• 제목/요약/키워드: impinger

검색결과 22건 처리시간 0.018초

공기중 이소시아네이트류의 측정 및 분석방법에 관한 비교연구 (A Comparison of Sampling and Analytical Methods for Airborne Isocyanates)

  • 변혜정;윤충식;백남원
    • 한국환경보건학회지
    • /
    • 제22권2호
    • /
    • pp.32-42
    • /
    • 1996
  • This study was performed to evaluate accuracy and precision of filter method and impinger method for analyzin airborne isocyanates in mixture (2, 6-TDI, HDI, 2, 4-TDI, MDI). Filter method was performed using the OSHA Method 42 and impinger method using the NIOSH Method 5521. The samples were analyzed by high performance liquid chromatography-ultraviolet detector (HPLC-UVD). After the optimum operating conditions for each method were investigated, samples with various concentration levels were quantified at the conditions. The precision was expressed by the pooled coefficient of variation(C.V.) and the accuracy by overall accuracy. The results are summarized as follows: 1. The optimum condition of filter method was determined at 35/65 ACN/buffer (0.01 M ammonium acetate) in mobile phase. And in case of impinger method, it was at 30/70 ACN/buffer(0.2 M sodium acetate). The effect of concentrations of acetate on the separation of the peaks was not significant, but, the effect of ACN/buffer ratio was significant. 2. The correlation coefficients for the two methods were above 0.9 in all isocyanate compounds. Average recovery efficiencies for 2, 6-TDI, HDI, 2, 4-TDI and MDI in filter method were 92.4%, 102.6%, 87.3% and 101.0%, respectively. Those in impinger method were 106.6%, 106.7%, 99.0% and 103.6%, respectively. As a result, the recovery efficiency of impinger method was higher than those of filter method in analyzing isocyanate compounds. 3. The pooled coefficients of variations of the methods were slightly higher than expected. The overall accuracies of the methods were within $\pm 25%$ for each isocyanate compound. Since these results satisfy NIOSH criteria, the accuracy of the experiment is appropriate. 4. As seen above, impinger method is more efficient than filter method. But, there are many disadvantages in impinger method. Therefore, solid sorbent such as a glass fiber filter must be developed in order to have the high efficiency not less than that of impinger method in the future.

  • PDF

능동포집법과 확산포집법에 의한 작업환경 중 포름알데히드 농도 비교 (Comparison of formaldehyde concentration in working environment between passive sampling method and impinger sampling method)

  • 함성애;문덕환
    • 한국산업보건학회지
    • /
    • 제16권4호
    • /
    • pp.346-355
    • /
    • 2006
  • The purpose of this study was conducted to ascertain the difference between impinger and passive sampling methods in the process of sampling and analyzing on airborne formaldehyde. Formaldehyde generating workplaces included in this study comprised four types of manufacturing industry such as two workplaces of products of wood, cork, straw and plaiting materials manufacturing industries, one casting metal manufacturing industry, and one parts and accessories for motor vehicles and it′s engines manufacturing industry. Workplaces contained in this study were located in some manufacturing area of Busan industrial complex and this study was carried out during a period from January 2003 to December 2004. Analytical accuracy, precision and detection limit of two methods was compared. Exposure level of its airborne concentration was evaluated in formaldehyde generating workplaces those were classified by types of industry, working process, and time. The results were as follows ; 1. A rate of recovery was 107.1% in impinger method and 101.8% in passive method, and precision was 7.79% in impinger method and 4.40% in passive method. There was no statistical significance in analytical accuracy and precision between two methods. A limitation of detection was 0.011 ppm in passive method which was lower than that of impinger method (0.020 ppm) by 1.8 times. 2. Airborne formaldehyde concentration of impinger method was different from passive method. It′s concentration by passive method was higher by 5.1 times than that by impinger method in the parts and accessories for motor vehicles and it′s engines manufacturing industry (P<0.05). Only in molding process among several types of processes, formaldehyde concentration in passive method was higher by 5.1 times than that in impinger method (P<0.05). Furthermore, formaldehyde concentration in passive method was higher by 1.7 times than that in impinger method (P<0.05) in the first half of year 2003. 3. The geometric mean of formaldehyde concentration in impinger method was lower than that in passive method, but there was no statistical significance of formaldehyde concentration by the difference of sampling method. In conclusion, it is difficult to conclude which is better between the two sampling methods because of no statistical significance for the difference of concentration. Because of lacks of certified passive sampling and analytical method, at present situation, studies on verification of accuracy and precision, obstructive reaction against validity on its exposure assessment, and research to develop domestically manufactured passive sampler in terms of cost-effectiveness should be continuously carried out.

수증기 동위원소 측정을 위한 저온채집법에 대한 연구 (Applications of Cryogenic Method to Water Vapor Sampling from Ambient Air for Isotopes Analysis)

  • 김송이;한영철;허순도;이정훈
    • Ocean and Polar Research
    • /
    • 제38권4호
    • /
    • pp.339-345
    • /
    • 2016
  • Stable water vapor isotopes have been utilized as a tracer for studying atmospheric global circulations, climate change and paleoclimate with ice cores. Recently, since laser spectroscopy has been available, water vapor isotopes can be measured more precisely and continuously. Studies of water vapor isotopes have been conducted over the world, but it is the early stage in south Korea. For vapor isotopes study, a cryogenic sampling device for water vapor isotopes has been developed. The cryogenic sampling device consists of the dewar bottle, filled with extremely low temperature material and impinger connected with a vacuum pump. Impinger stays put in the dewar bottle to change the water vapor which passes through the inside of impinger into the solid phase as ice. The fact that water vapor has not sampled completely leads to isotopic fractionation in the impinger. To minimize the isotopic fractionation during sampling water vapor, we have tested the method using a serial connection with two sets of impinger device in the laboratory. We trapped 98.02% of water vapor in the first trap and the isotopic difference of the trapped water vapor between two impinger were about 20‰ and 6‰ for hydrogen and oxygen, respectively. Considering the amount of water vapor trapped in each impinger, the isotopic differences for hydrogen and oxygen were 0.33‰ and 0.06‰, respectively, which is significantly smaller than the precision of isotopic measurements. This work can conclude that there is no significant fractionation during water vapor trapping.

시료채취 방법에 따른 작업 공정별 Toluene diisocyanates 포집농도 비교 (Comparison of Toluene Diisocyanate Concentrations Collected with Different Sampling Methods by Work Process)

  • 김성호;원종욱;김치년;정우진;노재훈
    • 한국산업보건학회지
    • /
    • 제23권2호
    • /
    • pp.95-102
    • /
    • 2013
  • Objectives: The aim of this study is to present an appropriate sampling method for individual exposure assessment based on a comparison of toluene diisocyanate (TDI) concentrations collected through different sampling methods by work process type. Methods: Two plants handling TDIs in the Incheon area were selected. The samplings were taken during respective processes of spray painting, drying, grinding, and foaming, in which the production of TDIs took on different forms. For the sampling methods for airborne TDIs, open-face cassette holder, modified 2-piece cassette holder, and impinger were used, and the sampling was performed simultaneously at the same locations. Results: The comparison of TDI collection concentrations by each process depending on the sampling method showed high concentrations in the order of the impinger, modified 2-piece cassette holder, and open-face cassette holder for spray painting and foaming. In all processes with the exception of drying, TDI collection concentrations were higher for sampling done with the modified 2-piece cassette holder than with the open-face cassette holder. Conclusions: Based on these results, the modified 2-piece cassette holder was found to be a more appropriate sampling method than the open-face cassette holder when taking individual samples of TDIs from spray painting, grinding, and foaming processes. In particular, for individual exposure assessment of the spray painting process, which features comparatively high collection concentrations compared to the other processes, the use of a modified 2-piece cassette holder is considered appropriate.

공기중 6가 크롬 측정 방법 비교 -검출한계, 정확도 및 정밀도- (Comparison of Sampling and Analytical Methods for Determining Airborne Hexavalent Chromium -Limit of Detection, Accuracy and Precision of Analytical Procedures)

  • 신용철;이병규;이지태
    • 한국대기환경학회지
    • /
    • 제18권1호
    • /
    • pp.39-49
    • /
    • 2002
  • In this study, limits of detection (LOD), accuracy and precision of four sampling/ analytical methods were evaluated and compared for the determination of airborne hexavalent chromium, Cr (VI). The methods include : (1) a combination of the National Institute for Occupational Safety and Health (NIOSH) Method 7600/U. S. Environmental Protection Agency (EPA) Method 218.6 (NIOSH/EPA Method) proposed by Shin and Paik, 2) two impinger methods using 2% NaOH/3% Na$_2$CO$_3$. (3) same as (2) but with 0.02 N NaHCO$_3$absorbing solution, and (4) the Occupational Safety and Health (OSHA) Method ID-215. An ion chromatograph/visible absorbance detector was used for the analysis of Cr (VI) in sample solution. Limit of detection (LOD) , analytical accuracy, and precision were also tested using Cr (VI) spike samples. Recoveries (as index of accuracy) and coefficient of variation (CV) (as a index of precision) were determined. Two-way ANOVA and Turkey's test were performed to test the significance in differences among recoveries and CVs of the methods. In all the methods, the peaks of Cr (VI) were separated sharply on chromatograms and exhibited a strong linearity with Cr (VI) concentrations in solution. The correlation coefficients of calibration curves typically ranged from 0.9997 to 0.9999, and the analytical LODs from 0.025 to 0.1$\mu\textrm{g}$/sample. All the method had good sensitivities and linearities between Cr (VI) levels and peak areas. The accuracies (% mean recoveries) of the methods ranged from 80.1 to 104.2%, while the precisions (pooled coefficient of variation) ranged from 3.16 to 4.43%. The impinger methods showed higher recoveries ( > 95%) than those of the PVC filter methods (the OSHA Method and the NIOSH/EPA Method). It was assumed that Cr (VI) on PVC filter was exposed to air and reduced to trivalent chromium, Cr (III), whereas it was stabilized in alkali solution contained in impinger. Thus, a special treatment of Cr (VI) samples collected on PVC filters may be required.

미스트중 6가 크롬 측정을 위한 IC/Visible Spectrophotometry 방법 (Shin & Paik′s Method)의 현장 평가 (Field Validation of an IC/Visible Spectrophotometry Method for the Determination of Cr(VI) in Mist)

  • 신용철;백남원;김상우;김선자;이유미
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.40.1-43
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of hexavalent chromium, Cr(VI) in mist from field plating operation. The Procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute for Occupational Safety and Health (NIOSH) Method 7600, and the filter sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(VI) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(VI) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(VI) on PVC filters and storing the sample filters in screw-capped vials according to the NIOSH method, and analyzing Cr(VI) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(VI) into 0.02 MN/sub a/Hco₃ solution in midget impinger, and analyzing the Cr(VI) in samples using IC/VS. The third method was the OSHA Method Id-215. Using these four different methods, four replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and Paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r/sup 2/=0.99) between Cr(VI) concentrations measured by the shin & Paik's Method and an impinger method (p>0.05). However, Cr(VI) concentrations determined by Shin & Paik's Method were Significantly different form those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(VI) concentrations of Shin & Paik's Method were Significantly higher than those of the NIOSH/EPA Method or the OSHA method. We concluded that the Shin & Paik's Method could prevent Cr(VI) losses caused by reduction and give more reliable results of airborne Cr(VI) concentrations in work environments.

  • PDF

PVC 여과지에서의 환원 방지를 위해 개발된 공기중 6가 크롬 측정방법의 현장 평가 (Field Validation of a Sampling and Analytical Method Developed for Preventing Airborne Hexavalent Chromium Collected on PVC Filter from Reduction)

  • 신용철;백남원
    • 한국환경보건학회지
    • /
    • 제28권2호
    • /
    • pp.109-116
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of airborne hexavalent chromium, Cr(Ⅵ), in a field plating operation. The procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute iota Occupational Safety and Health (NIOSH) Method 7600, and the filler sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(Ⅵ) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(Ⅵ) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(Ⅵ) on PVC filters and storing the sample filters in strew-capped vials according to the NIOSH method, and analyzing Cr(Ⅵ) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(Ⅵ) into 0.02 M NaHCO₃ solution in midget impinger, and analyzing the Cr(Ⅵ) in samples using IC/VS. The third method was the OSHA Method ID-215. Using these four different methods, lour replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r²:0.99) between Cr(Ⅵ) concentrations measured by the Shin & Paik's Method and an impinger method (p>0.05). However, Cr(Ⅵ) concentrations determined by Shin & Paik's Method were significant1y different from those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(Ⅵ) concentrations of Shin & Paik's Method were significantly higher than those of the NIOSH/EPA Method or the OSHA method. This result indicated that the Shin & Paik's Method may prevent Cr(Ⅵ) losses caused by reduction and give more reliable results of airborne Cr(Ⅵ) concentrations in work environments.

능동포집과 확산포집법에 의한 일부합판제조업의 공정별 포름알데하이드 농도 비교 (Comparison of Active and Passive Sampling Methods for Formaldehyde Concentrations Among Workplaces in Some Plywood Industries)

  • 장미;김현욱
    • 한국산업보건학회지
    • /
    • 제6권1호
    • /
    • pp.17-27
    • /
    • 1996
  • This study was designed to survey exposure levels of formaldehyde among workplaces in some plywood industries and to compare three sampling methods including the impinger method(IM, NIOSH method No. 3500), the solid sorbent tube method(SS, NIOSH method No. 2541), and the passive bubbler monitor method(PB, SKC). The survey was conducted in seven particle board manufacturing factories, two resin manufacturing factories and two plywood manufacturing factories in Incheon area during the period from March 6 to April 20, 1995. The workplaces included were the hot/cold press, the roller/spreader, the soaking/drying, and the reaction/mixing areas. The results were as follows; 1. The average(GM, GSD) concentrations of formaldehyde by sampling methods were 0.11(4.43) ppm by IM, 0.27(2.03) ppm by SS, and 0.29(2.04) ppm by PB, respectively. The concentrations by 1M method were statistically very significantly lower than those of SS and PB methods, particularly at low air borne concentrations of formaldehyde (p<0.001). 2. The area average concentrations of formaldehyde by workplaces measured with PB bubblers were 0.23(2.08) ppm from the press, 0.23(1.77) ppm from the spreader, 0.24(1.51) ppm from the soaking, and 0.46(1.96) ppm from the reaction areas, respectively. The personal average concentrations of formaldehyde by workplaces measured with PB bubblers were 0.30(1.77) ppm from the press, 0.33(1.54) ppm from the spreader, 0.36(1.46) ppm from the soaking, and 0.84(1.19) ppm from the reaction areas, respectively. 3. No statistically significant differences of formaldehyde concentrations among workplaces except the reaction area(p<0.001) were found. 4. Formaldehyde concentrations from personal samples were higher than those of from area sam pies in all workplaces studied. But no statistically significant differences of formaldehyde concentrations both area and personal samples were found. In conclusion, this study found that although formaldehyde concentrations in some plywood industries in Incheon area were below the regulatory limit of 1 ppm, they were over the limits recommended by NIOSH and ACGIH. This study also suggests that the impinger method may underestimate true formaldehyde concentrations. It implies that there will be more workplaces not meeting current regulatory limit if either the solid sorbent or passive bubbler methods were used instead of the impinger method. It is suggested that passive monitors will be a reasonable alternative for area and personal sampling of formaldehyde if the accuracy and validity of passive monitors be verified before use.

  • PDF

단일 노즐 및 멀티-노즐 가상 임팩터의 성능평가 (Performance Evaluation on Single Nozzle and Multi-Nozzle Virtual Impactors)

  • 김대성;김민철;이규원
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2000년도 추계학술대회 논문집
    • /
    • pp.59-60
    • /
    • 2000
  • 에어로졸을 분리할 수 있는 장비로는 전기적 이동차 분석기(differential mobility analyzer), 싸이클론(cyclone), 습식 충돌기(impinger), 습식 싸이클론(wet cyclone), 확산 배터리(diffusion battery), 관성 임팩터(inertial impactor), 그리고 가상 임팩터(virtual impactor) 등이 있다. 이중 가상 임팩터는 설계 및 제작이 비교적 간편하고, 입자를 분리 및 농축하는데도 좋은 성능을 나타냄으로 널리 사용되어져 왔다. (중략)

  • PDF

매립가스내 규소화합물류 검출을 위한 용매선택에 관한 연구 (Solvent Selection for the Detection of Siloxanes in Landfill gas)

  • 김낙주;최주미;지은정
    • 대한환경공학회지
    • /
    • 제29권8호
    • /
    • pp.915-921
    • /
    • 2007
  • 본 연구는 매립가스내 siloxanes 측정의 기초 연구로서 국내 매립지를 대상으로 하여 용매흡수법으로서의 최적 용매를 선정하고자 수행하였으며, n-hexane, acetone 및 methanol을 흡수용매로 하여 각 용매의 siloxanes 검출 특성을 비교 분석하였다. 연구결과 표준물질의 GC분석에서 사용된 3가지 흡수용매 중 methanol이 용매와 silane 피크의 겹침현상이 발생하지 않아 분리능이 가장 우수하게 나타났다. 검출되는 siloxanes 농도는 흡수용매에 따라 최대 2.6배의 농도차를 보였으며, 포집유속과 포집 임핀저 단수에 대한 의존성에 대해서도 높은 것으로 나타났다. Methanol은 siloxanes 총 농도가 가장 높을 뿐만 아니라 휘발성이 적어 임핀저 단별 흡수에서도 가장 이상적인 형태를 보여주었으며, 가장 낮은 상대표준편차를 나타내 실험대상 매립지에 가장 적합한 것으로 나타났다. 그러나 용매의 적합성은 매립지의 쓰레기 성상, 매립이력에 따라 다를 수 있다고 판단된다.