• Title/Summary/Keyword: immersion depth

Search Result 133, Processing Time 0.032 seconds

A Study on Ion Exchange Method for Effective Ag Doping of Sputtering-Deposited CdTe Thin Film (스퍼터링 증착한 CdTe 박막의 효과적인 Ag 도핑을 위한 이온 교환법 연구)

  • Kim, Cheol-Joan;Park, Ju-Sun;Lee, Woo-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1169-1174
    • /
    • 2011
  • CdTe thin-film solar cell technology is well known that it can theoretically improve its conversion efficiency and manufacturing costs compared to the conventional silicon solar cell technology, due to its optical band gap energy (about 1.45eV) for solar energy absorption, high light absorption capability and low cost requirements for producing solar cells. Although the prior studies obtained the high light absorption, CdTe thin film solar cell has not been come up to the sufficient efficiency yet. So, doping method was selected for the improvement of the electrical characteristics in CdTe solar cells. Some elements including Cu, Ag, Cd and Te were generally used for the p-dopant as substitutional acceptors in CdTe thin film. In this study, the sputtering-deposited CdTe thin film was immersed in $AgNO_3$ solution for ion exchange method to dope Ag ions. The effects of immersion temperature and Ag-concentration were investigated on the optical properties and electrical characteristics of CdTe thin film by using Auger electron spectroscopy depth-profile, UV-visible spectrophotometer, and a Hall effect measurement system. The best optical and electrical characteristics were sucessfully obtained by Ag doping at high temperature and concentration. The larger and more uniform diffusion of Ag ions made increase of the Ag ion density in CdTe thin film to decrease the series resistance as well as mede the faster diffusion of light by the metal ions to enhance the light absorption.

A Study On The Development Of Virtual Underwater Environment And Sensory Simulator (가상 수중 환경과 체감형 시뮬레이터 개발에 관한 연구)

  • Youn, Jae-Hong;Hur, Gi-Taek;Kang, Im-Chul
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.4
    • /
    • pp.560-568
    • /
    • 2012
  • As for the implementation technology of virtual space, the experience method becomes multifunctional and it recognizes movement, sound, temperature and pressure and is expanding to the studies on the interaction possible intelligent interaction technology field between contents and users. The virtual reality technology is being studied to apply the 3D graphic technology and physical phenomena to virtual space to increase the sense of reality and use hardware devices to the virtual environment to increase immersive experience. The production of interactive contents about the virtual underwater environment needs bidirectional interface technology to connect hardware devices and ocean contents in order to increase the sense of a user to increase the sense of immersion. In this study, it tried to express the virtual underwater environment with the sense of actuality and reality from the analysis of the environmental factors according to changes in depth of water and from the application of the normalized underwater physical laws. Also it was to develop sensory contents having to experience the skin scuba without directly entering the water by connecting a sensory simulator about the skin scuba with the virtual underwater environment.

Optimization and Performance Evaluation for the Science Detector Systems of IGRINS

  • Jeong, Ueejeong;Chun, Moo-Young;Oh, Jae-Sok;Park, Chan;Yu, Young Sam;Oh, Heeyoung;Yuk, In-Soo;Kim, Kang-Min;Ko, Kyeong Yeon;Pavel, Michael;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.91.1-91.1
    • /
    • 2014
  • IGRINS (the Immersion GRating INfrared Spectrometer) is a high resolution wide-band infrared spectrograph developed by the Korea Astronomy and Space Science Institute (KASI) and the University of Texas at Austin (UT). This spectrograph has H-band and K-band science cameras, both of which use Teledyne's $2.5{\mu}m$ cutoff $2k{\times}2k$ HgCdTe HAWAII-2RG CMOS science grade detectors. Teledyne's cryogenic SIDECAR ASIC boards and JADE2 USB interface cards were installed to control these detectors. We performed lab experiments and test observations to optimize and evaluate the detector systems of science cameras. In this presentation, we describe a process to optimize bias voltages and way to reduce pattern noise with reference pixel subtraction schemes. We also present measurements of the following properties under optimized settings of bias voltages at cryogenic temperature (70K): read noise, Fowler noise, dark current, and reference-level stability, full well depth, linearity and conversion gain.

  • PDF

Evaluation on Applicability of Copper and Steelmaking Slags for Use of Heavy Weight Aggregates in Marine Concrete Structure (동슬래그 및 제강슬래그의 해양 콘크리트용 중량 골재 사용성 평가)

  • Moon, Hoon;Jang, Bo-Kil;Kim, Ji-Hyun;Chung, Chul-Woo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.345-352
    • /
    • 2017
  • Heavy weight concrete can be used in marine concrete structure to improve resistance against high wave energy. However, heavy weight aggregate, which is an indispensable material for heavy weight concrete, is difficult to be supplied in large quantities because its use is limited due to its high cost. In this work, the applicability of heavy weight by-products, copper and 3 month aged steelmaking slags, were evaluated as sources of heavy weight aggregate for marine concrete structures. Experimental results showed that copper slag was found to be a stable material for marine concrete structure. However, 3 month aged steelmaking slag showed significant expansion by $80^{\circ}$ water immersion test and ASTM C 1260 test. In addition, depth of chloride ion penetration in concrete was higher at which steelmaking slags were located. It was associated with porosity of steelmaking slag, and for this reason, steelmaking slag was not found to be suitable for marine concrete structure.

Work and Travel Experiences of Filipino Tourism Students in Selected Universities

  • Carpio, Geneive Joie;Torres, Athena Louise De;Samiran, Rinna;Villera, Kaselyn Joyce;Manguerra-Mahusay, Sharon
    • Asian Journal for Public Opinion Research
    • /
    • v.5 no.2
    • /
    • pp.143-174
    • /
    • 2018
  • A cultural exchange program widens the horizons of students. It gives them the opportunity to associate with other societies and learn their cultures at the same time. This program also serves as a training ground where students enhance their skills, acquire learnings, and gain experiences that will help them in their future careers and make them more competitive than others. Hence, the objective of this study is to come up with an output from a set of guidelines established and gathered from the different "work and travel" experiences of the participants. This study adopted the phenomenological and was conducted in places that are relatively quiet for recording, and suitable and convenient for both the researchers and participants. The researchers gathered data through in-depth interviews of samples gathered through snowball sampling. Cellphones were used to record interviews. At the end of the thematic analysis of information, the researchers came up with three major categories which included: (1) 'having the opportunity to know the industry well and improve one's capability', 'undergoing different cultural exchange experiences for better development', and 'being able to practice intercultural immersion'. Some of the researchers' recommendations would be to institute a feedback mechanism such as personal interviews, monitoring visits, etc. and use the output, a set of guidelines, that would help the future 'work and travel' participants to prepare and anticipate the program they would undergo.

Characteristics of High Frequency Ultrasonic Transducer Employing Polyvinylidene Fluoride and Detectability of Flaw in Cr-Ni Steel (PVDF 수침용 고주파수 초음파 탐촉자의 검출장과 Cr-Ni 강에서의 결함 검출능 측정)

  • Kim, Byoung-Geuk;Lee, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.1
    • /
    • pp.23-30
    • /
    • 1997
  • Recently high frequency ultrasonic transducers to employ polyvinylidene fluoride(PVDF) or polyvinylidene fluoride trifluoroethylene P(VDF-TrFE) have been used to detect small flaws in immersion testing. The detection field depending on the water path between the transducer and a specimen and the path in a tested specimen was measured using a PVDF transducer with nominal frequency 80MHz. Also, C-scan and B-scan were performed for the specimens made of Cr-Ni steel with the artificial flaws, the flat-bottom holes with diameter ranging from $50{\mu}m$ to $560{\mu}m$ at 12mm depth. As the result, the flaws with diameter larger than $280{\mu}m$ were detected, but the flaws with the ratio of diameter to wavelength smaller than about 0.48 were not detected. That the smaller flaws could not be detected was attributed to the attenuation of high frequency components in the steel specimens.

  • PDF

A Study of Accelerated Corrosion Test and Chloride Penetration Analysis with Artificial Seawater Immersion Condition (인공해수 침지조건에 따른 부식촉진시험과 염화물침투해석에 대한 연구)

  • Park, Sang-Soon;Jeong, Ji-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.93-100
    • /
    • 2014
  • Steel reinforcement buried in concrete structure in submerged zone does not easily become corroded due to lack of dissolved oxygen. For that reason, accelerated corrosion test in submerged state is performed with an electrochemical method, which is not suitable for actual corrosion mechanism and makes it difficult to find relevance with long-term behavior. In this study, accelerated corrosion test was performed with the temperature and chloride concentration as main variables in order to establish a method for accelerated corrosion test in submerged zone. Corrosion was determined by the result of reinforcement corrosion monitoring based on galvanic potential measurement and half-cell potential method. The accelerated corrosion test result showed that temperature had the most dominant influence. To determine the chloride content, chloride concentration by depth in the test sample was measured. With the same conditions, chloride penetration interpretation was performed by DuCOM, a FEM durability interpretation program. Also, a test was performed to measure dissolved oxygen according to soaking conditions of artificial seawater, which was used for verifying the validity of the accelerated corrosion test result.

SURFACE ROUGHNESS OF UNIVERSAL COMPOSITES AFTER POLISHING PROCEDURES (전.구치 겸용 혼합형 복합레진의 두 가지 연마법에 따른 표면조도)

  • Lee, Jae-Yong;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.369-377
    • /
    • 2003
  • The aim of this study was to evaluate the effect of two polishing methods and chemical conditioning on the surface of hybrid composites. Ninety cylindrical specimens (diameter:8mm, depth:2mm) were made with three hybrid composites-Filtek Z250, Tetric Ceram. DenFil. Specimens for each composite were randomly divided into three treatment subgroups $^{\circled1}$ Mylar strip (no treatment). $^{\circled2}$ Sof-Lex XT system, $^{\circled3}$ PoGo system. Average surface roughness(Ra) was taken using a surface profilometer at the time of setting and after immersion into 0.02N lactic acid for 1 week and 1 month. Representative specimens were examined by scanning electron microscopy. The data were analyzed using ANOVA and Scheffe's tests at 0.05% significance level. The results were as follows:1. Mylar strip resulted in smoother surface than PoGo and Sof-Lex system (p<0.001). Sof-Lex system gave the worst results. 2. Tetric Ceram was smoother than DenFil and Z250 when cured under only mylar strip. However, it was significantly rougher than other materials when polished with PoGo system. 3. All materials showed rough surface after storage in 0.02N lactic acid, except groups polished with a PoGo system. The PoGo system gave a superior polish than Sof-Lex system for the three composites. However. the correlation to clinical practice may be limited, since there are several processes. such as abrasive, fatigue, and corrosive mechanisms. Thus. further studies are needed for polishing technique under in vivo conditions.

Realistic-Contents Generation Techniques with Stereoscopic and Composite Image Data (영상 데이터의 입체화 및 합성 기반 실감 콘텐츠 생성 기법)

  • Kim Manbae;Hong Donghee;Cho Youngran;Kim Haksoo
    • Journal of Broadcast Engineering
    • /
    • v.9 no.4 s.25
    • /
    • pp.402-410
    • /
    • 2004
  • Recently, there has been much interest in realistic broadcasting that is a new field following HDTV and 3DTV. In general. the realistic broadcasting is composed of diverse components such as aquisition, authoring, compression, transmission and display, posing many challenging tasks. It is necessary that the types of realistic contents need to be defined prior to the development of realistic broadcasting systems. Based upon them, other components need to be designed and developed. In this paper, we propose some realistic contents suitable to the realistic broadcasting as well as techniques of generating them. Our proposed contents consist of stereoscopic multiview sequences, object-based stereoscopic images, depth map-based image compositing and the composition of stereoscopic real and graphics images. Content generation techniques and their associated software modules are presented with realistic images produced from our experiments. Those contents are produced to deliver stereoscopic perception, immersion and realism to the users as shown in our experimental results.

A STUDY ON THE MICROLEAKAGE OF RETROFILLED TEETH WITH VARIOUS MATERIALS AND INSTRUMENTS FOR CAVITY PREPARATION (역행충전시 와동형성 기구 및 수복재에 따른 변연누출에 관한 연구)

  • Lee, Jae-Yong;Cho, In-Ho;Hong, Chan-Ui;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.187-196
    • /
    • 1993
  • The purpose of this study was to evaluate the microleakage of retrofilled teeth with various materials [non-zinc Amalgam, IRM, Ketac-silver, CGP(cold-burnished, ultrafil)[and instruments for cavity preparation. Root apex were resected 2mm from apex horizontally and class I cavities were prepared in 2mm denpth, 1.5mm width and were filled with above mentioned materials. Root apex were resected 2mm from apex horizontally and class I cavities were prepared in 2mm depth, 1. 5mm width and were filled with above mentioned materials. 2% methylene blue dye solution was used for 4 days immersion and the linear leakage was measured with calipers and the volumetric leakage was determined with a spectrophotometer. The results were as follows : 1. Amalgam group showed the greatest amount of leakage and Ketac-silver group showed the least value. 2. By linear leakage test, the group retrofilled with Ketac-silver, or CGP showed better seal than the group of Amalgam or IRM. This was shown in both retrograde tip and Conventional method. 3. By volumetric leakage test, the group retrofilled with Ketac-silver showed significantly better seal than the group with IRM in retrograde tip method. 4. By volumetric leakage test, the group retrofilled with Ketac-silver showed significantly better seal than the group with Amalgam in the Conventional method.

  • PDF