• Title/Summary/Keyword: impedance characteristics

Search Result 1,741, Processing Time 0.028 seconds

Design and Fabrication of a Wideband Ground Impedance Meter (광대역 접지임피던스 측정기의 설계 및 제작)

  • Kil, Gyung-Suk;Park, Dae-Won;Jang, Un-Yong;Han, Ju-Seop;Gil, Hyoung-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.793-797
    • /
    • 2010
  • The basic performance of the ground system is evaluated as the ground resistance by applying low frequency current below 1 kHz. However, characteristics of the ground system should be analyzed by high frequency current up to 1 MHz since transient currents having a few hundred kHz component flow during a line-to-ground fault and/or a lightning strike. This paper deals with the design and fabrication of a wideband ground impedance meter (WGIM) which measures the impedance of ground systems in ranges from 65 Hz to 1.28 MHz. Also, a noise elimination algorithm using a digital bandpass filter is proposed. The maximum error of the WGIM is 4.91% in the measurement frequency range.

Analysis of pulsed Plasma Reactor using Modelling Method (펄스플라즈마 반응기의 모델링에 의한 해석)

  • Choe, Yeong-Uk;Lee, Hong-Sik;Im, Geun-Hui;Kim, Tae-Hui;Baek, Min-Su;Jang, Gil-Hong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.30-35
    • /
    • 2000
  • The pulsed plasma wire-plate reactor was analyzed on the basis of experiment, EMTP simulation and modelling method. Though the reactor has a non-linear impedance characteristics, we demonstrate that the reactor impedance can be approximately analyzed with the measured initial capacitance and average resistive component of flat zone. Using this modelling method, the influence of the reactor capacitance on the impedance matching between pulse generator and reactor can be investigated. From this, we found that the energy of 95% was delivered form pulse generator to reactor at the ratio of $C_r/C_p\cong 0.3,\; where\; C_p\; is\; pulse\; generator\; capacitance, C_r$ is reactor capacitance.

  • PDF

Implementation of a Labview Based Time-Frequency Domain Reflectometry Real Time System for the Load Impedance Measurement (부하 임피던스 측정을 위한 랩뷰기반 시간-주파수 영역 반사파 실시간 시스템 구현)

  • Park, Tae-Geun;Kwak, Ki-Seok;Park, Jin-Bae;Yoon, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1803-1804
    • /
    • 2006
  • The purpose of this paper is to implement a Labview based TFDR Real Time system through the instruments of Pci eXtensions for Instrumentation(PXI). The proposed load impedance measurement algorithm was verified by experiments via the implemented real time system. The TFDR real time system consisted of the reference signal design, signal generation, signal acquisition, algorithm execution and results display parts. To implement real time system, all of the parts wore programmed by the Labview which is one of graphical programming languages. In the application software implemented by the Labview we were able to design a suitable reference signal according to the length and frequency attenuation characteristics of the target cable and controled the arbitrary waveform generator(ZT500PXI) of the signal generation part and the digital storage oscilloscope(ZT430PXI) of the signal acquisition part. By using the TFDR real time system with the terminal resistor on the target cable, we applied to the load impedance measurements. In the proposed load impedance algorithm a normalized time-frequency cross correlation function and a cross time-frequency distribution function was employed to calculate the reflection coefficient and phase difference between the input and the reflected signals.

  • PDF

Electrochemical Properties on High Temperature Operating Battery by Electrolyte and Salts in Electrodes (고온 작동형 전지의 전해질 및 전극내 첨가염 변화에 따른 전기화학적 특성 연구)

  • Choi, Yu-Song;Ha, Sang-Hyun;Cho, Sung-Baek
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.740-746
    • /
    • 2011
  • Thermally activated batteries have good stability, reliability and long shelf life. Due to these characteristics and operational mechanism, thermal batteries are usually applied to military power sources. Especially, Li/$FeS_2$ thermal batteries, which are used mostly in these days, use LiCl-KCl and LiBr-LiCl-LiF as electrolytes. The electrochemistry of thermal batteries have been researched for long time, however, electrochemical study using impedance spectroscopy was not published so much. Through this research, microscopic electrochemical research was investigated with electrochemical impedance spectroscopy(E.I.S). Electrolyte effects on Li/$FeS_2$ thermal battery was researched changing electrolytes, LiCl-KCl and LiBr-LiCl-LiF. Additionally, the salts, which are added to electrolytes, effects on thermal battery were researched. It is expected that the impedance spectroscopy analysis is applicable to not only thermal battery electrochemical study effectively, but also, thermal battery developments.

Magneto-impedance effect of CoFeSiBNi amorphous magnetic films (CoFeSiBNi 아몰퍼스 합금의 자기-임피던스 효과)

  • Lee, Seung-Hun;Park, Byung-Kyu;Hwang, Sung-Woo;Moon, Sung
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.389-393
    • /
    • 2007
  • Soft ferromagnetic materials are very useful for many sensors using magnetic materials demanding high permeability, low coercivity and low hysteresis loss. Among them, FeCoSiBNi amorphous magnetic films show a good impedance change (about 5.01 %/Oe, at 10 MHz) by the exterinal magnetic field in this experiment. The magnetic films are produced by melt-spun method, one of the rapid solidification process. Ribbon shape wires were made from the films, and let them annealed in DC magnetic field to increase the maximum Giant Magneto Impedance ratio. Field annealing decreases the stress and changes the effective anisotropy. Thus, we can find that the impedance change (200.47 %) is improved and the fabricated magnetic wire has characteristics of good sensor element.

THE TRANSFER OF CHLORIDE ION ACROSS ANION EXCHANGE MEMBRANE

  • Yu, Zemu;Wang, Hanming;Wang, Erkang
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.597-601
    • /
    • 1995
  • The transfer of chloride ion across an anion exchange membrane (AEM) was investigated by cyclic voltammetry (CV) and electrochemical impedance spectra. In CV experiment, when the size of the hole in membrane was much smaller than the distance between membrane holes, the Cl anion transfer showed steady state voltammetric behavior. Each hole in membrane can be regarded as a microelectrode and the membrane was equivalent to a microelectrode array in this condition. When the hole in membrane was large or the distance between membrane holes was small, the CV curve of the Cl anion transfer across membrane showed peak shape, which attributed to linear diffusion. In ac impedance measurement, the impedance spectrum of the membrane system was composed of two semicircles at low de bias, corresponding to the bulk characteristics of the membrane and the kinetic process of ion transfer, respectively. The bulk membrane resistance increases with increasing dc bias and only one semicircle was observed at higher dc bias. The parameters related to kinetic and membrane properties were discussed.

  • PDF

High Selectivity Coupled Line Impedance Transformer with Second Harmonic Suppression

  • Kim, Phirun;Park, Junsik;Jeong, Junhyung;Jeong, Seungho;Chaudhary, Girdhari;Jeong, Yongchae
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.1
    • /
    • pp.13-18
    • /
    • 2016
  • This paper presents a design of an impedance transformer (IT) with high frequency selectivity characteristics. The frequency selectivity can be controlled by even- and odd-mode impedance of a shunt coupled transmission line (TL). For experimental validation, a 50- to $20-{\Omega}$ IT was implemented at a center frequency ($f_0$) of 2.6 GHz for the long-term evolution signal. The measured results were in good agreement with the simulations, showing a return loss higher than 19 dB over a passband bandwidth of 0.63 GHz (2.28-2.91 GHz) and good sharp frequency selectivity characteristic near to the passband. The series coupled TL provides a transmission zero at 5.75 GHz, whereas the shunt coupled TL provides three transmission zeros located at 2 GHz, 3.1 GHz, and 7.14 GHz.

Effects of Auxiliary Probe on Low Frequency Ground Impedance Measurement (저주파 접지임피던스 측정에 미치는 보조전극의 영향)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon;Moon, Hyun-Wook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.367-370
    • /
    • 2008
  • In this paper, the effects of the position and the angle of the auxiliary probes on the measurements of the low frequency ground impedance with the fall-of-potential method are described iud the testing techniques to minimize the measuring errors are proposed. The fall-of-pot ential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the characteristics of ground impedance due to the location of the potential probe, ground impedances were measured in case that the distance of current probe was fixed at 50[m] and the distance of potential probe was located from 10[m] to 50[m]. Also, the potential robe was located at 30[$^{\circ}$], 40[$^{\circ}$], 60[$^{\circ}$], 90[$^{\circ}$], and 180[$^{\circ}$]. The results could be help to determine the location of potential probe when the ground impedance was measured at grounding system.

  • PDF

Impedance Estimation for Lithium Secondary Battery According to 1D Thermal Modeling (리튬 2차 전지의 1차원 열적 특성을 고려한 임피던스예측)

  • Lee, Jung-Su;Lim, Geun-Wook;Kim, Kwang-Sun;Cho, Hyun-Chan;Yoo, Sang-Gil
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.2
    • /
    • pp.13-17
    • /
    • 2008
  • In this paper, in order to get the characteristics of the lithium secondary cell, such as charge and discharge characteristic, temperature characteristic, self-discharge characteristic and the capacity recovery rate etc, we build a thermal model that estimate the impedance of battery by experiment & simulation. In this one-dimensional model, Seven governing equations are made to solve seven variables c, $c_s,\;\Phi_1,\;\Phi_2,\;i_2$, j and T. The thermal model parameters used in this model have been adjusted according to the experimental data measured in the laboratory. The result(Voc, Impedance) of this research can be used in BMS(Battery Management System), so an efficient method of using battery is developed.

  • PDF

Impedance Characterization of Tantalum Oxide Deposited through Pulsed-Laser Deposition

  • Kwon, Kyeong-Woo;Jung, Jin-Kwan;Park, Chan-Rok;Kim, Jin-Sang;Baek, Seung-Hyub;Hwang, Jin-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.207.1-207.1
    • /
    • 2013
  • Tantalum oxide has been extensively investigated as one of the promising Resistive switching materials applicable to Resistive Dynamic Access Memories. Impedance spectroscopy offers simultaneous measurements of electrical and dielectric information, separation of electrical origins among bulk, grain boundaries, and interfaces, and the monitoring of electrical components. Such benefits have been combined with the resistive states of resistive switching devices which can be described in terms of equivalent circuits involving resistors, capacitors, and inductors, The current work employed pulsed laser deposition in order to prepare the oxygen-deficient tantalum oxide. The fabricated devices were controlled between highresistance and low-resistance states in controlled current compliance modes. The corresponding electrical phenomena were monitored both in the dc-based current-voltage characteristics and in the ac-based impedance spectroscopy. The origins of the electrical switching are discussed towards optimized ReRAM devices in terms of interfacial effects.

  • PDF