• Title/Summary/Keyword: impedance-based method

Search Result 603, Processing Time 0.027 seconds

Hybrid bolt-loosening detection in wind turbine tower structures by vibration and impedance responses

  • Nguyen, Tuan-Cuong;Huynh, Thanh-Canh;Yi, Jin-Hak;Kim, Jeong-Tae
    • Wind and Structures
    • /
    • v.24 no.4
    • /
    • pp.385-403
    • /
    • 2017
  • In recent years, the wind energy has played an increasingly important role in national energy sector of many countries. To harvest more electric power, the wind turbine (WT) tower structure becomes physically larger, which may cause more risks during long-term operation. Associated with the great development of WT projects, the number of accidents related to large-scaled WT has also been increased. Therefore, a structural health monitoring (SHM) system for WT structures is needed to ensure their safety and serviceability during operational time. The objective of this study is to develop a hybrid damage detection method for WT tower structures by measuring vibration and impedance responses. To achieve the objective, the following approaches are implemented. Firstly, a hybrid damage detection scheme which combines vibration-based and impedance-based methods is proposed as a sequential process in three stages. Secondly, a series of vibration and impedance tests are conducted on a lab-scaled model of the WT structure in which a set of bolt-loosening cases is simulated for the segmental joints. Finally, the feasibility of the proposed hybrid damage detection method is experimentally evaluated via its performance during the damage detection process in the tested model.

A Fast Computation Method of Power Ground Plane Impedance using the Mobius Transform (Mobius변환을 이용한 전력접지층 임피던스의 빠른 계산방법)

  • Suh Youngsuk;Kim In-Sung;Song Jae-Sung;Eum Tae-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.1
    • /
    • pp.41-44
    • /
    • 2005
  • A new method to reduce the computation time in power/ground-plane analysis is proposed. The existing method using the two dimensional infinite series summation take a lot of computation time. The proposed method is based on the approximation of impedance in the frequency domain through the Mobius transform. This method shows the good accuracy and the high speed in computing. In the case of impedance calculation for 9'x4' board, the proposed method takes 0.16 second of computing time whereas the existing method takes 2.2 second. This method can be applied to the analysis and design of power/ground-plane that need a lot of computation steps.

Leg Motion Monitoring using Bio-impedance Signal (생체 임피던스 신호를 이용한 하지동작 모니터링)

  • 송철규;변용훈;윤대영;김거식;임정모;전희천;권승범;이정훈;이명권
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2891-2894
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh and foot., and two potential electrodes are applied to the lateral aspect. medial aspect, and posterior position of lower leg. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least Interference, and maximum magnitude of impedance change. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level.

  • PDF

Analysis of Lower Leg Movement Using Bio-impedance Technique (바이오 임피던스를 이용한 하지 운동분석)

  • Song, C.G.;Song, C.H.;Lee, M.G.;Kim, S.C.;Kim, J.C.;Seo, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.414-417
    • /
    • 2002
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh and foot., and two potential electrodes are applied to the lateral aspect, medial aspect, and posterior position of lower leg. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level.

  • PDF

Evaluation of Errors Due to Earth Mutual Resistance in Measuring Ground Impedance of Vertically-driven Ground Electrode (수직 접지전극의 접지임피던스 측정에서 도전유도에 의한 오차 평가)

  • Choi, Jong-Hyuk;Choi, Young-Chul;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1778-1783
    • /
    • 2009
  • Ground impedance for the large grounding system is measured according to the IEEE Standard 81.2 which is based on the revised fall-of-potential method of installing auxiliary electrode at a right angle. When the auxiliary electrodes are located at an angle of $90^{\circ}$, the ground impedance inevitably includes the error due to earth mutual resistance. In this paper, in order to accurately measure the ground impedance of vertically-driven ground electrodes, error rates due to earth mutual resistance are evaluated by ground resistance and ground impedance measuring devices and compared with calculated values. As a result, the measured results are in good agreement with the computed results considering soil layer with different resistivity. The error rates due to earth mutual resistance decrease with increasing the length of ground electrode in the case that the ratio of the distance between the ground rod to be measured and the auxiliary electrodes to the length of ground electrode(D/L) is same. The ground impedance should be measured at the minimum distance between the auxiliary electrodes that will have an estimated measurement accuracy due to earth mutual resistance.

Setting Characteristic Assessment of Cementitious Materials using Electrical Impedance Spectroscopy (전기 임피던스 분광법을 이용한 시멘트계 재료의 응결 특성 평가)

  • Lee, Jun-Cheol;Park, In-Yong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.474-480
    • /
    • 2017
  • In this study, the evolution of electrical impedance of electric nodes was investigated to determine the setting time of cement paste using the electrical impedance spectroscopy method. The electric nodes were embedded in fresh cement paste and the electrical impedance signatures were continuously monitored. Vicat needle test and semi-adiabatic calorimetry test were also conducted to validate the electrical impedance spectroscopy method. During hydration period of cement paste, the magnitude of conductance gradually increased, and then started to decrease rapidly at a first certain time. After that, the magnitude of conductance gradually decreased at a second certain time. The times of turning point in the curves of magnitude of conductance seem to be related with the setting time by Vicat needle test. Also, the setting times by the electrical impedance spectroscopy method are well posed within the setting period estimated by the semi-adiabatic calorimetry test. Based on the results, it can be concluded that the setting time of cement paste can be effectively monitored through the electrical impedance spectroscopy method.

The Novel Method of Segmental Bio-Impedance Measurement Based on Multi-Frequency for a Prediction of risk Factors Life-Style Disease of Obesity (비만관련 생활습관병 위험인자 예측을 위한 다중 주파수 기반의 분할 체임피던스 측정법)

  • Kim, Eung-Seok;Noh, Yeon-Sik;Seo, Kwang-Seok;Park, Sung-Bin;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.375-384
    • /
    • 2010
  • The purpose of this study is to determine whether there is a correlation between the segmental bio-impedance measurement with the frequency modulations and the life-style disease of obesity. An obesity is not simply the factor for estimating the life-style disease of obesity, but also the risk factor occurring. There are many methods (BMI, WHR, Waist, CT, DEXA, BIA, etc.) for measuring a degree of obesity; the bio-impedance measurement is more economic and more effective than others. The physical examination, the blood test, the medical imaging diagnosis and the bio-impedancemeasurementswithmultiple frequencies for each body parts have been conducted for 77 people. The estimated value has been calculated through a segmental bio-impedance model based on multi-frequency that was created to reflect the highest correlation by analyzing correlation with linear regression analysis method for the measured bio-impedance and the risk factors. Then we compared with the clinical diagnosis. In case of high level cholesterol, low HDL-C and high LDL-C for life-style disease, the sensitivity is 80~100%and the specificity is 83~100%. This study has shown conclusively that bio-impedance can be a possible predictor to analyze the disease risk rate of population and individual health maintenance. And also the multi-frequency segmental bio-impedance can be used as early predictor to estimate the life-style disease of obesity.

Paratic Impedance Extraction of FC-PGA Package Pin using the Static Fast Multipole Method (Static FMM을 이용한 FC-PGA 패키지 핀에서의 기생 임피던스 추출)

  • 천정남;이정태;어수지;김형동
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1076-1085
    • /
    • 2001
  • In this paper, the FMM(Fast Multipole Method) combined with GMRES(Generalized Minimal RESidual Method) matrix solver is used to extract the parasitic impedance for complicated 3-D structures in uniform dielectric materials which limit the use of MoM(Method of Moment) due to its large computation time and memory requirement. This algorithm is a fast multipole-accelerated method based on quasistatic analysis and is very efficient for computing impedance between conductors. This paper proved the accuracy and efficiency of the FMM by comparing with MoM in simple examples. Finally the parasitic impedance of FC-PGA(Flip Chip Pin Grid Array) Package pins has been extracted by this algorithm and we have considered the possibility of the EMI/EMC problem caused by the signal interference.

  • PDF

Optimal Electrode Selection for Detection of Human Leg Movement Using Bio-Impedance (생체 임피던스를 이용한 인체 하지운동 출을 위한 최적 전극위치 선정)

  • 송철규;윤대영;이동헌;김승찬;김덕원
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.8
    • /
    • pp.506-509
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the changes of the lower leg electrical impedance. This impedance was measured by the four-electrode method. Two current electrodes were applied to the thigh, knee, and foot., and two potential electrodes were applied to the lateral, medial, and posterior position of human leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using a electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements were -0.913, 0.984 and 0.823, respectively. From such features of the human leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed feasibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.

Placement Standard Research of Auxiliary Probes when Measuring Ground Impedance (접지임피던스 측정시 보조전극의 배치 기준 연구)

  • Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1984-1991
    • /
    • 2011
  • Among ground impedance measurement methods, the fall-of-potential method is the most thorough and reliable method. In the fall-of-potential method, ground electrode and auxiliary probes are placed in a straight line, and then, auxiliary potential probe is moved away from the ground electrode. The point at which plotted resistance curve flattens out is taken as right position of auxiliary potential probe. However, in some cases, it is hard to place ground electrode and auxiliary probes in a straight line. Therefore, we provided alternative placement method in this research. The method can be easily applicable to placing auxiliary probes. Also, this paper analyzed and compared ground impedance measurement standards of large grounding systems. Based on the analysis, practical measurement method using an earth tester was proposed. The proposed methods presented in this paper will be useful when determining locations of auxiliary probes in alternative positions, and the methods can be applied practically and easily.