• Title/Summary/Keyword: implant failure

Search Result 305, Processing Time 0.025 seconds

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

A Biomechanical Analysis of Various Surgical Procedures for Osteonecrosis of the Femoral Head using a Finite Element Method (유한요소법을 이용한 대퇴 골두내 무혈성 괴사증의 다양한 수술적 기법에 대한 생체역학적 분석)

  • Kim, J.S.;Lee, S.J.;Shin, J.W.;Kim, Y.S.;Choi, J.B.;Kim, Y.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.374-378
    • /
    • 1997
  • Operative procedures such as core drilling with and without fibular bone grafting have been recognized as the treatment methods for osteonecrosis of femoral head(ONFH) by delaying or preventing the collapse of the femoral head. In addition, core drilling with cementation using polymethylmethacrylate (PMMA) has been proposed recently as another surgical method. However, no definite treatment modality has been found yet while operative procedures remain controversial to many clinicians In this study, a finite element method(FEM) was employed to analyze and compare various surgical procedures of ONFH to provide a biomechanical insight. This study was based upon biomechanical findings which suggest stress concentration within the femoral head may facilitate the progression of the necrosis and eventual collapse. For this purpose, five anatomically relevant hip models were constructed in three dimensions : they were (1) intact(Type I), (2) necrotic(Type II), (3) core drilled only(Type III), (4) core drilled with fibular bone graft(Type IV), and (5) core drilled with cementation(Type V). Physiologically relevant loading were simulated. Resulting stresses were calculated. Our results showed that the volumetric percentage subjected to high stress in the necrotic cancellous region was greatest in the core drilled only model(Type III), followed by the necrotic(Type II), the bone graft (Type IV), and the cemented(Type V) models. Von Mises stresses at the tip of the graft(Type IV) was found to be twice more than those of cemented core(Type V) indicating the likelihood of the implant failure. In addition, stresses within the cemented core(Type V) were more evenly distributed and relatively lower than within the fibular bone graft(Type IV). In conclusion, our biomechanical analyses have demonstrated that the bone graft method(Type IV) and the cementation method(Type V) are both superior to the core decompression method(Type III) by reducing the high stress regions within the necrotic cancellous bone. Also it was found that the core region filled with PMMA(Type V) provides far smoother transfer of physiological load without causing the concentration of malignant stresses which may lead to the failure than with the fibular bone graft(Type IV). Therefore, considering the above results along with the degree of difficulties and risk of infection involved with preparation of the fibular bone graft, the cementation method appears to be a promising surgical treatment for the early stage of osteonecrosis of the femoral head.

  • PDF

Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants (치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구)

  • Kim, Hee-Eun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.209-223
    • /
    • 2013
  • This study was to evaluate the stress distributions of prefabricated, customized abutments and fixtures according to their material and shape by three-dimensional finite element analysis. And to investigate the fatigue life and fracture characteristics. Mandibular models were fabricated by reconstruction of the CT scan of patients with normal occlusion. A total of six finite element models were designed, a load of 100 N was applied on the buccal cusps vertically, and 30 degree obliquely. 10 specimens each were fabricated for the more clinically widely used 4 type abutments and were loaded according to ISO 14801. Differences in stress distribution patterns were not found according to the materials of the abutments and fixtures. But a slight difference in the stress level was detected. Customized abutment groups showed lower crown stress levels. One-piece zirconia implant showed the lowest bone stress levels. In the fatigue test, highest values were measured in group 7. Prefabricated abutments showed less variation of fatigue life (P<0.05). Use of customized abutments can improve the fracture resistance of restorations. Especially, use of customized zirconia abutments reinforced by titanium screw connecting parts is recommended.

EFFECT ON THE OSTEOGENESIS OF DENTAL IMPLANTS AFTER HORIZONTAL DISTRACTION OSTEOGENESIS WITH NITRIFIED DISTRACTOR (질화 표면처리된 신장기를 이용한 수평적 치조골신장술 후 임플란트 식립시 골유착 효과에 관한 연구)

  • Park, Chul-Min;Kim, Su-Gwan;Kim, Hak-Kyun;Moon, Seong-Yong;Oh, Ji-Su;Baik, Sung-Mun;Lim, Sung-Chul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.225-231
    • /
    • 2008
  • This study evaluated whether there is a difference between a conventional titanium distraction device and a TiN-coated device in terms of implant osseointegration after horizontal distraction osteogenesis in narrow alveolar bone. Four adult mongrel dogs, each weighing $9{\sim}10kg$, were used in this study. The lower premolars were extracted and horizontal distraction was performed with conventional titanium distraction devices (group 1) or TiN-coated devices (group 2). After an 8-week consolidation period, the implants were installed, and the dogs were sacrificed after another 8 weeks. The osseointegration around the implants was evaluated histomorphologically. There was one failure in experimental group 1 because of fracture of the device. Direct bone contact was achieved and there were no significant differences between the control group and experimental groups 1 and 2 in terms of osseointegration around the implants at 8 weeks. In summary, intraoral distraction osteogenesis is a good option for augmenting severely atrophied alveolar ridges, and the TiN-coated device may be useful because of its advantages, which include surface hardness, corrosion resistance, and reduced bacteria.

A clinical study of iliac bone graft using subperiosteal tunneling method for alveolar ridge augmentation (심하게 흡수된 치조제의 증강을 위한 골막하 터널링기법을 이용한 장골이식술에 대한 임상연구)

  • Park, Soong;Jung, Jun-Ho;Kim, Yeo-Gab;Kwon, Yong-Dae;Choi, Byung-Joon;Ohe, Joo-Young;Lee, Baek-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.427-433
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate the efficacy of the subperiosteal tunneling technique with iliac block bone graft for bone augmentation in an edentulous alveolar ridge. Patients and Methods: Total of 8 sites in 7 patients were included in this study. The bone height was evaluated by CBCT preoperatively and 4 months after operation. Total of 11 implants were inserted and evaluated clinically and radiographically. Results: Mean value of the increased bone height was 6.29 mm and no implant failure was observed. There were no complications such as soft tissue dehiscence, exposure of the grafted bone and infection. Conclusion: We have achieved excellent clinical outcomes by this technique, so we concluded that it is useful for augmentation of severely deficient alveolar ridge.

Infective Endocarditis Involving Aortic Valve, Mitral Valve, Tricuspid Valve, and luterventricular Septum -A Case Report (대동맥판막, 승모판막, 삼첨판막과 심실중격을 침범한 심내막염 -1예 보고-)

  • 박종빈;서동만
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.200-204
    • /
    • 1997
  • This is a report of a successful management of a patient with infective endocarditis involving native aortic valve, mitral valve, tricuspid valve, and Interventric lar septum. A 16 year-old patient who underwent VSD patch closure, and aortic valvuloplasty at the age of 1 1 years showed Intractable congestive heart failure during antibiotics treatment for infective endocarditis. Operative findings revealed that there were large defect along the previous patch, aortic regurgitation with multiple perforations and vegetations, mitral regurgitation with vegetation, aortic paraannular abscess, interventricular myocardial abscess, and tricuspid regurgitation with perforations and vegetations. We reconstructed the interventricular defect with Dacron patch extending to the aortic valve annulus after radical debridement of all infected or devitalized tissues, and could implant aortic valve by anchoring to the reconstructed Dacron patch. Mitral valve was replaced and tricuspid valve was repaired with patient's own pericardium. The patient was discharged after antibiotics treatment for 6 weeks and in good condition without any sequelae for 12 months.

  • PDF

NFlex Dynamic Stabilization System : Two-Year Clinical Outcomes of Multi-Center Study

  • Coe, Jeffrey D.;Kitchel, Scott H.;Meisel, Hans Jorg;Wingo, Charles H.;Lee, Soo-Eon;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.6
    • /
    • pp.343-349
    • /
    • 2012
  • Objective : Pedicle-based dynamic stabilization systems, in which semi-rigid rods or cords are used to restrict or control spinal segmental motion, aim to reduce or eliminate the drawbacks associated with rigid fusion. In this study, we analyzed the two-year clinical outcomes of patients treated with the NFlex (Synthes Spine, Inc.), a pedicle-based dynamic stabilization system. Methods : Five sites participated in a retrospective study of 72 consecutive patients who underwent NFlex stabilization. Of these 72 patients, 65 were available for 2-year follow-up. Patients were included based on the presence of degenerative disc disease (29 patients), degenerative spondylolisthesis (16 patients), lumbar stenosis (9 patients), adjacent segment degeneration (6 patients), and degenerative lumbar scoliosis (5 patients). The clinical outcome measures at each assessment were Visual Analogue Scale (VAS) to measure back pain, and Oswestry Disability Index (ODI) to measure functional status. Radiographic assessments included evidence of instrumentation failure or screw loosening. Results : Sixty-five patients (26 men and 39 women) with a mean age of 54.5 years were included. Mean follow-up was 25.6 months. The mean VAS score improved from 8.1 preoperatively to 3.8 postoperatively, representing a 53% improvement, and the ODI score from 44.5 to 21.8, representing a 51% improvement. Improvements in pain and disability scores were statistically significant. Three implant-related complications were observed. Conclusion : Posterior pedicle-based dynamic stabilization using the NFlex system seems effective in improving pain and functional scores, with sustained clinical improvement after two years. With appropriate patient selection, it may be considered an effective alternative to rigid fusion.

Short Segment Fixation for Thoracolumbar Burst Fracture Accompanying Osteopenia : A Comparative Study

  • Kim, Hyeun Sung;Kim, Seok Won;Ju, Chang Il;Lee, Sung Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.1
    • /
    • pp.26-30
    • /
    • 2013
  • Objective : The purpose of this study was to compare the results of three types of short segment screw fixation for thoracolumbar burst fracture accompanying osteopenia. Methods : The records of 70 patients who underwent short segment screw fixation for a thoracolumbar burst fracture accompanying osteopenia (-2.5< mean T score by bone mineral densitometry <-1.0) from January 2005 to January 2008 were reviewed. Patients were divided into three groups based on whether or not bone fusion and bone cement augmentation procedure 1) Group I (n=26) : short segment fixation with posterolateral bone fusion; 2) Group II (n=23) : bone cement augmented short segment fixation with posterolateral bone fusion; 3) Group III (n=21) : bone cement augmented, short segment percutaneous screw fixation without bone fusion. Clinical outcomes were assessed using a visual analogue scale and modified MacNab's criteria. Radiological findings, including kyphotic angle and vertebral height, and procedure-related complications, such as screw loosening or pull-out, were analyzed. Results : No significant difference in radiographic or clinical outcomes was noted between patients managed using the three different techniques at last follow up. However, Group I showed more correction loss of kyphotic deformities and vertebral height loss at final follow-up, and Group I had higher screw loosening and implant failure rates than Group II or III. Conclusion : Bone cement augmented procedure can be an efficient and safe surgical techniques in terms of achieving better outcomes with minimal complications for thoracolumbar burst fracture accompanying osteopenia.

A 3D-printing Bone Model for Surgical Planning of Total Hip Replacement after Failed Triple Pelvic Osteotomy

  • Han, Kyungjin;Park, Jiyoung;Yoon, Jangwon;Lee, Young-Won;Choi, Ho-Jung;Jeong, SeongMok;Lee, Haebeom
    • Journal of Veterinary Clinics
    • /
    • v.34 no.6
    • /
    • pp.463-466
    • /
    • 2017
  • A 3-year-old, 26 kg, castrated male Chow Chow was presented for assessment of weight-bearing lameness of the left hind limb. The patient had a history of triple pelvic osteotomy on the left side to correct hip dysplasia 2 years prior to his presentation of clinical signs and underwent total hip replacement on the right coxofemoral joint 1 year later. Upon physical examination, pain and crepitus were noted on the left hip joint during extension. Radiological examination revealed coxofemoral joint subluxation and moderate degenerative bone changes on the left hip joint and pelvic axis, which relates to acetabular angles that were changed after triple pelvic osteotomy (TPO). Preoperative computed tomography was used for 3-dimensional printing to establish an accurate surgical plan. The changed angles of the acetabulum after TPO were evaluated, and rehearsal surgery was performed using a 3-demensional printing bone model. Three months after the THR surgery, the function of the affected limb had improved, with no lameness. Complications, such as luxation and implant failure, were not observed until 6 months after the operation. Accurate evaluation of acetabulum angles and rehearsal surgery using a 3D-printed bone model is effective for total hip replacement after unsuccessful TPO.

Charlson comorbidity index as a predictor of periodontal disease in elderly participants

  • Lee, Jae-Hong;Choi, Jung-Kyu;Jeong, Seong-Nyum;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.2
    • /
    • pp.92-102
    • /
    • 2018
  • Purpose: This study investigated the validity of the Charlson comorbidity index (CCI) as a predictor of periodontal disease (PD) over a 12-year period. Methods: Nationwide representative samples of 149,785 adults aged ${\geq}60$ years with PD (International Classification of Disease, 10th revision [ICD-10], K052-K056) were derived from the National Health Insurance Service-Elderly Cohort during 2002-2013. The degree of comorbidity was measured using the CCI (grade 0-6), including 17 diseases weighted on the basis of their association with mortality, and data were analyzed using multivariate Cox proportional-hazards regression in order to investigate the associations of comorbid diseases (CDs) with PD. Results: The multivariate Cox regression analysis with adjustment for sociodemographic factors (sex, age, household income, insurance status, residence area, and health status) and CDs (acute myocardial infarction, congestive heart failure, peripheral vascular disease, cerebral vascular accident, dementia, pulmonary disease, connective tissue disorders, peptic ulcer, liver disease, diabetes, diabetes complications, paraplegia, renal disease, cancer, metastatic cancer, severe liver disease, and human immunodeficiency virus [HIV]) showed that the CCI in elderly comorbid participants was significantly and positively correlated with the presence of PD (grade 1: hazard ratio [HR], 1.11; P<0.001; grade ${\geq}2$: HR, 1.12, P<0.001). Conclusions: We demonstrated that a higher CCI was a significant predictor of greater risk for PD in the South Korean elderly population.