• Title/Summary/Keyword: impedance characteristics

Search Result 1,741, Processing Time 0.025 seconds

Analysis of the Unbalance of DC Link Voltage in 12-step Inverter with 2-Phase Chopper Preregulator (2상 쵸퍼 Preregulator를 갖는 12-step 인버터에서의 DC Link단 전압 불평형 해석)

  • Nho, Eui-Cheol;Kim, In-Dong
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.258-260
    • /
    • 1995
  • This paper deals with the voltage unbalance of DC link voltage in series connected two 6-step inverters with double chopper preregulator. Each output of the 6-step inverter is connected to each transformer. The secondary windings of one of the transformers is zig-zag connected and the other star connected. The secondary terminals of the two transformers are series connected which makes 12-step output voltage waveform. In this case, the characteristics of the two transformers are rather different each other. The difference results in the voltage unbalance of the two 6-step inverter input capacitor voltages which make the DC link voltage. The degree of the voltage unbalance is analysied with the variations of load power, load power factor and % impedance of the transformer.

  • PDF

A Design of Lateral Power MOS with Improved Blocking Characteristics (향상된 항복특성을 위한 수평형 파워 MOS의 설계)

  • Kim, Dae-Jong;Sung, Man-Young;Kang, Ey-Goo
    • 한국컴퓨터산업교육학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.95-98
    • /
    • 2003
  • Power semiconductors are being currently used as a application of intelligent power inverters to a refrigerator, a washing machine and a vacuum cleaner as well as core parts of industrial system. The rating of semiconductor devices is an important factor in decision on the field of application and the forward blocking voltage is one of factors in decision of the rating. The Power MOS device has a merit of high input impedance, short switching time, and stability in temperature as well known. Power MOS devices are mainly used as switches in the field of power electronics, especially the on-state resistance and breakdown voltage are regarded as the most important parameters. Power MOS devices that enable a small size, a light weight, high-integration and relatively high voltage are required these days. In this paper, we proposed the new lateral power MOS which has forward blocking voltage of 250V and contains trench electrodes and verified manufactural possibility by using TSUPREM-4 that is process simulator.

  • PDF

Compact Microstrip-Fed Square Loop Antenna for DTV Applications

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.4
    • /
    • pp.222-226
    • /
    • 2016
  • A design method for a compact square loop antenna fed by a microstrip (MS) line for indoor digital television (DTV) applications is proposed. The proposed antenna consists of a square loop, circular sectors, and an MS line. The square loop combined with circular sectors is printed on one side of a substrate, and a $75-{\Omega}$ MS line is printed on the other side. The circular sectors are used as a wideband balun or transition to connect the MS line and the square loop. A prototype of the proposed square loop antenna operating in the DTV band (470-806 MHz) is designed and fabricated on an FR4 substrate. Experimental results show that the proposed antenna has the desired impedance characteristics in the frequency band of 464-1,220 MHz (89.8%) for a voltage standing wave ratio (VSWR) of <2 covering the DTV band, and a broadside gain of 0.8-3.3 dBi in the DTV band.

A Study Of Parallel Characteristics Of 50[W] Virtual Implement of 50[W]Solar Cell modules Using Droop-Method (Droop Method를 이용한 50[W]급 태양전지 가상구현 시스템의 병렬연결 출력특성에 대한 연구)

  • Lee B.I.;Lee S.Y.;Oh B.W.;Jung B.H.;Choe G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.692-695
    • /
    • 2003
  • Generally, photovoltaic system is composed with several solar cell modules. For increasing power of photovoltaic systems, serial and parallel connection needed. A Desirable characteristic of a parallel supply system is that individual converters share the load current equally and stably. The current sharing(CS) can be implemented using two approaches. The first one, known as a droop method, relies on the high output impedance of each converter. and The second approach, known as active current-sharing techniques. In this paper, using droop method at parallel connection with it's convenience and simplicity.

  • PDF

결합된 자기공명을 통한 무선에너지 전력 전송 시스템의 회로 해석

  • Jeon, Sang-Hun;Kim, Yong-Hae;Lee, Myeong-Rae;Gang, Seung-Yeol
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.405-407
    • /
    • 2010
  • Simple equivalent circuit model is developed for wireless energy transfer system via coupled magnetic resonances and practical design method is also provided. Node equations for the resonance system are built with the method expanding transformer's equations and the optimum distances of coils in the system is derived analytically for optimum coupling coefficients for high transfer efficiency. Moreover, to calculate the frequency characteristics for a lossy system the equivalent model is established at an electric design automation tool. The model parameters of the actual system are extracted and the results of modeling are compared with the measurement. Through the developed model, we can understand the principles that the system shows higher efficiency than conventional magnetic coupling systems and impedance matching is important to achieve high efficiency.

  • PDF

An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram (과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘)

  • 허정용;김철환
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.161-167
    • /
    • 2004
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk lot mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel Zone 3 scheme based on combining the steady-state components (i.e. 60Hz) and the transient components (TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

Design control algorithm for arc current (아크전류 제어 알고리즘 설계)

  • Ban, Gi-Jong;Han, Hong-Kyun;Nam, Moon-Hyon;Kim, Lark-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.387-390
    • /
    • 2002
  • In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the low voltage and low current network. Arc in electrical network have the characteristics of low current, high impedance and high frequency. Conventional controller does not have the arc current interrupt function. Hence, In this paper, arc current control algorithm is designed for the interruption of arc fault current.

  • PDF

A study on operating properties of superconducting fault current limiter in the line-to-line fault (선간 단락사고에 대한 초전도 한류기의 동작특성에 대한 연구)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.86-88
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with $100{\Omega}$ of quench impedance for a line-to-line fault in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 13 kA, but with $2{\sim}3\;kA$ of DC component which decreased to zero in 6 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

A Study on the Improvement of Volumetric Efficiency by the Resonators for the 4-Cylinder SI Engines. (공명기를 이용한 4기통 SI기관의 체적효율 향상에 관한 연구)

  • 이재순;이성두;윤건식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.232-242
    • /
    • 1996
  • In this study, the simulation program for the prediction of volumetric efficiency of the internal combustion engine by the resonator has been developed, when the resonator is mounted on the intake system of 4-cycle SI engines for the improvement of volumetric efficiency. The experimental work has also been carried out for the verification of the program, and it is found that the result of calculation by the simulation program fits qualitatively well with that of experiment. To get the optimal mounting position of resonator on the intake system, the influence of the variation of dimensions of resonator such as neck length, volume and neck diameter were examined by the numerical calculation of the program in advance and the results were compared with the experiments. It is found that the position which is departed 150cm from plenum chamber is better than any other positions, and the average amount of the increase of volumetric efficiency is about 2∼3%

  • PDF

A Study on the Characteristics of Wide Band Matching Connector in Round Coaxial Lines (원형 동축 선로에서 광대역 매칭 커넥터의 특성 연구)

  • Kim, Byeong-Woo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.152-157
    • /
    • 2012
  • In this paper, smoothing plane connector have been proposed as the vehicle connector for the wireless access in vehicular environments (5.925GHz) communication. This smoothing plane connector is designed by considering the properties of critical parameter like smoothing distance of start to end point of contact area. The design simulation and results can be used to determine the most suitable smoothing plane wire dimensions for vehicle communication connector. The optimized WAVE connector inserted the smoothing plane wire has insertion loss less than-0.17dB at 5.925GHz. It provides 20% of insertion loss with good performance. Therefore, the simulated results can be effectively used for optimum design of high frequency connector for vehicle communication.