restored. Another method is erupting the tooth with orthodontic eruption (forced eruption) or surgical extrusion. Second approach is the restoration after extraction of the subgingivally fractured tooth. This is restorative with conventional fixed partial denture or implant. This article presents the variable restorative approach of subgingivally fractured upper incisor.

The FEM Analysis on the Crestal Cortical Bone around the Implant according to the Cancellous Bone Density and Loading Positions (임프란트 매식시 해면골질의 차이에 따른 치밀골 상 응력분석)

  • Jeung, Sin-Young;Kim, Chang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • This study was performed to compare the stress distribution pattern in the crestal cortical bone and cancellous bone using 3-dimensional finite element stress analysis when 2 different Young's modulus(high modulus, model 1; low modulus, model 2) of cancellous bone was assumed. For the analysis, a finite element model was designed to have two square-threaded implants fused together and located at first and second molar area. Stress distribution was observed when vertical load of 200N was applied at several points on the occlusal surfaces of the implants, including central fossa, points 1.5mm, 2mm, 3mm and 3.5mm buccally away from central fossa. The results were as follows; 1. In both model, the maximum Von-Mises stress in the crestal cortical bone was greater when the load was applied at the central point, points 1.5mm and 2mm buccally away from central fossa than other cases. 2. In the cortical bone around first and second molar, model 2 showed greater Von-Mises stress than model 1. It is concluded that when the occlusal contact is afforded, the distribution of stress varies depending on the density of cancellous bone and the location of loading. More favorable stress distribution is expected when the contact load is applied within the diameter of fixtures.

The Comparison of the Accuracy upon the Manual Torque Generating Devices for the Implant (임플란트에 사용되는 수동 토크발생장치의 정확성 비교)

  • Kim, Dong-Hwan;Kim, Han-Su;Oh, Sang-Ho;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.227-237
    • /
    • 2007
  • Various methods and torque generating devices are developed and employed to apply proper torque clinically. In this study, clinically used torque control devices are measured whether uniformed and precise torque are generated. Digital torque gauge are employed for measurement and torque driver, torque limiting device, torque indicating device are used for torque generating devices. ${\chi}^2$ distribution was formed and One-way ANOVA(Turkey test) was performed to measure torque values generated by each torque generating device. In the results, all companies have been shown slight errors and deviations. This indicates a difficulty of applying precise torque. Therefore, it would be recommended torque generating device should be checked whether uniformed and precise torque can be generated and an error should be corrected.

Management of open bite that developed during treatment for internal derangement and osteoarthritis of the temporomandibular joint

  • Arai, Chihiro;Choi, Jae Won;Nakaoka, Kazutoshi;Hamada, Yoshiki;Nakamura, Yoshiki
    • The korean journal of orthodontics
    • /
    • v.45 no.3
    • /
    • pp.136-145
    • /
    • 2015
  • This case report describes the orthodontic treatment performed for open bite caused by internal derangement (ID) and osteoarthritis (OA) of the temporomandibular joint (TMJ). A Japanese woman, aged 31 years and 11 months, referred to our department by an oral surgeon had an open bite with clockwise rotation of the mandible and degeneration of the condyle. The overbite was corrected through intrusion of the maxillary and mandibular molars using mini-screw implants to induce counterclockwise rotation of the mandible. Then, the mandibular second premolars were extracted and comprehensive orthodontic treatment was performed to establish a Class I molar relationship with distalization of the maxillary arch and to eliminate anterior crowding. Following treatment, her facial profile improved and a functional and stable occlusion was achieved without recurrence of the TMJ symptoms. These results suggest that orthodontic intrusion of the molars is one of the safer and less stressful alternatives for the management of open bite due to degeneration of the condyles caused by ID and OA of TMJ.