• Title/Summary/Keyword: impact loads

Search Result 723, Processing Time 0.035 seconds

Concept and Indicators of Eco-Efficient Water Infrastructure for Asia and the Pacific

  • Lee, Seung-Ho;Kang, Boo-Sik;Hong, Il-Pyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.2169-2175
    • /
    • 2009
  • This research aims to evaluate the concept of eco-efficient water infrastructure and provides a list of case studies in order to help understand the applicability of eco-efficient water infrastructure to Asia and the Pacific. A set of indicators have been explored to assess eco-efficiency in water infrastructure for the region on a micro and macro scale. The core idea of eco-efficiency, 'more value with less impact (on the environment)', has proven to be applicable in management of water infrastructure. The fundamental elements in eco-efficient water infrastructure should encompass physical infrastructure and non-physical infrastructure, which is more needed particularly in Asian countries. The case studies have demonstrated the applicability of the concept of eco-efficient water infrastructure. The Republic of Korea has provided the case of the eco-friendly approaches to enhance dam management and its innovative solutions how to use water more efficiently through state-of-art technologies. The experiences of Singapore are some of the best evidence to establish eco-efficient water infrastructure, for instance, the NEWater project via application of cutting edge technologies (recycled water) and institutional reform in water tariff systems to conserve water as well as enhance water quality. A list of indicators to assess eco-efficiency in water infrastructure have been discussed, and the research presents a myriad of project cases which are good to represent eco-efficiency in water infrastructure, including multipurpose small dams, customized flood defense systems, eco-efficient ground water use, and eco-efficient desalination plants. The study has presented numerous indicators in five different categories: 1) the status of water availability and infrastructure; 2) production and consumption patterns of freshwater; 3) agricultural products and sources of environmental loads; 4) damages from water-caused natural disaster; and 5) urban water supply and sanitation. There are challenges as well as benefits in such indicators, since the indicators should be applied very carefully in accordance with specific socio-economic, political and policy contexts in different countries in Asia and the Pacific Region. The key to success of establishment of eco-efficient water infrastructure in Asia primarily depends on the extent to which each country is committed to balancing its development of physical as well as non-physical water infrastructure. Particularly, it is imperative for Asian countries to transform its policy focus from physical infrastructure to non-physical infrastructure. Such shift will help lead to implementation of sustainable in Asian countries.

  • PDF

Optimization of tunnel support patterns using DEA (차분진화 알고리즘을 적용한 터널 지보패턴 최적화)

  • Kang, Kyung-Nam;An, Joon-Sang;Kim, Byung-Chan;Song, Ki-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.211-224
    • /
    • 2018
  • It is important to design tunnel support system considering the various loads acting on the tunnel because they have a direct impact on the stability of tunnels. In Korea, standardized support patterns are defined based on the rock mass classification system depending on the project, and it is stated that it should be modified appropriately considering the behavior of tunnel during construction. In this study, the tunnel support pattern optimization method is suggested based on the convergence-confinement method, earth pressure, axial force of rock bolt, and moment acting on the shotcrete. The length and spacing of the rock bolts and the thickness of the shotcrete were optimized by using the differential evolution algorithm (DEA) and the results were compared to the standard support pattern III for railway tunnel. Rock bolt length can be reduced and the installation interval can be widened for shallow tunnel. As the depth of tunnel increases, the thickness of shotcrete increases linearly. Therefore, the thickness of shotcrete should be thicker than the standard support pattern as the depth of tunnel increases to secure the stability of tunnel.

Effects of Loading on Biomechanical Analysis of Lower Extremity Muscle and Approximate Entropy during Continuous Stair Walking (지속적인 계단 보행에서 부하가 하지 근육의 생체역학적 변인과 근사 엔트로피에 미치는 영향)

  • Kim, Sung-Min;Kim, Hye-Ree;Ozkaya, Gizem;Shin, Sung-Hoon;Kong, Se-Jin;Kim, Eon-Ho;Lee, Ki-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.323-333
    • /
    • 2015
  • Objective : The purpose of this study was to investigate the changes of gait patterns and muscle activations with increased loads during stair walking. Also, it can be used as descriptive data about continuous stair walking in a real life setting. Method : Twelve sedentary young male adults(Age: $27.0{\pm}1.8yrs$, Weight: $65.8{\pm}9.9kg$) without any lower extremity injuries participated in this study. Participants performed stair walking up 7 floors and their ascending and descending motion on each floor was analyzed. A wireless electromyography(EMG) were attached on the Rectus Femoris(RF), Biceps Femoris(BF), Gastrocnemius(GN), Tibialis Anterior(TA) muscle to calculate integrated EMG(iEMG), median frequency(MDF) and co-contraction index(CI). Chest and left heel accelerometer signal were recorded by wireless accelerometer and those were used to calculate approximate entropy(ApEn) for analyzing gait pattern. All analyses were performed with SPSS 21.0 and for repeated measured ANOVA and Post-hoc was LSD. Results : During ascending stairs, there were a statistically significant difference in Walking time between 1-2nd and other floors(p=.000), GN iEMG between 2-3th and 6-7th(p=.043) floor, TA MDF between 1-2nd and 5-6th(p=.030), 6-7th(p=.015) floor and TA/GN CI between 2-3th and 6-7th(p=.038) floor and ApEn between 1-2nd and 6-7th(x: p=.003, y: p=.005, z: p=.006) floor. During descending stairs, there were a statistically significant difference in TA iEMG between the 6-5th and 3-2nd(p=.026) floor, and for the ApEn between the 1-2nd and 6-7th(x: p=.037, y: p=.000, z: p=.000) floor. Conclusion : Subjects showed more regular pattern and muscle activation response caused by regularity during ascending stairs. Regularity during the first part of stair-descending could be a sign of adaptation; however, complexity during the second part could be a strategy to decrease the impact.

A study on the mechanical performance of impregnated polymer foam in cargo leakage of LNG carrier (LNG운반선의 화물 누출 시 함침된 고분자 폼의 기계적 성능에 관한 연구)

  • Park, Gi-Beom;Kim, Tae-Wook;Kim, Seul-Kee;Lee, Jae-Myung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.345-352
    • /
    • 2017
  • In this study, the effect of cryogenic liquefied natural gas leakage and loading on liquefied natural gas cargo hold is investigated to observe the performance of the polymer foam material that comprises the cryogenic insulation of the cargo hold. The primary barriers of liquefied natural gas carrier that are in contact with the liquefied natural gas will leak if damage is accumulated, owing to fluid impact loads or liquefied natural gas loading / unloading over a long period. The leakage of the cryogenic fluid affects the interior of the polymer foam, which is a porous closed cell structure, and causes a change in behavior with respect to the working load. In this study, mechanical properties of polyisocyanurate foam specimen, which is a polymer material used as insulation, are evaluated. The performance of the specimens, owing to the cold brittleness and the impregnation effects of the cryogenic fluids, are quantitatively compared and analyzed.

Estimation of PM10 Source Contributions on Three Cities in the Metropolitan Area by Using PMF Model (PMF 모델을 이용한 수도권 내 3개 도시에서의 PM10 오염원의 기여도 추정)

  • Lee, Tae-Jung;Huh, Jong-Bae;Yi, Seung-Muk;Kim, Shin-Do;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.4
    • /
    • pp.275-288
    • /
    • 2009
  • The Korean government strengthened the environmental polices to manage and enhance Metropolitan Area air quality, and also has enforced "Special Act on Seoul Metropolitan Air Quality Improvement (SASMAQI)" issued in Dec. 2004. Recently government expanded the Seoul Metropolitan Air Quality Management District (SMAQMD) to the outskirts satellite cities of Seoul area through the "Revised Law Draft of SASMAQI". The SMAQMD has been alloted the allowable emission loads to the local governments on the basis of the carrying $PM_{10}$ capacity. However, in order to establish the effective air quality control strategy for $PM_{10}$, it is necessary to understand the corresponding sources which have a potential to directly impact ambient $PM_{10}$ concentration. To deal with the situations, many receptor methodologies have been developed to identify the origins of pollutants and to determine the contributions of sources of interests. The objective of this study was to extensively identify $PM_{10}$ sources and to estimate their contributions at the metropolitan area. $PM_{10}$ samples were simultaneously collected at the 3 semi-industrialized local cities in the Seoul metropolitan area such as Hwasung-si, Paju-si, and Icheon-si sites from April 15 to May 31, 2007. The samples collected on the teflon membrane filter by one $PM_{10}$ cyclone sampler were analyzed for trace metals and soluble ions and samples on the quartz fiber filter by another sampler were analyzed for OC and EC. Source apportionment study was then performed by using a positive matrix factorization (PMF) receptor model. A total of 6 sources were identified and their contributions were estimated in each monitoring site. Contribution results on Hwasung, Paju, and Icheon sites were as follows: 33%, 27%, and 27% from soil source, 26%, 26%, and 21% from secondary aerosol source, 11%, 11%, and 12% from biomass burning, 12%, 6%, and 5% from sea salt, 7%, 15%, and 19% from industrial related source, and finally 11%, 15%, and 16% from mobile and oil complex source, respectively. This study provides information on the major sources affecting air quality in the receptor sites and thus it will help to manage the ambient air quality in the metropolitan area by establishing reasonable control strategies, especially for the anthropogenic emission sources.

Evaluation of the Stability of Geomembrane Liner System in Closed Waste Landfill (사용종료 폐기물 매립장의 멤브레인 차수시스템 안정성 평가)

  • Lee, Heung-Gil;Oh, Young-In
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • Recently, the effective use of closed waste landfill nearby urban areas has been demanded, because of the lack of the usable land. However, the reuse of closed landfill is needed an adequate stabilization of liner system. But most of these places are consisted of steep slope and hence it is necessary to use the geosynthetics liners in there. Liner system of waste landfills is an important facility which prevents leachate outgoing from the landfills and also groundwater infiltrating from surroundings into the landfills. During the waste disposal stage, differential settlement and tensile stress of the geosynthetic materials could occur due to impact load of trucks and dozers, waste loads and weak foundation soils. In this study, the tensile strength and tracer test were performed to evaluate the stability of geomembrane liner systems. Based on the tensile strength test result of in-situ geomembrane sample, the yield tensile strength maintain the suitable strength by specification and current law. However, according to the tracer test, the damage of geomembrane liner was detected on sanitary landfill section.

  • PDF

Evaluation of the Degradation Trend of the Polyurethane Resilient Pad in the Rail Fastening System by Multi-stress Accelerated Degradation Test (복합가속열화시험을 통한 레일체결장치 폴리우레탄 탄성패드의 열화 경향 분석)

  • Sung, Deok-Yong;Park, Kwang-Hwa
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.6
    • /
    • pp.466-472
    • /
    • 2013
  • The use of a concrete track is gradually growing in urban and high-speed railways in many part of the world. The resilient pad, which is essentially when concrete tracks are used, plays the important role of relieving the impact caused by train loads. The simple fatigue test[1] to estimate the variable stiffness of resilient pads is usually performed, but it differs depending on the practical conditions of different railways. In this study, the static stiffness levels of used resilient pads according to passing tonnages levels were measured in laboratory tests. Also, the simple fatigue test and the multi-stress accelerated degradation test for new resilient pads were performed in a laboratory. The static stiffness of the used pad was compared with the results of tests of usage times and cycles. The results of the comparison showed that the variable static stiffness levels of the used pad were similar to results of the multi-stress accelerated degradation test considering the fatigue and heat load. With a T-NT equation related to the degree of the multi-stress accelerated degradation, a model of multi-stress accelerated degradation for a resilient pad was devised. It was found through this effort that the total acceleration factor was approximately 2.62. Finally, this study proposes an equation for a multi-stress accelerated degradation model for polyurethane resilient pads.

Nonlinear Explosion Analyses for Damage Assessments of Reinforced Concrete Structures (비선형 폭발해석에 의한 콘크리트 구조물의 손상도 평가)

  • Huh, Taik Nyung;Kim, Seong Yun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • In general, the large loads which are applied from explosion, impact, earthquake and wind at a short time caused the materials of structures to large deformations, rotations and strains locally. If such phenomena will be analyzed, hydrocodes which can be considered fluid-structure interaction under computational continuum mechanics are inevitably needed. Also, the explosion mechanism is so complicated, it is reasonable that the behaviors of structure are predicted through explosion analyses and experiment at the same time. But, unfortunately, it is true that explosion experiments are limited to huge cost, large experiment facilities and safety problems. Therefore, in this study, it is shown that the results of explosion analyses using the AUTODYN are agreed with those of existing explosion experiments for reinforced concrete slabs within reasonable error limits. And the explosion damage of the same reinforced concrete slab are assessed for quite different reinforcement arrangement spacings, concrete cover depths, and vertical reinforcements. From the explosion analyses, it is known that the more the ratio of slab thickness to reinforcement arrangement spacing is increased, and small-diameter reinforcements are used than large-diameter reinforcements on the same reinforcement ratio, and vertical reinforcements are used, the more the anti-knock capacities are improved.

Design and Safety Performance Evaluation of the Riding Three-Wheeled Two-Row Soybean Reaper

  • Jun, Hyeon-Jong;Choi, Il-Su;Kang, Tae-Gyoung;Kim, Young-Keun;Lee, Sang-Hee;Kim, Sung-Woo;Choi, Yong;Choi, Duck-Kyu;Lee, Choung-Keun
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.288-293
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the key factors in designing a three-wheeled two-row soybean reaper (riding type) that is suitable for soybean production, and ensure worker safety by proposing optimal work conditions for the prototype of the designed machine in relation to the slope of the road. Methods: A three-wheeled two-row soybean reaper (riding type) was designed and its prototype was fabricated based on the local soybean-production approach. This approach was considered to be closely related to the prototype-designing of the cutter and the wheel driving system of the reaper. Load distribution on the wheels of the prototype, its minimum turning radius, static lateral overturning angle, tilt angle during driving, and The working and rear overturning (back flip) angle were measured. Based on the gathered information, investigations were conducted regarding optimal work conditions for the prototype. The investigations took into account driving stability and worker safety. Results: The minimum ground clearance of the prototype was 0.5 m. The blade height of the prototype was adjusted such that the cutter was operated in line with the height of the ridges. The load distribution on the prototype's wheels was found to be 1 (front wheel: F): 1.35 (rear-left wheel: RL): 1.43 (rear-right wheel: RR). With the ratio of load distribution between the RL and RR wheels being 1: 1.05, the left-to-right lateral loads were found to be well-balanced. The minimum turning radius of the prototype was 2.0 m. Such a small turning radius was considered to be beneficial for cutting work on small-scale fields. The sliding of the prototype started at $25^{\circ}$, and its lateral overturning started at $39.3^{\circ}$. Further, the critical slope angle for the worker to drive the prototype in the direction of the contour line on an incline was found to be $12.8^{\circ}$, and the safe angle of slope for the cutting was measured to be less than $6^{\circ}$. The critical angle of slope that allowed for work was found to be $10^{\circ}$, at which point the prototype would overturn backward when given impact forces of 1,060 N on its front wheel. Conclusions: It was determined that farmers using the prototype would be able to work safely in most soybean production areas, provided that they complied with safe working conditions during driving and cutting.

Analysis of Changes in Plantar Pressure While Walking in 4 Positions to Carry a Bag using the F-scan System (F-scan System을 이용한 4가지 가방휴대방법에 따른 보행 시 족저압의 변화 분석)

  • Lee, Jun-cheol
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.4
    • /
    • pp.439-448
    • /
    • 2018
  • With the aim of examining changes in plantar pressure while walking depending on the position of carrying a bag, this study measured the plantar pressure of 33 normal male and female adults using the F-scan System in four different positions to carry a bag: walking without carrying a bag; walking with carrying a bag on both shoulders; walking with carrying a bag on one shoulder; and walking with carrying a bag in one hand. Changes in the plantar pressure of the subjects obtained in this study and the asymmetry of the left and right feet were analyzed. The plantar pressure of the different areas of the feet in the four different positions to carry a bag was compared. The left foot, except its toes and metatarsus, showed a statistically significant difference among the five conditions, and the right foot, except its 4th and 5th caput metatarsalis, also showed a statistically significant difference (P>.05). Given the results of this study, this experiment to examine changes in plantar pressure does not seem to be enough to identify which position to carry a bag, except carrying a bag on both shoulders, would have the lowest negative impact on the feet. It will be necessary to conduct a follow-up study on changes in plantar pressure depending on the position of carrying a bag and methods that can effectively treat abnormal positions such as scoliosis and kyphosis using asymmetric loads.