• 제목/요약/키워드: impact-location

검색결과 842건 처리시간 0.028초

수리 모형을 이용한 Korea Land Data Assimilation System (KLDAS) 자료의 수문자료에 대한 영향력 분석 (Interactions between Soil Moisture and Weather Prediction in Rainfall-Runoff Application : Korea Land Data Assimilation System(KLDAS))

  • 정용;최민하
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2011년도 정기 학술발표대회
    • /
    • pp.172-172
    • /
    • 2011
  • The interaction between land surface and atmosphere is essentially affected by hydrometeorological variables including soil moisture. Accurate estimation of soil moisture at spatial and temporal scales is crucial to better understand its roles to the weather systems. The KLDAS(Korea Land Data Assimilation System) is a regional, specifically Korea peninsula land surface information systems. As other prior land data assimilation systems, this can provide initial soil field information which can be used in atmospheric simulations. For this study, as an enabling high-resolution tool, weather research and forecasting(WRF-ARW) model is applied to produce precipitation data using GFS(Global Forecast System) with GFS embedded and KLDAS soil moisture information as initialization data. WRF-ARW generates precipitation data for a specific region using different parameters in physics options. The produced precipitation data will be employed for simulations of Hydrological Models such as HEC(Hydrologic Engineering Center) - HMS(Hydrologic Modeling System) as predefined input data for selected regional water responses. The purpose of this study is to show the impact of a hydrometeorological variable such as soil moisture in KLDAS on hydrological consequences in Korea peninsula. The study region, Chongmi River Basin, is located in the center of Korea Peninsular. This has 60.8Km river length and 17.01% slope. This region mostly consists of farming field however the chosen study area placed in mountainous area. The length of river basin perimeter is 185Km and the average width of river is 9.53 meter with 676 meter highest elevation in this region. We have four different observation locations : Sulsung, Taepyung, Samjook, and Sangkeug observatoriesn, This watershed is selected as a tentative research location and continuously studied for getting hydrological effects from land surface information. Simulations for a real regional storm case(June 17~ June 25, 2006) are executed. WRF-ARW for this case study used WSM6 as a micro physics, Kain-Fritcsch Scheme for cumulus scheme, and YSU scheme for planetary boundary layer. The results of WRF simulations generate excellent precipitation data in terms of peak precipitation and date, and the pattern of daily precipitation for four locations. For Sankeug observatory, WRF overestimated precipitation approximately 100 mm/day on July 17, 2006. Taepyung and Samjook display that WRF produced either with KLDAS or with GFS embedded initial soil moisture data higher precipitation amounts compared to observation. Results and discussions in detail on accuracy of prediction using formerly mentioned manners are going to be presented in 2011 Annual Conference of the Korean Society of Hazard Mitigation.

  • PDF

핵종 이온 광물화 처리기술의 APR 1400 발전소 액체방사성폐기물관리계통 적용 위치에 대한 고찰 (A Study on the Application of Ion Crystallization Technology to the APR 1400 Liquid Waste Management System)

  • 고경민;김창락
    • 방사성폐기물학회지
    • /
    • 제17권4호
    • /
    • pp.419-427
    • /
    • 2019
  • APR 1400 액체방사성폐기물관리계통 효율성 증가와 계통의 성능 개선을 위한 방안으로 핵종 이온 광물화 처리기술을 적용하는 것을 고려하였다. 핵종 이온 광물화 처리기술은 현재까지 발전소에 실제적으로 적용되진 않았지만 원자력발전소의 액체방사성폐기물에 존재하는 다양한 핵종 이온을 최소 95% 이상 선택적으로 제거 가능 하다는 것을 실험적으로 증명한 바 있다. 본 논문은 핵종 이온 광물화 처리기술의 제염율을 반영하여 기존 설계에 적용 가능성을 확인하였으며, 기존 설계를 개선할 수 있는 방안을 마련하였다. 핵종 이온 광물화 처리기술의 제염 특성과 기존의 액체방사성폐기물관리계통 설계 및 운전 경험을 고려하여 최적의 적용 위치를 결정하였다. 원자력발전 운영에 따라 발생하는 액체방사성물질이 수집되는 수집탱크에 핵종 이온 광물화 처리기술을 적용하는 것이 기존 설계의 영향이 가장 적을 것이며, 개선 효과도 가장 큰 것으로 해석되었다. 핵종 이온 광물화 처리기술이 현재의 APR 1400 발전소 또는 신규 원전에 적용될 경우 액체방사성폐기물관리계통의 운전 효율성 증가와 계통의 성능 개선이 기대된다.

서울시 지하철 시스템 내의 입자상물질(PM10, PM2.5) 농도 특성 (Concentration and Properties of Particulate Matters (PM10 and PM2.5) in the Seoul Metropolitan)

  • 이태정;임효지;김신도;박덕신;김동술
    • 한국대기환경학회지
    • /
    • 제31권2호
    • /
    • pp.164-172
    • /
    • 2015
  • Seoul subway plays an important part for the public transportation service in Seoul metropolitan area. As the subway system is typically a closed environment, frequent air pollution problems occurred and passengers get malhealth impact. Especially particulate matters (PM) is well known as one of the major pollutants in subway environments. The purpose of this study was to compare the concentrations of $PM_{10}$ and $PM_{2.5}$ in the Seoul subway system and to provide fundamental data in order to management of subway system. $PM_{10}$ and $PM_{2.5}$ samples were collected in the M station platform and tunnel of Subway Line 4 in Seoul metropolitan and in an outdoor location close to it from Apr. 21, 2010~Oct. 27, 2013. The samples collected on teflon filters using $PM_{10}$ and $PM_{2.5}$ mini-volume portable samplers and PM sequential sampler. The PM contributions were $48.6{\mu}g/m^3$ (outdoor), $84.6{\mu}g/m^3$ (platform) and $204.8{\mu}g/m^3$ (tunnel) for $PM_{10}$, and $34.6{\mu}g/m^3$ (outdoor), $49.7{\mu}g/m^3$ (platform) and $83.1{\mu}g/m^3$ (tunnel) for $PM_{2.5}$. The $PM_{10}$ levels inside stations and outdoors are poorly correlated, indicating that $PM_{10}$ levels in the metro system are mainly influenced by internal sources. In this study, we compared PM concentrations before and after operation of ventilation and Electrostatic Precipitator (EP). Despite the increased PM concentration at outdoor, $PM_{10}$ concentration at platform and tunnel showed the 31.2% and 32.3% reduction efficiency after operation the reduction system. The overall results of this study suggest that the installation and operation of the ventilating system and EP should have served as one of the important components for maintaining the air quality in the subway system.

해수면 상승으로 인한 지하수 해수침투 및 토양 염류화 합성 평가모델 (Composite model for seawater intrusion in groundwater and soil salinization due to sea level rise)

  • 정은태;박남식;조광우
    • 한국수자원학회논문집
    • /
    • 제50권6호
    • /
    • pp.387-395
    • /
    • 2017
  • 기후변화에 따른 해수면 상승으로 인하여 해안지역의 지하수계에 해수침투가 가중된다. 지하수의 염분농도가 증가하면 지하수면 상부의 불포화 토양에서도 염분 농도가 증가할 수 있으며, 이는 농경지에서 작물피해를 일으킬 수 있다. 해수면이 상승함에 따라 내륙의 지하수위도 함께 상승한다. 이는 불포화 토양층의 두께를 감소시켜 해안 저지대의 경작에 피해를 끼칠 수 있다. 본 연구에서 지하수 해수침투는 3차원 모델, 토양 염류화 평가는 연직 1차원 모델을 합성 적용하여 해안 농경지에 대한 해수면 상승 피해를 평가하는 방법을 개발하였다. 3차원 해수침투 모델에서 지하수면의 수위와 농도분포를 계산하고 최상부 절점 중에서 염분 농도가 기준 값 이상인 절점에서 지하수면과 지표면 사이의 토양층에서 연직 1차원 모델링으로 토양층의 염분 농도와 불포화대 두께를 계산하였다. 농경지의 토양 염류화는 작물의 뿌리 심도에서 보통 작물의 생육한계 염분농도를 기준으로 판단하였다. 개발된 모델링 방법을 가상의 간척농경지에 적용하였다. 해수면 상승자료로 IPCC의 RCP 4.5와 8.5 시나리오를 사용하였다. 평가 결과는 2050년과 2100년에 대하여 제시하였다. 연구결과 대상지역에서 기후변화 시나리오 RCP 8.5에서 2100년에는 지하수 염류화 피해 면적은 간척지 육지면적 대비 7.8%, 염류화 토양 면적은 6.0%, 불포화층의 두께가 뿌리심도보다 적은 지역의 면적은 1.6% 증가하는 것으로 분석되었다.

거제도 천장산 일대 상록활엽수림의 식물군집구조 특성 (Plant Community Structure Characteristic of the Evergreen Forest, Cheonjangsan(Mt.) at GeoJae)

  • 이광규;이수동;김지석;조봉교
    • 한국환경생태학회지
    • /
    • 제33권6호
    • /
    • pp.708-721
    • /
    • 2019
  • 본 연구는 거제도에 분포하는 난대림대의 식물군집구조 특성을 파악하기 위하여, 교목층, 아교목층, 관목층에 상록활엽수가 우점하거나 분포하는 천장산 북동사면을 대상으로 조사구를 설정하였다. 조사구는 상록활엽수가 분포하는 능선, 계곡, 경사지 등 천장산을 대표할 수 있는 식생군락과 입지환경의 변화가 있는 지역을 대상으로 31개소의 방형구를 설치하였다. TWINSPAN에 의한 군락분류 결과, 참식나무-굴피나무, 참식나무-때죽나무, 참식나무-참회나무, 곰솔-참식나무, 참식나무-졸참나무, 굴참나무-굴피나무 6개 군락으로 구분되었다. 난대림의 천이경향에 의하면, 곰솔, 낙엽활엽수를 거쳐 상록활엽수로 진행된다라는 연구결과를 반영한다면, 곰솔군락 뿐만 아니라 졸참나무, 굴피나무, 굴참나무 등 낙엽활엽수가 우점하거나 경쟁하는 지역도 참식나무가 우점하는 상록활엽수로 천이가 진행될 것이다. 환경요인과 식생분포간의 관계를 살펴보면, 경사도, Na+, K+, 전기전도도, 물리적 특성 중 점토(clay) 등이 식생분포에 직간접적인 영향을 미치는 것으로 분석되었다.

우리나라 병원의 경영전략 실태 (Management Strategy of Hospitals in Korea)

  • 문옥륜;이기효
    • 한국병원경영학회지
    • /
    • 제1권1호
    • /
    • pp.108-135
    • /
    • 1996
  • This paper investigates the current feature of management strategy of hospitals in Korea, and examines the relationships between adoption of a particular strategic orientation and the hospitals environmental and organizational characteristics, strategic behaviors and management improvement activities, and financial performance. Data were collected from CEOs of 88 hospitals among 650 hospitals for a 13.5% response rate using the self-administered questionnaire by mail survey. The major findings that obtained are as follows: 1. Only 37.2% of response hospitals carried out strategic planning, Most of these hospitals established the first strategic planning in 1991(81.3%) and renovated strategic planning by 4 or 5 years(56.3%), and modified strategic planning with flexibility(59.4%). Most strategic plans were documented, but informalized(68.8%). And only 29.0% of these hospitals had independent planning division. 2. Hospital services that CEOs assessed rank ordered for their impact on profitability are as follows: i)diagnostic ultrasound facility, computerized tomography scanner, obstetric inpatient unit, therapeutic X-ray, and physical therapy at present. ii)diagnostic ultrasound facility, physical therapy, computerized tomography scanner, emergency department, and health screening at future. And the services rank ordered that CEOs hoped to introduce are as follows: emergency department, physical therapy, health screening, volunteer services, and computerized tomography scanner. 3. Using a typology developed by Miles and Snow(l978), the strategic orientation of response hospitals are shifting significantly from defenders in the past to analyzers in the present, and to prospectors in the future(p<.01). 4. With regard to hospital environmental and organizational characteristics such as ownership, physician training, location, bed size, and hospital management training career and specialty of CEOs, the four strategic orientation archetypes varied not significantly. But, hospitals with a analyser orientation in the present and a reactor orientation in the future perceived competition significantly higher than the other three archetypes(p<.05). 5. The four archetypes rank ordered in terms of appling strategic behaviors and management improvement activities are as follows: prospector, analyzer, reactor, and defender. 6. The four archetypes differed significantly in terms of their financial performance using revenue per bed(p<.05). Reactors and prospectors in terms of total revenue per bed, prospectors in terms of outpatient revenue per bed, and reactors and prospectors in terms of inpatient revenue per bed had the best performance.

  • PDF

택지개발사업의 환경친화적 대안평가모형 구축 (Alternative Evaluation Model in the Development of Environment-friendly Residential Land)

  • 정인수;이찬식
    • 한국건설관리학회논문집
    • /
    • 제10권1호
    • /
    • pp.156-166
    • /
    • 2009
  • 최근 들어 택지개발사업이 크게 증가하는 추세이지만, 무분별한 택지개발은 개발대상 부지의 기존 녹지나 수목을 훼손시키게 되며 지형에도 많은 변화를 가져와 절개지가 발생하게 하는 등 환경을 많이 훼손하고 있다. 택지개발 등 개발사업을 시행할 때 지구지정시 수행하는 사전환경성검토제도와 개발계획의 승인전 협의를 하게 되어 있는 환경영향평가제도가 있다. 사전환경성검토는 택지개발계획 수립 후에 시행하며 환경영향평가는 실시설계 완료 후에 수행하기 때문에 선정된 택지개발지에서 발생할 수 있는 환경문제에 대한 저감방안 강구 등 소극적이고 수동적인 대처에 그치는 경우가 많다. 본 논문의 목적은 초기 입지선정단계에서 택지개발사업을 환경친화적으로 지속가능하게 수행할 수 있도록 대안평가모형을 구축하는 것이다. 이를 위해 선행연구에서 조사된 택지개발사업의 환경평가요인을 바탕으로 퍼지추론과 AHP기법을 이용하여 대안평가 모형을 구축하였다. 의사결정자가 각 대안의 환경훼손도를 10점 척도법에 의해 평가하면 퍼지추론에 의해 환경성능(EP: Environmental Performance)으로 변환하고, AHP기법에 의해 미리 산정된 항목별 가중치를 적용하여 통합환경성능(TEP: Total Environmental Performance)을 산정한다. 통합환경성능이 가장 높은 대안이 최적안으로 선택된다. 이 연구에서 제시한 평가방법을 적용하면 토지이용계획이 확정되지 않은 상태에서 두 가지 이상의 택지개발 예정지역 대안을 정량적으로 평가할 수 있을 것이다. 이로써 택지개발 사업시행으로 발생할 수 있는 환경훼손을 초기 입지단계에서 확인하여 환경오염을 원천적으로 제거해 나갈 수 있을 것이다.

복합영상관의 성능위주설계를 위한 가연물의 연소발열특성 연구: 객석의자의 열발생률 및 연소확산속도를 중심으로 (A Study on the Heat Release Characteristics of Fire Load for Performance Based Design of Multiplexes: A Focus on the Heat Release Rate and Fire Spread Rate of Cinema Seats)

  • 남동군;장효연;황철홍;임옥근
    • 한국화재소방학회논문지
    • /
    • 제34권1호
    • /
    • pp.11-17
    • /
    • 2020
  • 성능위주설계의 설계화원 정보는 피난안전성 평가에 직접적인 영향을 미치기 때문에, 실물화재 실험에 근거한 설계화원의 설정이 매우 중요하다. 복합영상관에 대한 성능위주설계의 신뢰성을 개선시키기 위하여, 상영관 의자에 대한 화재실험을 통해 열발생률과 화재확산속도 등의 화재거동에 관한 정보를 제공한다. 이를 위하여 실제 상영관과 유사하게 배열된 다수의 객석 의자가 적용되었다. 주요 결과로서, 객석의자 1개에 대하여 최대 열발생률과 단위 질량당 발열량은 각각 415~988 kW와 15.2~23.8 MJ/kg의 범위를 갖는다. 신형과 구형 객석의자의 평균 단위 질량당 발열량은 각각 23.6 MJ/kg과 16.7 MJ/kg으로 측정되었다. 즉, 신형의자의 증가된 플라스틱 및 쿠션재의 함량으로 인하여, 신형이 구형에 비해 화재위험성이 높은 것으로 확인되었다. 추가로 객석의자가 일렬로 배치될 때, 점화위치와 상관없이 0.39~0.42 m/min의 화재확산속도가 관찰되었다. 마지막으로 복합영상관의 성능위주설계를 위하여 객석의자의 최대 열발생률과 화재성장률로 구성된 화재성장곡선이 제안되었다.

Screening Colonoscopy from a Large Single Center of Thailand - Something Needs to be Changed?

  • Aswakul, Pitulak;Prachayakul, Varayu;Lohsiriwat, Varut;Bunyaarunnate, Thirapol;Kachintorn, Udom
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권4호
    • /
    • pp.1361-1364
    • /
    • 2012
  • Background: Results of screening colonoscopy from Western countries reported adenoma detection rates (ADRs) of 30-40% while those from Asia had ADR as low as 10%. There have been limited data regarding screening colonoscopy in Thailand. The objectives of this study were therefore to determine polyp and adenoma detection rates in Thai people, to evaluate the incidence of colorectal cancer detected during screening colonoscopy and to determine the endoscopic findings of the polyps which might have some impact on endoscopists to perform polypectomy. Materials & Methods: This study was a retrospective electronic chart review of asymptomatic Thai adults who underwent screening colonoscopy in our endoscopic center from June 2007 to October 2010.Results: A total of 1,594 cases were reviewed. The patients had an average age of $58.3{\pm}10.5$ years (range 27-82) and 55.5% were female. Most of the cases (83.8%) were handled by staff who were endoscopists. A total of 488 patients (30.6%) were reported to have colonic polyps. Left-sided colon was the most common site (45.1%), followed by right-sided colon (36.5%) and the rectum (18%). Those polyps were removed in 97.5% of cases and 88.5 % of the polyps were sent for histopathology (data lost 11.5%). Two hundred and sixty three cases had adenomatous polyps, accounting for 16.5 % ADR. Advanced adenomas were detected in 43 cases (2.6%). Hyperplastic polyps were mainly located distal to the splenic flexure of the colon whereas adenomas were found throughout the large intestine. Ten cases (0.6%) were found to have colorectal cancer. Four advanced adenomas and two malignant polyps were reported in lesions ${\leq}$ 5 mm. Conclusion: The polyp detection rate, adenoma detection rate, advanced adenoma detection rate and colorectal cancer detection rate in the screening colonoscopy of Thai adults were 30.9%, 16.5%, 2.6% and 0.6% respectively. Malignant transformation was detected regardless of the size and location of the polyps. Therefore, new technology would play an important role indistinguishing polyps.

회계학 관련 학술지의 인용지수 비교 및 상호인용 빈도를 이용한 네트워크 분석 (Network analysis using frequency of cross-citation and comparing citation index of accounting journals)

  • 최경호;오희화;곽희종
    • 디지털융복합연구
    • /
    • 제12권2호
    • /
    • pp.143-149
    • /
    • 2014
  • 현재 국내학술지의 경우 급격한 양적 성장에도 불구하고 학술지의 내용과 질적 수준을 평가할 수 있는 객관적이고 계량적인 기준이 미비한 상태이며, 국내 연구 성과 측정 시 SCI 등 해외인용지수에 의존함으로써 우수논문의 해외 유출 및 우리말 논문 등한 시 등의 문제가 발생하고 있다. 이에 한국학술지인용색인(KCI)에서는 국내 학술단체가 발간하는 학술지를 대상으로 학술지 정보, 게재논문 정보 및 참고문헌을 DB화하여 논문 간 인용관계분석 등을 실시하고, KCI 홈페이지를 통해 논문 및 학술지의 기본정보 및 각종 인용지수 등을 공개하고 있다. 본 연구는 회계학 관련 국내 학술지들이 어떠한 수준의 영향력을 가지고 있는지를 다양한 KCI 인용지수를 이용하여 비교해보고, 상호인용 빈도를 활용하여 학술지 간 연결망을 사회네트워크분석 관점에서 조망해 보았다. 그 결과 회계학 관련 학술지들이 지금보다 더욱 발전적인 위치를 갖기 위해서는 다양한 학제적 연구를 관련 학회차원에서 장려할 필요가 있으며, 이를 통하여 타 학문분야와 활발하게 교류가 이루어진다면, 이는 분명 회계학 관련 학술지의 위상이 크게 강화될 것으로 기대해 본다.