• Title/Summary/Keyword: implant failure

Search Result 305, Processing Time 0.025 seconds

Analysis of longevity and success rate of fixed, removable, and implant prostheses treated in Korea (국내에서 치료된 고정성, 가철성, 그리고 임플란트 보철물의 수명 및 성공률 분석)

  • Yoon, Joon-Ho;Park, Young-Bum;Oh, Nam-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.95-104
    • /
    • 2018
  • Purpose: The purpose of this study is to analyze the factors affecting the longevity of failed prosthesis and the success rate of the prosthesis based on the data evaluated with the newly developed Korean Academy of Prosthodontics (KAP) criteria. Materials and methods: Evaluation was performed in the restored prosthesis for patients who visited the prosthodontics department of the 13 dental university hospitals and general hospitals. The status of the prosthesis was classified into four categories: Good, Fair, Bad, Worst. The success was recorded if only the category was classified in 'good'. The mean duration of failed prostheses and the success rate through Kaplan-Meier method were analyzed. Results: A total of 1,804 cases of prosthesis were evaluated: 810 cases of fixed dental prostheses (FDP), 519 cases of Removable Dental Prostheses (RDP), and 475 cases of implant prosthesis. The mean duration of failed FDP was $11.41{\pm}0.30years$ and the median was 10 years. The mean duration of failed RDP was $8.18{\pm}0.29years$ and the median was 7 years. The mean duration of failed implant prosthesis was $7.99{\pm}0.30years$ and the median was 7 years. The factors related to the failure were as follows: number of units, abutments, abutments treated with root canal, and plaque index in FDPs; treated and opposing dentition in RDPs; the number of implants, duration of use, and plaque index in implant prostheses. Conclusion: The average duration of failed prosthesis was 11.41 years for FDPs, 8.18 years for RDPs, and 7.99 years for implant prosthesis, according to the evaluation with newly developed KAP criteria.

EFFECTS OF DIFFERENT OXIDIZED SURFACES OF IMPLANT ON OSSEOINTEGRATION; RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS STUDY IN MINI-PIGS (다양한 양극산화막 처리방법이 임플란트 골유착에 미치는 영향)

  • Kwon, Kyung-Hwan;Min, Seung-Ki;Sung, Dae-Hyuk;Choi, Jae-Young;Choi, Seung-Lim;Cha, Su-Ryeon;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.5
    • /
    • pp.383-393
    • /
    • 2007
  • The aim of the present study is to investigate the effect of anodized surface of osseointegration implants by using of resonance frequency analysis (RFA) and histomorphometric analysis. A total of 96 screw-shaped implants were devided into 4 groups. Seventy-two implants were prepared by electrochemical oxidation with 3 different ways; Group 1 (n=24) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid, Group 2 (n=24) were prepared at galvanostatic mode in calcium glycerophosphate and calcium acetate, and Group 3 (n=24) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid followed by Calcium metaphosphate(CMP) coating. Control group (n=24) were the RBM surfaced implants. The implants were placed in the mandibles of 12 mini pigs. Bone tissue responses were evaluated by resonance frequency analysis(RFA) and histomorphometric analysis that were undertaken at 2, 4 and 6weeks after implant placement. The following result were obtained. 1. Twenty-two of 96 implants (4 in control group, 5 in group 1, 7 in group 2, and 6 in group 3) were failed due to faliure of osseoitegration. The failure rate of osseointegration was 22.9%. 2. The mean values of RFA in control, group 2 and groups 3 showed the similar values, but there was no significant difference among groups. 3. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact ratio in group 2 at 3 and 4 weeks after implant placement than other groups (p<0.05), but there was no significant difference among groups at 6weeks after implant placement.

Optimized Implant treatment strategy based on a classification of extraction socket defect at anterior area (전치부에서 발치와 골결손부에 따른 최적의 심미를 얻을 수 있는 수술법)

  • Ban, Jae-Hyuk
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.15-24
    • /
    • 2016
  • It is considered an implant failure when there is esthetic problems in the anterior area although the prosthesis function normally. In 2003, Dr. Kan et al stated that implant bone level is determined by the adjacent teeth. After that many scholars have studied how can achieve the esthetics result on adjacent teeth bone loss cases. In 2012, Dr. Takino published an article in Quintessence. He summarized previous articles and reclassified the defects from class 1 through 4. Class 1 and 2 depicts a situation where there is no bone loss on adjacent teeth. In Class 3 and 4, interproximal bone loss extends to the adjacent tooth. If one side is involved, it is Class 3. If both sides are involved, it is Class 4. The clue for esthetic implant restoration is whether bone loss extends to adjacent tooth or not. If the bone level of adjacent tooth is sound, we can easily achieve the esthetic but the bone level is not sound, the surgery will be complicated and the esthetic result will be unpredictable. So regenerative surgery for adjacent tooth is necessary for long-term maintenance. But the options and process were so complicated, the purpose of this article is to report the method simplify the surgery and gain a similar outcome.

Etiology and Treatment of Revision Shoulder Arthroplasty (견관절 인공관절 재치환술의 원인과 치료)

  • Kim, Young-Kyu;Jung, Kyu-Hak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.100-109
    • /
    • 2019
  • The rapidly increasing rate of shoulder arthroplasty is certain to increase the number of revision arthroplasties because of parallel increases in complication numbers. It has been widely reported that the causes of revision shoulder arthroplasty include rotator cuff deficiency, instability, glenoid or humeral component loosening, implant failure, periprosthetic fracture, and infection. Revision arthroplasty can be technically challenging, and surgical options available for failed shoulder arthroplasty are limited, especially in patients with glenoid bone loss or an irreparable rotator cuff tear. Furthermore, the outcomes of revision arthroplasty are consistently inferior to those of primary arthroplasty. Accordingly, surgical decision making requires a good understanding of the etiology of failure. Here, we provide a review of indications of revision arthroplasty and of the surgical techniques used by failure etiology.

Alveolar ridge preservation using granulation tissue for esthetic implant restoration on maxillary anterior tooth (상악 전치부의 심미적 임플란트 수복을 위한 육아 조직(Granulation tissue)을 이용한 치조제 보존술)

  • Lee Chang Kyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.1
    • /
    • pp.16-22
    • /
    • 2023
  • Esthetic factors are very important in the success of maxillary anterior implant restoration. However, achieving esthetic results is difficult, especially in cases where periodontitis has resulted in severe alveolar bone loss. In the case of maxillary anterior teeth, the alveolar ridge resorption that begins immediately after tooth extraction interferes with the esthetic implant restoration. Therefore immediate implant placement can be performed to minimize the alveolar ridge resorption. However, in severe bone loss cases, immediate implant placement could result in esthetic failure, and this result might cause irreparable problems. We can also perform alveolar ridge preservation and then place implants later. On JCP published in 2019, there is the consensus of European academy of periodontology on the extraction socket management and the timing of implant placement. This consensus states that alveolar ridge preservation should be considered when there is severe labial bone loss in an esthetically important area such as maxillary anterior region. On performing the alveolar ridge preservation, we cannot obtain the primary wound closure, so secondary wound healing is induced with open membrane technique or soft tissue grafting should be performed for primary wound closure. However, the secondary wound healing can have a negative impact on bone regeneration, and soft tissue grafting such as FGG or CT graft can be burdensome for both patients and dentists. On the other hand, by using the granulation tissue in the extraction socket, primary closure can be achieved without soft tissue grafting. Also some studies have shown that granulation tissue in periodontal defects contains stem cells that may help in tissue regeneration. Based on this, implant restorations were performed on maxillary anterior teeth with severe alveolar bone loss by alveolar ridge preservation using granulation tissue. In spite of the severe bone defect of the extraction socket, relatively esthetic results could be obtained in implant restorations.

Floating septum technique: easy and safe method maxillary sinus septa in sinus lifting procedure

  • Jung, Junho;Hwang, Bo-Yeon;Kim, Byung-Soo;Lee, Jung-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.54.1-54.3
    • /
    • 2019
  • Background: The presence of septa increases the risk of Schneiderian membrane perforation during sinus lift procedure, and therefore, the chance of graft failure increases. We present a safe method of managing septa and, in particular, overcoming small and palatally located septa. Methods: After the elevation of the flap and the creation of a small bony window positioned anterior to the septum, the Schneiderian membrane is lifted carefully. A thin and narrow osteotome is then placed at the indentation created at the base of the septum, and mobilization of the septum is achieved by gentle malleting. The membrane is again carefully lifted up behind the septum. Results: There was one small membrane perforation case in all 16 cases, and none of these patients showed postoperative complications such as implant failure, infection, or maxillary sinusitis. Conclusions: This technique is useful for overcoming the problem of maxillary sinus septa hindering the sinus floor elevation procedure, leading to fewer complications.

Stress distribution in bone surrounding maxillary molar implants under different crown-to-fixture ratio: A 3D FEM analysis (치관/고정체 비에 따른 상악 구치부 임플란트 주변골의 응력 분포에 대한 3차원 유한요소법적 분석)

  • Park, Jong-Chan;Shin, Sang-Wan;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.479-489
    • /
    • 2008
  • Statement of the problem: Under anatomical limitations on maxillary posterior region, a poor crown-to root ratio acting on dental implants can result in undesirable stress in surrounding bone, which in turn can cause bone defects and eventual failure of implants. Purpose: The purpose is to compare stress distribution due to different crown-root ratio and effect of splinting between natural teeth and implants in maxillary molar area under different loads. Material and methods: Analysis of stress arising supporting bone of the natural teeth and the implant was made with 3-dimensional finite element method. The model simulated naturel teeth was made with 2nd premolar and 1st molar in the maxillary molar region (Model T). The model simulated implants placed on same positions with two parallel implants of Straumann Dental Implant cemented abutment (Model I). Each model was designed in different crown-root ratio (0.7:1, 1:1, 1.25:1) and set cement type gold crown to make it non-splinted or splinted. After that, 300 N force was loaded to each model in five ways (Load 1: middle of occlusal table, Load 2: middle of buccal cusp, Load 3: middle of lingual cusp, Load 4: horizontal load to buccal cusp of anterior abutment only, Load 5: horizontal load to middle of buccal cusp of each abutment), and stress distribution was analyzed. Results and conclusion: On all occasions, stress was concentrated at the cervical region of the implant. Under load 1, 2 and 3, stress was not increased even when crown-root ratio increases, but under load 4 and 5, when crown-root ratio increases, stress also increased. There was difference in stress values between natural teeth and implants when crown-root ratio gradually increases; In case of natural teeth, splinting decreased stress under vertical and horizontal loads. In case of implants, splinting decreased stress under vertical loads 1,2 and 3, but increased maximal stress under loads 2 and 3. Under horizontal loads, splinting decreased stress, however the effect of splinting decreased under load 5 than load 4. Furthermore, the stress was increased, when crown-root ratio is 1.25:1. Clinical implications: This limited finite element study suggests that the stress on supporting bone may be increased under non-axial loads and poor crown-root ratio. Under poor crown-root ratio, excessive stress was generated at the cervical region of the implant, and decreased splinting effect for stress distribution, which can be related to clinical failure.

Influence of Implant Fixture-Abutment Connection and Abutment Design on Mechanical Strength (임플란트 고정체-지대주 연결부 및 지대주 디자인이 기계적 강도에 미치는 영향)

  • Chun, Mi-Hyun;Jeong, Chang-Mo;Jeon, Young-Chan;Eom, Tae-Gwan;Yoon, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.269-281
    • /
    • 2008
  • Fatigue or overload can result in mechanical problems of implant components. The mechanical strength in the implant system is dependent on several factors, such as screw and fixture diameters, material, and design of the fixture-abutment connection and abutment. In these factors, the last rules the strength and stability of the fixture-abutment assembly. There have been some previous reports on the mechanical strength of the fixture-abutment assembly with the compressive bending test or short-term cyclic loading test. However, it is restrictive to predict the long-term stability of the implant system with them. The purpose of this study was to evaluate the influence of the design of the fixture-abutment connection and abutment on the mechanical strength and failure mode by conducting the endurance limit test as well as the compressive bending strength test. Tests were performed according to a specified test(ISO/FDIS 14801) in 4 fixture-abutment assemblies of the Osstem implant system: an external butt joint with Cemented abutment (group BJT), an external butt joint with Safe abutment (group BJS), an internal conical joint with Solid abutment (group CJO), and an internal conical joint with ComOcta abutment (group CJT). The following conclusions were drawn within the limitation of this study. Compressive bending strengths were decreased in order of group BJS(1392.0N), group CJO(1261.8N), group BJT(1153.2N), and group CJT(1110.2N). There were no significant differences in compressive bending strengths between group BJT and group CJT(P>.05). Endurance limits were decreased in order of group CJO(600N), group CJT(453N), group BJS(360N), and group BJT(300N). 3. Compressive bending strengths were influenced by the connection and abutment design of the implant system, however endurance limits were affected more considerably by the connection design.

A Numerical Study on the Response of the Tibial Component in Total Knee Arthroplasty to Longitudinal Impact (인공무릎관절 전치환술에 있어 축방향 충격에 의한 Tibial Component의 응답 특성 분석 연구)

  • 조용균;조철형;최재봉;이태수;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.503-511
    • /
    • 1998
  • In this study, the stress distribution for different tibial components was observed In order to Investigate the load transfer and potential failure mechanism of the tibial components subjected to dynamic impact loading and also to evacuate the effect of bone-implant bonding conditions on the implant system. The 3-dimensional finite element models included an intact tibia, cemented metal-backed tibial component, uncemented metal-blocked tibial component, cemented all-polyethylene tibial component, and metal-backed component with a debonded bone/stem interface. The results showed that the cemented metal-hocked component Induced slightly higher peak stress at stem tip than the uncemented component. The peak stress of the all-polyethylene tibia1 component at stem trip showed about half thats of metal-backed tibial components. The all-polyethylene component showed a similar dynamic response to intact tibia. In case of debonded bone/stem interface, the peak stress below the metal tray was three times Higher than that of the fully bonded interface and unstable stress distribution at the stem tip was observed with time, which causes another adverse bone apposition and implant loosening. Thus, the all-polyethylene tibial component bonded fully to the surrounding bone might be most desirable system under an impact loading.

  • PDF

A 5-year retrospective clinical study of the Dentium implants

  • Lee, Jeong-Yol;Park, Hyo-Jin;Kim, Jong-Eun;Choi, Yong-Geun;Kim, Young-Soo;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.229-235
    • /
    • 2011
  • PURPOSE. The aim of this retrospective study was to evaluate cumulative survival rate (CSR) of Implantium implants followed for 5 years and association between risk factors and the CSR. MATERIALS AND METHODS. A total of two hundred forty-nine Implantium Implants System (Dentium, Seoul, Korea) placed in ninety-five patients from 2004 to 2009 were investigated with several identified risk factors (sex, systemic disease, smoking, alchohol, reason of tooth loss, length, arch (maxilla or mandible), replace tooth type (incisor, canine, premolar or molar) Kennedy classification, prosthodontic type, prosthodontic design, opposite dentition, abutment type, occlusal material, occlusal unit, splint to tooth, cantilever, other surgery). Clinical examination (mobility, percussion, screw loosening, discomfort, etc.) and radiographic examination data were collected from patient records including all problems during follow-up period according to protocols described earlier. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR. RESULTS. Five of 249 implants were failed. Four of these were lost before loading. The 5-year implant cumulative survival rate was 97.37%. Cox regression analysis demonstrated a significant predictive association between overall CSR and systemic disease, smoking, reason of tooth loss, arch, Kennedy classification and prosthodontic design (P<.05). The screw related complication was rare. Two abutment screw fractures were found. Another complications of prosthetic components were porcelain fracture, resin facing fracture and denture fracture (n=19). CONCLUSION. The 5-year CSR of Implantium implants was 97.37 %. Implant survival may be dependent upon systemic disease, smoking reason of tooth loss, arch, Kennedy classification and prosthodontic design (P<.05). The presence of systemic diseases and combination of other surgical procedures may be associated with increased implant failure.